Search NASA⌕ Search

SEARCH · Search NASA

Results for “microwave absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Steady state temperature profile in a sphere heated by microwaves

A new theory has been developed to calculate the microwave absorption and resultant temperature profile within a sphere positioned in a single mode rectangular cavity. This theory is an extension of a total absorption model based on Mie scattering results. Temperature profiles have been computed for alumina spheres at the center of a rectangular cavity excited in the TM354 mode. Parametric studies reveal significant structure in those profiles under special conditions that are associated with electromagnetic resonances inside the spheres. Anomalous behavior similar to thermal runaway occurs at moderate temperatures when there is enhanced absorption associated with resonant conditions in the sphere.

Barmatz, M.↗

Compositional Evolution of Saturn's Ring: Ice, Tholin, and 'CHIRON'-Dust

We address compositional evolution in planetary ring systems subsequent to meteoroid bombardment. The huge surface area to mass ratio of planetary rings ensures the importance of this process, given currently expected values of meteoroid flux. We developed a model which includes both direct deposition of extrinsic meteoritic 'pollutants', and ballistic transport of the increasingly polluted ring material as impact ejecta. Certain aspects of the observed regional variations in ring color and albedo can be understood in terms of such a process. We conclude that the regional scale color and albedo differences between the C ring and B ring can be understood if all ring material began with the same composition (primarily water ice, based on other data, but colored by tiny amounts of non-icy, reddish absorber) and then evolved entirely by addition and mixing of extrinsic, neutrally colored, highly absorbing material. This conclusion is readily extended to the Cassini Division and its surroundings as well. Typical silicates are unable to satisfy the ring color, spectroscopic, and microwave absorption constraints either as intrinsic or extrinsic non-icy constituents. However, 'Titan Tholin' provides a satisfactory match for the inferred refractive indices of the 'pre-pollution' nonicy ring material. The extrinsic bombarding material is compatible with the properties of Halley or Chiron, but not with the properties of other 'red' primitive objects such as Pholus. We further demonstrate that the detailed radial profile of color across the abrupt B ring - C ring boundary is quite compatible with such a 'pollution transport' process, and that the shape of the profile can constrain key parameters in the model. We use the model to estimate the 'exposure age' of Saturn's rings to extrinsic meteoroid flux. We obtain a geologically young 'age' which is compatible with timescales estimated independently based on the evolution of ring structure due to ballistic transport, and also with other 'short timescales' estimated on the grounds of gravitational torques.

Cuzzi, Jeffrey N.↗

Extraction of Water from Lunar Permafrost

Remote sensing indicates the presence of hydrogen rich regions associated with the lunar poles. The logical hypothesis is that there is cryogenically trapped water ice located in craters at the lunar poles. Some of the craters have been in permanent darkness for a billion years. The presence of water at the poles as well as other scientific advantages of a polar base, have influenced NASA plans for the lunar outpost. The lunar outpost has water and oxygen requirements on the order of 1 ton per year scaling up to as much as 5 tons per year. Microwave heating of the frozen permafrost has unique advantages for water extraction. Proof of principle experiments have successfully demonstrated that microwaves will couple to the cryogenic soil in a vacuum and the sublimed water vapor can be successfully captured on a cold trap. Dielectric property measurements of lunar soil simulant have been measured. Microwave absorption and attenuation in lunar soil simulant has been correlated with measured dielectric properties. Future work will be discussed.

Ethridge, Edwin C.↗

Microwave resonance lamp absorption technique for measuring temperature and OH number density in combustion environments

A simple technique for simultaneous determination of temperature and OH number density is described, along with characteristic results obtained from measurements using a premixed, hydrogen air flat flame burner. The instrumentation is based upon absorption of resonant radiation from a flowing microwave discharge lamp, and is rugged, relatively inexpensive, and very simple to operate.

Lempert, Walter R.↗

Microwave Induced Direct Bonding of Single Crystal Silicon Wafers

We have heated polished doped single-crystal silicon wafers in a single mode microwave cavity to temperatures where surface to surface bonding occurred. The absorption of microwaves and heating of the wafers is attributed to the inclusion of n-type or p-type impurities into these substrates. A cylindrical cavity TM (sub 010) standing wave mode was used to irradiate samples of various geometry's at positions of high magnetic field. This process was conducted in vacuum to exclude plasma effects. This initial study suggests that the inclusion of impurities in single crystal silicon significantly improved its microwave absorption (loss factor) to a point where heating silicon wafers directly can be accomplished in minimal time. Bonding of these substrates, however, occurs only at points of intimate surface to surface contact. The inclusion of a thin metallic layer on the surfaces enhances the bonding process.

Budraa, N. K.↗

Measurement of individual hydrometeor absorption cross sections utilizing microwave cavity perturbation techniques

A technique for measurement of individual hydrometeor absorption cross sections is presented. Cross sections are inferred by inserting the hydrometeor into a high Q resonant cavity and measuring the Q perturbation. Tests were conducted in a 10.64 GHz, TM(010) cavity. Absorption cross sections were measured at room temperature for 0.5 to 2.0 mm water drops, and were found to agree with the Rayleigh theory. Cross sections were also measured as a function of temperature, and from these the dielectric loss term lm(-K) was inferred for supercooled water down to -17 C.

Hansman, R. J., Jr.↗

A cavity type absorption cell for double resonance microwave spectroscopy.

Description of an experimental dual resonant cavity absorption cell for observing microwave spectroscopic double-resonance effects. The device is composed of two Fabry-Perot interferometers excited by independent microwave sources and mounted at right angles in a suitable vacuum enclosure. The pumping transition is modulated by one source and the modulation induced on the rf absorption in the orthogonal cavity is detected.

Lee, M. C.↗

Microwave Resonator Measurements of Atmospheric Absorption Coefficients: A Preliminary Design Study

A preliminary design study examined the feasibility of using microwave resonator measurements to improve the accuracy of atmospheric absorption coefficients and refractivity between 18 and 35 GHz. Increased accuracies would improve the capability of water vapor radiometers to correct for radio signal delays caused by Earth's atmosphere. Calibration of delays incurred by radio signals traversing the atmosphere has applications to both deep space tracking and planetary radio science experiments. Currently, the Cassini gravity wave search requires 0.8-1.0% absorption coefficient accuracy. This study examined current atmospheric absorption models and estimated that current model accuracy ranges from 5% to 7%. The refractivity of water vapor is known to 1% accuracy, while the refractivity of many dry gases (oxygen, nitrogen, etc.) are known to better than 0.1%. Improvements to the current generation of models will require that both the functional form and absolute absorption of the water vapor spectrum be calibrated and validated. Several laboratory techniques for measuring atmospheric absorption and refractivity were investigated, including absorption cells, single and multimode rectangular cavity resonators, and Fabry-Perot resonators. Semi-confocal Fabry-Perot resonators were shown to provide the most cost-effective and accurate method of measuring atmospheric gas refractivity. The need for accurate environmental measurement and control was also addressed. A preliminary design for the environmental control and measurement system was developed to aid in identifying significant design issues. The analysis indicated that overall measurement accuracy will be limited by measurement errors and imprecise control of the gas sample's thermodynamic state, thermal expansion and vibration- induced deformation of the resonator structure, and electronic measurement error. The central problem is to identify systematic errors because random errors can be reduced by averaging. Calibrating the resonator measurements by checking the refractivity of dry gases which are known to better than 0.1% provides a method of controlling the systematic errors to 0.1%. The primary source of error in absorptivity and refractivity measurements is thus the ability to measure the concentration of water vapor in the resonator path. Over the whole thermodynamic range of interest the accuracy of water vapor measurement is 1.5%. However, over the range responsible for most of the radio delay (i.e. conditions in the bottom two kilometers of the atmosphere) the accuracy of water vapor measurements ranges from 0.5% to 1.0%. Therefore the precision of the resonator measurements could be held to 0.3% and the overall absolute accuracy of resonator-based absorption and refractivity measurements will range from 0.6% to 1.

Walter, Steven J.↗

Passive microwave soil moisture research

The AgRISTARS Soil Moisture Project has made significant progress in the quantification of microwave sensor capabilities for soil moisture remote sensing. The 21-cm wavelength has been verified to be the best single channel for radiometric observations of soil moisture. It has also been found that other remote sensing approaches used in conjunction with L-band passive data are more successful than multiple wavelength microwave radiometry in this application. AgRISTARS studies have also improved current understanding of noise factors affecting the interpretability of microwave emission data. The absorption of soil emission by vegetation has been quantified, although this effect is less important than absorption effects for microwave radiometry.

Schmugge, T. J.↗

Continuous-Flow System Produces Medical-Grade Water

A continuous-flow system utilizes microwave heating to sterilize water and to thermally inactivate endotoxins produced in the sterilization process. The system is designed for use in converting potable water to medical-grade water. Systems like this one could be used for efficient, small-scale production of medical- grade water in laboratories, clinics, and hospitals. This system could be adapted to use in selective sterilization of connections in ultra-pure-water-producing equipment and other equipment into which intrusion by microorganisms cannot be tolerated. Lightweight, port - able systems based on the design of this system could be rapidly deployed to remote locations (e.g., military field hospitals) or in response to emergencies in which the normal infrastructure for providing medical-grade water is disrupted. Larger systems based on the design of this system could be useful for industrial production of medical-grade water. The basic microwave-heating principle of this system is the same as that of a microwave oven: An item to be heated, made of a lossy dielectric material (in this case, flowing water) is irradiated with microwaves in a multimode microwave cavity. The heating is rapid and efficient because it results from absorption of microwave power throughout the volume of the lossy dielectric material. In this system, a copper tube having a length of 49.5 cm and a diameter of 2.25 cm serves as both the microwave cavity and the sterilization chamber. Microwave power is fed via a coaxial cable to an antenna mounted inside the tube at mid-length (see figure). Efficient power transfer occurs due to the shift in wavelength associated with the high permittivity of water combined with the strong coupling of 2.45-GHz microwaves with rotational-vibrational transitions of the dipolar water molecule.

Akse, James R.↗

A selective review of ground based passive microwave radiometric probing of the atmosphere

The absorption of the various atmospheric constituents with significant microwave spectra is reviewed. Based on the available data, an estimate is made of the uncertainty in the microwave absorption coefficients of the major constituents, water vapor and oxygen. Then there is an examination of the integral equations which describe the three basic types of observations: measurement of the spectrum of absorption of the sun's radiation by an atmospheric constituent, measurement of the emission spectrum of a constituent, and measurement at one frequency of the zenith angle dependence of the absorption or emission of the atmosphere.

Welch, W. J.↗

A model for atmospheric brightness temperatures observed by the special sensor microwave imager (SSM/I)

A closed-form mathematical model for the atmospheric contribution to microwave the absorption and emission at the SSM/I frequencies is developed in order to improve quantitative interpretation of microwave imagery from the Special Sensor Microwave Imager (SSM/I). The model is intended to accurately predict upwelling and downwelling atmospheric brightness temperatures at SSM/I frequencies, as functions of eight input parameters: the zenith (nadir) angle, the integrated water vapor and vapor scale height, the integrated cloud water and cloud height, the effective surface temperature, atmospheric lapse rate, and surface pressure. It is shown that the model accurately reproduces clear-sky brightness temperatures computed by explicit integration of a large number of radiosonde soundings representing all maritime climate zones and seasons.

Petty, Grant W.↗

Microwave ice prevention

The concept of using microwave energy to provide aircraft ice protection, specifically an anti-icing system, and the feasibility of such a system are discussed. In a microwave anti-icing system impinging supercooled water droplets are heated to above freezing by the resonant absorption of microwave energy located upstream of the aircraft. This process is inherently more efficient than existing anti-icing devices due to the saving of the latent heat of fusion (a substantial 334 joules/gm (80 cal/gm)) and the fact that only the droplets are heated, thereby reducing convective losses to the air.

Hansman, R. J., Jr.↗

Emission, absorption and group delay of microwaves in the atmosphere in relation to water vapour content over the Indian subcontinent

The advent of satellite communication for global coverage has apparently indicated a renewed interest in the studies of radio wave propagation through the atmosphere, in the VHF, UHF and microwave bands. The extensive measurements of atmosphere constituents, dynamics and radio meterological parameters during the Middle Atmosphere Program (MAP) have opened up further the possibilities of studying tropospheric radio wave propagation parameters, relevant to Earth/space link design. The three basic parameters of significance to radio propagation are thermal emission, absorption and group delay of the atmosphere, all of which are controlled largely by the water vapor content in the atmosphere, particular at microwave bands. As good emitters are also good absorbers, the atmospheric emission as well as the absorption attains a maximum at the frequency of 22.235 GHz, which is the peak of the water vapor line. The group delay is practically independent of frequency in the VHF, UHF and microwave bands. However, all three parameters exhibit a similar seasonal dependence originating presumably from the seasonal dependence of the water vapor content. Some of the interesting results obtained from analyses of radiosonde data over the Indian subcontinent collected by the India Meteorological Department is presented.

Sen, A. K.↗

Formaldehyde monitor for automobile exhausts

Device makes use of microwave spectral absorption in low-Q resonant Stark cell, and indications are that ultimate sensitivity of instrument is within 100 parts per billion of formaldehyde. Microwave source is very small and requires only six-volt dc bias for operation. Coarse tuning is accomplished mechanically and fine tuning by adjusting dc-bias voltage.

Easley, W. C.↗