At least 91 records · Page 5

Development and Fabrication of Nanoporous Silicon-based Bioreactors within a Microfluidic Chip

Multi-scale lithography and cryogenic deep reactive ion etching techniques were used to create ensembles of nanoporous, picoliter volume, reaction vessels within a microfluidic system. The fabrication of these vessels is described and how this process can be used to tailor vessel porosity by controlling the width of slits that constitute the vessel pores is demonstrated. Control of pore size allows the containment of nucleic acids and enzymes that are the foundation of biochemical reaction systems, while allowing smaller reaction constituents to traverse the container membrane and continuously supply the reaction. In this work, a 5.4kB DNA plasmid was retained within the reaction vessels and labeled under microfluidic control with ethidium bromide as an initial proof-of-principle. Subsequently, a coupled enzyme reaction, in which glucose oxidase and horseradish peroxidase were contained and fed with a substrate solution of glucose and Amplex Red to produce fluorescent Resorufin, was carried out under microfluidic control and monitored using fluorescent microscopy. The fabrication techniques presented are broadly applicable and can be adapted to produce devices in which a variety of high aspect ratio, nanoporous silicon structures can be integrated within a microfluidic network. The devices shown here are amenable to being scaled in number and organized to implement more complex reaction systems for applications in sensing and production of biologically based therapeutics as well as fundamental studies of biological reaction systems.

09 BIOMASS FUELS↗

Quantifying the Spatiotemporal Dynamics of Plant Root Colonization by Beneficial Bacteria in a Microfluidic Habitat

Plant–microbe interactions underpin processes related to soil ecology, plant function, and global carbon cycling. However, quantifying the spatial dynamics of these interactions has proven challenging in natural systems. Currently, microfluidic platforms are at the forefront of innovation for culturing, imaging, and manipulating plants in controlled environments. Using a microfluidic platform to culture plants with beneficial bacteria, visualization and quantification of the spatial dynamics of these interactions during the early stages of plant development is possible. For two plant growth–promoting bacterial isolates, the population of bacterial cells reaches a coverage density of 1–2% of the root's surface at the end of a 4 d observation period regardless of bacterial species or inoculum concentration. The two bacterial species form distinct associations with root tissue through a mechanism that appears to be independent of the presence of the other bacterial species, despite evidence for their competition. Root development changes associated with these bacterial treatments depend on the initial concentrations and species of the bacterial population present. Finally, this microfluidic approach provides context for understanding plant–microbe interactions during the early stages of plant development and can be used to generate new hypotheses about physical and biochemical exchanges between plants and their associated microbial communities.

59 BASIC BIOLOGICAL SCIENCES↗

Drop mass transfer in a microfluidic chip compared to a centrifugal contactor

A model system was developed for enabling a multiscale understanding of centrifugal-contactor liquid–liquid extraction.The system consisted of Nd(III) + xylenol orange in the aqueous phase buffered to pH =5.5 by KHP, and dodecane + thenoyltrifluroroacetone (HTTA) + tributyphosphate (TBP) in the organic phase. Diffusion constants were measured for neodymium in both the organic and aqueous phases, and the Nd(III) partition coefficients were measured at various HTTA and TBP concentrations. A microfluidic channel was used as a high-shear model environment to observe mass-transfer on a droplet scale with xylenol orange as the aqueous-phase metal indicator; mass-transfer rates were measured quantitatively in both diffusion and reaction limited regimes on the droplet scale. Lastly, the microfluidic results were comparable to observations made for the same system in a laboratory scale liquid–liquid centrifugal contactor, indicating that single drop microfluidic experiments can provide information on mass transfer in complicated flows and geometries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging Liquids Using Microfluidic Cells

Chemistry occurring in the liquid and liquid surface is important in many applications. Chemical imaging of liquids using vacuum based analytical techniques is challenging due to the difficulty in working with liquids with high volatility. Recent development in microfluidics enabled and increased our capabilities to study liquid in situ using surface sensitive techniques such as electron microscopy and spectroscopy. Due to its small size, low cost, and flexibility in design, liquid cells based on microfluidics have been increasingly used in studying and imaging complex phenomena involving liquids. This paper presents a review of microfluidic cells that were developed to adapt to electron microscopes and various spectrometers for in situ chemical analysis and imaging of liquids. The following topics will be covered including cell designs, fabrication techniques, unique technical features for vacuum compatible cells, and imaging with electron microscopy and spectroscopy. Challenges are summarized and recommendations for future development priority are proposed.

Environmental Molecular Sciences Laboratory↗

Selective synthesis of human milk fat-style structured triglycerides from microalgal oil in a microfluidic reactor packed with immobilized lipase

Human milk fat-style structured triacylglycerols were produced from microalgal oil in a continuous microfluidic reactor packed with immobilized lipase for the first time. A remarkably high conversion efficiency was demonstrated in the microreactor with reaction time being reduced by 8 times, Michaelis constant decreased 10 times, the lipase reuse times increased 2.25-fold compared to those in a batch reactor. In addition, the content of palmitic acid at sn-2 position (89.0%) and polyunsaturated fatty acids at sn-1, 3 positions (81.3%) are slightly improved compared to the product in a batch reactor. The increase of melting points (1.7 °C) and decrease of crystallizing point (3 °C) implied higher quality product was produced using the microfluidic technology. The main cost can be reduced from 212.3 to 14.6 per batch with the microreactor. Altogether, the microfluidic bioconversion technology is promising for modified functional lipids production allowing for cost-effective approach to produce high-value microalgal coproducts.

09 BIOMASS FUELS↗

A Wearable Microfluidic Sensing Patch for Dynamic Sweat Secretion Analysis

Wearable sweat sensing is a rapidly rising research area driven by its promising potential in health, fitness, and diagnostic applications. Despite the growth in the field, major challenges in relation to sweat metrics remain to be addressed. These challenges include sweat rate monitoring for its complex relation with sweat compositions and sweat sampling for sweat dynamics studies. Here, we present a flexible microfluidic sweat sensing patch that enhances real-time electrochemical sensing and sweat rate analysis via sweat sampling. The device contains a spiral-patterned microfluidic component that is embedded with ion-selective sensors and an electrical impedance-based sweat rate sensor on a flexible plastic substrate. The patch is enabled to autonomously perform sweat analysis by interfacing the sensing component with a printed circuit board that is capable of on-site signal conditioning, analysis, and transmission. Progressive sweat flow in the microfluidic device, governed by the pressure induced by the secreted sweat, enhances sweat sampling and electrochemical detection via a defined sweat collection chamber and a directed sweat route. The characteristic of the sweat rate sensor is validated through a theoretical simulation, and the precision and accuracy of the flow rate is verified with a commercial syringe pump and a Macroduct sweat collector. On-body simultaneous monitoring of ion (H + , Na + , K + , Cl – ) concentration and sweat rate is also demonstrated for sensor functionality. This sweat sensing patch provides an integrated platform for a comprehensive sweat secretion analysis and facilitates physiological and clinical investigations by closely monitoring interrelated sweat parameters.

47 OTHER INSTRUMENTATION↗

Microfluidic Sensors with Impregnated Fluorophores for Simultaneous Imaging of Spatial Structure and Chemical Oxygen Gradients

Inside surfaces of polystyrene microfluidic structures were impregnated with the oxygen sensing dye (PtTFPP) using a solvent-induced fluorophore impregnation (SIFI) method. By this technique, microfluidic oxygen sensors are obtained that enable simultaneous imaging of both chemical oxygen gradients and the physical structure of the microfluidic interior. A gentle method of fluorophore impregnation using acetonitrile solutions of PtTFPP at 50oC was developed leading to 10 micron deep region containing fluorophore. This region is localized at the surface to sense oxygen in the interior fluid during use. Regions of the device that do not contact the interior fluid pathways lack fluorophores and are dark in fluorescent imaging. The technique was demonstrated on straight microchannel and pore network devices, the latter having pillars of 300 µm diameter spaced center to center at 340 µm providing pore throats of 40 µm. Sensing within channels or pores, and imaging across the pore network devices were performed using a Lambert LIFA-P frequency domain fluorescence lifetime imaging system on a Leical microscope platform. Calibrations of different devices prepared by the SIFI method were indistinguishable. Gradient imaging showed fluorescent regions corresponding to the fluid pore network, dark pillars, and fluorescent lifetime varying across the gradient, thus providing both physical and chemical imaging. More generally, the SIFI technique can impregnate the interior surfaces of other polystyrene containers, such as cuvettes or cell and tissue culture containers, to enable sensing interior conditions.

microfluidic, sensor, imaging, oxygen↗

Online monitoring of solutions within microfluidic chips: simultaneous Raman and UV-Vis absorption spectroscopies

Microfluidics is an appealing analytical tool in the global effort to close the nuclear fuel cycle. Using a microfluidic chip permits analysis of greatly reduced sample volumes compared to what is necessary for traditional analytical methods. There is a commensurate reduction in disposal volume and cost. Development of spectroscopic methods practicable on the microscale are necessary to take advantage of the microchip configuration. This study uses simultaneously applied UV-vis and micro-Raman spectroscopies adapted to function on the microscale to analyze in situ both the Nd3+ (UV-vis active) and HNO3 (Raman active) concentrations in the same sample. An adjustable translation platform was designed to hold the micro-Raman probe above and perpendicular to the chip face, and the UV-vis probe in the plane of the chip. These complimentary spectral techniques when processed through multivariate PLS (Partial Least Squares) models gave an accurate picture of the widely varying solution concentrations as a function of time for each solution component. Solution matrix effects can drastically alter analyte signatures as measured by both UV-vis absorbance and Raman spectroscopy. PLS methods successfully modeled these spectral changes and accurately measured concentrations of components of interest within the microfluidic chip.

on-line monitoring, microfluidics, Raman, UV-vis↗

A Droplet Microfluidic Platform for Automating Genetic Engineering

We present a water-in-oil droplet microfluidic platform for transformation, culture and expression of recombinant proteins in multiple host organisms including bacteria, yeast and fungi. The platform consists of a hybrid digital microfluidic/channel-based droplet chip with integrated temperature control to allow complete automation and integration of plasmid addition, heat-shock transformation, addition of selection medium, culture, and protein expression. The microfluidic format permitted significant reduction in consumption (100-fold) of expensive reagents such as DNA and enzymes compared to the benchtop method. Furthermore, the chip contains a channel to continuously replenish oil to the culture chamber to provide a fresh supply of oxygen to the cells for long-term (~5 days) cell culture. The flow channel also replenished oil lost to evaporation and increased the number of droplets that could be processed and cultured. The platform was validated by transforming several plasmids into Escherichia coli including plasmids containing genes for fluorescent proteins GFP, BFP and RFP; plasmids with selectable markers for ampicillin or kanamycin resistance; and a Golden Gate DNA assembly reaction. We also demonstrate the applicability of this platform for transformation in widely used eukaryotic organisms such as Saccharomyces cerevisiae and Aspergillus Niger. Duration and temperatures of the microfluidic heat-shock procedures were optimized to yield transformation efficiencies comparable to those obtained by benchtop methods with a throughput up to 6 droplets/min. The platform we proposed offers potential for automation of molecular biology experiments significantly reducing cost, time and variability while improving throughput.

59 BASIC BIOLOGICAL SCIENCES↗

A capillary-based microfluidic device enables primary high-throughput room-temperature crystallographic screening

A novel capillary-based microfluidic strategy to accelerate the process of small-molecule-compound screening by room-temperature X-ray crystallography using protein crystals is reported. The ultra-thin microfluidic devices are composed of a UV-curable polymer, patterned by cleanroom photolithography, and have nine capillary channels per chip. The chip was designed for ease of sample manipulation, sample stability and minimal X-ray background. 3D-printed frames and cassettes conforming to SBS standards are used to house the capillary chips, providing additional mechanical stability and compatibility with automated liquid- and sample-handling robotics. These devices enable an innovative in situ crystal-soaking screening workflow, akin to high-throughput compound screening, such that quantitative electron density maps sufficient to determine weak binding events are efficiently obtained. This work paves the way for adopting a room-temperature microfluidics-based sample delivery method at synchrotron sources to facilitate high-throughput protein-crystallography-based screening of compounds at high concentration with the aim of discovering novel binding events in an automated manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In situ , in vivo , and in operando imaging and spectroscopy of liquids using microfluidics in vacuum

This review offers a succinct overview of the development of a vacuum-compatible microfluidic reactor system for analysis at the liquid vacuum interface (SALVI), and its diverse applications in in situ, in vivo, and in operando imaging of liquid surfaces as well as the air-liquid (a-l), liquid-liquid (l-l), and solid-liquid (s-l) interfaces in the past decade. SALVI is one of the first microfluidics-based reactors that has enabled direct analysis of volatile liquids in vacuum surface tools such as scanning electron microscopy (SEM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). Its integration into ambient and vacuum spectroscopy and microscopy is illustrated. Several applications are highlighted including (1) imaging nanoparticles in liquid using in situ SEM; (2) mapping the evolving l-l interface using in situ x-ray absorption spectroscopy and ToF-SIMS; (3) following complex a-l interfacial oxidation reaction products using in situ ToF-SIMS; (4) capturing biological interfaces of cells and microbes via in vivo multimodal and correlative imaging; and (5) monitoring the dynamic solid electrode and liquid electrolyte interface using in operando molecular imaging. Finally, outlook and recommendations are presented. Besides showing the holistic information volume obtained by real-time multiplexed imaging, this review intends to convey the importance of tool development in revolutionizing surface and interface analysis using vacuum platforms previously limited to solid surfaces. Microfluidics is manifested to be not limited to ambient conditions in many examples in this review. Moreover, fundamental interfacial phenomena underpinning mass and charge transfer can now be pursued in real time via innovated chemical imaging and spectroscopy.

42 ENGINEERING↗

Bead-Based Assays for Biodetection: From Flow-Cytometry to Microfluidics

ABSTRACT The potential for the use of biological agents by terrorists is a real threat. Two approaches for detection of biological species will be described: 1) The use of microbead arrays for multiplexed flow cytometry detection of cytokines and botulinum neurotoxin simulant, and 2) a microfluidic platform for capture and separation of different size superparamagnetic nanoparticles followed by on-chip fluorescence detection of the sandwich complex. The methods and automated fluidic systems used for trapping functionalized microbeads will be described. This approach allows sample, assay reagents, and wash solutions to be perfused over a micro-column of beads, resulting in faster and more sensitive assays. The automated fluidic approach resulted in up to five-fold improvements in assay sensitivity/speed as compared to identical assays performed in a typical manual batch mode. A second approach for implementing multiplexed bead-based assays without using flow cytometry detection is currently under development. The goal of the microfluidic-based approach is to achieve rapid (<20 minutes), multiplexed (> 3 bioagents) detection using a simple and low-cost, integrated microfluidic/optical detection platform. Using fiber-optic guided laser-induced fluorescence, assay detection limits were shown to be in the 100’s of picomolar range (10’s of micrograms per liter) for botulinum neurotoxin simulant without any optimization of the microfluidic device or optical detection approach. Video taping magnetic nanoparticle capture and release was used to improve understanding of the process and revealed interesting behavior.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Microfluidic Liquid-Liquid Extraction Chip with Integrated Raman Sensors (Phase I and Phase II Final Report)

As demand for electricity continues to increase worldwide, the world’s nuclear power generating capacity will continue to grow. Nuclear power is the most environmentally benign way of producing electricity on a large scale. The long-term successful use of nuclear power, however, is critically dependent upon adequate and safe processing and disposal of spent nuclear fuels. A very important feature of nuclear energy is that spent fuels can be reprocessed to recover fissile and fertile materials that can then be used as fresh fuel for nuclear power plants. The DOE-NE Fuel Cycle Research and Development (FCR&D) is currently developing nuclear material reprocessing technologies. In a typical nuclear fuel reprocessing system, centrifugal contactors are used as liquid-liquid extraction devices where two immiscible liquids are mixed at high speeds using a rotor, which creates a fine dispersion of droplets of organic phase in an aqueous phase that contains the analyte. Understanding the extraction efficiency at these contactors through modeling and simulation is important in the development of reprocessing technologies and the optimization of current technologies such as the PUREX process. The outcome of this program will be a liquid-liquid microfluidic flow cell chip with embedded spectroscopic sensors for the analysis of extracted analytes. This device will be useful in the optimization of new fuel reprocessing schemes as well as existing reprocessing processes by providing a microfluidic modeling platform to optimize extraction parameters. The Phase I and Phase II work developed a microfluidic chip design that allows integration of Raman and absorption fiber optic probes and successfully demonstrated the feasibility of using Raman and absorption probes to detect key analytes that partition into the aqueous and organic phases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Corrosion of U233-Doped Uranium Oxide using Microfluidics Methods

The aim of work this year has been to investigate the role of alpha (α)-radiation and hydrogen (H 2 ) on the corrosion of uranium oxide (UO 2 ) using a microfluidic device. The microfluidic device, termed the Particle-Attached Microfluidic Electrochemical Cell, (PAMEC), enables monitoring of the UO 2 electrochemical corrosion potential (E corr ) under different environments, including de-aerated conditions and in the presence of dissolved H 2 . The Si 3 N 4 window allows us to study morphological and chemical changes under an electron microscope. We have previously demonstrated that the PAMEC matches the results from bulk electrochemical tests with UO 2 [1]. We used the high specific activity uranium (U) isotope, 233 U, (t 1/2 = 160,000 years) incorporated into UO 2 , to generate a localized a-field. The objective of the experiments were to mimic the radiation environment that would be experience at the surface of aged spent nuclear fuel (SNF) during long-term geologic disposal under anoxic conditions. Wittman et al. [2] predicted that in the presence of a pure a-radiation field and under H 2 conditions, the concentration of the radiolytic oxidant H 2 O 2 would be suppressed or even eliminated. In a UO 2 corrosion experiment this would be exhibited through a lowering of the measured UO 2 corrosion potential compared to identical conditions in the absence of dissolved H 2 . We found that the predictions of Wittman and co-workers were supported and that the corrosion potential of the 233 U-doped UO 2 in solution lowered with presence of H 2 gas and increased in the absence of H 2 , when under anoxic conditions. The PAMEC experiments indicate that H 2 O 2 has been eliminated in a solution sparged with H 2 while exposed to an a-radiation field. The corrosion potential of the a-doped 233 U(10%)- 238 UO 2 in a solution sparged with Ar/H 2 matched the corrosion potential of 238 UO 2 in solution sparged with air. This clearly demonstrated that the H 2 O 2 had been eliminated and that the only oxidant present was O 2 in this system in complete agreement with the modeling results of Wittman et al. These results point to the need to improve the Fuel Matrix Degradation (FMD) Process Model training data set that is being used in the FMD surrogate model that is being developed for the repository program. The incorporation of realistic radiation chemistry will improve the scientific basis for the FMD Model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Functional Imaging of Microbial Interactions With Tree Roots Using a Microfluidics Setup

Coupling microfluidics with microscopy has emerged as a powerful approach to study at cellular resolution the dynamics in plant physiology and root-microbe interactions (RMIs). Most devices have been designed to study the model plant Arabidopsis thaliana at higher throughput than conventional methods. However, there is a need for microfluidic devices which enable in vivo studies of root development and RMIs in woody plants. Here, we developed the RMI-chip, a simple microfluidic setup in which Populus tremuloides (aspen tree) seedlings can grow for over a month, allowing continuous microscopic observation of interactions between live roots and rhizobacteria. We find that the colonization of growing aspen roots by Pseudomonas fluorescens in the RMI-chip involves dynamic biofilm formation and dispersal, in keeping with previous observations in a different experimental set-up. Also, we find that whole-cell biosensors based on the rhizobacterium Bacillus subtilis can be used to monitor compositional changes in the rhizosphere but that the application of these biosensors is limited by their efficiency at colonizing aspen roots and persisting. These results indicate that functional imaging of dynamic root-bacteria interactions in the RMI-chip requires careful matching between the host plant and the bacterial root colonizer.

59 BASIC BIOLOGICAL SCIENCES↗

Blood Plasma Self-Separation Technologies during the Self-Driven Flow in Microfluidic Platforms

Blood plasma is the most commonly used biofluid in disease diagnostic and biomedical analysis due to it contains various biomarkers. The majority of the blood plasma separation is still handled with centrifugation, which is off-chip and time-consuming. Therefore, in the Lab-on-a-chip (LOC) field, an effective microfluidic blood plasma separation platform attracts researchers’ attention globally. Blood plasma self-separation technologies are usually divided into two categories: active self-separation and passive self-separation. Passive self-separation technologies, in contrast with active self-separation, only rely on microchannel geometry, microfluidic phenomena and hydrodynamic forces. Passive self-separation devices are driven by the capillary flow, which is generated due to the characteristics of the surface of the channel and its interaction with the fluid. Comparing to the active plasma separation techniques, passive plasma separation methods are more considered in the microfluidic platform, owing to their ease of fabrication, portable, user-friendly features. We propose an extensive review of mechanisms of passive self-separation technologies and enumerate some experimental details and devices to exploit these effects. The performances, limitations and challenges of these technologies and devices are also compared and discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Recent Results of the Investigation of a Microfluidic Sampling Chip and Sampling System for Hot Cell Aqueous Processing Streams

A Fuel Cycle Research and Development project has investigated an innovative sampling method that could evolve into the next generation sampling and analysis system for metallic elements present in aqueous processing streams. Initially sampling technologies were evaluated and microfluidics sampling chip technology was selected and tested. A conceptual design for a fully automated microcapillary-based system was completed and a robotic automated sampling system was fabricated. The mechanical and sampling operation of the completed sampling system was investigated. In addition, the production of a less expensive, mass produced sampling chip was investigated to avoid chip reuse thus increasing sampling reproducibility/accuracy. The microfluidic-based robotic sampling system’s mechanical elements were tested to ensure analytical reproducibility and the optimum robotic handling of microfluidic sampling chips.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Layer‐by‐Layer Engineered All‐Liquid Microfluidic Chips for Enzyme Immobilization

Abstract Enzyme immobilization in the confines of microfluidic chips, that promote enzyme activity and stability, has become a powerful strategy to enhance biocatalysis and biomass conversion. Here, based on a newly developed all‐liquid microfluidic chip, fabricated by the interfacial assembly of nanoparticle surfactants (NPSs) in a biphasic system, a layer‐by‐layer assembly strategy to generate polysaccharide multilayers on the surface of a microchannel, greatly enhancing the mechanical properties of the microchannel and offering a biocompatible microenvironment for enzyme immobilization, is presented. Using horseradish peroxidase and glucose oxidase as model enzymes, all‐liquid microfluidic enzymatic and cascade reactors have been constructed and the crucial role of polysaccharide multilayers on enhancing the enzyme loading and catalytic efficiency is demonstrated.

Liu, Tan↗