Search NASA⌕ Search

SEARCH · Search NASA

Results for “millimeter wave radiometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Active and Passive 3D Vector Radiative Transfer with Preferentially-Aligned Ice Particles

For the purposes of interpreting active (radar) and passive (radiometer) microwave and millimeter wave remote sensing data, we have constructed a consistent radiative transfer modeling framework to simulate the responses for arbitrary sensors with differing sensing geometries and hardware configurations. As part of this work, we have implemented a recent method for calculating the electromagnetic properties of individual ice crystals and snow flakes. These calculations will allow us to exploit polarized remote sensing observations to discriminate different particles types and elucidate dynamics of cloud and precipitating systems.

Adams, Ian S.↗

Millimeter-wave imaging sensor

A scanning 3-mm radiometer system has been built and used on a helicopter to produce moderate-resolution (0.5 deg) images of the ground. This millimeter-wave sensor can be used for a variety of remote-sensing applications and produces images through clouds, smoke, and dust when visual and IR sensors are not usable. The system is described and imaging results are presented.

Wilson, W. J.↗

Millimeter-wave sensor image enhancement

Images from an airborne, scanning radiometer operating at a frequency of 98 GHz have been analyzed. The millimeter-wave images were obtained in 1985-1986 using the JPL millimeter-wave imaging sensor. The goal of this study was to enhance the information content of these images and make their interpretation easier. A visual-interpretative approach was used for information extraction from the images. This included application of nonlinear transform techniques for noise reduction and for color, contrast, and edge enhancement. Results of using the techniques on selected millimeter-wave images are discussed.

Wilson, William J.↗

HAMSR - The High Altitude MMIC Sounding Radiometer

WAMSR is a millimeter wave atmospheric temperature and humidity sounder that utilizes state of the art technology to enable substantial reductions in size and mass while at the same time achieve improved measurement sensitivity and accuracy. It is the first such instrument to use receivers based entirely on newly developed monolithic microwave integrated circuit technology. Sponsored by the NASA Instrument Incubator Program, HAMSR has been under development for the past 2 112 years. The first science mission takes place in Florida this summer, where HAMSR is deployed on the NASA ER-2 during the CAMEX-4 hurricane field campaign and will provide core atmospheric soundings to a number of investigators. HAMSR represents the next generation of microwave sounders.

remote sensing↗

ROCKETMAS: A sounding-rocket-based remote sensing measurement of mesospheric water vapor and ozone

The ROCKETMAS rocketborne technique, based on the shuttle-borne millimeter wave atmospheric sounder (MAS), to obtain water vapor and ozone measurements with vertical resolution, is described. The concentrations of mesospheric water vapor and ozone are not well known, yet both contribute significantly to the chemical and radiative structure of that region. In situ measurements of water vapor are difficult to make because water that was absorbed on the instrument surfaces outgasses in space and contaminates the local environment of the payload. However, a remote sensing technique that uses a long pathlength through the atmosphere greatly reduces the effect of such local contamination. The 183.3 GHz line of water vapor and 184.4 GHz line of ozone are good choices for spaceborne radiometer measurements because one front-end mixer assembly can be used to simultaneously observe both gases. The design of a sounding rocket based millimeter wave radiometer for measuring water vapor and ozone with a height resolution not possible by either ground based or limb sounding techniques is described.

Croskey, C. L.↗

Research in millimeter wave techniques

A model 180-GHz radiometer, employing a Cassegrain feed geometry with a parabolic main reflector and a subreflector fed by a corrugated conical horn, was constructed and tested. An absorber-coated chopper is used to modulate the signal, which is down-converted in a cross-guide harmonic mixer. A 100-GHz source was used to evaluate mixer performance and to optimize system parameters. Preliminary results indicate a noise figure of approximately 20 db is being achieved. Preliminary design studies and on-going research plans are discussed.

Dees, J. W.↗

High resolution millimeter-wave imaging sensor

A scanning 3-mm radiometer is described that has been built for use on a small aircraft to produce real time high resolution images of the ground when atmospheric conditions such as smoke, dust, and clouds make IR and visual sensors unusable. The sensor can be used for a variety of remote sensing applications such as measurements of snow cover and snow water equivalent, precipitation mapping, vegetation type and extent, surface moisture and temperature, and surface thermal inertia. The advantages of millimeter waves for cloud penetration and the ability to observe different physical phenomena make this system an attractive supplement to visible and IR remote sensing systems.

Wilson, W. J.↗

Radiometer Testbed Development for SWOT

Conventional altimeters include nadir looking colocated 18-37 GHz microwave radiometer to measure wet tropospheric path delay. These have reduced accuracy in coastal zone (within ~50 km from land) and do not provide wet path delay over land. The addition of high frequency channels to Jason-class radiometer will improve retrievals in coastal regions and enable retrievals over land. High-frequency window channels, 90, 130 and 166 GHz are optimum for improving performance in coastal region and channels on 183 GHz water vapor line are ideal for over-land retrievals.

internally calibrated radiometer↗

Applications of ground-based radiometric observations of millimeter wave radiation

A three-channel transportable radiometer that operates at 20.6, 31.65, and 90.0 GHz has been developed. The design of the radiometer is described and the results of various experimental applications of the radiometer are presented. The experiments include a comparison of brightness temperature measurements at various frequencies with the water vapor absorption models of Waters (1976) and Lieve (1989). Measurements of absorption ratios for cloud attenuation are given and the radiometer measurements are compared with oxygen absorption calculated using the Rasenkranz (1988) model.

Westwater, E. R.↗

Dual-Polarization, Multi-Frequency Antenna Array for use with Hurricane Imaging Radiometer

Advancements in common aperture antenna technology were employed to utilize its proprietary genetic algorithmbased modeling tools in an effort to develop, build, and test a dual-polarization array for Hurricane Imaging Radiometer (HIRAD) applications. Final program results demonstrate the ability to achieve a lightweight, thin, higher-gain aperture that covers the desired spectral band. NASA employs various passive microwave and millimeter-wave instruments, such as spectral radiometers, for a range of remote sensing applications, from measurements of the Earth's surface and atmosphere, to cosmic background emission. These instruments such as the HIRAD, SFMR (Stepped Frequency Microwave Radiometer), and LRR (Lightweight Rainfall Radiometer), provide unique data accumulation capabilities for observing sea surface wind, temperature, and rainfall, and significantly enhance the understanding and predictability of hurricane intensity. These microwave instruments require extremely efficient wideband or multiband antennas in order to conserve space on the airborne platform. In addition, the thickness and weight of the antenna arrays is of paramount importance in reducing platform drag, permitting greater time on station. Current sensors are often heavy, single- polarization, or limited in frequency coverage. The ideal wideband antenna will have reduced size, weight, and profile (a conformal construct) without sacrificing optimum performance. The technology applied to this new HIRAD array will allow NASA, NOAA, and other users to gather information related to hurricanes and other tropical storms more cost effectively without sacrificing sensor performance or the aircraft time on station. The results of the initial analysis and numerical design indicated strong potential for an antenna array that would satisfy all of the design requirements for a replacement HIRAD array. Multiple common aperture antenna methodologies were employed to achieve exceptional gain over the entire spectral frequency band while exhibiting superb VSWR (voltage standing wave ratio) values. Element size and spacing requirements were addressed for a direct replacement of the thicker, lower-performance, stack ed patch antenna array currently employed for the HIRAD application. Several variants to the multiband arrays were developed that exhibited four, equally spaced, high efficiency, "sweet spot" frequency bands, as well as the option for a high-performance wideband array. The 0.25-in. (≈6.4- mm) thickness of the antenna stack-up itself was achieved through the application of specialized antenna techniques and meta-materials to accomplish all design objectives.

Little, John↗

Prototype development of a Geostationary Synthetic Thinned Aperture Radiometer (GeoSTAR)

Weather prediction and hurricane tracking would greatly benefit of a continuous imaging capability of a hemisphere at millimeter wave frequencies. We are developing a synthetic thinned aperture radiometer (STAR) prototype operating from 50 to 56 GHz as a ground-based testbed to demonstrate the technologies needed to do full earth disk atmospheric temperature soundings from Geostationary orbit with very high spatial resolution. The prototype consists of a Y-array of 24 MMIC receivers that are compact units implemented with low noise InP MMIC LNAs, second harmonic I-Q mixers, low power IF amplifiers and include internal digital bias control with serial line communication to enable low cost testing and system integration. Furthermore, this prototype STAR includes independent LO and noise calibration signal phase switching circuitry for each arm of the Y-array to verify the operation and calibration of the system.

Millimeter wave low noise amplifiers↗

Waveform Modulation of Locked PIC Lasers for Microwave Photonic Radars

In a conventional radar or radiometer system, microwave or millimeter-wave signals are generated, distributed, and processed using electronic components that have considerable size, weight, and power (SWaP) and are typically limited in bandwidth and immunity to electromagnetic interference. Radar waveform modulation was achieved via phase and amplitude modulation of one of the two mixed laser signals enabling the use of highly developed photonic modulation technology.

Victor Torres↗

Millimeter-wave imaging sensor data evaluation

A passive 3-mm radiometer system with a mechanically scanned antenna was built for use on a small aircraft or an Unmanned Aerial Vehicle to produce real near-real-time, moderate-resolution (0.5) images of the ground. One of the main advantages of this passive imaging sensor is that it is able to provide surveillance information through dust, smoke, fog and clouds when visual and IR systems are unusable. It can also be used for a variety of remote sensing applications, such as measurements of surface moisture, surface temperature, vegetation extent and snow cover. It is also possible to detect reflective objects under vegetation cover.

Wilson, William J.↗

Millimeter-wave sensor image analysis

Images of an airborne, scanning, radiometer operating at a frequency of 98 GHz, have been analyzed. The mm-wave images were obtained in 1985/1986 using the JPL mm-wave imaging sensor. The goal of this study was to enhance the information content of these images and make their interpretation easier for human analysis. In this paper, a visual interpretative approach was used for information extraction from the images. This included application of nonlinear transform techniques for noise reduction and for color, contrast and edge enhancement. Results of the techniques on selected mm-wave images are presented.

Wilson, William J.↗