Search NASA⌕ Search

SEARCH · Search NASA

Results for “module degradation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Exploring Si Heterojunction Solar Cell Degradation: Bulk and Interface Processes Analyzed by Simulations and Experiments in Order to Develop Mitigation Strategies

The Si technology with the highest conversion efficiency is a-Si/c-Si heterojunction (HJ) PV. Its market penetration, however, is slowed by reports that fielded HJ modules degraded at twice the rate of regular c-Si modules. Our very recent work confirmed this degradation and attributed it to enhanced recombination at the a-Si/c-Si interface, caused by the slow, order-of-magnitude increase of the defect density. We propose to comprehensively explore degradation mechanisms in Si HJ cells by combining simulations and experiments. Theoretically, we will: (1) simulate structure of a-Si and a-Si/c-Si interfaces, identify defects; (2) determine statistics of energy barriers that control defect formation; (3) compute growth of defect density from the barrier distribution, and the resulting degradation of Voc. Experimentally, we will: (1) create a series of HJ-cell-representative stacks with varying layer thicknesses and deposition conditions by using PECVD tools; (2) use temperature and injection-dependent lifetime spectroscopy to determine effective lifetimes; (3) deconvolve the data to separate bulk and interface effects, and the effects of charge density and interface defects to analyze long time degradation. The goal is to identify material and device degradation mechanisms, to develop mitigation strategies for improved stability, such as the introduction of capping layers and hydrogen diffusion control.

14 SOLAR ENERGY↗

MODIS Aqua Optical Throughput Degradation Impact on Relative Spectral Response and Calibration on Ocean Color Products

Since Moderate Resolution Imaging Spectroradiometer Aqua's launch in 2002, the radiometric system gains of the reflective solar bands have been degrading, indicating changes in the systems optical throughput. To estimate the optical throughput degradation, the electronic gain changes were estimated and removed from the measured system gain. The derived optical throughput degradation shows a rate that is much faster in the shorter wavelengths than the longer wavelengths. The wavelength-dependent optical throughput degradation modulated the relative spectral response (RSR) of the bands. In addition, the optical degradation is also scan angle-dependent due to large changes in response versus the scan angle over time. We estimated the modulated RSR as a function of time and scan angles and its impacts on sensor radiometric calibration for the ocean science. Our results show that the calibration bias could be up to 1.8 % for band 8 (412 nm) due to its larger out-of-band response. For the other ocean bands, the calibration biases are much smaller with magnitudes at least one order smaller.

Lee, Shihyan↗

Interconnect: Cooperative Research and Development Final Report, CRADA Number CRD-13-00507 (Project 4)

This CRADA modification involves analyses on a variety of CdTe-PV related materials, test structures, solar cells, and modules produced at FSLR and/or NLR and adds analysis related to module degradation and reliability. Materials will be provided by FSLR, NLR, and/or by interleaving FSLR and NLR layers and processes. Module reliability activities will include technical risk assessment, materials characterization, module and test structure characterization, modeling, accelerated test development, and outdoor testing.

14 SOLAR ENERGY↗

Potential-induced degradation in photovoltaic modules: a critical review

Potential-induced degradation (PID) has received considerable attention in recent years due to its detrimental impact on photovoltaic (PV) module performance under field conditions. Both crystalline silicon (c-Si) and thin-film PV modules are susceptible to PID. While extensive studies have already been conducted in this area, the understanding of the PID phenomena is still incomplete and it remains a major problem in the PV industry. Herein, a critical review of the available literature is given to serve as a one-stop source for understanding the current status of PID research. This article also aims to provide an overview of future research paths to address PID-related issues. This paper consists of three parts. In the first part, the modelling of leakage current paths in the module package is discussed. The PID mechanisms in both c-Si and thin-film PV modules are also comprehensively reviewed. The second part summarizes various test methods to evaluate PV modules for PID. The last part focuses on studies related to PID in the omnipresent p-type c-Si PV modules. The dependence of temperature, humidity and voltage on the progression of PID is examined. Preventive measures against PID at the cell, module and system levels are illustrated. Moreover, PID recovery in standard p-type c-Si PV modules is also studied. Most of the findings from p-type c-Si PV modules are also applicable to other PV module technologies.

14 SOLAR ENERGY↗

Electrical Bias as an Alternate Method for Reproducible Measurement of Copper Indium Gallium Diselenide (CIGS) Photovoltaic Modules: Preprint

Light-to-dark metastable changes in thin-film photovoltaic (PV) modules can introduce uncertainty when measuring module performance on indoor flash testing equipment. This study describes a method to stabilize module performance through forward-bias current injection rather than light exposure. Measurements of five pairs of thin-film copper indium gallium diselenide (CIGS) PV modules indicate that forward-bias exposure maintained the PV modules at a stable condition (within 1%) while the unbiased modules degraded in performance by up to 12%. It was additionally found that modules exposed to forward bias exhibited stable performance within about 3% of their long-term outdoor exposed performance. This carrier-injection method provides a way to reduce uncertainty arising from fast transients in thin-film module performance between the time a module is removed from light exposure and when it is measured indoors, effectively simulating continuous light exposure by injecting minority carriers that behave much as photocarriers do. This investigation also provides insight into the initial light-induced transients of thin-film modules upon outdoor deployment.

14 SOLAR ENERGY↗

Photovoltaic design optimization for terrestrial applications

As part of the Jet Propulsion Laboratory's Low-Cost Solar Array Project, a comprehensive program of module cost-optimization has been carried out. The objective of these studies has been to define means of reducing the cost and improving the utility and reliability of photovoltaic modules for the broad spectrum of terrestrial applications. This paper describes one of the methods being used for module optimization, including the derivation of specific equations which allow the optimization of various module design features. The method is based on minimizing the life-cycle cost of energy for the complete system. Comparison of the life-cycle energy cost with the marginal cost of energy each year allows the logical plant lifetime to be determined. The equations derived allow the explicit inclusion of design parameters such as tracking, site variability, and module degradation with time. An example problem involving the selection of an optimum module glass substrate is presented.

Ross, R. G., Jr.↗

Detection and Localization of Damaged Photovoltaic Cells and Modules Using Spread Spectrum Time Domain Reflectometry

The operating efficiency of photovoltaic (PV) plants can be improved if damaged or degraded modules can be detected and identified. Currently, string-level power electronics can detect problems with modules or cabling but not locate them, which would facilitate addressing these issues. Here, we investigate the ability of spread spectrum time domain reflectometry (SSTDR) to both detect and locate/identify damaged cells and modules within a series-connected PV string. We tested the ability of SSTDR to detect and locate single-cell mini-modules and full-sized PV modules, which were intentionally damaged by impacts with a hammer (breaking the glass and damaging the silicon below) or by cutting through some or all busbars. Damage to the glass and silicon of cells was detected and located within a small string of minimodules. Busbar damage was detectable only if an open was created by cutting through all intercell busbars. Furthermore, physical impact damage to the glass and silicon of a full-sized PV module could be detected, but further development of signal processing is needed to achieve localization of such damaged modules within a string.

14 SOLAR ENERGY↗

Performance of a class of parallel spread-spectrum code acquisition schemes in the presence of data modulation

An acquisition procedure for data-modulated direct-sequence spread-spectrum systems is investigated. The correlation time is partitioned into subintervals, and the integration results in these subintervals are noncoherently combined for detection. The tradeoff between noncoherent combining loss and data modulation degradation guides the optimum choice of the number of subintervals. Two forms of data modulation are considered, namely, the alternate-data and random-data cases. The parallel acquisition schemes discussed allow multiple code-phase offsets to be examined at each test. The circular state diagram approach is used to analyze the performances of these schemes. The theory presented is valid for a class of such parallel schemes.

Cheng, Unjeng↗

Field Aging of Photovoltaic Module Packaging Materials: DuraMAT Field Module Library

To understand and develop models for silicon photovoltaic module degradation, accelerated testing is often used, however, outdoor field testing is necessary for validation. Outdoor field testing publications are often limited by the lack of a pristine, control module to compare the fielded module to. In this work, commercially available modules were purchased from seven different manufacturers for outdoor fielding then destructive characterization to investigate packaging material degradation on

14 SOLAR ENERGY↗

Energy Yield Loss Due to LETID

This presentation presents an open-source LETID model part of the PVDegradationTools, which can calculate solar modules degradation due to Light and Elevated Temperature (LETID).

degradation↗

Generalized Spatio-Temporal Model of Backsheet Degradation From Field Surveys of Photovoltaic Modules

Photovoltaic (PV) module backsheets degrade at different rates because of the specific polymeric materials and the local exposure environments of the installations. Studies of real-world backsheet degradation provide valuable information to understand backsheet degradation and failure. Field surveys of PV module backsheets were conducted on 1310 modules in four commercial PV power plant sites with different exposure times. The backsheet's local exposure environment is determined by its location along the rack length and depth, the modules' elevation above the ground, and the ground cover albedo. Backsheets that are installed at the ends of the module rack length exhibit larger degradation rates (with yellowness index difference of 1.14 $\pm$ 0.45 and 7.80 $\pm$ 1.3 for backsheets of poly (ethylene terephthalate) and poly (ethylene naphthalate) as the air-side layer, respectively) than backsheets in the center section of the rack. A generalized spatio-temporal model was developed to predict the large-scale backsheet degradation of different backsheet polymers across time/age and location in the PV power plant rack. The model utilizes a cubic-spline relationship between backsheet degradation and rack length, and a quadratic relationship between backsheet discoloration and rack depth. This generalized spatio-temporal model predicts the outdoor backsheet degradation with an adjusted- $R^2$ range between 0.31 to 0.89. The similarity between this model and the spatial variation of the rear-side irradiance, indicates that the irradiance plays a significant role in outdoor backsheet degradation. The generalized spatio-temporal model can be used to evaluate large scale PV backsheet performance, as well as a guidance for PV site designers and operations and maintenance crews.

14 SOLAR ENERGY↗

Hot-spot heating susceptibility due to reverse bias operating conditions

Because of field experience (indicating that cell and module degradation could occur as a result of hot spot heating), a laboratory test was developed at JPL to determine hot spot susceptibility of modules. The initial hot spot testing work at JPL formed a foundation for the test development. Test parameters are selected as follows. For high shunt resistance cells, the applied back bias test current is set equal to the test cell current at maximum power. For low shunt resistance cells, the test current is set equal to the cell short circuit current. The shadow level is selected to conform to that which would lead to maximum back bias voltage under the appropriate test current level. The test voltage is determined by the bypass diode frequency. The test conditions are meant to simulate the thermal boundary conditions for 100 mW/sq cm, 40C ambient environment. The test lasts 100 hours. A key assumption made during the development of the test is that no current imbalance results from the connecting of multiparallel cell strings. Therefore, the test as originally developed was applicable for single string case only.

Gonzalez, C. C.↗

Fill Factor Loss in Fielded Photovoltaic Modules Due to Metallization Failures, Characterized by Luminescence and Thermal Imaging

Understanding the causes of photovoltaic module failure in the field can be achieved using spatially-resolved imaging tools in combination with current-voltage (IV) characterization. We evaluate 23 field-degraded modules by comparing their IV characteristics with module images obtained by electroluminescence, photoluminescence, UV-fluorescence, and dark lock-in thermography. We identify primarily metallization failures (metallization series resistance, solder point heating, broken fingers, disrupted interconnects) in these modules that has led to a severe drop in the fill factor and up to 35% power loss over only 2 years of deployment.

14 SOLAR ENERGY↗

Model Development of Degradation of PV Modules Backsheet with Locating Place of Module

Performance of a photovoltaic (PV) module is related to the micro-environment around the module. The position of photovoltaic modules in an array row have a large effect on the yellowing and gloss of PV module backsheet exposed in Dfa climatic zone (Gaithersburg, MD) with a polyethylene naphthalate (PEN) outer layer. Stress/Response models of yellowing and gloss-losing as function of location parameters of module, including the shed, row, measurement position in a same module and the distance of module location to the row center, are under development. The module installation height had the greatest influence on degradation of PEN PV backsheet in the Dfa climatic zone. The module backsheets at the end of an array have higher degradation rate (edge effect). The edge effect decreases with increasing of module installation heights.

14 SOLAR ENERGY↗

Comparison of Photovoltaic Module Luminescence Imaging Techniques: Assessing the Influence of Lateral Currents in High-Efficiency Device Structures

We investigate the implications of using partial or patterned illumination for luminescence imaging of photovoltaic modules. Partial illumination induces local photovoltage variations that drive lateral current flow into non-illuminated cell regions, causing the average injection level to vary over the course of luminescence measurement. The extent of lateral current depends on material properties and is especially significant for high-efficiency devices such as the silicon heterojunction with intrinsic thin layer (HIT) modules that we investigate. We compare four module imaging methods including large-area illumination, scanning-laser illumination, contactless electroluminescence, and pattern-illuminated photoluminescence. By evaluating the statistical correlation among the different methods under varying laser fluences, we conclude that most methods converge to similar results at matched photon dose per cell (not laser power density) for the modules that we study, while pattern-illuminated photoluminescence yields distinct images from the other techniques regardless of the illumination power. Our combined analysis using multiple luminescence imaging techniques gives specific insight into the causes of HIT module degradation, including suspected degradation of the transparent conductive oxide and passivation layer.

14 SOLAR ENERGY↗

System-level performance and degradation of 21 GWDC of utility-scale PV plants in the United States

We assess the performance of a fleet of 411 utility-scale (i.e., >5 MWAC and ground-mounted) photovoltaic (PV) projects totaling 21.1 GWDC (16.3 GWAC) of capacity, which achieved commercial operations in the United States from 2007 to 2016. This fleet of projects contributed more than 50% of all solar electricity generated in the United States in 2017. Using detailed information on individual project characteristics, in conjunction with modeled irradiance data, we assess the extent to which actual first-year performance has lived up to both modeled and stated expectations. We then analyze system-level performance degradation in subsequent years by employing a “fixed effects” regression model to statistically isolate the impact of age on system performance. We find that this fleet of utility-scale PV projects has generally lived up to ex ante expectations for first-year performance but that subsequent system-level degradation—found to be −1.3%/year (±0.2%)—has, on average, been worse than both ex ante expectations (commonly −0.5%/year) and results from past studies (ranging from −0.8%/year to −1.0%/year). We emphasize that −1.3%/year is a system-level estimate that captures more than just module degradation (e.g., including soiling, balance of plant degradation, and downtime for maintenance and/or other events). A side analysis of a variety of project characteristics suggests that system-level degradation rates tend to be of lower magnitude among newer projects and larger projects and at sites with lower long-term average temperatures.

14 SOLAR ENERGY↗

Comparing Outdoor to Indoor Performance for Bifacial Modules Affected by Polarization-Type Potential-Induced Degradation

Bifacial photovoltaic (PV) modules have the advantage of using light reflected off of the ground to contribute to power production. Predicting the energy gain is challenging and requires complex models to do so accurately. Often, module degradation over time is neglected in models for the sake of simplicity or is underestimated. Comparing outdoor and indoor current–voltage (I–V) performance for bifacial modules is more challenging than for monofacial modules, as there are additional variables to consider such as rear albedo non-uniformity, cell mismatch, and their effects on temperature. This challenge is compounded when heterogeneous degradation modes occur, such as polarization-type potential-induced degradation (PID-p). To examine the effects of PID-p on I–V predictions using an empirical data-driven approach, 16 bifacial PERC modules are installed outdoors on racks with different albedo conditions. A subset is exposed to high-voltage biases of −1500 V or +1500 V. Outdoor data are traced at irradiance ranges of 150–250 W/m 2 , 500–600 W/m 2 , and 900–1000 W/m 2 . These curves are corrected using control module temperature, wire resistivity, and module resistance measured indoors. We examine several methods to transform indoor I–V curves to accurately, and more simply than existing methods, approximate outdoor performance for bifacial modules without and with varying levels of PID-p degradation. This way, bifacial performance modeling can be more accessible and informed by fielded, degraded modules. Distributions of percent errors between indoor and outdoor performance parameters and Mean Absolute Percent Errors (MAPEs) are used to assess method quality. Results including low-irradiance data (150–250 W/m 2 ) are discussed but are filtered for quantifying method quality as these data introduce substantial errors. The method with the most optimal tradeoff between low MAPE and analysis simplicity involves measuring the front side of a module indoors at an irradiance equal to plane-of-array irradiance plus the product of module bifaciality and albedo irradiance. This method gives MAPE values of 1–6.5% for non-degraded and 1.6–5.9% for PID-p degraded module performance.

14 SOLAR ENERGY↗

Local Resistance Measurement for Degradation of c-Si Heterojunction with Intrinsic Thin Layer (HIT) Solar Modules

Silicon heterojunction with intrinsic thin layer (or HIT) modules typically degrade at a rate of less than 1% annually in solar fields with dominant degradation in open-circuit voltage and some degradation in series resistance. However, detailed mechanisms can differ from module to module. Here, we study increases in local series resistance that occur over long-term field deployment, indicated by cell areas where the photoluminescence intensity does not degrade but the electroluminescence degrades significantly. To directly measure the local series resistance, we have cored out the local electroluminescence-degraded area, and we measured the sheet resistance by 4-point-probe and local nm-scale resistance using scanning spreading resistance microscopy (SSRM). The results by 4-point-probe show scattered sheet resistance that can be caused, for example, by nonuniform current paths through the transparent conductive oxide layer, the a-Si:H emitter, or the near-junction c-Si inversion layer. In contrast, the SSRM results indicate a relatively uniform and non-degraded resistivity on smaller nanometer spatial scales. SSRM is an atomic force microscopy-based two-terminal resistance mapping technique that measures the local resistance in nm-volume beneath the probe. The consistent resistances measured on the control and degraded samples can exclude the degradation of transparent conductive oxide resistance.

41 EE - Solar Energy Technologies Office (EE-4S)↗