Search NASA⌕ Search

SEARCH · Search NASA

Results for “membrane separations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Process of treating cellulosic membrane and alkaline with membrane separator

The improvement of water-soluble cellulose ether membranes for use as separators in concentrated alkaline battery cells is discussed. The process of contacting membranes with an aqueous alkali solution of concentration less than that of the alkali solution to be used in the battery but above that at which the membrane is soluble is described.

Hoyt, H. E.↗

Scalable Production Method for Graphene Oxide Water Vapor Separation Membranes

ABSTRACT Membranes for selective water vapor separation were assembled from graphene oxide suspension using techniques compatible with high volume industrial production. The large-diameter graphene oxide flake suspensions were synthesized from graphite materials via relatively efficient chemical oxidation steps with attention paid to maintaining flake size and achieving high graphene oxide concentrations. Graphene oxide membranes produced using scalable casting methods exhibited water vapor flux and water/nitrogen selectivity performance meeting or exceeding that of membranes produced using vacuum-assisted laboratory techniques. (PNNL-SA-117497)

Environmental Molecular Sciences Laboratory↗

Transport Reactor Development Unit Modification to Provide a Syngas Slipstream at Elevated Conditions to Enable Separation of 100 LB/D of Hydrogen by Hydrogen Separation Membranes Year - 6 Activity 1.15 - Development of a National Center for Hydrogen Technology

Gasification of coal when associated with carbon dioxide capture and sequestration has the potential to provide low-cost as well as low-carbon hydrogen for electric power, fuels or chemicals production. The key element to the success of this concept is inexpensive, effective separation of hydrogen from carbon dioxide in synthesis gas. Many studies indicate that membrane technology is one of the most, if not the most, economical means of accomplishing separation; however, the advancement of hydrogen separation membrane technology is hampered by the absence of experience or demonstration that the technology is effective economically and environmentally at larger scales. While encouraging performance has been observed at bench scale (less than 12 lb/d hydrogen), it would be imprudent to pursue a largescale demonstration without testing at least one intermediate scale, such as 100 lb/d hydrogen. Among its many gasifiers, the Energy & Environmental Research Center is home to the transport reactor demonstration unit (TRDU), a unit capable of firing 200—500 lb/hr of coal to produce 400 scfm of synthesis gas containing more than 200 lb/d of hydrogen. The TRDU and associated downstream processing equipment has demonstrated the capability of producing a syngas over a wide range of temperatures and contaminant levels — some of which approximate conditions of commercial-scale gasifiers. Until this activity, however, the maximum pressure of the TRDU’ s product syngas was 120 psig, well below the 400+ psig pressures of existing large gasifiers. This activity installed a high-temperature compressor capable of accepting the range of TRDU products up to 450°F and compressing them to 500 psig, a pressure comparable to some large scale gasifiers. Thus, with heating or cooling downstream of the TRDU compressor, the unit is now able to present a near-raw to clean gasifier synthesis gas containing more than 100 lb/d of hydrogen at up to 500 psig over a wide range of temperatures to hydrogen separation membranes or other equipment for development and demonstration.

01 COAL, LIGNITE, AND PEAT↗

Active Dendrite Suppression by Ferroelectric Membrane Separators in Rechargeable Batteries

Anodic dendrite formation is a critical issue in rechargeable batteries and often leads to poor cycling stability and quick capacity loss. Prevailing strategies for dendrite suppression aim at slowing down the growth rate kinetically but still leaving possibilities for dendrite evolution over time. Herein, we report a complete dendrite elimination strategy using a mesoporous ferroelectric polymer membrane as the battery separator. The dendrite suppression is realized by spontaneously reversing the surface energetics for metal ion reduction at the protrusion front, where a positive piezoelectric polarization is generated and superimposed as the protrusion compresses the separator. This effect is demonstrated first in a Zn electroplating process, and further in Zn–Zn symmetric cells and Zn–NaV 3 O 8 ·1.5H 2 O full cells, where the dendritic Zn anode surfaces are completely turned into featureless flat surfaces. Consequently, a substantially longer charging/discharging cycle is achieved. Furthermore, this study provides a promising pathway toward high-performance dendrite-free rechargeable batteries.

25 ENERGY STORAGE↗

Membrane Separation of Gases From The Martian Atmosphere

A test bed has been constructed to test membrane modules for separation of gases under temperature and pressure conditions normally encountered on the surface of Mars. The test bed allows independent control of (1) feed flow rates, (2) feed composition, (3) feed pressure, (4) permeate pressure, and (5) operating temperature. Preliminary data obtained at a nominal feed pressure of 760 torr and permeate pressure of 10 torr has demonstrated the ability of one membrane module to operate at temperatures as low as -70 C. At temperatures below -40 C, however, significant loss of carbon dioxide and argon was observed, probably indicating condensation at the relatively high pressure used. As expected, permeation flow rates decreased with decreasing temperature, the flow at -30 C approximately 37% of the value at +23 C. Values of permeability for individual gas components showed similar decreases with decreasing temperature, but permeability ratios changed significantly. For example, the ratio of the permeabilities of carbon dioxide and nitrogen increased from 2.6 at 23 C to 5.6 at -30 C. Additional data at lower operating pressures and temperatures must be obtained in order to optimize design of a usable separation system.

Jennings, Paul A.↗

Membrane Separation of Gases from the Martian Atmosphere

A test bed has been constructed to test membrane modules for separation of gases under temperature and pressure conditions normally encountered on the surface of Mars. The test bed allows independent control of: (1) feed flow rates, (2) feed composition, (3) feed pressure, (4) permeate pressure, and (5) operating temperature. Preliminary data obtained at a nominal feed pressure of 760 torr and permeate pressure of 10 torr has demonstrated the ability of one membrane module to operate at temperatures as low as -70 C. At temperatures below -40 C, however, significant loss of carbon dioxide and argon was observed, probably indicating condensation at the relatively high pressure used. As expected, permeation flow rates decreased with decreasing temperature, the flow at -30 C approximately 37% of the value at +23 C. Values of permeability for individual gas components showed similar decreases with decreasing temperature, but permeability ratios changed significantly. For example, the ratio of the permeabilities of carbon dioxide and nitrogen increased from 2.6 at 23 C to 5.6 at -30 C. Additional data at lower operating pressures and temperatures must be obtained in order to optimize design of a usable separation system.

Jennings, Paul A.↗

Fabrication and accelerated long-term stability test of asymmetrical hollow fiber-supported thin film oxygen separation membrane

Asymmetrical hollow fiber-supported thin film membrane may provide microstructural advantages for air separation and oxygen production. The fabrication of such a membrane is usually very difficult, particularly the sintering behaviors and thermal expansion coefficient (TEC) mismatch among multiple layers. This directly affects the reliability and long-term stability of the membrane. Here, in this research, the sintering behaviors of a set of simple oxides are systematically studied and ZnO is identified as a material component for composite substrate La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3-δ (LSCF)-ZnO. The LSCF-ZnO ratios are further optimized by trading off several factors, e.g., matching the sintering behaviors and TECs of the LSCF-ZnO composite with those of LSCF thin film separation layer while enhancing the substrate strength. With the identified LSCF-ZnO ratio, the LSCF-ZnO composite hollow fiber substrate precursor is formed through slurry spinning process with porous microstructure being formed via phase inversion process. The thin film LSCF dense separation layer is then dip-coated on the substrate followed by co-sintering process. A thin, porous PrBaCo(Fe 0.6 Zr 0.2 Y 0.2 )O 5+δ (PBCFZY) catalyst layer is fabricated on the dense LSCF separation layer with dip-coating and sintering process, forming an asymmetrical membrane device LSCF-ZnO/LSCF/PBCFZY. Oxygen permeation test of the device is systematically conducted, and the fundamental mechanisms are analyzed. An accelerated long-term stability test of the membrane is also conducted (~550h, 46 thermal cycling loads), demonstrating excellent robustness and durability. The device is characterized and analyzed before and after the test. By replacing a considerable amount of high cost LSCF with low cost ZnO in the substrate, it not only enhances the stability but also reduces the capital cost of the membrane for practical applications.

42 ENGINEERING↗

Ion-gated carbon molecular sieve gas separation membranes

Membrane technology lies at the heart of many industrial gas separation processes and applications. Molecular sieving membranes that break the Robeson limit are desirable for energy-efficient gas separation. In this paper, we report a facile strategy of directly integrating ionic liquids (ILs) into porous membranes. Particularly, the ILs form an ultra-thin layer on the carbon molecular sieve (CMS) membranes rather than penetrating into the pores, acting as a smart gate for gas entry to boost the selectivity. The hybrid membrane exhibits CO 2 permeability >600 barrer and enhanced CO 2 /N 2 selectivity >50, which surpasses the Robeson limit and shows potential in CO 2 /N 2 separation process. Molecular dynamics simulations confirm the gating effect of the IL layer of molecular thickness. In conclusion, this work demonstrates a universal strategy to improve CMS membrane performance by creating an IL-membrane interface and tuning the ion-pore interaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interaction of gas molecules with crystalline polymer separation membranes: Atomic-scale modeling and first-principles calculations

Carbon dioxide (CO2)-induced plasticization can significantly decrease the gas separation performance of membranes in high-temperature or high pressure conditions, such as industrial methane (CH4) separations. In this paper, we investigated the crystalline phase of three polymers (polybenzimidazole (PBI), Bis(isobutylcarboxy)polybenzimidazole (PBI-Butyl), and KaptonTM) and interactions between gas molecules (CO2 and N2) and these polymers. A novel, molecular dynamics (MD) based, computational technique was employed to find unknown crystalline structures of these polymer materials. The interaction of CO2 and N2 gases with these crystals was studied by first-principles calculations and by classical MD simulations. The results showed that the packing structure and the interlayer coupling in polymer crystals determine the permeability and diffusivity of gas molecules. This methodology also allows prediction of plastic swelling in these materials caused by gas molecules absorbed in the polymer matrix.

03 NATURAL GAS↗

FUEL 254: Activation of molecular hydrogen on palladium separation membrane surfaces in the presence of H 2 S

Dense palladium-based membranes are of significant interest for separation of hydrogen from mixed gas streams. In this work, flux measurements, materials characterization, and computational modeling combine to provide a framework for understanding the influence of sulfur on molecular hydrogen's dissociative adsorption on Pd and Pd-alloy surfaces and, thus, a foundation for membrane design improvements. Two modes of sulfur-induced deactivation are observed during membrane flux testing. A corrosive decay mechanism is associated with formation of a thick, low diffusivity, Pd 4 S scale layer on the membrane surface. In this case, both the surface region and top layer of the scale display Pd 4 S stoichiometry; Pd-terminated Pd 4 S low-index faces appear to provide the activity required for hydrogen dissociation. A catalytic poisoning mechanism is not associated with formation of a stable sulfide compound; instead, it may result in formation of a thin, sulfur-rich (relative to Pd 4 S) overlayer that effectively inhibits the dissociation reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High temperature steam separation membrane

Ceramic proton-conducting oxide membranes are described herein, which are useful for separating steam from organic chemicals under process conditions. The membranes have a layered structure, with a dense film of the perovskite over a porous composite substrate comprising the perovskite material and a metallic material (e.g., Ni, Cu, or Pt). The perovskite comprises an ABO 3 -type structure, where “A” is Ba and “B” is a specified combination of Ce, Zr, and Y. The perovskite ceramic materials described herein have an empirical formula of Ba(Ce x Zr 1-x-n Y n )O 3-δ , wherein 0<x<0.8 (e.g., 0.1≤x≤0.7 or 0.2≤x≤0.5); and 0.05≤n≤0.2; and δ=n/2. In some embodiments n is about 0.2. In some other embodiments 0.6≤x≤0.8; and n is about 0.2, such as Ba(Ce 0.7 Zr 0.1 Y 0.2 )O 3-δ , also referred to herein as BCZY712.

Lee, Tae H.↗

A Performance analysis of the Claridge-Culp-Liu dehumidification process: A novel approach for drying moist air based on membrane separation, vacuum compression and sub-atmospheric condensation

This article covers a basic model for analyzing the performance of the Claridge-Culp-Liu dehumidification process. The fundamental process efficiency limit for dehumidification is close to COP Carnot , but for the eight dehumidification cases examined, the limiting or ideal energy use required is 26% to 56% that of a Carnot condensing system as shown in an earlier paper. The model presented in this paper is used to show the membrane system performance reduction caused by finite membrane area, finite water vapor permeance, non-zero air permeance, non-zero system air pressure drop, non-ideal compressors, vacuum pumps, and condensers. The performance of a “conservative” membrane system based on the use of existing components is computed for eight specific conditions along with that of a “target” system that assumes expected component performance after additional future component development. The “conservative” membrane system would use 36% to 66% as much energy as a system with a COP=7 chiller to produce the same dehumidification for the eight cases examined while the “target” system would use 15% to 40% the energy of a system with a COP=7 chiller. In addition to the significant energy reduction over conventional technology, the membrane system offers the advantages of: 1) no HFC refrigerant use; 2) direct isothermal control over humidity ratio setpoint; 3) maximum capacity occurs at design conditions; and 4) system generates pure water extracted from air as a by-product.

42 ENGINEERING↗

Membrane Separation of CO 2 and Hydrocarbons

Separation of CO 2 and hydrocarbons using membrane technology. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=3A4F41D9-3F80-4952-A81E-6D38AD4A20C9

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molten hydroxide membrane for separation of acid gases from emissions

In one embodiment, a separation membrane includes: a porous support structure, wherein the porous support structure comprises a system of continuous pores connecting an inlet of the separation membrane to an outlet of the separation membrane; and at least one alkali metal hydroxide disposed within pores of the porous support structure. Other aspects and embodiments of the disclosed inventive concepts will become apparent from the detailed description, which, when taken in conjunction with the drawings, illustrate by way of example the principles of the invention.

Worsley, Marcus↗

Membrane Separation Processes at Low Temperatures

The primary focus of Kennedy Space Center's gas separation activities has been for carbon dioxide, nitrogen, and argon used in oxygen production technologies for Martian in-situ resource utilization (ISRU) projects. Recently, these studies were expanded to include oxygen for regenerative life support systems. Since commercial membrane systems have been developed for separation of carbon dioxide, nitrogen, and oxygen, initially the studies focused on these membrane systems, but at lower operating temperatures and pressures. Current investigations art examining immobilized liquids and solid sorbents that have the potential for higher selectivity and lower operating temperatures. The gas separation studies reported here use hollow fiber membranes to separate carbon dioxide, nitrogen, and argon in the temperature range from 230 to 300 K. Four commercial membrane materials were used to obtain data at low feed and permeate pressures. These data were used with a commercial solution-diffusion modeling tool to design a system to prepare a buffer gas from the byproduct of a process to capture Martian carbon dioxide. The system was designed to operate, at 230 K with a production rate 0.1 sLpm; Feed composition 30% CO2, 44% N2, and 26% Ar; Feed pressure 104 kPa (780); and Permeate pressure 1 kPa (6 torr); Product concentration 600 ppm CO2. This new system was compared with a similar system designed to operate at ambient temperatures (298 K). The systems described above, along with data, test apparatus, and models are presented.

Parrish, Clyde↗