Genomic data detect corresponding signatures of population size change on an ecological time scale in two salamander species
Not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Selective laser sintering methods are workhorses for additively manufacturing polymer-based components. The ease of rapid prototyping also means it is easy to produce illicit components. It is necessary to have a data-calibrated in-situ physical model of the build process in order to predict expected and defective microstructure characteristics that inform component provenance. Toward this end, sintering models are calibrated and characteristics such as component defects are explored. This is accomplished by assimilating multiple data streams, imaging analysis, and computational model predictions in an adaptive Bayesian parameter estimation algorithm. From these data sources, along with a phase-field model, bulk porosity distributions are inferred. Model parameters are constrained to physically-relevant search directions by sensitivity analysis, and then matched to predictions using adaptive sampling. Using this feedback loop, data-constrained estimates of sintering model parameters along with uncertainty bounds are obtained.
Here, we describe a method for training a neural network (NN) to approximate the full model Bayesian inference of plasma profiles from x-ray imaging diagnostic measurements. The modeling is carried out within the Minerva Bayesian modeling framework where models are defined as a set of assumptions, prior beliefs on parameter values and physics knowledge. The goal is to use NNs for fast ion and electron temperature profile inversion from measured image data. The NN is trained solely on artificial data generated by sampling from the joint distribution of the free parameters and model predictions. The training is carried out in such a way that the mapping learned by the network constitutes an approximation of the full model Bayesian inference. The analysis is carried out on images constituted of 20 × 195 pixels corresponding to binned lines of sight and spectral channels, respectively. Through the full model inference, it is possible to infer electron and ion temperature profiles as well as impurity density profiles. When the network is utilized for the inference of the temperature profiles, the analysis time can be reduced down to a few tens of microseconds for a single time point, which is a drastic improvement if compared to the ≈4 h long Bayesian inference. The procedure developed for the generation of the training set does not rely on diagnostic-specific features, and therefore it is in principle applicable to any other model developed within the Minerva framework. The trained NN has been tested on data collected during the first operational campaign at W7-X, and compared to the full model Bayesian inference results.
AIF for Vis contains the Active Inference models and analysis scripts used to study a simple visualization-interpretation task: estimating the average value of two bars in a bar chart. The work is a proof of concept for translating hypothesized cognitive strategies into executable, inspectable process models. We implement two idealized strategies inspired by dual-process accounts of visualization-aided decision making: *Fast model: a compressed, heuristic strategy that estimates the visual midpoint of the two bars and maintains a single belief over their average. *Slow model: a sequential, analytic strategy that estimates the two bar heights separately and maintains them in working memory before computing an average. Both models use a common Active-Inference-inspired framework for sequential perception, belief updating, action selection, and reporting. Their different internal representations produce distinct predicted vulnerabilities: *the Fast model is more susceptible to tick-salience bias; *the Slow model is more susceptible to working-memory decay. The repository includes the model implementations, scripts used for the experiments reported in the paper, precomputed trial-level results, and plotting scripts.
Ultrasound imaging is a critical tool for triaging and diagnosing subjects but only if images can be properly interpreted. Unfortunately, in remote or military medicine situations, the expertise to interpret images can be lacking. Machine-learning image interpretation models that are explainable to the end user and deployable in real time with ultrasound equipment have the potential to solve this problem. We have previously shown how a YOLOv3 (You Only Look Once) object detection algorithm can be used for tracking shrapnel, artery, vein, and nerve fiber bundle features in a tissue phantom. However, real-time implementation of an object detection model requires optimizing model inference time. Here, we compare the performance of five different object detection deep-learning models with varying architectures and trainable parameters to determine which model is most suitable for this shrapnel-tracking ultrasound image application. We used a dataset of more than 16,000 ultrasound images from gelatin tissue phantoms containing artery, vein, nerve fiber, and shrapnel features for training and evaluating each model. Every object detection model surpassed 0.85 mean average precision except for the detection transformer model. Overall, the YOLOv7tiny model had the higher mean average precision and quickest inference time, making it the obvious model choice for this ultrasound imaging application. Other object detection models were overfitting the data as was determined by lower testing performance compared with higher training performance. In summary, the YOLOv7tiny object detection model had the best mean average precision and inference time and was selected as optimal for this application. Next steps will implement this object detection algorithm for real-time applications, an important next step in translating AI models for emergency and military medicine.
Groundwater model structural error is ubiquitous, due to simplification and/or misrepresentation of real aquifer systems. During model calibration, the basic hydrogeological parameters may be adjusted to compensate for structural error. This may result in biased predictions when such calibrated models are used to forecast aquifer responses to new forcing. Here, we investigate the impact of model structural error on calibration and prediction of a real-world groundwater flow model, using a Bayesian method with a data-driven error model to explicitly account for model structural error. The error-explicit Bayesian method jointly infers model parameters and structural error and thereby reduces parameter compensation. In this study, Bayesian inference is facilitated using high performance computing and fast surrogate models (based on machine learning techniques) as a substitute for the computationally expensive groundwater model. We demonstrate that with explicit treatment of model structural error, the Bayesian method yields parameter posterior distributions that are substantially different from those derived using classical Bayesian calibration that does not account for model structural error. We also found that the error-explicit Bayesian method gives signficantly more accurate prediction along with reasonable credible intervals. Finally, through variance decomposition, we provide a comprehensive assessment of prediction uncertainty contributed from parameter, model structure, and measurement uncertainty. The results suggest that the error-explicit Bayesian approach provides a solution to real-world modeling applications for which data support the presence of model structural error, yet model deficiency cannot be specifically identified or corrected.
Failure times of software undergoing random debugging can be modeled as order statistics of independent but nonidentically distributed exponential random variables. Using this model inferences can be made about current reliability and, if debugging continues, future reliability. This model also shows the difficulty inherent in statistical verification of very highly reliable software such as that used by digital avionics in commercial aircraft.
Failure times of software undergoing random debugging can be modelled as order statistics of independent but nonidentically distributed exponential random variables. Using this model inferences can be made about current reliability and, if debugging continues, future reliability. This model also shows the difficulty inherent in statistical verification of very highly reliable software such as that used by digital avionics in commercial aircraft.
The scientific community faces important discussions on the validity of the linear no-threshold (LNT) model for radiation-associated cardiovascular diseases at low and moderate doses. In the present study, mortalities from cerebrovascular diseases (CeVD) and heart diseases from the latest data on atomic bomb survivors were analyzed. The analysis was performed with several radio-biologically motivated linear and nonlinear dose–response models. For each detrimental health outcome one set of models was identified that all fitted the data about equally well. This set was used for multi-model inference (MMI), a statistical method of superposing different models to allow risk estimates to be based on several plausible dose–response models rather than just relying on a single model of choice. MMI provides a more accurate determination of the dose response and a more comprehensive characterization of uncertainties. It was found that for CeVD, the dose–response curve from MMI is located below the linear no-threshold model at low and medium doses (0–1.4 Gy). At higher doses MMI predicts a higher risk compared to the LNT model. A sublinear dose–response was also found for heart diseases (0–3 Gy). The analyses provide no conclusive answer to the question whether there is a radiation risk below 0.75 Gy for CeVD and 2.6 Gy for heart diseases. MMI suggests that the dose–response curves for CeVD and heart diseases in the Lifespan Study are sublinear at low and moderate doses. This has relevance for radiotherapy treatment planning and for international radiation protection practices in general.
The spatial variation of physical quantities, such as the mass density, across solar atmospheric waveguides governs the timescales and spatial scales for wave damping and energy dissipation. The direct measurement of the spatial distribution of density, however, is difficult, and indirect seismology inversion methods have been suggested as an alternative. We applied Bayesian inference, model comparison, and model-averaging techniques to the inference of the cross-field density structuring in solar magnetic waveguides using information on periods and damping times for resonantly damped magnetohydrodynamic transverse kink oscillations. Three commonly employed alternative profiles were used to model the variation of the mass density across the waveguide boundary. Parameter inference enabled us to obtain information on physical quantities such as the Alfvén travel time, the density contrast, and the transverse inhomogeneity length scale. The inference results from alternative density models were compared and their differences quantified. Then, the relative plausibility of the considered models was assessed by performing model comparison. Our results indicate that the evidence in favor of any of the three models is minimal, unless the oscillations are strongly damped. In such a circumstance, the application of model-averaging techniques enables the computation of an evidence-weighted inference that takes into account the plausibility of each model in the calculation of a combined inversion for the unknown physical parameters.
A Bayesian computational framework for parsimonious inference in stochastic nonlinear dynamical systems is presented. This framework enables the concurrent estimation of system states, time-varying parameters, time-invariant parameters, and the optimal sparsity structure of the model parameters. Because differential equation-based models are often simplified mechanistic or phenomenological representations, robust inference from noisy measurement data requires explicit treatment of model error and uncertainty. Model error and time-varying parameters can be represented as random processes, enabling inference while making minimal assumptions about the underlying sources of discrepancy and variability. Adopting stochastic differential equation representations affords the model significant flexibility, but can also render it susceptible to overfitting during statistical inversion, where the inferred model may track noise rather than the underlying signal. To alleviate the effects of overfitting and to enable the discovery of the optimal sparse representation of the time-invariant parameters, a Bayesian sparse learning algorithm is embedded within the framework. This sparse learning framework adopts an approximate hierarchical Bayesian setting defined by a series of semi-analytical expressions. The model structure inference framework is validated using a stochastic compartmental model for tracking and forecasting active cases of an infectious disease. Compartmental models describe population-level infectious disease dynamics through interactions among population fractions grouped by disease state. Mathematically, such models consist of a system of coupled ordinary differential equations. This example adopts an expressive compartmental model that includes multiple possible interactions between disease states, motivated by early uncertainty surrounding COVID-19 reinfection dynamics and their implications for long-term epidemic forecasting. The sparse learning exercise permits the inference of a priori unknown epidemiological dynamics from simulated public health data, discovering the nested compartmental model that optimizes the trade-off between average data-fit and model complexity. It is shown that inducing sparsity among the model parameters eliminates redundant interactions between compartments, equivalently revealing the optimal coupling structure between differential equations.
Conformational changes drive protein function, including catalysis, allostery, and signaling. X-ray diffuse scattering from protein crystals has frequently been cited as a probe of these correlated motions, with significant potential to advance our understanding of biological dynamics. However, recent work challenged this prevailing view, suggesting instead that diffuse scattering primarily originates from rigid body motions and could therefore be applied to improve structure determination. To investigate the nature of the disorder giving rise to diffuse scattering, and thus the potential applications of this signal, a diverse repertoire of disorder models was assessed for its ability to reproduce the diffuse signal reconstructed from three protein crystals. This comparison revealed that multiple models of intramolecular conformational dynamics, including ensemble models inferred from the Bragg data, could not explain the signal. Models of rigid body or short-range liquid-like motions, in which dynamics are confined to the biological unit, showed modest agreement with the diffuse maps, but were unable to reproduce experimental features indicative of long-range correlations. Extending a model of liquid-like motions to include disorder across neighboring proteins in the crystal significantly improved agreement with all three systems and highlighted the contribution of intermolecular correlations to the observed signal. These findings anticipate a need to account for intermolecular disorder in order to advance the interpretation of diffuse scattering to either extract biological motions or aid structural inference.
The Event Horizon Telescope (EHT) is a millimeter-wavelength, very-long-baseline interferometry (VLBI) experiment that is capable of observing black holes with horizon-scale resolution. Early observations have revealed variable horizon-scale emission in the Galactic Center black hole, Sagittarius A* (Sgr A*). Comparing such observations to time-dependent general relativistic magnetohydrodynamic (GRMHD) simulations requires statistical tools that explicitly consider the variability in both the data and the models. We develop here a Bayesian method to compare time-resolved simulation images to variable VLBI data, in order to infer model parameters and perform model comparisons. We use mock EHT data based on GRMHD simulations to explore the robustness of this Bayesian method and contrast it to approaches that do not consider the effects of variability. We find that time-independent models lead to offset values of the inferred parameters with artificially reduced uncertainties. Moreover, neglecting the variability in the data and the models often leads to erroneous model selections. We finally apply our method to the early EHT data on Sgr A*.
To assess the reliability of critical technologies like nuclear plants and infrastructure systems and improve the robustness of design, engineers have to quantify the uncertainties surrounding the system behavior accurately. However, the complexity of the problem can make standard reliability analysis algorithms prohibitively expensive, primarily due to the high computational cost of estimating the system response at each iteration. This cost can be greatly reduced by using multi-fidelity modeling and machine learning to build a surrogate model to replace the expensive response function. We propose a general and robust method for building surrogates from multiple Low Fidelity (LF) models coupled with machine learning to retain accuracy. Our framework first constructs “Corrected Low Fidelity models” (CLFs) by coupling a High Fidelity (HF) model inferred Gaussian Process correction term with each of the LF models. It then uses the correction terms to assign model probabilities to each of these CLFs in an explainable way before using them to assemble the final surrogate. No assumptions are made about the type of the LF models or their correlation with the HF model. The proposed surrogate modeling framework is used within the subset simulation algorithm (a variance-reduced MCMC-based reliability analysis algorithm) for enhanced efficiency. Additionally, an active learning step is added to the algorithm to adaptively decide when the surrogate is not sufficiently accurate, at which point the HF model is called and used to refine the surrogate. Through a frame buckling example, our method is shown to be highly efficient at reducing the expensive HF model calls while accurately estimating the failure probability.
To plan and optimize energy storage demands that account for Li-ion battery aging dynamics, techniques need to be developed to diagnose battery internal states accurately and rapidly. Here, this study seeks to reduce the computational resources needed to determine a battery's internal states by replacing physics-based Li-ion battery models - such as the single-particle model (SPM) and the pseudo-2D (P2D) model - with a physics-informed neural network (PINN) surrogate. The surrogate model makes high-throughput techniques, such as Bayesian calibration, tractable to determine battery internal parameters from voltage responses. This manuscript is the first of a two-part series that introduces PINN surrogates of Li-ion battery models for parameter inference (i.e., state-of-health diagnostics). In this first part, a method is presented for constructing a PINN surrogate of the SPM. A multi-fidelity hierarchical training, where several neural nets are trained with multiple physics-loss fidelities is shown to significantly improve the surrogate accuracy when only training on the governing equation residuals. The implementation is made available in a companion repository (https://github.com/NREL/PINNSTRIPES). The techniques used to develop a PINN surrogate of the SPM are extended in Part II for the PINN surrogate for the P2D battery model, and explore the Bayesian calibration capabilities of both surrogates.
This dataset contains the structural models for the primary transcripts of the Rhodospirillum rubrum proteome as well as sequence alignment results for a subset of the encoded proteins. For each protein, the five models inferred from AlphaFold 2 are provided. The largest pTM-scoring model for each protein was energy minimized; this minimized structure as well as its AlphaFold pickle output file are also provided. This set of structures represent an alternate source of models for the R. rubrum proteome to those available in the AlphaFold Protein Structure Database. For proteins that have been annotated as hypothetical, sequence alignment results from the HHblits and SAdLSA alignment methods are provided. These methods are often more capable to resolve sequence homology than other methods. Therefore, the results from both HHblits and SAdLSA are provided to identify possible homologs for these challenging proteins. Numerous sequence databases are utilized for these alignments. References AlphaFold v2 Multimer: https://doi.org/10.1101/2021.10.04.463034. References HHBlits: https://doi.org/10.1186/s12859-019-3019-7. References SAdLSA: https://doi.org/10.3389/fbinf.2021.689960.
This dataset contains the structural models for the primary transcripts of the Desulfovibrio vulgaris proteome as well as sequence alignment results for a subset of the encoded proteins. For each protein, the five models inferred from AlphaFold 2 are provided. The largest pTM-scoring model for each protein was energy minimized; this minimized structure as well as its AlphaFold pickle output file are also provided. This set of structures represent an alternate source of models for the D. vulgaris proteome to those available in the AlphaFold Protein Structure Database (AFDB). This is a bit more complicated since the proteins reporting in the AFDB originate from an outdated form of the D. vulgaris sequence. The different versions of the D. vulgaris gene annotation are collected in the Chronology subdirectory; further consideration of these changes on the structural space of the proteome are currently underway. For proteins that have been annotated as hypothetical, sequence alignment results from the HHblits and SAdLSA alignment methods are provided. These methods are often more capable to resolve sequence homology than other methods. Therefore, the results from both HHblits and SAdLSA are provided to identify possible homologs for these challenging proteins. Numerous sequence databases are utilized for these alignments. References AlphaFold v2 Multimer: https://doi.org/10.1101/2021.10.04.463034. References HHblits: hhtps://doi.org/10.1186/s12859-019-3019-7. References SAdLSA: hhtps://doi.org/10.3389/fbinf.2021.689960.
This dataset contains the structural models for the primary transcripts of the Rhodopseudomonas palustris proteome. For each protein, the five models inferred from AlphaFold 2 are provided. The largest pTM-scoring model for each protein was energy minimized; this minimized structure as well as its AlphaFold pickle output file are also provided. This set of structures represent an alternate source of models for the R. palustris proteome to those available in the AlphaFold Protein Structure Database.