Search NASA⌕ Search

SEARCH · Search NASA

Results for “microgrid controller evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Guided Resilience Self Assessment Application

Reliable electricity access is vital for everything from hospitals to national security. When grid disturbances occur, it is crucial to minimize the amount of time it takes to recover. Grid resiliency considers both the preparation for and recovery from high-impact low-frequency disturbances (HILF) such as weather events and cyber attacks. The Department of Energy (DOE) Wind Energy Technologies Office (WETO) funds the multi-laboratory Microgrids, Infrastructure Resilience, and Advanced Control Launchpad (MIRACL) project to investigate technologies to support and grow distributed wind. Researchers at Idaho National Laboratory (INL) contribute to resilience and cybersecurity efforts for the project, and have produced a resilience framework to evaluate system resilience based on individual system specifications. In order to make this framework easy for anyone to apply, I have coded a web application that allows users to input their power system qualities, goals, and perceived risks and then receive suggestions on how to improve their grid resiliency. The web application follows the seven steps in the planning stage of the framework process, allowing the user to input information about their grid and select from common goals, metrics, and hazards, as well as add their own. The application currently provides information about how to complete each step, requiring minimal prior knowledge of the framework. Future work for this application will include allowing the user to submit line drawings of their system and incorporate modeling tools so that the hazard simulations of applying the framework is completed for the user.

97 MATHEMATICS AND COMPUTING↗

Study of Inverter Control Strategies on the Stability of Microgrids Toward 100% Renewable Penetration

This paper investigates microgrid transient stability with mixed generation - synchronous generator (SG), grid-forming (GFM) and grid-following (GFL) inverters - under increasing penetration levels toward a 100% renewable generation microgrid. Specifically, the dynamics of a microgrid with an SG and GFL inverter(s), an SG with GFM inverter(s), and an SG with GFM and GFL inverters under each penetration are evaluated with an electromagnetic transient study with two critical dynamic events: unplanned islanding and switching in a pumped induction motor load. Analysis and simulation results indicate that the microgrid with GFL inverters running in parallel with the SG can provide a faster power response than the GFM inverters to compensate for the deviations of the frequency and voltage. The scenario with the mixed SG, GFM, and GFL inverter has the best transient and steady-state stability toward 100% inverter-based resource (IBR) penetration. This comprehensive study provides helpful references for microgrid engineers to understand the microgrid stability when facing various choice of installing IBRs (GFL, GFM, or mixed).

droop control↗

Study of Inverter Control Strategies on the Stability of Microgrids Toward 100% Renewable Penetration: Preprint

This paper investigates microgrid transient stability with mixed generation - synchronous generator (SG), grid-forming (GFM) and grid-following (GFL) inverters - under increasing penetration levels toward a 100% renewable generation microgrid. Specifically, the dynamics of a microgrid with an SG and GFL inverter(s), an SG with GFM inverter(s), and an SG with GFM and GFL inverters under each penetration are evaluated with an electromagnetic transient study with two critical dynamic events: unplanned islanding and switching in a pumped induction motor load. Analysis and simulation results indicate that the microgrid with GFL inverters running in parallel with the SG can provide a faster power response than the GFM inverters to compensate for the deviations of the frequency and voltage. The scenario with the mixed SG, GFM, and GFL inverter has the best transient and steady-state stability toward 100% inverter-based resource (IBR) penetration. This comprehensive study provides helpful references for microgrid engineers to understand the microgrid stability when facing various choice of installing IBRs (GFL, GFM, or mixed).

droop control↗

Risk Analysis for Remote Operation of Microreactors

Microreactors are a subset of advanced nuclear reactors that can be factory fabricated, transportable, and self-regulating. They have the potential to be used in microgrids, rural and remote areas, or emergency response applications, replacing fossil fuel sources like diesel generators and enabling sustainable energy generation. In order to make microreactor operation cost-effective, it is likely that remote communications will be needed to reduce the number of personnel required to be on site. While remote operation of energy generation and other industrial control systems is common in other industries, it is not yet adopted in the nuclear community and has many perceived and actual risks. In this paper, the severity of the risks introduced by remote operations for microreactors are explored. The primary changes in the operations involve the addition of a remote communications network and a certification system for data and controls. These changes lend themselves to considerations of cyber risks, whether unintentional or adversarial, but the assessment considers not just cyber risks introduced, but also how physical and human factors-based risks will impact the remote operations system and change the overall risk profile. This initial assessment indicates that there are standard cyber and mitigation measures that can be put in place so the risk of doing remote operations does not dramatically increase compared to local operations. This evaluation is a critical step in the process of evaluating if remote operations of microreactors is a suitable solution to meet future sustainable grid needs

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation: Preprint

This paper presents the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., lost a large generation unit). The NLM engine is a central dispatch control system that provides high-speed cost-optimal coordination of a set of net loads (combination of generation and deferrable loads) connected to the same electrical network. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm. The experimental results indicate that the NLM engine can achieve the targeted system voltage and frequency and balance load and generation to serve the critical facility.

droop control↗

A generic microgrid controller: Concept, testing, and insights

Microgrids have garnered attention in recent years as a way to increase the reliability of the grid, increase the reliability of electricity service to customers, adapt to an increasing percentage of intermittent renewable generation, and serve both customer critical loads and the needs of adjacent communities in the case of emergencies such as natural disasters. One barrier to microgrids is the historic cost and lack of standardization associated with microgrid controllers. To reduce this cost and address standardization, specifications for a Generic Microgrid Controller (GMC) were developed with the goal to facilitate the design and ease of adaptation of microgrid controllers to various microgrids of different sizes and with different resources. A GMC must address two core functions, Transition and Dispatch, as well as several optional higher level functions such as economic dispatch, and renewable and load forecasting. The GMC specifications were demonstrated and evaluated using a commercial simulation platform for two different microgrids, a 20MW-Class community microgrid and a 10MW-Class medical center microgrid. For each microgrid, the GMC was tested in hardware-in-the-loop (HIL) using an OPAL-RT real-time digital simulator, and the two core functions were assessed. The results established that (1) the GMC is successful in seamlessly transitioning the microgrids to and from an islanded mode, (2) a load/generation mismatch at the time of separation depends on the microgrid configuration and must be lower than a specific value determined by simulation testing, and (3) the GMC Dispatch Function response is acceptable in maintaining, in the islanded mode, 60Hz for a range of load changes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Strategies for microgrid operation under real-world conditions

Microgrids are an increasingly relevant technology for integrating renewable energy sources into electricity systems. Based on a microgrid implementation in California, in this study we investigate microgrid operation under real-world conditions. These conditions have not yet been considered in combination and encompass energy charges, demand charges, export limits, as well as uncertainty about future electricity demand and generation in the microgrid. Under these conditions, we evaluate the performance of two frequently applied groups of strategies for microgrid operation. The first group is composed of proactive strategies that optimize decisions based on forecasts of future electricity generation and demand. The second group includes reactive strategies that make operational decisions based exclusively on the current state of the microgrid. We evaluate the performance of the strategies under varying operational parameters, forecast accuracies, and microgrid configurations—well beyond our Californian showcase. Our results confirm the expectation that proactive strategies outperform reactive ones in the majority of settings. Yet, reactive strategies can perform better under short control intervals or under moderate prediction errors of PV generation or demand. Furthermore, the interplay between real-world conditions and operational strategies reveals several additional insights for research on microgrid operation. First, we find that demand charges and export limits decisively affect microgrid performance. Second, the impact of forecast errors is highly non-linear and non-monotonous. Third, escalating negative interactions between forecast errors and demand charges make proactive strategies benefit from longer control intervals. This result is contrary to existing best practice, which promotes short control intervals to minimize the impact of uncertainty.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design Power Control Strategies of Grid-Forming Inverters for Microgrid Application: Preprint

This paper compares two control schemes in the application control layer of a non-PLL grid-forming (GFM) inverter to gain the insights and understanding of how the two schemes affect the dynamic responses of the GFM inverters and the transition operation of microgrids. Both schemes can achieve smooth microgrid transition operation and power tracking, however, the first scheme expects to exhibit more transients due to the feedforward of the inverse dynamic model of the output filter. Simulation results show that both control schemes achieve successful transition operation with smooth transients, and the second control scheme exhibits slightly better transients in the system frequency during islanding operation and the first one has slightly superior transients in the system frequency during reconnection operation. The power tracking performance in the grid-connected mode is evaluated, which shows that the first scheme has better active power tracking and the second one has better reactive power tracking. The analysis and results are useful to develop reliable control schemes for non-PLL GFM inverters because more and more inverters will work as non-PLL grid-forming sources in the future grids due to better stability and reliability.

grid-forming inverter↗

Evaluation of Distributed Power Apportioning with Net Load Management Engine in Microgrids Using Power Hardware-in-the-Loop Simulation

This article presents the performance evaluation of ratio consensus-based distributed power apportioning engine along with centralized net load management (NLM) engine that ensures viable and stable operation of an islanded microgrid. Managing net load variability in a microgrid with high penetrations of uncertain renewable generation and ever-changing load demands is a crucial need in order to ensure viable and stable operation of the microgrid. Centralized “dispatch-rule”-based and/or multi-agent-based distributed control of distributed energy resources (DERs) in microgrid are well accepted for microgrid by adapting ANSI/ISA-95-based hierarchical control architecture. In the application where microgrid network has large geographical span with multiple DERs dispersed in the network, high penetration of uncertain renewable energy resources, and ever-changing load demands, a judicious selection of techniques/solutions for managing net-load resources for maintaining viability and stability is required. With this motivation, this article proposes a novel solution to mitigate the challenges by incorporating a mixed centralized NLM engine and distributed power apportioning control of DERs and loads. A power-hardware-in-the-loop (PHIL) -based experiment is conducted with the centralized NLM engine and the distributed power apportioning engine along with two commercial inverters. The experimental results validates the efficacy of the proposed method in ensuring viability and stability of a microgrid.

hardware-in-the-loop simulation↗

Measuring the value of microgrids: a benefit–cost framework

This study examines the costs and benefits of microgrids under a variety of business models. Many factors complicate a utility-planning benefit–cost framework when evaluating microgrids. For the purposes of this paper, a ‘microgrid’ is a group of interconnected resources and loads sharing a (usually) single point of interconnection with a larger grid, and capable of balancing load and resources when disconnected from the grid, through dispatch of resources and demand control and/or response. Economically, a microgrid can be examined from a variety of perspectives, and the picture is more complex than for typical utility investments. It is Electric Power Research Institute’s intent to provide unbiased and independent analysis of technology applications, examining economic questions from the perspectives of electricity end-consumers and society as a whole. Among the first steps is determining the point of view the analysis is to assume and narrowing down the set of economic questions to be addressed. Since the nature and major purpose of a microgrid is presumably to provide its internal customers with enhanced reliability and resilience, it is important to ask the question of perspective: For whom is the microgrid an economical choice, and compared with what?

Roark, Jeffrey↗

Autonomous Microgrid Restoration Using Grid-Forming Inverters and Smart Circuit Breakers: Preprint

The proliferation of distributed inverter-based resources (IBRs) raises the questions if these IBRs can be used to blackstart microgrids and distribution feeders after major outages. In this paper, we propose and evaluate an autonomous microgrid restoration concept using grid-forming (GFM) IBRs and smart circuit creakers (SCBs). The concept is first explored in simulation platform and then a hardware testbed containing actual GFM inverters is developed to demonstrate these functionalities. A combination of dispatchable virtual oscillator control (dVOC) and droop-based control schemes have been designed for GFM inverter controls in the software simulations and hardware testbed. Subsequently, operation of SCBs using two distinct principles have been demonstrated that can restore or connect portions of the network.

grid reconfiguration↗

Reconfigurable and Dynamic Distribution Systems Enabled Using Self-Sustainable Minimal-Microgrids with Region Based Stability Guarantees

In this paper, a reconfigurable and dynamic distribution system is designed using self-sustainable minimal-microgrids (min-MGs). Particularly, multiple dynamic microgrids are implemented by aggregating local min-MGs in a controllable way to facilitate service restoration at critical grid infrastructures, especially during severe power outages (e.g., those induced by natural disasters). These dynamic microgrids are implemented surrounding inverter interfaced distributed energy resources (DERs) to pick up local critical loads. Stable transient process during neighboring microgrid disconnection and resynchronization is realized by involving additional control terms in the secondary control level. Meanwhile, in order to ensure a stable operation with dynamic topology change, a computationally efficient region-based stability assessment approach is developed to ensure stability guarantees of each inverter dominated min-MG with potential changes of external grids modeled as disturbances. In contrast to conventional point-by-point stability evaluation approaches, the proposed region-based stability analysis can intuitively exhibit the feasible region comprised of stable operating points and identify sufficient stability margin to tolerate disturbances of dynamic system topology variations. Theoretical analysis is verified using simulation in MATLAB/Simulink.

distribution systems↗

A Deep Learning Approach for In-Network Synchrophasor Missing Data Recovery Using Programmable Network Switches

Phasor measurement unit (PMU) networks deliver accurate and timely measurements, which is essential for managing today’s electric power systems. To ensure data quality and enhance the cyber-resilience of PMU networks against malicious attacks and data errors, this study presents an online PMU missing data recovery scheme by leveraging P4 programmable switches. The data plane incorporates a customized PMU protocol parser that abstracts the necessary payload data for recovery. Recovery processes are executed in the control plane using a pre-trained machine learning model. Both traditional and advanced ML models, such as transformer and TimeGPT, are explicitly employed for data prediction. This approach ensures rapid and precise data recovery. Performance evaluations focus on recovery speed and accuracy, using a real dataset from a campus microgrid. With 20% missing PMU data, the mean absolute percentage error for voltage magnitude is 0.0384%, and the phase angle error discrepancy is approximately 0.4064%.

Phasor Measurement Unit, Machine Learning, Program↗

Peer-to-peer communication control for resilient operations of networked cyberphysical systems

This report includes two main accomplishments of the peer-to-peer communication control for resilient operation of networked microgrids project in FY24, which include a scheme for cyberattack-aware coordination of networked microgrids for supporting voltages of bulk power systems and a scheme for price signal-based operations of EV-rich networked microgrids with mixed ownership. First, the cyberattack-aware scheme enables networked microgrids to distributedly determine the amount of reactive power injection to support the voltage of bulk power system (BPS) in a fair manner. In this scheme, a risk-informed algorithm is presented to generate the peer-to- peer (P2P) communication graph with minimal risk of attack on communication links. To deal with cyberattacks on MG controllers, the resilient consensus algorithm (CA) is utilized for MG controllers to robustly estimate the total reactive power headroom, from which the MGs can accurately provide the needed amount of reactive power injection for supporting the voltage of BPS. The CA implementation and performance within the P2P communication framework are demonstrated on the IEEE 39-bus system with 6 microgrids contained in the distribution feeder under different cyberattack scenarios. Second, the price-based scheme enables the usage of the real-time price signal for the operations of electric vehicle (EV)-rich networked-microgrids with mixed ownership, in which not all the microgrids can communicate with the distribution system operator (DSO). In this scheme, a max consensus is introduced to enable the real-time price signal to be propagated from the DSO to all the microgrids, from which each microgrid controller will manage the DERs to balance the load demand and the power injection from the EV charging stations within its microgrid. Numerical results over one day with 288 slots of 5-minute intervals on the modified 123-node test feeder including 3 microgrids with high penetration of EV are presented to evaluate how the price signal affects the operations of networked microgrids under different charging strategies of the EV charging stations. The result indicates that our proposed EVCS (dis)charging strategy, which leverages the flexibility of EVs to support the grid through discharging during peak demand, proves to be a cost-effective solution that reduces operational costs while improving the social welfare of EV charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demonstrating Distribution System Resiliency through Grid-Edge Microgrids, on a Multi-Site Networked Hardware-in-Loop Platform

With the increasing penetration of Distributed Energy Resources (DERs) at the grid-edge, power systems include more energy storage, remote switches, relays, voltage regulators, and other intelligent electronic devices (IED). Effective control of these grid-edge devices by using Advanced Distribution Management Systems (ADMS) can yield substantial improvements to the resiliency and power quality of distribution systems. In this paper, improvements to the resiliency of a distribution system are demonstrated using a multi-site evaluation environment consisting of a real-time Hardware-in-Loop (HIL) setup in which DERs and other IEDs are modeled; and an ADMS which monitors and is able to control the distribution system assets. The HIL model and the ADMS are located 2400 km away, with communication between the sites enabled by a data manager using Distributed Network Protocol 3 (DNP3), demonstrating the system's capabilities even over long distances. After a simulated transmission system failure in the HIL demonstration setup, DERs and other devices are operated to restore critical loads and node voltage profile (to within the 'nominal +/-5%' band) in the distribution system.

ADMS↗

Circulating Current Reduction of Back-to-Back MMC with Advanced Grid-Support Functionalities for Medium-Voltage Applications

A Lyapunov energy function based circulating current reduction scheme for a back to back modular multilevel converter based system for a microgrid application has been proposed in this digest. In order to ensure no circulating or zero sequence currents within the modules, the dynamics from one leg of the converter to the other are evaluated. A Lyapunov energy function is then developed and utilizing the circulating current dynamics of the converter the overall control law is implemented. In this digest a decentralized hierarchical control architecture has been implemented for the main current control; where the outer loop or the central controller implements the higher level grid interconnection functions as per IEEE 1547-2018 standards and the inner loop based on synchronous reference frame implements the current control architecture. The inner loops' outputs are the commanded converter voltages either on either side which are augmented by the Lyapunov energy function based circulating current suppression architecture. To evaluate the efficacy of the overall system, the overall system is modeled around a 300kVA back to back SiC multilevel modular converter used as a direct-connected medium voltage (MV) grid intertie based on MATLAB/Simulink domain. Several important case studies are presented in this paper to prove the effectiveness of the proposed architecture. case study results are presented.

circulating current↗

Multi-time Scale Coordination of Distributed Energy Resources in Isolated Power Systems

In isolated power systems, including microgrids, distributed assets, such as renewable energy resources (e.g. wind, solar) and energy storage, can be actively coordinated to reduce dependency on fossil fuel generation. The key challenge of such coordination arises from significant uncertainty and variability occurring at small time scales associated with increased penetration of renewables. Specifically, the problem is with ensuring economic and efficient utilization of DERs, while also meeting operational objectives such as adequate frequency performance. One possible solution is to reduce the time step at which tertiary controls are implemented and to ensure feedback and look-ahead capability are incorporated to handle variability and uncertainty. However, reducing the time step of tertiary controls necessitates investigating time-scale coupling with primary controls so as not to exacerbate system stability issues. In this paper, an optimal coordination (OC) strategy, which considers multiple time-scales, is proposed for isolated microgrid systems with a mix of DERs. This coordination strategy is based on an online moving horizon optimization approach. The effectiveness of the strategy was evaluated in terms of economics, technical performance, and computation time by varying key parameters that significantly impact performance. The illustrative example with realistic scenarios on a simulated isolated microgrid test system suggests that the proposed approach is generalizable towards designing multi-time scale optimal coordination strategies for isolated power systems.

Mayhorn, Ebony↗

A GENERIC MICROGRID CONTROLLER

The main objective of this project was to develop and test a Generic Microgrid Controller (GMC) that provides (1) seamless islanding and reconnection of the microgrid, (2) efficient, reliable, and resilient operation of the microgrid with the required power quality, whether islanded or grid-connected, (3) existing and future ancillary services to the larger grid, (4) the capability for the microgrid to serve the resiliency needs of participating communities, (5) communication with the electric grid utility as a single controllable entity, and (6) increased reliability, efficiency and reduced emissions. The GMC developed under this project was designed to facilitate the deployment of microgrids, to be easily adapted to various microgrid configurations, and reduce up-front engineering costs associated with the design and development of microgrid controllers. Specifically, the GMC: 1. Provides a control structure amenable to accommodating an array of microgrid configurations and a portfolio of functional requirements; 2. Possesses a high level architecture that can readily be adopted by commercial suppliers; 3. Supports unlimited nesting of conforming microgrid control schemes; 4. Integrates into a full-featured Energy Management System (EMS) as a module. A select set of microgrids, operating a variety of microgrid configurations, served as “collaborating microgrid partners” in the project and assured thereby that the GMC developed under this program can readily be applied to microgrids of different sizes, and equipped with various resources, attributes, and equipment. Collaborating microgrid partners included the UCI Medical Center), the Port of Los Angeles, Port of Long Beach, and the Irvine Ranch Water District. The objectives of the project were achieved in two phases: (Phase I) Research, Development and Design (“Design”), and (Phase II) Testing, Evaluation, and Verification (“TEV”). In Phase I, specifications were developed for the GMC and a detailed test plan was established to test the functional requirements of the GMC. The GMC addresses two core functions, transition and dispatch, as well as several optional higher level functions such as economic dispatch, and renewable and load forecasting.

24 POWER TRANSMISSION AND DISTRIBUTION↗