Search NASA⌕ Search

SEARCH · Search NASA

Results for “motion filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Adaptive filtering of biodynamic stick feedthrough in manipulation tasks on board moving platforms

A novel approach to suppress the effects of biodynamic interference is presented. An adaptive noise canceling technique is employed for substracting the platform motion correlated components from the control stick output. The effects of biodynamic interference and its suppression by adaptive noise cancellation has been evaluated in a series of tracking tasks performed in a moving base simulator. Simulator motions were in pitch, roll and combined pitch and roll. Human operator performance was assessed from the mean square values of the tracking error and the control activity. The tracking error and the total stick output signal were found to increase significantly with motion and to diminish substantially with adaptive noise cancellation, thus providing a considerable improvement in tracking performance under conditions in which platform motion were present. The adaptive filter was found to cause a significant increase in the cross-over frequency and decrease in the phase margin. Moreover, the adaptive filter was found to significantly improve the human operator visual motor response. This improvement is manifested as an increased human operator gain, a smaller time delay and lower pilot workload.

Velger, M.↗

Functional Near Infrared Spectroscopy: Watching the Brain in Flight

Functional Near Infrared Spectroscopy (fNIRS) is an emerging neurological sensing technique applicable to optimizing human performance in transportation operations, such as commercial aviation. Cognitive state can be determined via pattern classification of functional activations measured with fNIRS. Operational application calls for further development of algorithms and filters for dynamic artifact removal. The concept of using the frequency domain phase shift signal to tune a Kalman filter is introduced to improve the quality of fNIRS signals in realtime. Hemoglobin concentration and phase shift traces were simulated for four different types of motion artifact to demonstrate the filter. Unwanted signal was reduced by at least 43%, and the contrast of the filtered oxygenated hemoglobin signal was increased by more than 100% overall. This filtering method is a good candidate for qualifying fNIRS signals in real time without auxiliary sensors

Harrivel, Angela↗

Functional Near Infrared Spectroscopy: Watching the Brain in Flight

Functional Near Infrared Spectroscopy (fNIRS) is an emerging neurological sensing technique applicable to optimizing human performance in transportation operations, such as commercial aviation. Cognitive state can be determined via pattern classification of functional activations measured with fNIRS. Operational application calls for further development of algorithms and filters for dynamic artifact removal. The concept of using the frequency domain phase shift signal to tune a Kalman filter is introduced to improve the quality of fNIRS signals in real-time. Hemoglobin concentration and phase shift traces were simulated for four different types of motion artifact to demonstrate the filter. Unwanted signal was reduced by at least 43%, and the contrast of the filtered oxygenated hemoglobin signal was increased by more than 100% overall. This filtering method is a good candidate for qualifying fNIRS signals in real time without auxiliary sensors.

Harrivel, Angela↗

Software Processes SAR Motion-Measurement Data

Motion Measurement Processor (MMP) is one of three computer programs that are used together in the operation of a terrain-mapping dual-frequency interferometric synthetic-aperture-radar (SAR) system. The other two programs - Jurassicprok and Calibration Processor - are described in the two immediately preceding articles. MMP acquires all the motion and attitude data collected by onboard instrumentation systems, including radar, laser and camera metrology, inertial navigation systems, and Global Positioning System (GPS) receivers. MMP combines all this information and processes it into all the trajectory information needed to run Jurassicprok, which performs the interferometric processing and mapping functions. MMP includes several Kalman filters for combining and smoothing aircraft motion and attitude data, and least-squares inversion and filtering software tools for solving for interferometric baseline lengths. MMP synchronizes the motion and radar data. It combines the various measurement data into a unified, seven-dimensional reference system and puts out the resulting filtered trajectory and attitude data along with instructions for use of the data by Jurassicprok, as well as the command files used to operate Jurassicprok.

Freedman, Adam↗

Optimal washout for control of a moving base simulator

A general form of an optimal washout filter is derived using state-space linear optimal control theory, and this is applied to the design of washout filters of various types of moving base motion simulators, including the NASA's vertical motion simulator. Attention is given to the linear elements of a washout filter. One of the nonlinearities considered is braking which may be required near the end of the simulator excursion to prevent a crash. Although the general form of the optimal washout filter is applicable to time-variant system, the applications analyzed in the study are restricted to time-invariant cases.

Kurosaki, M.↗

Multirate and event-driven Kalman filters for helicopter flight

A vision-based obstacle detection system that provides information about objects as a function of azimuth and elevation is discussed. The range map is computed using a sequence of images from a passive sensor, and an extended Kalman filter is used to estimate range to obstacles. The magnitude of the optical flow that provides measurements for each Kalman filter varies significantly over the image depending on the helicopter motion and object location. In a standard Kalman filter, the measurement update takes place at fixed intervals. It may be necessary to use a different measurement update rate in different parts of the image in order to maintain the same signal to noise ratio in the optical flow calculations. A range estimation scheme that accepts the measurement only under certain conditions is presented. The estimation results from the standard Kalman filter are compared with results from a multirate Kalman filter and an event-driven Kalman filter for a sequence of helicopter flight images.

Sridhar, Banavar↗

Radar ice motion interferometry

Tandem pairs of ERS-1/2 radar observations of the Jakobshavn glacier, in Greenland, were used to estimate the ice motion. Interferograms are made from two such pairs, separated by the 35 day repeat cycle. Motion can be estimated from these without knowledge of the local topography. Although the temporal baseline of the interferograms was only one day, the correlation from the fast moving ice was very low. Because of the resulting phase noise, a scene-dependent filter was used to help unwrap the interferograms. For the upper part of the glacier, the filter worked well. The filter and the measured ice motion are presented.

Goldstein, Richard↗

Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex

Functional near infrared spectroscopy (fNIRS) is an emerging optical neuroimaging technology that indirectly measures neuronal activity in the cortex via neurovascular coupling. It quantifies hemoglobin concentration ([Hb]) and thus measures the same hemodynamic response as functional magnetic resonance imaging (fMRI), but is portable, non-confining, relatively inexpensive, and is appropriate for long-duration monitoring and use at the bedside. Like fMRI, it is noninvasive and safe for repeated measurements. Patterns of [Hb] changes are used to classify cognitive state. Thus, fNIRS technology offers much potential for application in operational contexts. For instance, the use of fNIRS to detect the mental state of commercial aircraft operators in near real time could allow intelligent flight decks of the future to optimally support human performance in the interest of safety by responding to hazardous mental states of the operator. However, many opportunities remain for improving robustness and reliability. It is desirable to reduce the impact of motion and poor optical coupling of probes to the skin. Such artifacts degrade signal quality and thus cognitive state classification accuracy. Field application calls for further development of algorithms and filters for the automation of bad channel detection and dynamic artifact removal. This work introduces a novel adaptive filter method for automated real-time fNIRS signal quality detection and improvement. The output signal (after filtering) will have had contributions from motion and poor coupling reduced or removed, thus leaving a signal more indicative of changes due to hemodynamic brain activations of interest. Cognitive state classifications based on these signals reflect brain activity more reliably. The filter has been tested successfully with both synthetic and real human subject data, and requires no auxiliary measurement. This method could be implemented as a real-time filtering option or bad channel rejection feature of software used with frequency domain fNIRS instruments for signal acquisition and processing. Use of this method could improve the reliability of any operational or real-world application of fNIRS in which motion is an inherent part of the functional task of interest. Other optical diagnostic techniques (e.g., for NIR medical diagnosis) also may benefit from the reduction of probe motion artifact during any use in which motion avoidance would be impractical or limit usability.

Harrivel, Angela↗

Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex

Functional near infrared spectroscopy (fNIRS) is an emerging optical neuroimaging technology that indirectly measures neuronal activity in the cortex via neurovascular coupling. It quantifies hemoglobin concentration ([Hb]) and thus measures the same hemodynamic response as functional magnetic resonance imaging (fMRI), but is portable, non-confining, relatively inexpensive, and is appropriate for long-duration monitoring and use at the bedside. Like fMRI, it is noninvasive and safe for repeated measurements. Patterns of [Hb] changes are used to classify cognitive state. Thus, fNIRS technology offers much potential for application in operational contexts. For instance, the use of fNIRS to detect the mental state of commercial aircraft operators in near real time could allow intelligent flight decks of the future to optimally support human performance in the interest of safety by responding to hazardous mental states of the operator. However, many opportunities remain for improving robustness and reliability. It is desirable to reduce the impact of motion and poor optical coupling of probes to the skin. Such artifacts degrade signal quality and thus cognitive state classification accuracy. Field application calls for further development of algorithms and filters for the automation of bad channel detection and dynamic artifact removal. This work introduces a novel adaptive filter method for automated real-time fNIRS signal quality detection and improvement. The output signal (after filtering) will have had contributions from motion and poor coupling reduced or removed, thus leaving a signal more indicative of changes due to hemodynamic brain activations of interest. Cognitive state classifications based on these signals reflect brain activity more reliably. The filter has been tested successfully with both synthetic and real human subject data, and requires no auxiliary measurement. This method could be implemented as a real-time filtering option or bad channel rejection feature of software used with frequency domain fNIRS instruments for signal acquisition and processing. Use of this method could improve the reliability of any operational or real-world application of fNIRS in which motion is an inherent part of the functional task of interest. Other optical diagnostic techniques (e.g., for NIR medical diagnosis) also may benefit from the reduction of probe motion artifact during any use in which motion avoidance would be impractical or limit usability.

Harrivel, Angela↗

Coordinated adaptive washout for motion simulators.

This paper introduces a new method of providing motion cues to a moving base six-degree-of-freedom flight simulator utilizing nonlinear filters. Coordinated adaptive filters, used to coordinate translational and rotational motion, are derived based on the method of continuous steepest descent, and the basic concept of the digital controllers used for the uncoordinated heave and yaw cues is also presented. The coordinated adaptive washout method is illustrated by an application in a six-degree-of-freedom fixed-base environment.

Parrish, R. V.↗

Direct adaptive impedance control of manipulators

An adaptive scheme for controlling the end-effector impedance of robot manipulators is presented. The proposed control system consists of three subsystems: a simple filter which characterizes the desired dynamic relationship between the end-effector position error and the end-effector/environment contact force, an adaptive controller which produces the Cartesian-space control input required to provide this desired dynamic relationship, and an algorithm for mapping the Cartesian-space control input to a physically realizable joint-space control torque. The controller does not require knowledge of either the structure or the parameter values of the robot dynamics, and it is implemented without calculation of the robot inverse kinematic transformation. As a result, the scheme represents a very general and computationally efficient approach to controlling the impedance of both nonredundant and redundant manipulators. Furthermore, the method can be applied directly to trajectory tracking in free-space motion by removing the impedance filter.

Colbaugh, R.↗

Space infrared telescope pointing control system. Infrared telescope tracking in the presence of target motion

The use of charge-coupled-devices, or CCD's, has been documented by a number of sources as an effective means of providing a measurement of spacecraft attitude with respect to the stars. A method exists of defocussing and interpolation of the resulting shape of a star image over a small subsection of a large CCD array. This yields an increase in the accuracy of the device by better than an order of magnitude over the case when the star image is focussed upon a single CCD pixel. This research examines the effect that image motion has upon the overall precision of this star sensor when applied to an orbiting infrared observatory. While CCD's collect energy within the visible spectrum of light, the targets of scientific interest may well have no appreciable visible emissions. Image motion has the effect of smearing the image of the star in the direction of motion during a particular sampling interval. The presence of image motion is incorporated into a Kalman filter for the system, and it is shown that the addition of a gyro command term is adequate to compensate for the effect of image motion in the measurement. The updated gyro model is included in this analysis, but has natural frequencies faster than the projected star tracker sample rate for dim stars. The system state equations are reduced by modelling gyro drift as a white noise process. There exists a tradeoff in selected star tracker sample time between the CCD, which has improved noise characteristics as sample time increases, and the gyro, which will potentially drift further between long attitude updates. A sample time which minimizes pointing estimation error exists for the random drift gyro model as well as for a random walk gyro model.

Powell, J. D.↗

A Sub-filter Scale Noise Equation far Hybrid LES Simulations

Hybrid LES/subscale modeling approaches have an important advantage over the current noise prediction methods in that they only involve modeling of the relatively universal subscale motion and not the configuration dependent larger scale turbulence . Previous hybrid approaches use approximate statistical techniques or extrapolation methods to obtain the requisite information about the sub-filter scale motion. An alternative approach would be to adopt the modeling techniques used in the current noise prediction methods and determine the unknown stresses from experimental data. The present paper derives an equation for predicting the sub scale sound from information that can be obtained with currently available experimental procedures. The resulting prediction method would then be intermediate between the current noise prediction codes and previously proposed hybrid techniques.

Goldstein, Marvin E.↗

Intercomparison of polar motion measurements during the MERIT period

Polar motion estimates obtained by satellite laser ranging (SLR) and VLBI are analyzed and compared. The JPL Kalman filter was utilized to smooth the polar motion estimates. Variations in the smoothing residuals for the X and Y components of polar motion for SLR and VLBI are examined. It is observed that the rms differences between the SLR and VLBI estimates for X and Y are about 2-3 marcsec. Power spectra of the differences are studied in order to measure possible periodic systematic errors. The data reveal that the SLR and VLBI polar motion data have a rms difference of about 15-20 marcsec and no significant systematic errors.

Steppe, J. A.↗

Multiple object tracking with non-unique data-to-object association via generalized hypothesis testing

A generalized hypothesis testing approach is applied to the problem of tracking several objects where several different associations of data with objects are possible. Such problems occur, for instance, when attempting to distinctly track several aircraft maneuvering near each other or when tracking ships at sea. Conceptually, the problem is solved by first, associating data with objects in a statistically reasonable fashion and then, tracking with a bank of Kalman filters. The objects are assumed to have motion characterized by a fixed but unknown deterministic portion plus a random process portion modeled by a shaping filter. For example, the object might be assumed to have a mean straight line path about which it maneuvers in a random manner. Several hypothesized associations of data with objects are possible because of ambiguity as to which object the data comes from, false alarm/detection errors, and possible uncertainty in the number of objects being tracked. The statistical likelihood function is computed for each possible hypothesized association of data with objects. Then the generalized likelihood is computed by maximizing the likelihood over parameters that define the deterministic motion of the object.

Porter, D. W.↗

Detection of Mental State and Reduction of Artifacts Using Functional Near Infrared Spectroscopy (FNIRS)

fNIRS may be used in real time or near-real time to detect the mental state of individuals. Phase measurement can be applied to drive an adaptive filter for the removal of motion artifacts in real time or near-real time. In this manner, the application of fNIRS may be extended to practical non-laboratory environments. For example, the mental state of an operator of a vehicle may be monitored, and alerts may be issued and/or an autopilot may be engaged when the mental state of the operator indicates that the operator is inattentive.

Harrivel, Angela↗

Estimation With Range Depended Sensor Model

This paper focuses on the improvement of object detection accuracy taking into account the sensor’s reading degradation as the relative range increases. The approach is based on the assumption that range measurement error depends on the actual range. Specifically, we model the measurement error as a proportional to the actual range term plus a zero-mean, Gaussian distributed, and uncorrelated process. The tracking problem is considered in a mixed continuous-discrete time domain, where the target dynamics is in continuous-time and the measurements are in discrete-time, which is an optimal choice in many tracking and navigation applications. We adopt a commonly used continuous time coordinate-uncoupled white-noise acceleration model for a point object to describe the target motion, and use Extended Kalman Filter (EKF) framework to estimate the target's state and the unknown proportionality coefficient.

Vahram Stepanyan↗

Observer-Based Magnetic Bearing Controller Developed for Aerospace Flywheels

A prototype of a versatile, observer-based magnetic bearing controller for aerospace flywheels was successfully developed and demonstrated on a magnetic bearing test rig (see the photograph) and an actual flywheel module. The objective of this development included a fast, yet low risk, control development process, and a robust, high-performance controller for a large variety of flywheels. This required a good system model, an efficient development procedure, and a model-based controller that addressed the key problems associated with flywheel and bearing imbalance, sensor error, and vibration. The model used in this control development and tuning procedure included the flexible rotor dynamics and motor-induced vibrations. Such a model was essential for low-risk scheduling of speed-dependent control parameters and for reliable evaluation of novel control strategies. The successfully tested control prototype utilized an extended Kalman filter to estimate the true rotor principal-axis motion from the raw sensor position feedback. For control refinement, the extended Kalman filter also estimated and eliminated the combined effects of mass-imbalance and sensor runouts from the input data. A key advantage of the design based on the extended Kalman filter is its ability to accurately estimate both the rotor's principal-axis position and gyroscopic rates with the least amount of phase lag. This is important for control parameter scheduling to dampen the gyroscopic motions. Because of large uncertainties in the magnetic bearing and imbalance characteristics, this state-estimation scheme alone is insufficient for containing the rotor motion within the desired 1-mil excursion radius. A nonlinear gain adjustment based on an estimation of the principal-axis orbit size was needed to provide a coarse (nonoptimal), but robust, control of the orbit growth. Control current minimization was achieved with a (steepest gradient) search of synchronous errors in the principal-axis position input data. Actual flywheel tests of this observer-based controller (developed entirely in-house) at the NASA Glenn Research Center showed that the model correctly predicted the rotor orbit growth as a function of rotational speed, and it demonstrated the capability of gain adjustments to arrest this growth. Data from these tests on an actual flywheel module spun to 26,000 rpm proved that the controller was able to contain the shaft motion to within much less than 0.5 mils of radial excursion with axis currents less than 300 mA in root-mean-square estimate. The test speed range was limited because of thermal expansion concerns for this particular flywheel unit, not because of any deficiency in the controller. Simulations for this unit indicated that the controller should be robust up to its top operating speed of 60,000 rpm. Aside from these important achievements, and most significantly, it took less than 1 week to adapt this controller from the simple test rig to the actual flywheel and to demonstrate full five-axis levitation and control. This demonstration showed that both the controller and the model-based development and tuning framework are easily adaptable to a wide range of rotors and bearing configurations and, hence, are capable of reducing design risks and costs for many future flywheel technology developments.

Le, Dzu K.↗