Search NASA⌕ Search

SEARCH · Search NASA

Results for “microwave load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Tunable Microstrip Filters Using Selectively Etched Ferroelectric Thin-Film Varactors for Coupling

We report on the use of patterned ferroelectric films to fabricate proof of concept tunable one-pole microstrip filters with excellent transmission and mismatch/reflection properties at frequencies up to 24 GHz. By controlling the electric field distribution within the coupling region between the resonator and input/output lines, sufficiently high loaded and unloaded Q values are maintained so as to be useful for microstrip filter design, with low mismatch loss. In the 23 - 24 GHz region, the filter was tunable over a 100 MHz range, the loaded and unloaded Q values were 29 and 68, respectively, and the reflection losses were below -16 dB, which demonstrates the suitability of these films for practical microwave applications.

Mueller, Carl H.↗

Microwave power transmission system wherein level of transmitted power is controlled by reflections from receiver

A microwave, wireless, power transmission system is described in which the transmitted power level is adjusted to correspond with power required at a remote receiving station. Deviations in power load produce an antenna impedance mismatch causing variations in energy reflected by the power receiving antenna employed by the receiving station. The variations in reflected energy are sensed by a receiving antenna at the transmitting station and used to control the output power of a power transmitter.

Robinson, W. J., Jr.↗

DSN Monitor and Control System, Mark III-80

The Deep Space Network monitor and control system, Mark III-80 is described. The major implementations required to evolve from the Mark III-78 to the Mark III-80 configuration are identified. The affected facilities are the deep space stations and the network operations control center (NOCC). At the deep space stations a stand-alone host processor is implemented. Included are software (host software) changes which provide downline loading to the stand-alone host processor from a disc unit of any idle data system computer. At deep space stations with a 34 m antenna, the microwave subsystem is provided with an interface which allows remote configuration selection at the central monitor and control operator's position. In the NOCC, software changes are implemented to provide precision power monitor and GCF monitor displays.

Leflang, J. G.↗

Submillimeter and millimeter wave characterization of absorbing materials

Several microwave absorbers have been characterized in terms of transmittance and reflectance at frequencies between 35 GHz and 3 THz. The materials studied were a series of iron-loaded cast epoxy absorbers known as Eccosorb. Measurements show that reflectance and absorption coefficient increase with the iron density. A dramatic decrease, by as much as a factor of 2, in absorption coefficient was observed when the samples were cooled from ambient to cryogenic temperatures. A blackbody calibrator to be operated at liquid helium temperature was constructed using the measured optical constants for these absorbers. The measured absorption coefficient for cold Eccosorb CR-110 is within 20 percent of that reported recently by Peterson and Richards.

Hemmati, H.↗

An Ultra-Wideband, Microwave Radar for Measuring Snow Thickness on Sea Ice and Mapping Near-Surface Internal Layers in Polar Firn

Sea ice is generally covered with snow, which can vary in thickness from a few centimeters to >1 m. Snow cover acts as a thermal insulator modulating the heat exchange between the ocean and the atmosphere, and it impacts sea-ice growth rates and overall thickness, a key indicator of climate change in polar regions. Snow depth is required to estimate sea-ice thickness using freeboard measurements made with satellite altimeters. The snow cover also acts as a mechanical load that depresses ice freeboard (snow and ice above sea level). Freeboard depression can result in flooding of the snow/ice interface and the formation of a thick slush layer, particularly in the Antarctic sea-ice cover. The Center for Remote Sensing of Ice Sheets (CReSIS) has developed an ultra-wideband, microwave radar capable of operation on long-endurance aircraft to characterize the thickness of snow over sea ice. The low-power, 100mW signal is swept from 2 to 8GHz allowing the air/snow and snow/ ice interfaces to be mapped with 5 c range resolution in snow; this is an improvement over the original system that worked from 2 to 6.5 GHz. From 2009 to 2012, CReSIS successfully operated the radar on the NASA P-3B and DC-8 aircraft to collect data on snow-covered sea ice in the Arctic and Antarctic for NASA Operation IceBridge. The radar was found capable of snow depth retrievals ranging from 10cm to >1 m. We also demonstrated that this radar can be used to map near-surface internal layers in polar firn with fine range resolution. Here we describe the instrument design, characteristics and performance of the radar.

Snow Cover↗

Soil Moisture Active/Passive (SMAP) L-Band Microwave Radiometer Post-Launch Calibration Upgrade

Current performance and existing problems in SMAP radiometer L1B_TB version 3 data product are described. The post-launch calibration algorithm has been updated by calibrating the three calibration parameters (the equivalent noise temperature of the noise diode, the offset of the reference load, and the antenna gain) jointly by using the global ocean and CS with both 110o and 180o pitch maneuvers after the reflector emissivity is calibrated. The results show that both calibration drift during eclipse season and bias over CS are removed. The RMSDs of the calibration drift over both the global ocean and CS are less than 0.1 K, and the goals of the calibration algorithm upgrade are achieved for coming L1B_TB version 4 data release.

Validation↗

Analysis of radiometer calibration effects with TOUCHSTONE

The microwave circuit analysis program TOUCHSTONE is used to study two effects of importance in radiometer calibration. The two effects are impedance mismatches at the antenna-air and cold load-air interfaces and dissipatives losses, which radiate thermal noise into the system. The results predicted by TOUCHSTONE are shown to be in very close agreement with earlier results obtained by purely analytical methods. The techniques used in establishing the circuit models and in processing the resulting data are described in detail.

Stanley, William D.↗

HRMS sky survey wideband feed system design for DSS 24 beam waveguide antenna

The High-Resolution Microwave Survey (HRMS) Sky Survey project will be implemented on the DSS 24 beam waveguide (BWG) antenna over the frequency range of 2.86 to 10 GHz. Two wideband, ring-loaded, corrugated feed horns were designed to cover this range. The horns match the frequency-dependent gain requirements for the DSS 24 BWG system. The performance of the feed horns and the calculated system performance of DSS 24 are presented.

Stanton, P. H.↗

Process Produces Low-Secondary-Electron-Emission Surfaces

Textured carbon layer applied to copper by sputtering. Carbon surface characterized by dense, random array of needle-like spires or peaks that extend perpendicularly from local copper surface. Spires approximately 7 micrometers in height and spaced approximately 3 micrometers apart, on average. Copper substrate essentially completely covered by carbon layer, is tenacious and not damaged by vibration loadings representative of multistage depressed collector (MDC) applications. Process developed primarily to provide extremely low-secondary-electron-emission surface for copper for use as highefficiency electrodes in MDC's for microwave amplifier traveling-wave tubes (TWT's). Tubes widely used in space communications, aircraft, and terrestrial applications.

Curren, A. N.↗

Helium Pressure Shift of the Hyperfine Clock Transition in Hg-201(+)

There are two stable odd isotopes of mercury with singly ionized hyperfine structure suitable for a microwave atomic clock: Hg-199(+) and Hg-201(+). We are investigating the viability of a trapped ion clock based on Hg-201(+) in a configuration that uses a buffer gas to increase ion loading efficiency and counter ion heating from rf trapping fields. Traditionally, either helium or neon is used as the buffer gas at approx. 10(exp -5) torr to confine mercury ions near room temperature. In addition to the buffer gas, other residual background gasses such as H2O, N2, O2, CO, CO2, and CH2 may be present in trace quantities. Collisions between trapped ions and buffer gas or background gas atoms/molecules produce a momentary shift of the ion clock transition frequency and constitute one of the largest systematic effects in this type of clock. Here we report an initial measurement of the He pressure shift in Hg-201(+) and compare this to Hg-199(+).

Larigani, S. Taghavi↗

Remote Strain Sensing of CFRP Using Microwave Frequency Domain Reflectometry

NASA's Advanced Composites Project is investigating technologies that increase automated remote inspection of aircraft composite structures. Therefore, microwave Frequency Domain Reflectometry (FDR) is being investigated as a method of enabling rapid remote measurement of strain occurring at the first ply of a composite fiber reinforced polymer (CFRP) structure using Radio Frequency (RF) Electro-Magnetic (EM) radiation. While microwave reflectometry has been used to detect disbonds in CFRP structures, its use in detecting strain has been limited. This work will present data demonstrating the measurement of the reactance changes due to loading conditions that are indicative of strain in a CFRP structure. In addition, the basic EM signature will be presented along with an analysis of temperature and humidity effects.

Wilson, William C.↗

Power combining in an array of microwave power rectifiers

This work analyzes the resultant efficiency degradation when identical rectifiers operate at different RF power levels as caused by the power beam taper. Both a closed-form analytical circuit model and a detailed computer-simulation model are used to obtain the output dc load line of the rectifier. The efficiency degradation is nearly identical with series and parallel combining, and the closed-form analytical model provides results which are similar to the detailed computer-simulation model.

Gutmann, R. J.↗

Detecting Anthropogenic Impacts on Lightning: Is There an Obvious Signal?

Bell et al. inferred the presence of increased (decreased) summer rainfall and storm heights over the southern tier (off the east coast) of the continental U.S. (CONUS) during the midweek. Amongst other data sources, the Bell et al. study employed Tropical Rainfall Measurement Mission (TRMM) passive microwave and precipitation radar data to reach these conclusions. Importantly, to explain the midweek increases in rainfall and storm echo top heights Bell et al. invoked the presence of anthropogenic influences via increased aerosol loading present in the middle of the work week. Conversely, Schultz et al. argue against the Bell et al. findings, noting that no significant trend in rainfall (amount or occurrence) can be detected in rain gauge data collected from 219 surface observing stations over a 42 year period. Based on previously suggested impacts of enhanced aerosol concentrations on precipitation microphysics and in particular, the ice phase, the results of Bell et al. suggest that in addition to the rainfall signal there may be a detectable response in lightning frequency (to the extent that the aerosol hypothesis invoked is valid). This study examines TRMM Lightning Imaging Sensor observations to detect both daily increases and decreases of lightning over the CONUS and neighboring ocean regions and further examines the possibility (through observations) of systematic direct impacts on lightning activity associated with large city locations.

Petersen, Walter A.↗

Thermionic cathode life-test studies

A NASA-Lewis Research Center program for life testing commercial, high-current-density thermionic cathodes has been in progress since 1971. The purpose of the program is to develop long-life power microwave tubes for space communications. Four commercial-type cathodes are being evaluated in this investigation. They are the 'Tungstate', 'S' type, 'B' type, and 'M' type cathodes, all of which are capable of delivering 1 A/ sq cm or more of emission current at an operating temperature in the range of 1000-1100 C. The life test vehicles used in these studies are similar in construction to that of a high-power microwave tube and employ a high-convergence electron-gun structure; in contrast to earlier studies that used close-space diodes. These guns were designed for operation at 2 A/sq cm of cathode loading. The 'Tungstate' cathodes failed at 700 h or less and the 'S' cathode exhibited a lifetime of about 20,000 h. One 'B' cathode has failed after 27,000 h, the remaining units continuing to operate after up to 30,000 h. Only limited data are now available for the 'M' cathode, because only one has been operated for as long as 19,000 h. However, the preliminary results indicate the emission current from the 'M' cathode is more stable than the 'B' cathode and that it can be operated at a true temperature approximately 100 C lower than for the 'B' cathode.

Forman, R.↗

Investigation of control, display, and crew-loading requirements for helicopter instrument approach

A ground simulation experiment was conducted on a flight simulator for advanced aircraft to investigate the influence and interaction of flight-control system, flight-director display, and crew-loading situation on helicopter flying qualities during terminal-area operations in instrument conditions. Six levels of control complexity were implemented on a representative helicopter model. The six levels of augmentation were examined with display variations consisting of raw elevation and azimuth data only and of raw data plus one-, two-, and three-cue flight directors. Crew-loading situations simulated for the control-display combinations were dual-pilot operation and single-pilot operation. Four pilots performed a total of 150 evaluations of combinations of these parameters for a representative microwave landing system approach task. Pilot rating results indicated the existence of a control display trade-off for ratings of satisfactory, whereas ratings of adequate-but-unsatisfactory depended primarily on the control system; the control system required for ratings of adequate-but-unsatisfactory was clearly more complex for the single-pilot situation than that for the dual-pilot situation.

Lebacqz, J. V.↗

Mirror Illumination and Spillover Measurements of the Atacama Cosmology Telescope

The Atacama Cosmology Telescope (ACT) is a 6 m telescope designed to map the Cosmic Microwave Background (CMB) simultaneously at 145 GHz, 220GHz and 280GHz, The receiver in ACT, the Millimeter Bolometer Array Camera, features 1000 TES bolometers in each band, The detector performance depends critically on the total optical loading, requiring the spmover contributions from the optics to be minimal. This inspired the use of a cold Lyot stop to limit the illumination of the primary and the use of guard rings surrounding the primary and secondary reflectors. Here, we present a direct measurement of the illumination aperture for both reflectors and of the attenuation level outside the main optical path. We used a 145 GHz, 1 m W source and a chopper wheel to produce a time-varying signal with a broad heam proflle, We sampled the response of the camera for different locations of the source, placed in front and beside the primary and secondary mirrors. The aperture of the primary was measured to be 5,72 plus or minus 0,17m in diameter (95 plus or minus 3% of its geometrical size), while the aperture of the secondary yielded 2 plus or minus 0.12m in diameter. Both apertures are consistent with the optical design. Comparing to previous measurements of the beam solid angle from planet observations, we estimate an optical efficiency of 72.3 plus or minus 4,8%. We found that the attenuation outside the primary aperture was -16 plus or minus 2dB, which is below the theoretical expectations, and -22 plus or minus 1 dB outside the secondary aperture, which is consistent with simulations. These results motivated the extension of the baffles surrounding the secondary mirror, with the following reduction in detector optical loading from 2,24 pW to 188pW.

Gallardo, Patricio↗

Airplane Ice Detector Based on a Microwave Transmission Line

An electronic instrument that could detect the potentially dangerous buildup of ice on an airplane wing is undergoing development. The instrument is based on a microwave transmission line configured as a capacitance probe: at selected spots, the transmission-line conductors are partly exposed to allow any ice and/or liquid water present at those spots to act as predominantly capacitive electrical loads on the transmission line. These loads change the input impedance of the transmission line, as measured at a suitable excitation frequency. Thus, it should be possible to infer the presence of ice and/or liquid water from measurements of the input impedance and/or electrical parameters related to the input impedance. The sensory transmission line is of the microstrip type and thus thin enough to be placed on an airplane wing without unduly disturbing airflow in flight. The sensory spots are small areas from which the upper layer of the microstrip has been removed to allow any liquid water or ice on the surface to reach the transmission line. The sensory spots are spaced at nominal open-circuit points, which are at intervals of a half wavelength (in the transmission line, not in air) at the excitation frequency. The excitation frequency used in the experiments has been 1 GHz, for which a half wavelength in the transmission line is .4 in. (.10 cm). The figure depicts a laboratory prototype of the instrument. The impedance-related quantities chosen for use in this version of the instrument are the magnitude and phase of the scattering parameter S11 as manifested in the in-phase (I ) and quadrature (Q) outputs of the phase detector. By careful layout of the transmission line (including the half-wavelength sensor spacing), one can ensure that the amplitude and phase of the input to the phase detector keep shifting in the same direction as ice forms on one or more of the sensor areas. Although only one transmission-line sensor strip is used in the laboratory version, in a practical application, it could be desirable to install multiple strips on different areas to detect localized icing. In that case, a multiplexer should be used to connect the various strips to the phase detector for sequential measurements. Experiments have been performed with freezing and thawing of water and of water/glycol mixtures. The experiments have shown that, whether or not glycol is present, it is possible to distinguish between liquid water and ice via the I and Q outputs; in particular, the equipment can be adjusted so that when water freezes, I decreases and Q increases. With respect to the operation of this instrument, the main effect of glycol is to increase the freezing or thawing time.

Ngo, Phong↗