Search NASA⌕ Search

SEARCH · Search NASA

Results for “millimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Feasibility Study of Millimeter Wave Radars For Safeguards Applications

Containment and surveillance are fundamental measures in nuclear safeguards. Techniques such as video surveillance and laser curtain for containment provide effective monitoring in areas where maintaining continuity of knowledge is required. These systems, however, can be susceptible to loss of monitoring capabilities under certain environmental conditions such as poor visibility (i.e. low light conditions, smoke, fog, etc.) or extended power loss past the duration that the backup power system is designed for. Brookhaven National Laboratory has been investigating the feasibility of millimeter waves (mmWave) as a new perimeter seal in which radio frequency waves in the range of 60-64 GHz are used to detect and monitor objects of interest. Signals in this frequency range are not susceptible to environmental conditions. For proof-of-concept tests, mmWave sensors from Texas Instruments (TI), specificallyIWR6843, are used in a test bed at BNL's Waste Management facility to simulate the operations at nuclear facilities. The unique design of TI mmWave sensors requires less memory and power consumption compared to counterpart systems. These devices are capable of exporting 3D point-cloud data, which is visualized graphically and compared to videos recorded at the same time to validate the performance of the mmWave sensor. A set of experiments were planned to test the feasibility of the mmWave in this application, including monitoring static containers in a storage area and detecting intrusions at the boundaries of the area. In addition, the experiments also identify potential blind spots relative to sensor position and utilize multiple operating sensors simultaneously to reduce or eliminate such blind spots. The optimal positioning of multiple sensors was determined for the experimental room configuration. In this paper, we will discuss the details of this novel perimeter sealing concept and present the test results.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Magnetic nanostructures and composites for millimeter wave absorption

A product includes a nanostructure having a core and a shell. The core has a coercive field of at least 3 kOe and the shell has a saturation magnetization of at least 50 emu per gram. A product includes a nanostructure having a core and a shell. The shell has a coercive field of at least 3 kOe and the core has a saturation magnetization of at least 50 emu per gram. A method includes forming core/shell nanostructures and forming millimeter wave absorbers including the core/shell nanostructures and a support structure.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fabrication of a Monolithic 5-Meter Aluminum Reflector for Millimeter-Wavelength Observations of the Cosmic Microwave Background

We have demonstrated the fabrication of a monolithic, 5-meter diameter, aluminum reflector with 17.4 $\mu$m RMS surface error. The reflector was designed to avoid the problem of pickup due to scattering from panel gaps in a large, millimeter-wavelength telescope that will be used for measurements on the cosmic microwave background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systems, devices, and methods for authenticating millimeter wave devices

Systems, devices, and methods are described for millimeter wave device authentication. A system may include one or more access points. Each access point of the one or more access points is configured to extract, from one or more beam patterns generated via a client device, a beam feature associated with the client device. Each access point may also be configured to transmit the beam feature. The system may also include a server communicatively coupled to the one or more access points and including a database for storing known beam features. The server may be configured to receive the beam feature associated with the client device from at least one access point of the one or more access points. Also, the server may be configured to authenticate the client device in response to the received beam feature matching a known beam feature stored in the at least one database.

Bhuyan, Arupjyoti↗

SPT-3G D1: Maps of the millimeter-wave sky from 2019 and 2020 observations of the SPT-3G Main field

Maps of the sky in millimeter wavelengths contain rich information on cosmology through anisotropies of the cosmic microwave background (CMB). Creating multifrequency sky maps of anisotropies in the $I$, $Q$, and $U$ Stokes parameters is one of the first steps of CMB cosmology analyses. In this work, we describe the production and validation of a set of sky maps from the South Pole Telescope's third-generation camera, SPT-3G. The maps are from data taken in frequency bands centered at 95, 150, and 220 GHz and taken during the first two years, 2019 and 2020, of the SPT-3G Main survey, which covers $4\%$ of the sky. We applied high-pass filters to time series of individual detectors and binned the filtered time series samples into map pixels. After that, we calibrated and cleaned the maps to reduce known systematic errors. In addition, we searched for other systematic errors through null tests and mitigated a significant systematic error detected therein. The white noise levels of the full-depth maps of the $I$ Stokes parameter are $5.4$, $4.4$, and $16.2$$\mathrm{μK}$-$\mathrm{arcmin}$ in the 95, 150, and 220 GHz bands, respectively, and $8.4$, $6.6$, and $25.8$$\mathrm{μK}$-$\mathrm{arcmin}$ for $Q/U$. These maps are the deepest to date used for measurements of mid-to-high-$\ell$ primary temperature and $E$-mode polarization CMB anisotropies, and reconstructions of the CMB gravitational lensing potential. We make these maps and supporting data products publicly accessible.

Quan, W. [Argonne (main); Chicago U., EFI; Chicago↗

Atmospheric Modeling and Denoising for Millimeter-Wave Line Intensity Mapping

Line-intensity mapping (LIM) offers a promising approach to mapping large-scale cosmic structure, and the greatest obstacle for ground-based observations at millimeter wavelengths is foreground contamination from atmospheric emission. In this work, we present a simulation and denoising framework designed to isolate and subtract atmospheric fluctuations from LIM data, modeled after the instrument parameters of the South Pole Telescope Summertime Line Intensity Mapper (SPT-SLIM). We generate mock observations spanning 125-175 GHz containing cosmic signals, precipitable water vapor screens, ice crystal fluctuations, and photon noise. We then implement a spatial-spectral atmospheric removal pipeline combining per-pixel linear template regression with a two-dimensional Fourier-domain filter. The framework is evaluated under simulated conditions in the South Pole and the Atacama Desert across three key metrics: cosmic signal preservation, foreground subtraction efficiency, and instrument noise injection. Our pipeline achieves atmospheric suppression at large spatial scales, and these results establish a physically grounded foundation for atmosphere removal in ground-based LIM data collection.

Saye, L. K. [UC, Berkeley (main)] (ORCID:000900078↗

Polarization Angle Swings in Blazars Detected in the Millimeter-wave with the South Pole Telescope

We present the first systematic search for electric vector position angle (EVPA) swings in the millimeter-wave (mm-wave) emission of blazars, using five years of observations from the South Pole Telescope SPT-3G camera at 95 and 150 GHz, and investigate their connection to gamma-ray flares. Of the 168 bright sources in the ~1500 square degrees SPT-3G Main Field, eight have sufficient polarization signal-to-noise for reliable EVPA measurement, four of which have continuous Fermi LAT gamma-ray detections. We detect EVPA swings in all four gamma-ray-active blazars and in none of the remaining four, consistent with the established connection between EVPA swings and high-energy emission seen at optical wavelengths. The observed swing amplitudes and rotation rates are smaller than those found in optical studies, consistent with mm-wave EVPA variability being slower than at shorter wavelengths. Random walk simulations of the polarization angle using a multi-cell model fail to reproduce both the number, amplitude, and duration of the observed swings, suggesting that this mechanism is insufficient to explain the observed swing population. Analysis of EVPA variability on one-week timescales is consistent with the anti-correlation between polarization degree and EVPA rotation rate previously observed at optical wavelengths. Of the 14 detected swings, eight are within 30 days of a gamma-ray flare. While many individual swing-flare associations are found to have a very low probability of happening by chance, the full ensembles of 95 and 150 GHz swing time lags with respect to gamma-ray flares are found to be consistent with random coincidence.

Simpson, A. [Chicago U., Astron. Astrophys. Ctr.; ↗

Measurement of Dielectric Loss in Silicon Nitride at Centimeter and Millimeter Wavelengths

This work presents a suite of measurement techniques for characterizing the dielectric loss tangent across a wide frequency range from similar to 1 GHz to 150 GHz using the same test chip. In the first method, we fit data from a microwave resonator at different temperatures to a model that captures the two-level system (TLS) response to extract and characterize both the real and imaginary components of the dielectric loss. The inverse of the internal quality factor is a second measure of the overall loss of the resonator, where TLS loss through the dielectric material is typically the dominant source. The third technique is a differential optical measurement at 150 GHz. The same antenna feeds two microstrip lines with different lengths that terminate in two microwave kinetic inductance detectors (MKIDs). The difference in the detector response is used to estimate the loss per unit length of the microstrip line. Our results suggest a larger loss for SiNx at 150 GHz of tan delta similar to 4 x 10(-3) compared to 2.0 x 10(-3) and greater than or similar to 1 x 10(-3) measured at similar to 1 GHz using the other two methods. These measurement techniques can be applied to other dielectrics by adjusting the microstrip lengths to provide enough optical efficiency contrast and other mm/sub-mm frequency ranges by tuning the antenna and feedhorn accordingly.

Dielectrics loss↗

Cost and Time Effective Lithography of Reusable Millimeter Size Bone Tissue Replicas With Sub‐15 nm Feature Size on A Biocompatible Polymer

Abstract The ability to replicate the microenvironment of biological tissues creates unique biomedical possibilities for stem cell applications. Current fabrication methods are limited by either the control on feature size and shape, or by the throughput and size of the replicas. Here, a novel platform is reported that combines thermal scanning probe lithography (tSPL) with innovative methodologies for the low‐cost and high‐throughput nanofabrication of large area quasi‐3D bone tissue replicas with high fidelity, sub‐15 nm lateral precision, and sub‐2 nm vertical resolution. This bio‐tSPL platform features a biocompatible polymer resist that withstands multiple cell culture cycles, allowing the reuse of the replicas, further decreasing costs and fabrication times. The as‐fabricated replicas support the culture and proliferation of human induced mesenchymal stem cells, which display broad therapeutic and biomedical potential. Furthermore, it is demonstrated that bio‐tSPL can be used to nanopattern the bone tissue replicas with amine groups, for subsequent tissue‐mimetic biofunctionalization. The achieved level of time and cost‐effectiveness, as well as the cell compatibility of the replicas, make bio‐tSPL a promising platform for the production of tissue‐mimetic replicas to study stem cell‐tissue microenvironment interactions, test drugs, and ultimately harness the regenerative capacity of stem cells and tissues for biomedical applications.

Liu, Xiangyu↗

Millimeter-Thick Liquid Crystalline Elastomer Actuators Prepared by-Surface-Enforced Alignment

Here, liquid crystalline elastomers (LCE) are thermally cyclable, compliant actuators with compelling mechanical properties. The large and programmable deformation of LCE has led to numerous functional examinations spanning optics, medical devices, and robotics. A well-established method to prepare complex LCE actuators is to utilize surface-enforced photoalignment. Herein, a facile and scalable approach is reported to circumvent the physical limits of surface-enforced alignment (e.g., samples that are 50 µm or less) to amplify the achievable force output in LCE. Applying an approach termed direct layering, the thermomechanical response of LCE elements prepared with +1 disclination patterns in a range of compositions and thicknesses is contrasted. The design and preparation of +1 disclination patterns and arrays is explored to assess the contribution of sample geometry and overlap to deformation and force output. The methodology detailed in this contribution allows for the preparation of elements ≈1 mm in thickness that are capable of actuating large objects. Furthermore, the fabrication of these elements uniquely enables the realization of mechanical instabilities to hasten the actuation rate in response to thermal change and to enable leaping.

36 MATERIALS SCIENCE↗

Transfer of Millimeter‐Scale Strained Multiferroic Epitaxial Thin Films on Rigid Substrates via an Epoxy Method Producing Magnetic Property Enhancement

The demonstration of epitaxial thin film transfer has enormous potential for thin film devices free from the traditional substrate epitaxy limitations. However, large-area continuous film transfer remains a challenge for the commonly reported polymer-based transfer methods due to bending and cracking during transfer, especially for highly strained epitaxial thin films. In this work, a new epoxy-based, rigid transfer method is used to transfer films from an SrTiO 3 (STO) growth substrate onto various new substrates, including those that will typically pose significant problems for epitaxy. An epitaxial multiferroic Bi 3 Fe 2 Mn 2 O x (BFMO) layered supercell (LSC) material is selected as the thin film for this demonstration. The results of surface and structure studies show an order of magnitude increase in the continuous area of transferred films when compared to previous transfer methods. The magnetic properties of the BFMO LSC films are shown to be enhanced by the release of strain in this method, and ferromagnetic resonance is found with an exceptionally low Gilbert damping coefficient. The large-area transfer of this highly strained complex oxide BFMO thin film presents enormous potential for the integration of many other multifunctional oxides onto new substrates for future magnetic sensors and memory devices.

bismuth oxides↗

Plastic Laminate Antireflective Coatings for Millimeter-Wave Optics in BICEP Array

The BICEP/Keck series of experiments target the cosmic microwave background at degree-scale resolution from the South Pole. Over the next few years, the “Stage-3” BICEP Array (BA) telescope will improve the program’s frequency coverage and sensitivity to primordial B-mode polarization by an order of magnitude. The first receiver in the array, BA1, began observing at 30/40 GHz in early 2020. The next two receivers, BA2 and BA3, are currently being assembled and will map the southern sky at frequencies ranging from 95 to 150 GHz. Common to all BA receivers is a refractive, on-axis, cryogenic optical design that focuses microwave radiation onto a focal plane populated with antenna-coupled bolometers. High-performance antireflective coatings up to 760 mm in aperture are needed for each element in the optical chain, and must withstand repeated thermal cycles down to 4 K. Here, in this work, we present the design and fabrication of the 30/40 GHz anti-reflection coatings for the recently deployed BA1 receiver, with indices matched to its various polyethylene, nylon and alumina optical components. We describe an epoxy coating technique designed for alumina optics, which achieves better than 80% transmission at room temperature. For polyethylene optical elements, we present a new heat-compression approach that allows low-density polytetrafluoroethylene AR layers to reach sub-percent reflected power. We describe the planned use of these methods for the next BA cryostats, which may inform technological choices for future small-aperture telescopes of the CMB-S4 experiment.

79 ASTRONOMY AND ASTROPHYSICS↗