Search NASA⌕ Search

SEARCH · Search NASA

Results for “molecular diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

High spectral resolution observations of fluorescent molecular hydrogen in molecular clouds

The 1-0 S(1) line of molecular hydrogen has been observed at high spectral resolution in several sources where the emission was suspected of being fluorescent. In NGC 2023, the Orion Bar, and Parsamyan 18, the S(1) line is unresolved, and the line center close to the rest velocity of the ambient molecular cloud. Such behavior is expected for UV-excited line emission. The H2 line widths in molecular clouds thus can serve as diagnostic for shocked and UV-excitation mechanisms. If the lines are broader than several km/s or velocity shifts are observed across a source it is likely that shocks are responsible for the excitation of the gas.

Burton, Michael G.↗

Hopanoid Biomarker Preservation In Coniform (Phormidium) Stromatolites in Siliceous Thermal Springs, Yellowstone National Park

The microbial communities that characterize modem hydrothermal ecosystems serve as modern analogs to those thought to have dominated early environments on Earth and possibly Mars. The importance of such hydrothermal systems as targets in exploring for an early biosphere on Mars is well established. Such work provides an important basis for the analysis of Martian samples associated with such environments. The surviving molecular structure and isotopic signature of diagnostic lipid biomarkers found as chemical fossils can provide a link between modern bacterially dominated ecosystems and their ancient counterparts. We are interested in the processes involved in the deposition and/or degradation of organic material in moderately thermal, silicifying microbial mats, particularly as this relates to the potential for preservation of some biomarker components known to be more highly resistant to microbial degradation. Several excellent biomarker molecules are associated with the cyanobacteria that dominate these mats, particularly the 2-methylbacteriohopanepolyols (2-MeBHP). These compounds are ubiquitous on Earth and are not easily degraded in nature, a fact documented by their detection in ancient Earth rocks dating back as far as 2,700 Ma.

Jahnke, Linda L.↗

Numerical simulation of the general circulation of the atmosphere of Titan

The atmospheric circulation of Titan is investigated with a general circulation model. The representation of the large-scale dynamics is based on a grid point model developed and used at Laboratoire de Meteorologie Dynamique for climate studies. The code also includes an accurate representation of radiative heating and cooling by molecular gases and haze as well as a parametrization of the vertical turbulent mixing of momentum and potential temperature. Long-term simulations of the atmospheric circulation are presented. Starting from a state of rest, the model spontaneously produces a strong superrotation with prograde equatorial winds (i.e., in the same sense as the assumed rotation of the solid body) increasing from the surface to reach 100 m sec-1 near the 1-mbar pressure level. Those equatorial winds are in very good agreement with some indirect observations, especially those of the 1989 occultation of Star 28-Sgr by Titan. On the other hand, the model simulates latitudinal temperature contrasts in the stratosphere that are significantly weaker than those observed by Voyager 1 which, we suggest, may be partly due to the nonrepresentation of the spatial and temporal variations of the abundances of molecular species and haze. We present diagnostics of the simulated atmospheric circulation underlying the importance of the seasonal cycle and a tentative explanation for the creation and maintenance of the atmospheric superrotation based on a careful angular momentum budget.

NASA Discipline Exobiology↗

Hydrocarbon-Fueled Rocket Engine Plume Diagnostics: Analytical Developments and Experimental Results

A viewgraph presentation describing experimental results and analytical developments about plume diagnostics for hydrocarbon-fueled rocket engines is shown. The topics include: 1) SSC Plume Diagnostics Background; 2) Engine Health Monitoring Approach; 3) Rocket Plume Spectroscopy Simulation Code; 4) Spectral Simulation for 10 Atomic Species and for 11 Diatomic Molecular Electronic Bands; 5) "Best" Lines for Plume Diagnostics for Hydrocarbon-Fueled Rocket Engines; 6) Experimental Set Up for the Methane Thruster Test Program and Experimental Results; and 7) Summary and Recommendations.

Tejwani, Gopal D.↗

Self-consistent Non-LTE Model of Infrared Molecular Emissions and Oxygen Dayglows in the Mesosphere and Lower Thermosphere

We present the new version of the ALI-ARMS (for Accelerated Lambda Iterations for Atmospheric Radiation and Molecular Spectra) model. The model allows simultaneous self-consistent calculating the non-LTE populations of the electronic-vibrational levels of the O3 and O2 photolysis products and vibrational level populations of CO2, N2,O2, O3, H2O, CO and other molecules with detailed accounting for the variety of the electronic-vibrational, vibrational-vibrational and vibrational-translational energy exchange processes. The model was used as the reference one for modeling the O2 dayglows and infrared molecular emissions for self-consistent diagnostics of the multi-channel space observations of MLT in the SABER experiment It also allows reevaluating the thermalization efficiency of the absorbed solar ultraviolet energy and infrared radiative cooling/heating of MLT by detailed accounting of the electronic-vibrational relaxation of excited photolysis products via the complex chain of collisional energy conversion processes down to the vibrational energy of optically active trace gas molecules.

Feofilov, Artem G.↗

Electric Potential and Electric Field Imaging with Dynamic Applications: 2017 Research Award Innovation

The technology and methods for remote quantitative imaging of electrostatic potentials and electrostatic fields in and around objects and in free space is presented. Electric field imaging (EFI) technology may be applied to characterize intrinsic or existing electric potentials and electric fields, or an externally generated electrostatic field may be used for illuminating volumes to be inspected with EFI. The baseline sensor technology (e-Sensor) and its construction, optional electric field generation (quasi-static generator), and current e- Sensor enhancements (ephemeral e-Sensor) are discussed. Critical design elements of current linear and real-time two-dimensional (2D) measurement systems are highlighted, and the development of a three dimensional (3D) EFI system is presented. Demonstrations for structural, electronic, human, and memory applications are shown. Recent work demonstrates that phonons may be used to create and annihilate electric dipoles within structures. Phonon induced dipoles are ephemeral and their polarization, strength, and location may be quantitatively characterized by EFI providing a new subsurface Phonon-EFI imaging technology. Initial results from real-time imaging of combustion and ion flow, and their measurement complications, will be discussed. These new EFI capabilities are demonstrated to characterize electric charge distribution creating a new field of study embracing areas of interest including electrostatic discharge (ESD) mitigation, crime scene forensics, design and materials selection for advanced sensors, combustion science, on-orbit space potential, container inspection, remote characterization of electronic circuits and level of activation, dielectric morphology of structures, tether integrity, organic molecular memory, atmospheric science, and medical diagnostic and treatment efficacy applications such as cardiac polarization wave propagation and electromyography imaging.

Generazio, Ed↗

Sample Processing Instrumentation to Enable Lab-like Analysis of Lipids, Hydrocarbons, and Kerogen in situ

Introduction: Over the last decade, our team based out of NASA Ames Research Center has made advances in fluidic technologies to enable laboratory-grade processes in space environments. More recently, we have designed and developed two instruments that utilize sample processing steps to extract and purify organic molecules that are key targets in the search for life. The first instrument targets soluble lipids and hydrocarbons that have been preserved in soil or rock material for millions to billions of years called ExCALiBR (Extractor for Chemical Analysis of Lipid Biomarkers in Regolith). The second instrument called KAMELOT (Kerogen and Macromolecule Extractor Liberating Organics Thermolytically) targets kerogen or insoluble macromolecular material that reside in the residue left behind after solvent extraction. Together, these instruments can be coupled to existing flight sample acquisition and analytical instrumentation (e.g., mass spectrometers) to achieve our overall science goal of identifying molecular patterns and features that are diagnostic of how the organic matter was synthesized, either through biological or non-biological processes.

Mary Beth Wilhelm↗

Herpesviruses in Saliva and Their Clinical Significance

Saliva has been used as a source of biological markers for a wide spectrum of normal and disease states for a long time. It is a non-invasive, easily accessible, and self-collected body fluid that contains a variety of measurable biological substances. While mostly water, saliva also contains ions, carbohydrates, proteins and peptides, exfoliated cells, nucleic acids, and microorganisms. Saliva can reflect tissue levels of some natural substances and a large variety of molecules introduced for therapeutic use, emotional status; hormonal status, immunological status, neurological effects, and nutritional and metabolic status. It can also be used to monitor a variety of drugs including marijuana, cocaine, and alcohol. It is the most cost-effective approach for screening large population in community mass screening programs and for longitudinal sampling of hospitalized individuals aimed at monitoring viral load dynamics and treatment response. During the COVID-19 pandemic, scientific evidence emerged indicating that molecular tests performed on saliva have diagnostic sensitivity and specificity comparable to those observed with nasopharyngeal swabs for SARS-CoV-2 RNA detection. The presence of IgA and IgG antibodies at the mucosal level has been demonstrated to influence the progression of viral infection and the severity of clinical manifestation. As saliva contains both respiratory secretions and immunological components, it has wide applications, ranging from clinical diagnostics to post-vaccine disease burden and immunity surveillance.

Douglass Diak↗

Exploiting a Shortcoming of Coupled-Cluster Theory: The Extent of Non-Hermiticity as a Diagnostic Indicator of Computational Accuracy

The fundamental non-Hermitian nature of the forms of the coupled-cluster (CC) theory widely used in quantum chemistry has usually been viewed as a negative, but the present paper shows how this can be used to an advantage. Specifically, the non-symmetric nature of the reduced one-particle density matrix (in the molecular orbital basis) is advocated as a diagnostic indicator of computational quality. In the limit of the full coupled-cluster theory [which is equivalent to full configuration interaction (FCI)], the electronic wave function and correlation energy are exact within a given one-particle basis set, and the symmetric character of the exact density matrix is recovered. The extent of the density matrix asymmetry is shown to provide a measure of “how difficult the problem is” (like the well-known T 1 diagnostic), but its variation with the level of theory also gives information about “how well this particular method works”, irrespective of the difficulty of the problem at hand. The proposed diagnostic is described and applied to a select group of small molecules, and an example of its overall utility for the practicing quantum chemist is illustrated through its application to the beryllium dimer (Be 2 ). Future application of this idea to excited states, open-shell systems, and symmetry-breaking problems and an extension of the method to the two-particle density are then proposed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecularly Imprinted Polymer Sensor Empowered by Bound States in the Continuum for Selective Trace-Detection of TGF-beta

The integration of advanced materials and photonic nanostructures can lead to enhanced biodetection capabilities, crucial in clinical scenarios and point-of-care diagnostics, where simplified strategies are essential. Herein, a molecularly imprinted polymer (MIP) photonic nanostructure is demonstrated, which selectively binding to transforming growth factor-beta (TGF-β), in which the sensing transduction is enhanced by bound states in the continuum (BICs). The MIP operating as a synthetic antibody matrix and coupled with BIC resonance, enhances the optical response to TGF-β at imprinted sites, leading to an augmented detection capability, thoroughly evaluated through spectral shift and optical lever analogue readout. The validation underscores the MIP-BIC sensor capability to detect TGF-β in spiked saliva, achieving a limit of detection of 10 fM and a resolution of 0.5 pM at physiological concentrations, with a precision of two orders of magnitude above discrimination threshold in patients. The MIP tailored selectivity is highlighted by an imprinting factor of 52, showcasing the sensor resistance to interference from other analytes. The MIP-BIC sensor architecture streamlines the detection process eliminating the need for complex sandwich immunoassays and demonstrates the potential for high-precision quantification. This positions the system as a robust tool for biomarker detection, especially in real-world diagnostic scenarios.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Molecular line emission models of Herbig-Haro objects. II - HCO(+) emission

We present time-dependent models of the chemistry and temperature of interstellar molecular gas clumps that are exposed to the radiation from propagating stellar-jet shocks. The X-ray, EUV, and FUV radiation from the shock initiates ion chemistry and also heats the gas in the clumps. Using representative parameters, we show that, on the shock transit time between the clumps, the abundances of the ionized molecular species that are produced in the clumps can exceed the values determined from steady state models by several orders of magnitude. Collisional excitation by the heated gas can lead to measurable line emission from several ionized species; as in previous investigations of X-ray-irradiated molecular gas, we find that electron impacts contribute significantly to this process. We apply these results to the interpretation of the HCO(+) line emission that has already been detected in several Herbig-Haro objects. We demonstrate that this picture provides a natural explanation of the fact that the line intensity typically peaks ahead of the associated shock, as well as of the reported low line-center velocities and narrow line widths. We tabulate several diagnostic line intensities of HCO(+) and other molecular species that may be used to infer the physical conditions in the emitting gas.

Wolfire, Mark G.↗

Outer midplane neutral density measurements and H-mode fueling studies in NSTX-U

Neutral density profiles are measured on the outboard midplane of the National Spherical Torus Experiment Upgrade (NSTX-U) using a two dimensional camera (ENDD, edge neutral density diagnostic) filtered for deuterium Balmer α (D α ) emission interpreted via simulations using the Monte Carlo neutral transport code DEGAS 2. Deuterium atomic densities n D are calculated by inverting the line-integrated D α brightness and using local measurements of electron density ne and temperature T e to determine atomic rate coefficients. The assumptions used in the derivation of n D from D α emissivity are validated using DEGAS 2 to estimate contributions to emissivity due to electron impact excitation and molecular processes. In this work, experimental measurements and DEGAS 2 simulations are compared over a database of L- and H-mode discharges, showing good agreement in D α emissivity profiles. Residual disagreement between experiment and simulations is suggestive of the possible role of intermittent transport and uncertainties in the molecular data. DEGAS 2 simulations are further used to complement the ENDD diagnostic, extracting neutral (atomic and molecular) densities at locations where the ENDD measurement are not made or where the assumptions used in the ENDD analysis are not valid. Deuterium atomic densities and ionization profiles on the outer midplane are compared for L-mode and H-mode discharges in NSTX-U. One-way coupling of DEGAS 2 to UEDGE multi-fluid simulations constrained by experimental data is used to study edge fueling and neutral penetration in NSTX-U discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hypersonic wake velocity measurements using acetone molecular tagging velocimetry

Molecular tagging velocimetry, a minimally intrusive laser diagnostic, was used to find quantitative off-body velocity measurements in the wake of both strut-mounted and free-flight spheres in hypersonic flow. Acetone gas seeded in the flow was excited using the fourth harmonic of a pulse-burst Nd:YAG laser. The experimental tests were validated and compared to simulations using a continuous Galerkin flow solver and an adaptive mesh refinement process. Near the centerline in the wake of the sphere, velocities between −105 and 65 m/s were observed due to reverse flow in the viscous shear layer. Similarly, the simulated data showed negative velocity values in the shear layer region. Outside of the shear layer, average velocities of 730 m/s were observed in both the experimental and simulated results. The overall average uncertainty for the strut-mounted and free-flight cases was estimated to have an accuracy of ±4% (±35.5m/s or 4.9%). In conclusion, this non-intrusive technique provides a velocity map of the wake behind a sphere under hypersonic conditions.

42 ENGINEERING↗

JANNAF 35th Combustion Subcommittee Meeting

Volume 1, the first of two volumes is a compilation of 63 unclassified/unlimited distribution technical papers presented at the 35th meeting of the Joint Army-Navy-NASA-Air Force (JANNAF) Combustion Subcommittee (CS) held jointly with the 17th Propulsion Systems Hazards Subcommittee (PSHS) and Airbreathing Propulsion Subcommittee (APS). The meeting was held on 7-11 December 1998 at Raytheon Systems Company and the Marriott Hotel, Tucson, AZ. Topics covered include solid gun propellant processing, ignition and combustion, charge concepts, barrel erosion and flash, gun interior ballistics, kinetics and molecular modeling, ETC gun modeling, simulation and diagnostics, and liquid gun propellant combustion; solid rocket motor propellant combustion, combustion instability fundamentals, motor instability, and measurement techniques; and liquid and hybrid rocket combustion.

Fry, Ronald S.↗

Far-Infrared and Submillimeter Spectroscopy of Low to Moderate Redshift Normal and Active Galaxies

Broadband surveys with planned observatories such as SIRTF, ASTRO-F, NGST, Herschel, SMA, and ALMA will provide large samples of dust-enshrouded galaxies undergoing varying proportions of star formation and accretion onto supermassive black holes. Recent evidence suggests that the mass of supermassive central black holes are proportional to central velocity dispersions of their host galaxy bulges, but it is not yet known how these properties are evolutionarily connected. To trace the evolution of these components during the important luminous, dusty merger episodes as a function of redshift, sensitive mid- to far-infrared spectroscopic diagnostic observations from space will be necessary. The high sensitivity and spatial resolution of a large aperture, natural background limited far-infrared/submillimeter telescope such as SAFAIR will allow detection and identification of the far-infrared/submillimeter components of galaxies and of a multitude of rest-frame mid- to far-infrared recombination, fine-structure, and molecular lines toward dusty galactic nuclei. The line diagnostics beginning to be developed from ISO work will help determine important parameters such as the intrinsic spectral energy distribution, ionization parameters, metallicities, densities, extinction to the embedded energy sources, and ultimately the star-formation and accretion rates in these galaxies. Ultimately, the higher spatial resolution provided by a cold, far-infrared submillimeter interferometer is needed to view the distribution of structure in galaxies in order to unravel the as yet untold story of the evolution of galaxies over the lifetime of the Universe.

Fischer, Jacqueline↗

Demonstration of Imaging Flow Diagnostics Using Rayleigh Scattering in Langley 0.3-Meter Transonic Cryogenic Tunnel

The feasibility of using the Rayleigh scattering technique for molecular density imaging of the free-stream flow field in the Langley 0.3-Meter Transonic Cryogenic Tunnel has been experimentally demonstrated. The Rayleigh scattering was viewed with a near-backward geometry with a frequency-doubled output from a diode-pumped CW Nd:YAG laser and an intensified charge-coupled device camera. Measurements performed in the range of free-stream densities from 3 x 10(exp 25) to 24 x 10(exp 25) molecules/cu m indicate that the observed relative Rayleigh signal levels are approximately linear with flow field density. The absolute signal levels agree (within approx. 30 percent) with the expected signal levels computed based on the well-known quantities of flow field density, Rayleigh scattering cross section for N2, solid angle of collection, transmission of the optics, and the independently calibrated camera sensitivity. These results show that the flow field in this facility is primarily molecular (i.e., not contaminated by clusters) and that Rayleigh scattering is a viable technique for quantitative nonintrusive diagnostics in this facility.

Shirinzadeh, B.↗

Rayleigh Scattering Diagnostic for Measurement of Temperature and Velocity in Harsh Environments

A molecular Rayleigh scattering system for temperature and velocity measurements in unseeded flows is described. The system is capable of making measurements in the harsh environments commonly found in aerospace test facilities, which may have high acoustic sound levels, varying temperatures, and high vibration levels. Light from an argon-ion laser is transmitted via an optical fiber to a remote location where two flow experiments were located. One was a subsonic free air jet; the second was a low-speed heated airjet. Rayleigh scattered light from the probe volume was transmitted through another optical fiber from the remote location to a controlled environment where a Fabry-Perot interferometer and cooled CCD camera were used to analyze the Rayleigh scattered light. Good agreement between the measured velocity and the velocity calculated from isentropic flow relations was demonstrated (less than 5 m/sec). The temperature measurements, however, exhibited systematic errors on the order of 10-15%.

Seasholtz, Richard G.↗

Rayleigh Scattering Diagnostic for Measurement of Temperature, Velocity, and Density Fluctuation Spectra

A molecular Rayleigh scattering technique is developed to measure dynamic gas temperature, velocity, and density in unseeded turbulent flows at sampling rates up to 10 kHz. A high power CW laser beam is focused at a point in a heated air jet plume and Rayleigh scattered light is collected and spectrally resolved. The spectrum of the light, which contains information about the temperature, velocity, and density of the flow, is analyzed using a Fabry-Perot interferometer. The circular interference fringe pattern is divided into four concentric regions and sampled at 1 and 10 kHz using photon counting electronics. Monitoring the relative change in intensity within each region allows for measurement of gas temperature and velocity. Independently monitoring the total scattered light intensity provides a measure of gas density. Power spectral density calculations of temperature, velocity, and density fluctuations, as well as mean and fluctuating quantities are demonstrated for various radial locations in the jet flow at a fixed axial distance from the jet exit plane. Results are compared with constant current anemometry and pitot probe measurements at the same locations.

Mielke, Amy F.↗