Search NASA⌕ Search

SEARCH · Search NASA

Results for “monochromators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A simple method for mitigating error in the fixed-offset of a double-crystal monochromator

In order to maintain a constant monochromatic synchrotron X-ray beam height for all energies, the separation between the crystals of a double-crystal monochromator is typically adjusted, via translation of the second crystal, while X-ray energy is varied, via rotation of the crystal pair. The ability to accurately translate the second crystal requires precise knowledge of the separation between the two crystals and, when present, crystal miscuts. Here, a simple method for calibrating the crystal gap from measured variation in the X-ray beam height that eliminates error in the fixed beam offset is provided.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reducing heat load density with asymmetric and inclined double-crystal monochromators: principles and requirements revisited

Asymmetric double-crystal monochromators (aDCMs) and inclined DCMs (iDCMs) can significantly expand the X-ray beam footprint and consequently reduce the heat load density and gradient. Based on rigorous dynamical theory calculations, the major principles and properties of aDCMs and iDCMs are presented to guide their design and development, particularly for fourth-generation synchrotrons. In addition to the large beam footprint, aDCMs have very large bandwidths (up to ∼10 eV) and angular acceptance, but the narrow angular acceptance of the second crystal requires precise control of the relative orientations and strains. Based on Fourier coupled-wave diffraction theory calculations, it is rigorously proved that the iDCM has almost the same properties as the conventional symmetric DCM, including the efficiency, angular acceptance, bandwidth, tuning energy range and sensitivity to misalignment. The exception is that, for the extremely inclined geometry that can achieve very large footprint expansion, the iDCM has (beneficially) a larger bandwidth and wider angular acceptance. Inclined diffraction has the `rho-kick effect' that can be cancelled by the second reflection of the iDCM (even with misalignment), except that inhomogeneous strains may cause non-uniform rho-kick angles. At present, fabrication/mounting-induced strains pose low risk since they can be controlled to <0.5 µrad over large areas. The only uncertain challenge is the thermally induced strains, yet it is estimated that these strains are naturally lowered by the large footprint and may be further mitigated by optimized cryogenic cooling to the 1–2 µrad level. Overall, aDCMs and iDCMs have more stringent requirements than normal DCMs, but they are feasible schemes in practice.

asymmetric monochromator↗

Twist-Angle-Dependent Excitons in Moiré MoTe 2 Visualized by Cryogenic STEM and Monochromated EELS

van der Waals twisted bilayers of transition-metal dichalcogenides exhibit diverse excitonic phenomena arising from moiré superlattices and lattice reconstruction. While interlayer strain and relaxation reshape their electronic bands, their nanoscale influence on the excitonic fine structure remains poorly understood. Here, we study the interplay between spin–orbit coupling (SOC) and the moiré lattice by probing excitons in H-type twisted (∼8-layer × 8-layer) MoTe 2 using atomic-resolution scanning transmission electron microscopy (STEM) combined with monochromated electron energy loss spectroscopy (EELS) at cryogenic temperature. Spatially resolved spectra reveal moiré-site-dependent variations in excitonic absorption, including modulation of the X B exciton across the moiré unit cell. We find that SOC in MoTe 2 increases with the twist angle within the studied range (2–4.5°), with the largest value observed at 4°. Furthermore, these findings establish the twist angle as a tunable parameter for SOC via moiré engineering and link local structural relaxation to excitonic fine structure in twisted MoTe 2 .

cryogenic STEM/EELS↗

The extreme ultraviolet split and femtosecond delay unit at the plane grating monochromator beamline PG2 at FLASH

An extreme ultraviolet split and femtosecond delay unit based on grazing incidence Mach-Zehnder geometry has been designed and implemented on the plane grating monochromator beamline PG2 at FLASH, the Free Electron Laser at DESY. This device splits the FLASH radiation into two beams, which can independently be steered, filtered and temporally delayed between -5.1 and +5.1 ps with uncertainty in the temporal accuracy of 210 as. To demonstrate the performance of this device, we have performed longitudinal coherence studies of FLASH radiation as well as measured the pulse length by nonlinear two-photon double-ionization in helium.

43 PARTICLE ACCELERATORS↗

Commissioning of a Soft X-ray Beamline PF-BL-16A with a Variable-Included-Angle Varied-Line-Spacing Grating Monochromator

The design and commissioning of a new soft X-ray beamline, BL-16A, at the Photon Factory is presented. The beamline consists of a pre-focusing mirror, an entrance slit, a variable-included-angle varied-line-spacing plane grating monochromator, and a post-focusing system as usual, and provides circularly and linearly polarized soft X rays in the energy range 200-1500 eV with an APPLE-II type undulator. The commissioning procedure for the beamline optics is described in detail, especially the check of the focal position for the zero-th order and diffracted X rays.

43 PARTICLE ACCELERATORS↗

Fully automated, fixed exit, in vacuum double-multilayer monochromator for synchrotron-based hard X-ray micro-imaging applications

We present a double multilayer monochromator (DMM) design which has been realized for the BAMline(BESSY-II light source, Germany) as well as in an updated version for the TopoTomo beamline (ANKA light source. Germany)[1-4]. The latter contains two pairs of multilayer stripes in order to avoid absorption edges of the coating material. For both DMMs, the second multilayer offers a meridional bending option for beam compression to increase the available photon flux density. Each multilayer mirror is equipped with a vertical stage for height adjustments allowing for compensation of varying incoming beam heights and giving a certain flexibility choosing the offset. The second multilayer can be moved in the beam direction in order to cover the full energy range available. Furthermore, a white beam option is available.

43 PARTICLE ACCELERATORS↗

Design of soft x-ray wide-band multilayer gratings for constant deviation monochromators

Constant deviation condition performing scanning energy by the rotation of grating around itself is the one of the most practical mounting for grating monochromators. Conventional multilayer coating can obtain high diffraction efficiency merely in a narrow band width. It is found that a new modified multilayer structure on the laminar-type grating intended to enhance the diffraction efficiency for constant deviation condition shows the diffraction efficiency over 5% in a wide band range of 1.5-2.5 keV in calculation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An energy dispersive bent Laue monochromator for K-edge subtraction imaging

K-Edge Subtraction (KES) is a powerful synchrotron imaging method that allows the quantifiable determination of a contrast element (e.g. iodine) and matrix material (usually represented as water) in both projection imaging and computed tomography. A bent Laue monochromator has been developed that has very good focal and energy dispersive properties for KES. Approximately 5% of the vertical beam profile is involved in “edge crossing” energies, thus no splitter is employed as has been done with previous implementations where approximately 33% of the beam size was blocked. The beam can be narrowed vertically allowing a smaller crossover angle than a splitter based system which minimizes artifacts. The combination of good spatial resolution, energy dispersive properties, flux and a unique approach to data analysis make this system nearly ideal for KES.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-energy focusing Laue monochromator for the diamond light source x-ray pair distribution function beamline I15-1

The I15-1 beamline, the new side station to I15 at the Diamond Light Source, will be dedicated to the collection of atomic pair distribution function data. A Laue monochromator will be used consisting of three silicon crystals diffracting X-rays at a common Bragg angle of 2.83°. The crystals use the (1 1 1), (2 2 0), and (3 1 1) planes to select 40, 65, and 76 keV X-rays, respectively, and will be bent meridionally to horizontally focus the selected X-rays onto the sample. All crystals will be cut to the same optimized asymmetry angle in order to eliminate image broadening from the crystal thickness. Finite element calculations show that the thermal distortion of the crystals will affect the image size and bandpass.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of weak link channel-cut crystals for fast QEXAFS monochromators

A weak link channel-cut crystal, optimized for dedicated Quick EXAFS monochromators and measurements, was designed using finite element analysis. This channel-cut crystal offers precise detuning capabilities to enable suppression of higher harmonics in the virtually monochromatic beam. It was optimized to keep the detuning stable, withstanding the mechanical load, which occurs during oscillations with up to 50 Hz. First tests at DELTA (Dortmund, Germany), proved the design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A table-top monochromator for tunable femtosecond XUV pulses generated in a semi-infinite gas cell: Experiment and simulations

We present a new design of a time-preserving extreme-ultraviolet (XUV) monochromator using a semi-infinite gas cell as a source. The performance of this beamline in the photon-energy range of 20 eV–42 eV has been characterized. We have measured the order-dependent XUV pulse durations as well as the flux and the spectral contrast. XUV pulse durations of ≤40 fs using 32 fs, 800 nm driving pulses were measured on the target. The spectral contrast was better than 100 over the entire energy range. A simple model based on the strong-field approximation is presented to estimate different contributions to the measured XUV pulse duration. On-axis phase-matching calculations are used to rationalize the variation of the photon flux with pressure and intensity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-energy-resolution X-ray monochromator calibration using the detailed-balance principle

A new method is presented to calibrate an X-ray energy scale with sub-meV relative accuracy by using the detailed-balance principle of the phonon creation and annihilation. This method is conveniently used to define or verify the energy scale of high-energy-resolution monochromators that are used in inelastic X-ray scattering and nuclear resonant inelastic X-ray scattering instruments at synchrotron radiation facilities. This method does not rely on sample properties and its precision only depends on the statistical data quality. Well calibrated instruments are essential for reliable comparison of data sets obtained at different synchrotron radiation beamlines, of data with theoretical predictions, and of data from other techniques such as neutron or light scattering. The principle of the detailed-balance method is described in this paper and demonstrated experimentally.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of a bent Laue double-crystal beam-expanding monochromator

A bent Laue double-crystal monochromator system has been designed for vertically expanding the X-ray beam at the Canadian Light Source's BioMedical Imaging and Therapy beamlines. Expansion by a factor of 12 has been achieved without deteriorating the transverse coherence of the beam, allowing phase-based imaging techniques to be performed with high flux and a large field of view. However, preliminary studies revealed a lack of uniformity in the beam, presumed to be caused by imperfect bending of the silicon crystal wafers used in the system. Results from finite-element analysis of the system predicted that the second crystal would be most severely affected and has been shown experimentally. It has been determined that the majority of the distortion occurs in the second crystal and is likely caused by an imperfection in the surface of the bending frame. Here, measurements were then taken to characterize the bending of the crystal using both mechanical and diffraction techniques. In particular, two techniques commonly used to map dislocations in crystal structures have been adapted to map local curvature of the bent crystals. One of these, a variation of Berg–Berrett topography, has been used to quantify the diffraction effects caused by the distortion of the crystal wafer. This technique produces a global mapping of the deviation of the diffraction angle relative to a perfect cylinder. Finally, this information is critical for improving bending and measuring tolerances of imperfections by correlating this mapping to areas of missing intensity in the beam.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗