Search NASA⌕ Search

SEARCH · Search NASA

Results for “millimeter waves”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Basement rock hybrid drilling

A system for monitoring borehole parameters and switching to millimeter wave drilling based on the borehole parameters is provided. The system can include a mechanical drilling apparatus for forming a first portion of a borehole of a well. The first portion of the borehole can be formed based on a permeability of the first portion of the borehole and a temperature within the first portion of the borehole. The system can also include a millimeter wave drilling apparatus configured to inject millimeter wave radiation energy into a second portion of the borehole of the well via a waveguide. The second portion of the borehole can be formed via the millimeter wave drilling apparatus in response to determining the permeability of the first portion of the borehole is below a permeability threshold value and the temperature within the first portion of the borehole exceeds a temperature threshold value.

Araque, Carlos↗

Basement rock hybrid drilling

A system for monitoring and controlling downhole pressure of a well borehole relative to a lithostatic pressure of rock surrounding the borehole is provided. The system can include a millimeter wave drilling apparatus including a gyrotron configured to inject millimeter wave radiation energy into a borehole of a well via a waveguide configured for insertion into the borehole. The borehole can be formed via the millimeter wave drilling apparatus and having a downhole pressure monitored at a bottom of the well. The system can also include a compressor fluidically coupled to the borehole and configured to control the downhole pressure via a gas supplied into and/or received from the borehole. The compressor can be configured to control the downhole pressure relative to a lithostatic pressure determined for rock surrounding the well at the bottom of the well.

Araque, Carlos↗

In-process monitoring and prediction of droplet quality in droplet-on-demand liquid metal jetting additive manufacturing using machine learning

Abstract In droplet-on-demand liquid metal jetting (DoD-LMJ) additive manufacturing, complex physical interactions govern the droplet characteristics, such as size, velocity, and shape. These droplet characteristics, in turn, determine the functional quality of the printed parts. Hence, to ensure repeatable and reliable part quality it is necessary to monitor and control the droplet characteristics. Existing approaches for in-situ monitoring of droplet behavior in DoD-LMJ rely on high-speed imaging sensors. The resulting high volume of droplet images acquired is computationally demanding to analyze and hinders real-time control of the process. To overcome this challenge, the objective of this work is to use time series data acquired from an in-process millimeter-wave sensor for predicting the size, velocity, and shape characteristics of droplets in DoD-LMJ process. As opposed to high-speed imaging, this sensor produces data-efficient time series signatures that allows rapid, real-time process monitoring. We devise machine learning models that use the millimeter-wave sensor data to predict the droplet characteristics. Specifically, we developed multilayer perceptron-based non-linear autoregressive models to predict the size and velocity of droplets. Likewise, a supervised machine learning model was trained to classify the droplet shape using the frequency spectrum information contained in the millimeter-wave sensor signatures. High-speed imaging data served as ground truth for model training and validation. These models captured the droplet characteristics with a statistical fidelity exceeding 90%, and vastly outperformed conventional statistical modeling approaches. Thus, this work achieves a practically viable sensing approach for real-time quality monitoring of the DoD-LMJ process, in lieu of the existing data-intensive image-based techniques.

Gaikwad, Aniruddha (ORCID:0000000285642621)↗

Examination of Humidity and Ice Supersaturation Profiles Over West Antarctica Using Ground-Based G-Band Radiometer Retrievals

Humidity profiles retrieved from a ground-based millimeter-wave radiometer located at McMurdo Station, Antarctica and the West Antarctica Ice Sheet Divide are presented and their suitability to study the humidity of the polar climate is assessed. The dry conditions of the Antarctic winter and spring are ideal for ground-based millimeter-wave measurements and the retrievals appear to realistically reproduce the spatial and temporal variability of humidity at both sites. Furthermore, the radiometer has the ability to capture daily variability of very low humidity (0.5 to 4 g/kg) in the low-to-mid troposphere with an uncertainty of 10-20% during the Antarctic winter, spring, and summer. Despite the coarse vertical resolution (200-600 m in the first 4 km), the retrievals provide additional information with respect to the European Centre for Medium Range Weather Forecasts (ECMWF) profiles used as background information. The radiometer is also able to realistically identify the location and frequency of supersaturated layers with respect to ice in the mid troposphere. The occurrence of supersaturated layers is correlated with the occurrence of ice clouds identified by a cloud mask. Overall, results show that ground-based microwave and millimeter-wave radiometry is a viable complement to satellite observations to provide continuous information on the thermodynamic state of the low-to-mid troposphere at high latitudes.

54 ENVIRONMENTAL SCIENCES↗

GaN-based W-band receiver chip development for fusion plasma diagnostics

Millimeter-wave diagnostics have proven effective on various magnetic fusion devices worldwide, yet the formidable challenges posed by the harsh environments of future burning plasma devices, characterized by extreme temperatures, pressures, and radiation levels, remain a significant hurdle. To address these challenges, the utilization of wide bandgap Gallium Nitride (GaN)-based millimeter-wave diagnostics is a most promising solution for fusion reactor safety monitoring and control. A noteworthy W-band GaN-based system-on-chip receiver has been the demonstrated by employing HRL T3 40 nm GaN technology. This receiver chip, compactly designed with dimensions of 3 × 5 mm 2 , incorporates essential components such as the 75–110 GHz RF Low-Noise Amplifier (LNA), mixer, Intermediate Frequency (IF) amplifier, and Local Oscillator (LO) chain. This receiver chip will be packaged as a millimeter-wave receiver module and applied on the DIII-D National Fusion Facility, for fusion plasma edge shape monitoring for operational safety and dangerous disruption prediction. The laboratory measurement results have demonstrated suitable performance. Furthermore, this advancement is pivotal for accurate analysis of plasma behavior in the extreme conditions of burning plasma devices, driving progress in fusion research and technology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Infrared Galaxies Detected by the Atacama Cosmology Telescope

We report on 167 infrared (IR) galaxies selected by AKARI and IRAS and detected in the Atacama Cosmology Telescope (ACT) Data Release 5 (DR5) sky maps at the 98, 150, and 220 GHz frequency bands. Of these detections, 134 (80%) of the millimeter counterparts are first-time identifications with ACT. We expand the previous ACT extragalactic source catalogs, by including new 98 GHz detections and measurements from ACT DR5. We also report flux density measurements at the 98, 150, and 220 GHz frequency bands. We compute α 98-150 , α 98-220 , and α 150-220 millimeter-wave spectral indices and far-IR to millimeter-wave spectral indices between 90 μm and 98, 150, and 220 GHz. We specify the galaxy type, based on α 150-220 . We combine publicly available multiwavelength data—including ultraviolet, optical, near-IR, mid-IR, far-IR, and the millimeter measurements obtained in this work—and perform spectral energy distribution (SED) fitting with CIGALE. With the radio emission decomposition advantage of CIGALE V2022.0, we identify the origins of the millimeter emissions for 69 galaxies in our sample. Our analysis also shows that millimeter data alone indicates the need for a radio synchrotron component in the SEDs that are produced by active galactic nuclei (AGNs) and/or star formation. We present SEDs and measured physical properties of these galaxies, such as the dust luminosity, AGN luminosity, the total IR luminosity, and the ratio of the IR and radio luminosity. We quantify the relationships between the total IR luminosity and the millimeter-band luminosities, which can be used in the absence of SED analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Real-time steerable frequency-stepped Doppler backscattering (DBS) system for local helicon wave electric field measurements on the DIII-D tokamak

A new frequency-stepped Doppler backscattering (DBS) system has been integrated into a real-time steerable electron cyclotron heating launcher system to simultaneously probe local background turbulence (f < 10 MHz) and high-frequency (20–550 MHz) density fluctuations in the DIII-D tokamak. The launcher allows for 2D steering (horizontally and vertically) over wide angular ranges to optimize probe location and wavenumber response. The vertical steering can be optimized during a discharge in real time. The new DBS system employs a programmable frequency synthesizer with adjustable dwell time as a source to launch either O or X-mode polarized millimeter waves. This system can step in real-time over the entire E-band frequency range (60–90 GHz). This combination of capabilities allows for the diagnosis of the complex internal spatial structure of high power (>200 kW) helicon waves (476 MHz) injected from an external antenna during helicon current drive experiments in DIII-D. Broadband density fluctuations around the helicon frequency are observed during real-time scans of measurement location and wavenumber during these experiments. Analysis indicates that these broadband high-frequency fluctuations are a result of backscattering of the DBS millimeter-wave probe beam from plasma turbulence modulated by the helicon wave. It is observed that background turbulence is effectively locally “tagged” with the helicon wave electric field, forming images of the turbulent spectrum in the overall density fluctuation spectrum that appear as high-frequency sidebands of the turbulence. These observations of background turbulence and high-frequency fluctuations open up the possibility of monitoring local helicon wave amplitude by comparing the high-frequency signal amplitude to the simultaneously measured background turbulence. In combination with the real-time measurement location and wavenumber scanning capabilities (offered by real-time frequency-stepping and steering), this allows rapid determination of the spatial distribution of the helicon wave power during steady-state plasma operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

System-on-chip approach microwave imaging reflectometer on DIII-D tokamak

System-on-chip millimeter wave integrated circuit technology is used on the two-dimensional millimeter-wave imaging reflectometer (MIR) upgrade for density fluctuation imaging on the DIII-D tokamak fusion plasma. Customized CMOS chips have been successfully developed for the transmitter module and receiver module array, covering the 55–75 GHz working band. The transmitter module has the capability of simultaneously launching eight tunable probe frequencies (>0 dBm output power each). The receiver enclosure contains 12 receiver modules in two vertical lines. The quasi-optical local oscillator coupling of previous MIR systems has been replaced with an internal active frequency multiplier chain for improved local oscillator power delivery and flexible installation in a narrow space together with improved shielding against electromagnetic interference. The 55–75 GHz low noise amplifier, used between the receiver antenna and the first-stage mixer, significantly improves module sensitivity and suppresses electronics noise. The receiver module has a 20 dB gain improvement compared with the mini-lens approach and better than –75 dBm sensitivity, and its electronics noise temperature has been reduced from 55 000 K down to 11 200 K. Further, the V-band MIR system is developed for co-located multi-field investigation of MHD-scale fluctuations in the pedestal region with W-band electron cyclotron emission imaging on DIII-D tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of a 43 GHz microplasma within a photonic crystal

The electron density (n e ) and argon metastable density (1 s 5 ) of a 43GHz microplasma are obtained using the zero-dimensional plasma kinetics solver (ZDPlasKin®) for an incident power of 160 and 1000mW and argon pressures of 10–600Torr (1.3 ×10 3 to 8.0 × 10 4 Pa). These simulations are compared with previously published experimental data. To determine the self-consistent electric field in the modeled plasma, the three-dimensional millimeter wave fields are computed as a function of electron density using ANSYS EM19.2, HFSS®. This electromagnetic field model is coupled to ZDPlasKin such that any increase in the simulated plasma density correctly attenuates the simulated electric field within the microplasma. The electron density is found to be sensitive to argon gas temperature, so a two-zone temperature model was needed to obtain agreement with experimental measurements. The temperature in the central core of the microplasma was determined by a previous experimental study. That temperature was used as an input to the model for the simulation of volume recombination losses. The outer regions of the microplasma are assumed to be in equilibrium with the walls (300K). This second temperature was used in the model to determine diffusion losses. The modeled electron and metastable densities are of the order 10 20 and 10 18 m –3 , respectively. This is in good agreement with those measured experimentally as long as the two-zone temperature model is used. In the absence of a hot gas core, the modeled three-body recombination rates are excessive and the simulation severely under-predicts the electron density and over-estimates the metastable density. We conclude that the millimeter wave microplasma has a hot core (2500K at 600 Torr) that rarifies the argon gas and effectively reduces three-body recombination. Furthermore, this allows one to achieve high electron density on the order of 10 20 m –3 with only 100mW of wave power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultra-broadband voltage-controlled oscillator linearization for frequency modulated continuous wave MMW imaging systems

Millimeter-wave (MMW) imaging systems require high resolution and spurious free dynamic range (SFDR) to produce images with low artifacts. In these systems, lateral resolution is determined by the center frequency and the ratio of the aperture size to the distance to the target. The downrange resolution is determined by the system bandwidth; for very fine downrange resolution of a target, or material layers/discontinuities, the bandwidth must be very broad. Additionally, the response over the bandwidth must be measured very rapidly to support high speed acquisition over large apertures. A voltage-controlled oscillator (VCO) is a standard means of generating the ultra-broadband frequency chirp. This paper investigates the use of a broadband VCO for use in MMW imaging systems, a linear-phase calibration technique, and digital-to-analog converter (DAC) parameter considerations for controlling the VCO.

FMCW, homodyne, VCO, DAC, difference frequency, SF↗

Exploration of the polarization angle variability of the Crab Nebula with POLARBEAR and its application to the search for axionlike particles

The Crab Nebula, also known as Tau A, is a polarized astronomical source at millimeter wavelengths. It has been used as a stable light source for polarization angle calibration in millimeter-wave astronomy. However, it is known that its intensity and polarization vary as a function of time at a variety of wavelengths. Thus, it is of interest to verify the stability of the millimeter-wave polarization. If detected, polarization variability may be used to better understand the dynamics of Tau A, and for understanding the validity of Tau A as a calibrator. One intriguing application of such observation is to use it for the search of axionlike particles (ALPs). Ultralight ALPs couple to photons through a Chern-Simons term, and induce a temporal oscillation in the polarization angle of linearly polarized sources. After assessing a number of systematic errors and testing for internal consistency, we evaluate the variability of the polarization angle of the Crab Nebula using 2015 and 2016 observations with the 150 GHz P instrument. We place a median 95% upper bound of polarization oscillation amplitude A < 0.06 5 ° over the oscillation frequencies from 0.75 year − 1 to 0.66 hour − 1 . Assuming that no sources other than ALP are causing Tau A’s polarization angle variation, that the ALP constitutes all the dark matter, and that the ALP field is a stochastic Gaussian field, this bound translates into a median 95% upper bound of ALP-photon coupling g a γ γ < 2.16 × 10 − 12 GeV − 1 × ( m a / 10 − 21 eV ) in the mass range from 9.9 × 10 − 23 eV to 7.7 × 10 − 19 eV . This demonstrates that this type of analysis using bright polarized sources is as competitive as those using the polarization of cosmic microwave background in constraining ALPs. Published by the American Physical Society 2024

Adachi, Shunsuke (ORCID:0000000204007555)↗

Quasiparticle Poisoning of Superconducting Qubits from Resonant Absorption of Pair-Breaking Photons

The ideal superconductor provides a pristine environment for the delicate states of a quantum computer: because there is an energy gap to excitations, there are no spurious modes with which the qubits can interact, causing irreversible decay of the quantum state. As a practical matter, however, there exists a high density of excitations out of the superconducting ground state even at ultralow temperature; these are known as quasiparticles. Observed quasiparticle densities are of order 1 μ m - 3 , tens of orders of magnitude greater than the equilibrium density expected from theory. Nonequilibrium quasiparticles extract energy from the qubit mode and can induce dephasing. Here we show that a dominant mechanism for quasiparticle poisoning is direct absorption of high-energy photons at the qubit junction. We use a Josephson junction-based photon source to controllably dose qubit circuits with millimeter-wave radiation, and we use an interferometric quantum gate sequence to reconstruct the charge parity of the qubit. We find that the structure of the qubit itself acts as a resonant antenna for millimeter-wave radiation, providing an efficient path for photons to generate quasiparticles. A deep understanding of this physics will pave the way to realization of next-generation superconducting qubits that are robust against quasiparticle poisoning.

Liu, Chuan-Hong↗

Detection of Millimeter-wavelength Flares from Two Accreting White Dwarf Systems in the SPT-3G Galactic Plane Survey

Blind discoveries of millimeter-wave transient events in nontargeted surveys, as opposed to follow-up or pointed observations, have only become possible in the past decade using cosmic microwave background surveys. Here we present the first results from the SPT-3G Galactic Plane Survey—the first dedicated high-sensitivity, wide-field, time-domain, millimeter-wave survey of the Galactic Plane, conducted with the South Pole Telescope (SPT) using the SPT-3G camera. The survey field covers approximately 100 deg 2 near the Galactic center. In 2023 and 2024, this survey consisted of roughly 1500 individual 20 minute observations in three bands centered at 95, 150, and 220 GHz, with plans for more observations in the coming years. We report the detection of two transient events exceeding a 5σ threshold in both the 95 and 150 GHz bands in the first 2 yr of SPT-3G Galactic Plane Survey data. Both events are unpolarized and exhibit durations of approximately 1 day, with peak flux densities at 150 GHz of at least 50 mJy. The peak isotropic luminosities at 150 GHz are on the order of 10 31 erg s −1 . Both events are associated with previously identified accreting white dwarfs. Magnetic reconnection in the accretion disk is a likely explanation for the observed millimeter flares. In the future, we plan to expand the transient search in the Galactic Plane by lowering the detection threshold, enabling single-band detections, analyzing lightcurves on a range of timescales, and including additional data from future observations.

Wan, Y. [Univ. of Illinois at Urbana-Champaign, IL↗

System-on-chip integrated circuit technology applications on the DIII-D tokamak for multi-field measurements

Several mm-wave diagnostics on the DIII-D tokamak provide multi-scale and multi-dimensional measurements of plasma profile evolution and turbulence fluctuations. Mm-wave fusion plasma diagnostics that adopt system-on-chip integrated circuit technology can provide better space utilization, flexible installation, and improved sensitivity. In order to further extend this technology for additional fusion facilities with a higher toroidal magnetic field, V-band (55–75 GHz) and F-band (90–140 GHz) chips for Microwave Imaging Reflectometer (MIR) and Electron Cyclotron Emission Imaging (ECEI) instruments are developed and tested in the Davis Millimeter Wave Research Center (DMRC). Current measurement data show that correlation between these SoC-based diagnostic instruments with other state-of-the-art diagnostics enables co-located multi-field turbulence fluctuation measurement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel Concepts for High Gradient Acceleration (Final Technical Report)

We have conducted an intensive, pioneering program to demonstrate novel concepts for achieving high gradient acceleration at frequencies from the conventional microwave bands up to the millimeter wave /THz bands. High gradient accelerators hold the promise of smaller and less costly accelerators for applications ranging from the largest scale accelerators used for discovery science down to the smallest accelerators used for industrial, homeland security and medical applications. The research consisted of two major research thrusts: 1.) Structure-based wakefield accelerator (SWFA) research in collaboration with the Argonne Wakefield Accelerator research group and 2.) Millimeter Wave / THz high gradient acceleration in collaboration with SLAC. The specific goals of the research program were: Design novel metallic metamaterial structures that increase the beam-wave coupling for the accelerator mode and reduce the effect of high order modes; test novel metamaterial structures to achieve higher output power, > 1 GW at X-Band (11.7 GHz), in test at the Argonne Wakefield Accelerator (AWA); determine the experimental breakdown threshold for nanosecond-scale pulses at X-Band in testing at the AWA; test a 110 GHz accelerator structure with a field emission electron gun, built at SLAC, using pulses from a 1 MW, 110 GHz gyrotron; design, build and test a 110 GHz quasi-optical, resonant-ring pulse compressor to compress microsecond pulses from the 1 MW gyrotron into > 20 MW, 5 ns output pulses for accelerator structure testing. The proposed research program built on our successes in our research program including: Generation of 510 MW, 2.1 ns (FWHM) pulses at 11.7 GHz from a metallic metamaterial structure in test at the Argonne Wakefield Accelerator using a train of eight 65 MeV electron bunches spaced at 1.3 GHz with a total charge of 280 nC. The metamaterial structure consisted of 100 copper unit cells each consisting of a “wagon-wheel” plate and a spacer plate with a total structure length of 0.2 m. The 510 MW pulse generated an on-axis wakefield of 130 MV/m that could be used to accelerate a trailing witness bunch. Demonstration of coupling of an unprecedented rf power level of 575kW into a 110 GHz accelerator structure using a quasi-optical setup. The standing structure consisted of a central copper cavity located between two matching cavities fed by a TM01 mode. The 6 ns input pulses were sliced from 3 microsecond pulses from the gyrotron using a laser-driven silicon switch. We obtained an unprecedented high gradient up to 230MV/m corresponding to a peak surface electric field of more than 520 MV/m.

43 PARTICLE ACCELERATORS↗

Development and preliminary results of 270 GHz microwave forward scattering diagnostic system on the experimental advanced superconducting tokamak (EAST)

To measure localized (intermediate, high) poloidal wavenumber electron density fluctuations, a tangential millimeter-wave collective scattering system has been designed and successfully developed on the experimental advanced superconducting tokamak (EAST). This innovative system employs a 270 GHz mm-wave probe beam, emitted from the mid-plane of Port K and directed towards Port P after passing through a combination of two in-vessel mirrors. Here these two ports are located on the EAST device’s midplane and are 110° apart. The downward scattered signals pass through two in-vessel mirrors, and exit through the P window. The received multi-channel separated scattering signals are arranged along the poloidal direction. This optical arrangement makes the monitored turbulent wave number is poloidal dominant and up to 40 cm −1 . The tangential microwave scattering scheme enables this diagnostic to monitor local density fluctuations, with typically a radial spatial resolution △ R = 5 cm, and a wavenumber resolution of △ k = 0.4 cm −1 . The scattering system underwent comprehensive laboratory testing in 2023, with installation finalized in 2024. The system features steerable launch and receiver optics, allowing remote control to position the scattering volume from normalized radius ρ –0 to the pedestal region on a shot-by-shot basis. Effective experimental data, characterized by distinct off-center spectral peaks, have been successfully obtained in neutral beam-heated plasmas on EAST. The beam tracing forward modeling has been employed for experimental data interpretation. The advanced millimeter-wave scattering system provides fluctuation measurement capability from ion temperature gradient to electron temperature gradient scale on low field side. Preliminary experimental density fluctuation data have been successfully obtained in neutral beam-heated plasmas on EAST. The localized measurement will be used for kinetic turbulence transport numerical simulation validation.

high-k collective scattering↗