Search NASA⌕ Search

SEARCH · Search NASA

Results for “monitoring verification and reporting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Tracer Gas Model Development and Verification in PFLOTRAN

Tracer gases, whether they are chemical or isotopic in nature, are useful tools in examining the flow and transport of gaseous or volatile species in the underground. One application is using detection of short-lived argon and xenon radionuclides to monitor for underground nuclear explosions. However, even chemically inert species, such as the noble gases, have bene observed to exhibit non-conservative behavior when flowing through porous media containing certain materials, such as zeolites, due to gas adsorption processes. This report details the model developed, implemented, and tested in the open source and massively parallel subsurface flow and transport simulator PFLOTRAN for future use in modeling the transport of adsorbing tracer gases.

07 ISOTOPE AND RADIATION SOURCES↗

Puck and Puck/SAW Loop Seals (Final Report)

Tamper-indicating devices (TIDs), also known as seals, play a crucial role in various sectors including international nuclear safeguards, arms control, domestic security, and commercial products, by ensuring that monitored or high-value items are not accessed undetected. These devices do not block access but alert to unauthorized tampering. With adversaries' capabilities evolving, there's a pressing need for seals to advance in terms of effectiveness (e.g., better tamper indication and unique identification), and new technology can improve the efficiency of installation and verification. Passive loop seals, widely used in international nuclear safeguards to ensure that continuity of knowledge is maintained on declared items, face stringent International Atomic Energy Agency (IAEA) requirements that surpass those met by commercial products. The metal cup seal (Figure 1, left), a staple IAEA seal, is robust but requires significant resources for post-use verification – specifically, the seal’s unique identity can only be verified at IAEA headquarters after removal from facilities. Further, the seal has been in use for decades and seal types should periodically be replaced to counter adversarial efforts for defeating seals. In 2020, the IAEA outlined about 40 requirements for a new passive loop seal, aiming for in-situ verification, minimal external tool use, unique identification (UID), and clear tamper indication. In response, research and development efforts focused on creating a new passive loop seal that meets these criteria and in 2022 the IAEA announced the completion of the Field Verifiable Passive Loop Seal (FVPS) (Figure 1, right). Concurrently to the IAEA’s efforts, Sandia National Laboratories (SNL) and Oak Ridge National Laboratory (ORNL) designed, developed, and tested two seal versions – Puck and Puck/SAW, with Puck based on the IAEA’s requirements and including a novel visually-obvious tamper response, and Puck/SAW adding additional beneficial capabilities like the ability to receive a unique identifier from a standoff distance and monitoring the wire integrity. Puck/SAW was specifically designed and developed to address sealing applications in dry spent fuel storage facilities, where the number of sealed spent fuel containers results in heavy verification burden and inspector safety issues related to radiation exposure. These efforts are described in this Executive Summary.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The Ten Lockheed Martin Cyber-Physical Challenges: Formalized, Analyzed, and Explained

Capturing and analyzing requirements of Cyber-Physical Systems (CPS) can be challenging, since CPS models typically involve time-varying and real-valued variables, physical system dynamics, or even adaptive behavior. MATLAB/Simulinkis a development and simulation framework that is widely used in industry to capture such systems. In this paper, we report on the application of NASA Ames tools to perform end-to-end analysis of the Ten Lockheed Martin Challenge Problems (LMCPS). LMCPS is a set of industrial Simulink model benchmarks and natural language requirements developed by domain experts. Our framework, which integrates the tools FRET and COCOSIM, is used to: 1) elicit, explain, and formalize the semantics of the given natural language requirements; 2) generate verification code and monitors that can be automatically attached to the Simulink models; 3) perform verification by using SMT-based model checkers. FRET and COCOSIM are open source, and can be used by other researchers and practitioners to replicate our case study. We provide a categorization of recurring patterns in the formalization of the requirements and discuss the strengths and weaknesses of our automated verification approach.

Anastasia Mavridou↗

Can Aerosol Direct Radiative Effects Account for Analysis Increments of Temperature in the Tropical Atlantic?

In the late 1990's, prior to the launch of the Terra satellite, atmospheric general circulation models (GCMs) did not include aerosol processes because aerosols were not properly monitored on a global scale and their spatial distributions were not known well enough for their incorporation in operational GCMs. At the time of the first GEOS Reanalysis (Schubert et al. 1993), long time series of analysis increments (the corrections to the atmospheric state by all available meteorological observations) became readily available, enabling detailed analysis of the GEOS-1 errors on a global scale. Such analysis revealed that temperature biases were particularly pronounced in the Tropical Atlantic region, with patterns depicting a remarkable similarity to dust plumes emanating from the African continent as evidenced by TOMS aerosol index maps. Yoram Kaufman was instrumental encouraging us to pursue this issue further, resulting in the study reported in Alpert et al. (1998) where we attempted to assess aerosol forcing by studying the errors of a the GEOS-1 GCM without aerosol physics within a data assimilation system. Based on this analysis, Alpert et al. (1998) put forward that dust aerosols are an important source of inaccuracies in numerical weather-prediction models in the Tropical Atlantic region, although a direct verification of this hypothesis was not possible back then. Nearly 20 years later, numerical prediction models have increased in resolution and complexity of physical parameterizations, including the representation of aerosols and their interactions with the circulation. Moreover, with the advent of NASA's EOS program and subsequent satellites, atmospheric aerosols are now monitored globally on a routine basis, and their assimilation in global models are becoming well established. In this talk we will reexamine the Alpert et al. (1998) hypothesis using the most recent version of the GEOS-5 Data Assimilation System with assimilation of aerosols. We will explicitly calculate the impact of aerosols on the temperature analysis increments in the tropical Atlantic and assess the extent to which inclusion of atmospheric aerosols have reduced these increments.

General Circulation Models↗

Development of a Portable In Situ Phosphorous Sensor

While phosphorus is a critical nutrient for all forms of life, runoff leads to phosphorus accumulation in surface water where it can cause a variety of health, environmental, and economic problems. The Department of Energy is interested in conducting long-term field experiments to monitor the impact of phosphorus in terrestrial and aquatic environments, and to better understand a cost vs. benefit analysis of reducing phosphorus pollution. Performing such long-term experiments requires affordable sensors capable of monitoring low-level phosphorus concentrations under challenging environmental conditions. However, such sensors are currently not available. The goal of this proposed project is to develop and demonstrate a low-cost portable phosphorus sensor suitable for in situ measurements. We will determine the technical requirements for a Raman-based sensor system, design and build a signal amplifier, integrate it with a Raman-based sensor, and demonstrate a proof-of-concept level sensor system. The expected accomplishments for Phase I include the identification of the technical requirements of a combined Raman laser/spectrometer and cavity enhancement system, building a proof-of-concept level sensor system capable of detecting orthophosphate compounds at the desired level of 0.25 mg P/L and organic P compounds, and verification of the sensor performance under laboratory and field conditions. In addition, we will identify initial hardening requirements that will need to be implemented during Phase II. While we plan to develop an integrated sensor system for monitoring phosphorus, the cavity-based enhancement system can also be used in combination with other (non-phosphorus) Raman sensors that we plan to develop or that are already commercially available. A recent market report highlights the increasing demand for such environmental monitoring applications, with the market for chemical detection anticipated to grow at a compound annual growth rate of 6.5% (2020-2025). Wide-spread monitoring of phosphorus could reduce the damage from eutrophication in freshwater, which is estimated to be $2.2 billion annually, thereby increasing biodiversity, reducing costs required for drinking water treatment, and decreasing economic losses related to recreation and angling and lake property values.

54 ENVIRONMENTAL SCIENCES↗

CY2020 Annual Closure Monitoring Report for Corrective Action Unit 98: Frenchman Flat, Underground Test Area, Nevada National Security Site, Nevada (January 2020–December 2020, Revision 1)

This report presents the results of monitoring conducted for water quality, water levels, and institutional controls in calendar year (CY) 2020 by the U.S. Department of Energy (DOE), Environmental Management (EM) Nevada Program’s Underground Test Area (UGTA) Activity at Corrective Action Unit (CAU) 98, Frenchman Flat (FF), at the Nevada National Security Site (NNSS), Nevada (Figure 1-1). This report also presents analytical laboratory results (including results of quality assurance/quality control samples, such as field duplicates [FDs]); and verification of use restrictions (URs), institutional controls, and water use. Groundwater samples were collected; water levels were measured; and well site surveillance was conducted in support of the Underground Test Area (UGTA) Closure Report for Corrective Action Unit 98: Frenchman Flat, Nevada National Security Site, Nevada (NNSA/NFO, 2016) and its ensuing Records of Technical Change (ROTCs).

54 ENVIRONMENTAL SCIENCES↗

Refining Principal Stress Measurements in Reservoir Underburden in Regions of Induced Seismicity through Seismological Tools, Laboratory Experiments - Final Technical Report

This project developed methodologies to measure the in-situ principal stress in the deep subsurface through use of multiple independent, but complementary, seismic methods, laboratory verification, and development of theoretical frameworks. By leveraging existing regional and local datasets we developed, tested, and refined a set of diagnostic tools for determining the in-situ stress state with reduced uncertainty at and below reservoir depths (1.5-6 km). A set of novel tools was produced that are scale independent, such that their utility is equivalent on regional, field scale, and near borehole monitoring of principal stresses in reservoir underburden for carbon storage projects. During a 4-year Department of Energy (DOE) and Southern Company funded project, carried out by the Electric Power Research Institute (EPRI), Lawrence Livermore National Laboratory (LLNL), the University of Oklahoma (OU), and the U.S. Geological Survey (USGS), the project team developed methodologies to measure the far-field in-situ principal stress in the deep subsurface, leveraging induced seismicity data from waste-water disposal projects. These methodologies consisted in the use of well-established and technically advanced seismic processing methods, such as virtual seismometer method-moment tensor (VSM-MT) and shear wave splitting (SWS), that are adept at recovering the stress orientation and certain components of the stress tensor. These methods were applied to robust seismicity catalogs created with matched filter techniques near sites of active fluid disposal—a proxy for carbon storage sites where such datasets are more limited. Estimates of the stress orientation made with seismic processing tools were considered along with laboratory acoustic emission experiments conducted on rock samples from the region of interest. Stress orientations in the studied region do not vary significantly across distances of ~100 km, nor are they found to rotate through time as a consequence of local wastewater disposal, as previously speculated. Finally, the project team investigated the trade-offs among the different seismic methods and evaluated the range of uncertainty that is generated with these methodologies, which led to a practical use and refinement of the VSM-MT technique when it is applied to field datasets. Understanding the trade-offs between these different methods highlighted the potential benefits of improved quantification of uncertainties on stress field estimations.

58 GEOSCIENCES↗

Sensor to User - NASA/EOS Data for Coastal Zone Management Applications Developed from Integrated Analyses: Verification, Validation and Benchmark Report

The NASA Applied Sciences Program seeks to transfer NASA data, models, and knowledge into the hands of end-users by forming links with partner agencies and associated decision support tools (DSTs). Through the NASA REASoN (Research, Education and Applications Solutions Network) Cooperative Agreement, the Oceanography Division of the Naval Research Laboratory (NRLSSC) is developing new products through the integration of data from NASA Earth-Sun System assets with coastal ocean forecast models and other available data to enhance coastal management in the Gulf of Mexico. The recipient federal agency for this research effort is the National Oceanic and Atmospheric Administration (NOAA). The contents of this report detail the effort to further the goals of the NASA Applied Sciences Program by demonstrating the use of NASA satellite products combined with data-assimilating ocean models to provide near real-time information to maritime users and coastal managers of the Gulf of Mexico. This effort provides new and improved capabilities for monitoring, assessing, and predicting the coastal environment. Coastal managers can exploit these capabilities through enhanced DSTs at federal, state and local agencies. The project addresses three major issues facing coastal managers: 1) Harmful Algal Blooms (HABs); 2) hypoxia; and 3) freshwater fluxes to the coastal ocean. A suite of ocean products capable of describing Ocean Weather is assembled on a daily basis as the foundation for this semi-operational multiyear effort. This continuous realtime capability brings decision makers a new ability to monitor both normal and anomalous coastal ocean conditions with a steady flow of satellite and ocean model conditions. Furthermore, as the baseline data sets are used more extensively and the customer list increased, customer feedback is obtained and additional customized products are developed and provided to decision makers. Continual customer feedback and response with new improved products are required between the researcher and customer. This document details the methods by which these coastal ocean products are produced including the data flow, distribution, and verification. Product applications and the degree to which these products are used successfully within NOAA and coordinated with the Mississippi Department of Marine Resources (MDMR) is benchmarked.

Hall, Callie↗

W.A. Parish Post-Combustion CO 2 Capture and Sequestration Demonstration Project (Final Technical Report)

The Petra Nova Project (Project) is a commercial scale post-combustion carbon capture project developed by a joint venture between NRG Energy, Inc. (NRG) and JX Nippon Oil Exploration (EOR) Limited (JX). The Project is designed to separate and capture carbon dioxide (CO2) from an existing coal-fired unit’s flue gas slipstream at NRG’s W.A. Parish Electric Generating Station (WAP) located southwest of Houston, Texas. The captured CO2 is dried, compressed, and transported via an 81-mile pipeline to the West Ranch oilfield (West Ranch) in Jackson County, Texas, where it is injected to boost oil production. The Project, which is partially funded by a grant (Grant) from the United States (U.S.) Department of Energy (DOE) under the Clean Coal Power Initiative (CCPI) Round 3, uses the Kansai Mitsubishi Carbon Dioxide Recovery advanced amine-based CO 2 absorption technology (KM-CDR Process®), which was jointly developed by Mitsubishi Heavy Industries, Ltd. (MHI) and the Kansai Electric Power Co. Inc., to treat and capture at least ninety percent (90%) of the CO 2 from a 240-megawatt equivalent (MWe) flue gas slipstream off of Unit 8 at WAP. When operating at full capacity, the Project captures approximately 5,200 short tons of CO 2 per day, which would otherwise be emitted into the atmosphere, representing the largest commercial scale deployment of post-combustion CO2 capture technology at a coal power plant to date. Under the Grant, the Project was managed in 3 phases: (1) Phase 1: Project Definition / Front End Engineering Design (FEED) (2) Phase 2: Detailed Engineering, Procurement & Construction (3) Phase 3: Demonstration and Monitoring. On December 29, 2016, commercial operation of the Project was achieved, ending Phase 2 and starting Phase 3, a 3-year demonstration period running from January 1, 2017 through December 31, 2019. The key objectives of Phase 3 were to (a) demonstrate the specific advanced technologies constructed during Phase 2 and (b) monitor the injected CO 2 at West Ranch to demonstrate technologies and protocols for monitoring, verification, and accounting (MVA). As of the end of Phase 3, Petra Nova captured 3,904,978 short tons of CO 2 (3,542,537 metric tons) that was transported to West Ranch. To support the DOE obligation to monitor, verify, and account for the sequestered CO 2 at West Ranch, Petra Nova contracted with the Bureau of Economic Geology (in the Jackson School of Geosciences at The University of Texas at Austin) to (a) design a monitoring program, (b) draft an MVA Plan for DOE review and approval, and (c) working with Petra Nova and the operator of West Ranch to manage and report on the MVA activity. This report discussed the technical aspects of the project during each of the 3 phases of the project as identified above.

01 COAL, LIGNITE, AND PEAT↗

National CO 2 budgets (2015–2020) inferred from atmospheric CO 2 observations in support of the global stocktake

Accurate accounting of emissions and removals of CO 2 is critical for the planning and verification of emission reduction targets in support of the Paris Agreement. Here, we present a pilot dataset of country-specific net carbon exchange (NCE; fossil plus terrestrial ecosystem fluxes) and terrestrial carbon stock changes aimed at informing countries' carbon budgets. These estimates are based on “top-down” NCE outputs from the v10 Orbiting Carbon Observatory (OCO-2) modeling intercomparison project (MIP), wherein an ensemble of inverse modeling groups conducted standardized experiments assimilating OCO-2 column-averaged dry-air mole fraction (X CO 2 ) retrievals (ACOS v10), in situ CO 2 measurements or combinations of these data. The v10 OCO-2 MIP NCE estimates are combined with “bottom-up” estimates of fossil fuel emissions and lateral carbon fluxes to estimate changes in terrestrial carbon stocks, which are impacted by anthropogenic and natural drivers. These flux and stock change estimates are reported annually (2015–2020) as both a global 1° x 1° gridded dataset and a country-level dataset and are available for download from the Committee on Earth Observation Satellites' (CEOS) website. Across the v10 OCO-2 MIP experiments, we obtain increases in the ensemble median terrestrial carbon stocks of 3.29–4.58 Pg CO2 yr -1 (0.90–1.25 Pg C yr -1 ). This is a result of broad increases in terrestrial carbon stocks across the northern extratropics, while the tropics generally have stock losses but with considerable regional variability and differences between v10 OCO-2 MIP experiments. We discuss the state of the science for tracking emissions and removals using top-down methods, including current limitations and future developments towards top-down monitoring and verification systems.

54 ENVIRONMENTAL SCIENCES↗

Report on Field Test at INL Cask Farm of Single Detector Fast Neutron Spent Fuel Cask Verification System

Detecting diversion of spent fuel elements in dry storage casks is challenging due to the thick shielding used in cask construction. Measurements on top of the cask to map the underlying arrangement of the fuel elements and looking for anomalous changes over time has proven difficult to achieve using gamma rays due to the high scattering and attenuation from the thick steel structure, weakening information on the present or absence of fuel bundles. Simulations and laboratory experiments suggest that the high-energy neutron flux (>200 keV) measured directly above each fuel bundle is sufficient to produce a position map that enables detection of the present or absence of fuel bundles, and therefore diversion of a spent fuel bundle. A single-detector spent-fuel monitoring technique based on this principle was development at the Lawrence Livermore National Laboratory (LLNL). The INL Cask Farm in the INTEC technical area at Idaho National Laboratory (INL) offers the capability to test this technique on an MC-10 storage cask which has a distribution of full and empty fuel positions. An experimental test plan for the single-detector verification system was developed in consultation with INL personnel to be completed in FY2021. Due to travel advisories related to COVID-19, the experimental test plan was adapted to enable INL personnel to carry out the measurements in consultation with LLNL personnel following shipment of the LLNL system to INL. Field test measurements of the single detector verification system were successfully carried out at the INL cask farm on September 7-9, 2021. This document summarizes results of the field test.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Utilizing a Virtual Sodium-Cooled Fast Reactor Digital Twin to Aid in Diversion Pathway Analysis for International Safeguards Applications

We report digital twin technology has the potential to improve the effectiveness of international safeguards inspectors by providing a tool which can: first, perform an accurate diversion path analysis, identify their indicators, and required sensors to detect them; and second, monitor facilities in real-time using critical data streams that benefit from this safeguards-by-design approach. Safeguards inspectors are required to visit facilities and verify the nuclear material to ensure no diversion has taken place and detect misuse of the facility; however, this analysis and verification effort is time consuming, and with limited funding it is imperative that time spent at a nuclear facility is focused on key areas. A virtual digital twin of three prototypic sodium fast reactors was developed, where diversion and misuse scenarios were explored to determine how a digital twin could provide inspectors with an understanding of how proliferation may occur and where the most likely areas for proliferation would be. For each of the three reactors, an optimization algorithm was able to find core designs which would be difficult to detect via sensors alone; however, the use of a machine learning adapter provided by the digital twin was able to show general trends in where proliferation as likely to take place.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of Thermal Control and Protective Coatings

This final report is concerned with the tasks performed during the contract period which included spacecraft coating development, testing, and applications. Five marker coatings consisting of a bright yellow handrail coating, protective overcoat for ceramic coatings, and specialized primers for composites (or polymer) surfaces were developed and commercialized by AZ Technology during this program. Most of the coatings have passed space environmental stability requirements via ground tests and/or flight verification. Marker coatings and protective overcoats were successfully flown on the Passive Optical Sample Assembly (POSA) and the Optical Properties Monitor (OPM) experiments flown on the Russian space station MIR. To date, most of the coatings developed and/or modified during this program have been utilized on the International Space Station and other spacecraft. For ISS, AZ Technology manufactured the 'UNITY' emblem now being flown on the NASA UNITY node (Node 1) that is docked to the Russian Zarya (FGB) utilizing the colored marker coatings (white, blue, red) developed by AZ Technology. The UNITY emblem included the US American flag, the Unity logo, and NASA logo on a white background, applied to a Beta cloth substrate.

Mell, Richard J.↗

A Mode-Shape-Based Fault Detection Methodology for Cantilever Beams

An important goal of NASA's Internal Vehicle Health Management program (IVHM) is to develop and verify methods and technologies for fault detection in critical airframe structures. A particularly promising new technology under development at NASA Langley Research Center is distributed Bragg fiber optic strain sensors. These sensors can be embedded in, for instance, aircraft wings to continuously monitor surface strain during flight. Strain information can then be used in conjunction with well-known vibrational techniques to detect faults due to changes in the wing's physical parameters or to the presence of incipient cracks. To verify the benefits of this technology, the Formal Methods Group at NASA LaRC has proposed the use of formal verification tools such as PVS. The verification process, however, requires knowledge of the physics and mathematics of the vibrational techniques and a clear understanding of the particular fault detection methodology. This report presents a succinct review of the physical principles behind the modeling of vibrating structures such as cantilever beams (the natural model of a wing). It also reviews two different classes of fault detection techniques and proposes a particular detection method for cracks in wings, which is amenable to formal verification. A prototype implementation of these methods using Matlab scripts is also described and is related to the fundamental theoretical concepts.

Tejada, Arturo↗

Pacific Northwest National Laboratory Annual Site Environmental Report for Calendar Year 2019 (Final Report)

The PNNL Annual Site Environmental Report is prepared to meet the requirements of DOE Order 231.1B, Environmental, Safety and Health Reporting, and DOE Order 458.1, Radiation Protection of the Public and the Environment, assuring that the public is informed of any PNNL Richland Campus or PNNL Sequim Campus event that could adversely affect the health and safety of the public, site staff, or the environment. The report provides a synopsis of ongoing environmental management performance and compliance activities for operations that occur on the PNNL Richland Campus in Richland, Washington, and at the PNNL Sequim Campus near Sequim, Washington. It describes the location of and background for each facility; addresses compliance with applicable DOE, federal, state, and local regulations and site-specific permits; documents environmental monitoring efforts and their status; presents potential radiation doses to staff and the public in the surrounding areas; and describes DOE-required data quality assurance methods used for data verification.

54 ENVIRONMENTAL SCIENCES↗

Pacific Northwest National Laboratory Annual Site Environmental Report for Calendar Year 2022 (Final Report)

Pacific Northwest National Laboratory (PNNL), one of the U.S. Department of Energy (DOE) Office of Science’s 10 national laboratories, provides innovative science and technology development in the areas of energy and the environment, fundamental and computational science, and national security. There are three DOE offices within the Richland area. Two are responsible for the Hanford Site, whereas the Pacific Northwest Site Office (PNSO) oversees PNNL. PNNL prepares this Annual Site Environmental Report to meet the requirements of DOE Order 231.1B, Environmental, Safety and Health Reporting, and DOE Order 458.1, Radiation Protection of the Public and the Environment, assuring that the public is informed of any PNNL-Richland Campus or PNNL-Sequim Campus event that could adversely affect the health and safety of the public, site staff, or the environment. The report provides a synopsis of ongoing environmental management performance and compliance activities for operations that occur on the PNNL-Richland Campus in Richland, Washington, and at the PNNL-Sequim Campus near Sequim, Washington. It describes the location of and background for each facility; addresses compliance with applicable DOE, federal, state, and local regulations, and site-specific permits; documents environmental monitoring efforts and their status; presents potential radiation doses to staff and the public in the surrounding areas; and describes DOE-required data quality assurance methods used for data verification. The ASER summarizes site compliance with federal, state, and local environmental laws, regulations, policies, directives, permits, and Orders, and provides environmental management performance benchmarks and their status to the public, regulatory agencies, community officials, Native American tribes, and public interest groups.

54 ENVIRONMENTAL SCIENCES↗

Pacific Northwest National Laboratory Annual Site Environmental Report for Calendar Year 2024

The report provides a synopsis of ongoing environmental management performance and compliance activities for operations that occur at the PNNL-Richland campus in Richland, Washington, and at the PNNL-Sequim campus near Sequim, Washington. It describes the location of and background for each facility; addresses compliance with applicable DOE, federal, state, and local regulations, and site-specific permits; documents environmental monitoring efforts and their status; presents potential radiation doses to staff and the public in the surrounding areas; and describes DOE-required data quality assurance methods used for data verification.

54 ENVIRONMENTAL SCIENCES↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring - Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant low activity waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAW stacks are 815–55,758 scfm for LV-S1, 980–112,078 scfm for LV-S2, 264–22,901 scfm for LV-S3, and 981–79,832 scfm for LV-C2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAW facility. Flow angle results were primarily less than 10°, except for one LV-S2 Fan A result, which was 13.2°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 1.5 COV and 9.2% COV, which were all within the range of the target % COV values from the scale model tests. Based on these stack verification test results, the four LAW filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan operating conditions for LV-S1 and LV-S2, dual-fan operations for LV-S3 at both the continuous air monitor and record sampler locations, and both the single-fan as well as the dual-fan operations for LV-C2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗