Search NASA⌕ Search

SEARCH · Search NASA

Results for “module cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A Digital Twin Framework for Liquid-cooled Supercomputers as Demonstrated at Exascale

We present ExaDigiT, an open-source framework for developing comprehensive digital twins of liquid-cooled supercomputers. It integrates three main modules: (1) a resource allocator and power simulator, (2) a transient thermo-fluidic cooling model, and (3) an augmented reality model of the supercomputer and central energy plant. The framework enables the study of "what-if" scenarios, system optimizations, and virtual prototyping of future systems. Using Frontier as a case study, we demonstrate the framework's capabilities by replaying six months of system telemetry for systematic verification and validation. Such a comprehensive analysis of a liquid-cooled exascale supercomputer is the first of its kind. ExaDigiT elucidates complex transient cooling system dynamics, runs synthetic or real workloads, and predicts energy losses due to rectification and voltage conversion. Throughout our paper, we present lessons learned to benefit HPC practitioners developing similar digital twins. We envision the digital twin will be a key enabler for sustainable, energy-efficient supercomputing.

Brewer, Wes↗

A Modified DBC Substrate Improving Thermal Performance for Confined Space Applications

High-power modules use substrates to house the semiconductor device and for electrical insulation. These substrates are constructed with thermally conductive dielectric material sandwiched between two metals to extract heat from semiconductor chips. Thus, the required cooling performance of a power module is linked to the substrate’s thermal performance and can vary based on the substrate technologies. Here, in this study, five substrate technologies were evaluated for space-restricted applications: direct-bonded copper (DBC), an insulated metal substrate (IMS), a thermally annealed pyrolytic graphite (TPG)-based IMS, DBC-based double-sided cooling, and direct-bonded aluminum (DBA) where the heat sink is directly attached without thermal interface materials (TIMs). The finite element (FE) analysis results suggest that the popular DBC substrate has thermal performance better than that of the other substrates for space-constrained applications. To further improve the thermal performance, a modified DBC substrate was proposed where a copper block was added between the semiconductor and the DBC substrate to achieve heat spreading underneath the chip. The modified DBC performance was then compared with the aforementioned substrates and the results showed significant thermal performance improvement. The results were verified with experimental results where the proposed substrate showed 20% more loss handling capability compared to an identical DBC substrate.

42 ENGINEERING↗

Multiscale Thermal-hydraulic analysis of the MARVEL micro-reactor using coupled MOOSE Subchannel (SCM) and SAM

MARVEL is a natural-convection-cooled sodium-potassium microreactor that is anticipated to generate 85 kilowatts of thermal energy. It will operate within Idaho National Laboratory’s Transient Reactor Test Facility and is being developed by the DOE Microreactor Program. MARVEL will be used to test microreactor applications, evaluate systems for remote monitoring, and develop autonomous control technologies. A thermal-hydraulic computational model of this facility is a valuable tool to study important transients and calculate the safety limits of the micro-reactor design. For this purpose, the authors have chosen to use a multiscale coupled simulation: SCM for modeling the reactor core and SAM for the reactor’s primary cooling system. SCM is MOOSE physics module for subchannel analysis, which was designed to model single-phase flows through liquid-metal cooled, wire-wrapped fuel pin sub-assemblies, ordered in a triangular lattice. The SCM code was modified to be able to model MARVEL’s unique geometry. SAM is a systems analysis module based on the MOOSE framework. It aims to provide fast-running, whole-plant transient analyses capability with improved-fidelity for various advanced reactor types. The coupling between the two SCM and SAM for MARVEL modeling is done implementing a domain over-lapping approach. The resulting coupled simulation can model transients such as reactor startup/shutdown and provide an intermediate fidelity picture of the temperature field and other variables, in the core. Results for the steady-state simulations are presented in the article as well as flow blockage transient.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Multiscale Thermal-hydraulic analysis of the MARVEL microreactor using a coupled SAM and SCM simulation. (PPTX)

This is .pptx document presenting a summary of the paper of the same name that has been submitted and accepted to NURETH-21: MARVEL is a natural-convection-cooled sodium-potassium microreactor that is anticipated to generate 85 kilowatts of thermal energy. It will operate within Idaho National Laboratory Transient Reactor Test Facility and is being developed by the DOE Microreactor Program. MARVEL will be used to test microreactor applications, evaluate systems for remote monitoring, and develop autonomous control technologies. A thermal-hydraulic computational model of this facility is a valuable tool to study important transients and calculate the safety limits of the micro-reactor design. For this purpose, the authors have chosen to use a multiscale coupled simulation: SCM for modeling the reactor core and SAM for the reactor's primary cooling system. SCM is MOOSE physics module for subchannel analysis, which was designed to model single-phase flows through liquid-metal cooled, wire-wrapped fuel pin sub-assemblies, ordered in a triangular lattice. The SCM code was modified to be able to model MARVEL?s unique geometry. SAM is a systems analysis module based on the MOOSE framework. It aims to provide fast-running, whole-plant transient analyses capability with improved-fidelity for various advanced reactor types. The coupling between the two SCM and SAM for MARVEL modeling is done implementing a domain over-lapping approach. The resulting coupled simulation can model transients such as reactor startup/shutdown and provide an intermediate fidelity picture of the temperature field and other variables, in the core. Results for the steady-state simulations are presented in the article as well as flow blockage transient.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Power Electronic Substrates for Space Restricted Application

High-power modules use substrates to house the semiconductor device and for electrical insulation. These substrates are constructed with thermally conductive dielectric material sandwiched between two metals to extract heat from semiconductor chips. Thus, the required cooling performance of a power module is linked to the substrate’s thermal performance and can vary based on the substrate technologies. In this study, four substrate technologies were evaluated for space-restricted applications: direct-bonded copper, an insulated metal substrate, a thermally annealed pyrolytic graphite–based insulated metal substrate, and direct-bonded aluminum, where the heat sink is directly attached without thermal interface materials. The finite element results suggest that the popular direct-bonded copper substrate has better thermal performance than the rest of the substrates for space-restricted applications. Furthermore, a modified direct-bonded copper is proposed to further improve thermal performance. The evaluation results show that the modified substrate can handle 30% more losses than its traditional counterpart.

Chowdhury, Shajjad↗

Experimental evaluation of thermal-fluids performance of Helium-Cooled Flat Plate (HCFP) divertor

Various helium (He)-cooled solid-tungsten (W) divertor concepts have been proposed for long-pulse magnetic fusion energy reactors. Among these concepts, the He-cooled flat plate divertor (HCFP) modules have the largest plasma-facing surface area of ~0.2 m 2 . Simulations have shown that the most recent version of the design can withstand heat fluxes as great as 8 MW/m 2 . Earlier experimental studies of a single shortened HCFP cooling unit with a slot length of 7.6 cm used air at ambient temperature and pressures below 0.6 MPa. Here, we present initial experimental studies of a copper alloy and steel test section modeling a shortened HCFP cooling unit using He at prototypical pressure of 10 MPa, inlet temperatures T i ≤ 200 °C and steady-state incident heat fluxes q" ≤ 1.2 MW/m 2 . Results for Nusselt number Nu as a function of Reynolds number Re were obtained for Re = 1.2×10 4 –3.4×10 4 , and used to develop a Nu(Re) correlation and validate numerical models of the test section using commercial computational fluid dynamics (CFD) software. Simulations with this model are performed to evaluate the effect of the shortened slot. Furthermore, these analyses are used to estimate the thermal-fluids performance of the HCFP under prototypical conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstrating non-isothermal vacuum membrane air dehumidification for efficient next-generation air conditioning

Vacuum membrane air dehumidification has gained significant interest in recent years as a highly efficient means of air dehumidification. Prior theoretical modeling work by the authors introduced the Active Membrane Energy Exchanger (AMX) concept, which combines active heat exchange and vacuum membrane dehumidification into one non-isothermal system, and found that it could outperform other air conditioning technologies under many conditions. However, no experimental literature exists on combining active heat exchangers and vacuum membrane dehumidification. Here, the goal of the present study is to evaluate the dehumidification (mass transfer) performance of the AMX concept relative to isothermal membrane dehumidification through three main methodologies: (1) membrane material-level characterization, (2) experimental prototype development and testing, and (3) computational fluid dynamics (CFD) simulations. The dense membranes used in this work showed up to a 40% increase in water vapor permeance at cooler temperatures, and the prototype system showed up to a 6% increase in humidity removal when the air was simultaneously cooled. Furthermore, the membrane module-integrated heat exchange tubes provided additional mixing and turbulence, leading to a 4–8% increase in humidity removal. The upper limit coefficient of performance was equal to approximately 2.2, necessitating advanced system designs to improve efficiency. This study is the first to highlight that combining the cooling and vacuum dehumidification processes can improve dehumidification performance.

30 DIRECT ENERGY CONVERSION↗

ExaDigiT/RAPS

ExaDigiT is a framework for developing comprehensive digital twins of liquid-cooled supercomputers, which has three main modules: (1) a python-based Resource Allocator and Power Simulator (RAPS), (2) a Modelica-based Thermo-Fluidic cooling model, and (3) a C++-based augmented reality model built on Unreal Engine 5. RAPS either simulates workloads or replays historical workloads from system telemetry, and is able to predict dynamic energy consumption, as well as interact with the cooling model to predict cooling system behavior. Such a tool can be used together with reinforcement learning algorithms to provide an end-to-end optimization tool for data centers.

Brewer, Wesley [Oak Ridge National Laboratory (ORN↗

datacenterCoolingModel

ExaDigiT is a framework for developing comprehensive digital twins of liquid-cooled supercomputers, which has three main modules: (1) a python-based Resource Allocator and Power Simulator (RAPS), (2) a Modelica-based Thermo-Fluidic cooling model, and (3) a C++-based augmented reality model built on Unreal Engine 5. The Modelica-based cooling model is primarily built-on the open-source Transient Simulation Framework of Reconfigurable Models (TRANSFORM) library and the open-source autocsm library. The library follows the templating architecture developed in the TRANSFORM and the autocsm libraries. This tool can be easily extended to model other Frontier-like liquid cooled supercomputers.

Kumar, Vineet [Oak Ridge National Laboratory (ORNL↗

Improving energy yield in photovoltaic modules with photonic structures

When installed outdoors, Si solar cells typically operate 20 – 30 K above ambient conditions. These elevated operating temperatures lead to diminished performance, reducing efficiency by ~0.4%/K for crystalline Si cells and decreasing module lifetime. Since much of the elevated temperature of the modules derives from parasitic absorption of sub-bandgap sunlight by the contacts, encapsulants, or other materials, reflectors that remove the sub-bandgap radiation from the module before it is absorbed promise to reduce the operating temperature. However, there are many competing strategies to reject this light: selective reflectors could be integrated into the outer module glass, at the textured Si-encapsulant interface, or on the rear. Furthermore, many of these approaches are complex and expensive to fabricate. The issue of heating can be even more critical in bifacial modules: high fractions of rear irradiance can lead to higher operating temperatures. Prior to this project, relatively little was known about the optical strategies for temperature reduction in bifacial modules. The goal of this project was to quantitatively assess optical strategies for improving the energy yield via a combination of improved anti-reflection and sub-bandgap light rejection. We studied two complementary concepts: the performance of ideal structures to determine the upper limits to performance, and low-complexity structures made from standard materials as cost-effective implementations. We also studied the performance of these reflectors in different types of modules, including Al BSF, PERC, and bifacial. Here we build from our prior accomplishments in developing mirror optimization techniques, and make use of simulation methods that accurately capture the optical properties of the modules throughout the visible and near-infrared spectrum. We connect these optical properties to energy yield under realistic, outdoor conditions. We also experimentally fabricated mirrors, incorporated them into mini-modules, and performed outdoor testing of performance at NREL. We found definitively that spectrally-selective mirrors on the outside of the module cover glass offer the best performance, both under ideal conditions and for realistic, low- complexity mirrors. Mirrors at the Si cell/encapsulant interface are limited by the multiple reflections needed to remove sub-bandgap light. Mirrors at the cell surface and mirrors on the rear also cannot remove all the sub-bandgap light, since parasitic absorption also occurs in the cover glass, encapsulant, and front contacts, depending on the module configuration. Also, cell texturing places higher demands on any cell-surface mirror because multiple interactions with the mirror are required to reject sub bandgap light which compounds losses. For bifacial modules, mirrors on the back do provide additional cooling and energy yield improvements, and the mirrors can have the same structure. In the monofacial case up to 3.3K of cooling is possible for mirrors on the front, compared to 2.2K at the cell surface and 1.2K at the rear. For bifacial modules, up to 2.4K of cooling is possible when mirrors are included at both the front and back. Our realistic designs utilize 4 – 6 layers of common photovoltaic materials such as SiO 2 , TiO 2 , and SiN x , making them more cost effective. Finally, we used our models to study thermal management in bifacial modules with different back lamination materials, finding that glass-glass laminated modules operated hotter than equivalent glass-polymer backsheet modules, due solely to the increased absorption of light incident from the rear of the module. Improving the energy yield by 2%, which is achievable with these realistic designs, would lead to LCOE reductions of $0.03/kWh by 2030. These benefits make photovoltaic panels more accessible to the public and may reduce associated maintenance costs.

14 SOLAR ENERGY↗

Summary Report of the FY24 DOE Contributions to the GIF VHTR CMVB

The Generation-IV Forum (GIF) Very-High-Temperature Reactor-Computational Methods Validation and Benchmark (VHTR-CMVB) initiative, involving organizations from Korea Atomic Energy Research Institute (KAERI) (South Korea), Institute of Nuclear and New Energy Technology of Tsinghua University (INET) (China), U.S. Department of Energy (DOE) (U.S.), Joint Research Centre (JRC) (Europe), and Japan Atomic Energy Agency (JAEA) (Japan), is dedicated to the verification and validation of tools for High-Temperature Gas-Cooled Reactors (HTGRs) analysis, using data shared by Computational Methods Validation and Benchmark (CMVB) signatories. For FY24, the US DOE CMVB has committed to several critical activities. Under WP1, led by the US, the integration of the High Temperature Gas Cooled Reactor - Pebble-Bed Module (HTR-PM) Phenomena Identification and Ranking Table (PIRT) into the comparative PIRT is progressing, with a new draft of the comparison tables issued earlier this year and currently being utilized by INET for their contribution. Neutronic validation efforts under WP3 include the preparation of the burnup analysis benchmark, preliminary calculations, and the development of reference models and results. In WP2, a validation exercise for hot gas mixing in the lower plenum of HTR-PM is in progress, using experimental data from INET (China) to validate modeling approaches. A model of the experimental facility has been developed using StarCCM+, with initial calculations slated for presentation at the GIF CMVB meeting this fall. Another WP2 activity focuses on validating numerical models for air-cooled Reactor Cavity Cooling System (RCCS) with experimental data from the Wisconsin Madison RCCS facility. A high-fidelity model, developed using NEK-RS, is currently being validated with available data from a low power forced convection test. These efforts are aimed at enhancing and confirming the accuracy of HTGR analysis tools, ensuring their alignment with experimental data and regulatory requirements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Photonic Refrigeration from Time-Modulated Thermal Emission

We develop theoretical and computational formalisms to describe thermal radiation from temporally modulated systems. We demonstrate that such a modulation results in a photon-based active cooling mechanism. This mechanism has a high thermodynamic performance that can approach the Carnot limit. Our work points to exciting new avenues in active, time-modulated control of thermal emission for cooling and energy harvesting applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling Spectrally-Selective Reflection for Thermal Management in Monofacial and Bifacial Modules

Parasitic absorption in photovoltaic modules is a major source of waste heat, which drives operating temperatures 20-30K above ambient. Spectrally-selective sub-bandgap reflection can reduce parasitic absorption, thereby improving module efficiency and power output. Here, we investigate the performance of 1-D spectrally-selective mirrors in monofacial Al BSF and PERC modules, and bifacial PERC modules. In monofacial modules, these mirrors offer >1.2% increase in energy yield compared to single-layer anti-reflection coatings, while cooling by over 1K on average. Mirrors reduced bifacial module parasitic absorption by up to 34 W/m2 out of 1240 W/m2 incident.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Fourier Analysis-Based Evolutionary Multi-Objective Multiphysics Optimization of Liquid-Cooled Heat Sinks

Optimal heat dissipation in power modules can significantly increase their power density. Removing the generated heat is critical for capturing the benefits of advanced semiconductor materials and improving the reliability of the device operation. This article proposes a design optimization method for liquid-cooled heat sinks that use a Fourier analysis-based tool and an evolutionary optimization algorithm to optimize the heat sink geometry for specified objectives. The optimized heat sink geometry is then compared with state-of-the-art solutions in literature based on finite element analysis of different designs. The proposed methodology can develop complex geometries that outperform the conventional heat sink geometries.

Sahu, Raj↗

Cooling charge determination for a local thermal management system

A system and method for estimating the state of charge, i.e., the amount of cooling remaining, in a latent heat thermal storage module of a local environmental control system. The local environmental control system stores cooling energy at night by freezing a latent heat phase change material (PCM), and then releasing the stored cooling energy by removing heat from room air flowing through the PCM during the day. Differential temperature sensors are used measure the air temperature drop across the latent thermals storage unit and the fan voltage, which is directly related to fan air flow rate, is sampled. A controller is programmed to determine the charging state from these measurements.

Khalifa, H. Ezzat↗

Multiphysics Analyses of the Protected and Unprotected Loss of Forced Cooling Accidents in the HTR-PM

Here, we present the multiphysics simulation results for the protected pressurized and depressurized loss of forced cooling (PLOFC and DLOFC) events in the High-Temperature gas-cooled Reactor--Pebble-bed Module (HTR-PM) equilibrium core using the Griffin-Pronghorn coupled code system. Additionally, this paper discusses the strategy for estimating the spontaneous fission neutron source needed for unprotected events and re-criticality calculations. The solutions of the protected PLOFC and DLOFC events were verified against similar solutions obtained for temperature evolutions from the open literature. Both the average and maximum pebble surface temperatures behaved as expected during the DLOFC and remained below 1800 K. The PLOFC results are highly dependent on the ability to resolve the natural circulation in the core, which is impacted by the mesh resolution in Pronghorn. Furthermore, we present the results of the unprotected DLOFC transient to predict the timing of the re-criticality event, which occurred 47 hours after the onset of the transient, and the new steady-state power of 1.3 MW.

42 - ENGINEERING↗

Magnetron R&D Progress for High Efficiency CW RF Sources of Industrial Accelerators

After the demonstration of using high efficiency magnetron power to combine and aim to drive a radio frequency accelerator at 2450MHz in CW mode [1], we have used trim coils adding to a water-cooled magnetron and three amplitude modulation methods in an open-loop control to further suppress the 120Hz side-band noise to -46.7dBc level. We have also successfully demonstrated the phase-locking to an industrial grade cooking magnetron transmitter at 915MHz with a 75kW CW power delivered to a water load by using a -26.6dBc injection signal. The sideband noise at 360Hz from the 3-Phase SCRs DC power supply can be reduced to -16.2dBc level. Their power combing scheme and higher power application to industrial accelerators are foreseeing.

Wang, H.↗

CFD Simulations of Lower Plenum Mixing

Review of model development and validation performed in the Advanced Reactor Technologies (ART) program for thermal mixing at the outlet of High Temperature Gas Reactors (HTGRs). Understanding the mixing that occurs in the lower plenum in an HTGR is necessary to facilitate design improvements and to perform reactor safety analysis. Numerical models are one possible approach to gain a better understanding of mixing in the lower plenum. Given the complexity of the geometry and the intense mixing present, it is important to perform validation of numerical models. Three models have been developed during FY2025: a porous media with Pronghorn, a Reynolds Averaged Navier Stokes (RANS) with STAR-CCM+, and a Large Eddy Simulation (LES) with NekRS. The reference facility is a scaled-down version of the lower plenum of the High Temperature Gas-Cooled Reactor - Pebble-bed Module (HTR-PM) demonstration reactor. Preliminary results of the porous media and the RANS shows general good agreement against experimental benchmark data. Future work will leverage high-fidelity results obtained through LES to guide model selection and improvements to the lower-fidelity models, with particular attention to the Pronghorn porous media.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗