Search NASA⌕ Search

SEARCH · Search NASA

Results for “multi-parameter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

83 records · Page 5

Hybrid Approaches to Systems Health Management and Prognostics

To facilitate and solve the prediction problem, awareness of the current health state of the system is key, since it is necessary to perform condition-based predictions. To accurately predict the future state of any system, it is required to possess knowledge of its current health state and future operational conditions. Latest achievements of data-driven algorithms in regression of complex nonlinear functions and classification tasks have generated a growing interest in artificial intelligence for industrial applications. Complex multi-physics models as well as digital twins, once purely built on physics and corresponding simplified lumped parameter iterations, can now benefit from machine learning algorithms to mitigate the lack of understanding of some complex behavior. Given models of the current and future system behavior, a general approach of model-based prognostics can solve the prediction problem and further decision making. In principle, data driven approaches can replace expensive experimental test-setups as well as reduce the number of simulations needed to explore, e.g., the parametric space of a multi-parameter model. Nonetheless, the limitations of pure data-driven methods came to light rather quickly, at least for some industries. In many industrial applications, data acquisition is costly, and the volume of data that can be collected does not satisfy the requirements for an effective model training and cross-validation. Therefore, some recent works in the area of machine learning is focusing on blending physics with data-driven algorithms, thus mitigating the drawbacks of the two approaches and emphasizing respective advantages. Partial physical knowledge of the problem can aid the learning process by “guiding” the algorithm towards efficient solutions that satisfy the physics driving the system behavior. The result is a hybrid modeling approach combining physical knowledge as well data driven methods to develop a unified hybrid approach. A hybrid framework for fusing information from physics-based performance models along with deep learning algorithms for prognostics of complex safety critical systems is presented. In this framework, physics-based performance models infer unobservable model parameters related to the system's components health solving a calibration problem in the deep learning approach.

Systems Health Management↗

New Ways of Facilitating Improved Data Discovery and Access for NASA's Suborbital Earth Science Observations

NASA conducts field research in various Earth Science disciplines utilizing airborne and other non-satellite platforms to acquire in situ and remotely sensed observations indicative of physical processes across a range of scales. Field efforts are key in the development and validation of instruments and satellite algorithm refinements. The heterogeneous data, with a range of file formats, scales, and acquisition methods, support research in several science areas. NASA’s archive process assigns data products to discipline-oriented Distributed Active Archive Centers (DAACs) for stewardship. Over time, individual DAACs have developed tools for data browsing and serving disparate user bases. As science becomes more interdisciplinary, researchers need to incorporate observations from multiple campaigns, and multiple DAACs, into their work. Motivated in part by this shifting paradigm of needs, the Catalog of Archived Suborbital Earth Science Investigations (CASEI) was created. CASEI provides a single starting point to browse, search, and discover airborne and field data. Contextual metadata are organized and inter-linked allowing intuitive, integrated exploration across all NASA DAACs. Campaign science objectives, platform and instrument configurations, geographical details, geophysical concepts, and more are tracked in CASEI’s database, facilitating multi-parameter search, browse, and discovery of relevant data products. Researchers are able to directly access associated data products, via DOI links, regardless of the DAAC where they reside. Significant events, key time periods of high science interest within the longer-duration campaign effort, are also indicated and allow for a more efficient identification of critical data subsets. This presentation describes CASEI’s development, intensive metadata curation process, and demonstrates the web interface experience. Initial content metrics and plans for continued maintenance will also be discussed.

metadata↗

Hybrid Model Based Approaches for Systems Health Management and Prognostics

This is a previously approved and published presentation. To accurately predict the future state of any system, it is required to possess knowledge of its current health state and future operational conditions. Present achievements of data-driven algorithms in regression of complex nonlinear functions and classification tasks have generated a growing interest in artificial intelligence for industrial applications. Complex multi-physics models as well as digital twins, once purely built on physics and corresponding simplified lumped parameter iterations, can now benefit from machine learning algorithms to mitigate the lack of understanding of some complex behavior. Given models of the current and future system behavior, a general approach of model-based prognostics can solve the prediction problem and further decision-making. In principle, data-driven approaches can replace expensive experimental test-setups as well as reduce the number of simulations needed to explore, e.g., the parametric space of a multi-parameter model. Nonetheless, the limitations of pure data-driven methods came to light rather quickly, at least for some industries. In many industrial applications, data acquisition is costly, and the volume of data that can be collected does not satisfy the requirements for effective model training and cross-validation. Therefore, some recent works in the area of machine learning is focusing on blending physics with data-driven algorithms, thus mitigating the drawbacks of the two approaches and emphasizing respective advantages. Partial physical knowledge of the problem can aid the learning process by “guiding” the algorithm towards efficient solutions that satisfy the physics driving the system behavior. The result is a hybrid modeling approach combining physical knowledge as well data-driven methods to develop a unified hybrid approach. A hybrid framework for fusing information from physics-based performance models along with deep learning algorithms for prognostics of complex safety-critical systems is presented. In this framework, physics-based performance models infer unobservable model parameters related to the system's components health solving a calibration problem in the deep learning approach.

Prognostics↗

Towards Energy Scale Calibration and Drift Correction of TES Detectors for Athena X-IFU

The Athena X-Ray Integral Field Unit (X-IFU) comprises a 2376-pixel array of transition edge sensors (TES) read out with time-division multiplexing (TDM). X-IFU will provide spatially resolved, high-resolution spectroscopy (2.5 eV full-width-half-maximum up to 7 keV) over the energy range 0.2 to 12 keV, with an absolute energy scale accuracy of 0.4 eV. The energy scale function maps the optimally filtered pulse height, in arbitrary engineering units, to real calibrated energy. Uncertainties in the calibration can result from imperfect fitting of the energy scale between the known calibration points. Furthermore, temporal changes in the TES operating environment, such as heat-sink temperature, magnetic field and bias voltage, can cause significant variations in the detector gain function over time. If not properly corrected, this can result in degradation of the energy resolution, and systematic errors in the absolute energy scale. The non-linear nature of TES detectors, coupled with the possibility of multiple simultaneously occurring sources of drift, can make effective corrections over the full bandpass of the instrument extremely challenging. Athena X-IFU will employ an on-board calibration source that provides known reference x-ray lines. This provides real-time monitoring of the gain stability of the detector system and information that can be used to correct for gain drifts. For X-IFU the baseline approach is to measure a series of calibration curves under different environmental conditions, which bound the expected drifts the instrument is predicted to see over the course of the mission. Using the information from the in-flight calibration source, these energy scale functions can be interpolated to generate a new corrected energy scale as a function of time. In this paper we discuss progress towards demonstrating that the X-IFU energy scale requirements can be met. We present measurements on ~ 200 pixels in a prototype X-IFU array read out with 8-column x 32-row TDM. We use a rotating target source containing 12 fluorescent targets to generate x-ray lines covering the energy range 4 keV (Sc-Kα) to 12 keV (Br-Kα). We present measurements of the non-linear energy scale function and show how variations in heat-sink temperature, TES bias voltage and magnetic field affect the shape of TES energy scale differently and introduce different residual gain errors over the bandpass. We explore different drift correction algorithms that use either a single or multiple referential lines to track and correct the gain from these various sources of drift. In addition to the pulse-height, the DC ‘baseline’ level of the TES can contain information about its bias conditions. Thus, we test a multi-parameter gain correction algorithm that attempts to incorporate both the pulse height and the additional baseline information into the algorithm.

Stephen J Smith↗

Development of a Multi-Gas Microsensor Array for the Exploration Portable Life Support System

The Portable Life Support System (PLSS) of the Exploration Extravehicular Mobility Unit (xEMU) requires sensors capable of measuring the major constituents of the gas stream. These major constituents include oxygen, carbon dioxide, and water vapor. The sensors must operate across a wide range of flow and pressure conditions and introduce very low pressure drop in the ventilation loop. The sensors must operate with low power and occupy a small volume. This paper reports the development of a compact, low power, multi-parameter astronaut life support sensor (M-PALSS). M-PALSS consists of an array of low-power chemical microsensors for oxygen, carbon dioxide, water vapor, and pressure. M-PALSS includes custom electronics to control the sensors and is packaged in a custom housing that meets the volume and shape requirements for service in the PLSS.

James Makel↗

100 kHz High-Spectral-Resolution NO-PLIF Measurements for Compressible Flows

In the present work, we use a burst-mode laser and optical parametric oscillator system to perform high-spectral resolution NO-PLIF measurements of an underexpanded jet at a repetition-rate of 100 kHz, with the motivation of multi-parameter measurements of temperature, pressure, and velocity. The laser frequency of the 1064 nm seed laser for the burst-mode laser was scanned during the burst to cover two neighboring absorption line pairs near 226 nm. The peak PLIF signal intensity varies along the axial (z) direction of the underexpanded jet as the laser frequency is scanned, which we attribute to the collisional shift induced by the flow and only revealed due to the narrow linewidth of the laser. A pseudo-Voight fit is applied to the LIF excitation spectra on a pixel-by-pixel basis to measure the spectral position of the peak intensity for the two transition pairs and their amplitude. The spectral position of the peak intensity is used to derive a frequency shift, which is separated into its collisional and Doppler components using the axisymmetric nature of the flow field. The amplitude of the measured peaks is used for two-line rotational thermometry. Challenges for quantitative measurements using such an approach are discussed, including measuring the spatial variations in the energy distribution of the laser sheet at a 100 kHz repetition rate and uncertainty/variability in the step size during the fast frequency scan.

laser induced fluorescence↗

100 kHz High-Spectral-Resolution NO-PLIF Measurements for Compressible Flows

In the present work, we use a burst-mode laser and optical parametric oscillator system to perform high-spectral resolution NO-PLIF measurements of an underexpanded jet at a repetition-rate of 100 kHz, with the motivation of multi-parameter measurements of temperature, pressure, and velocity. The laser frequency of the 1064 nm seed laser for the burst-mode laser was scanned during the burst to cover two neighboring absorption line pairs near 226 nm. The peak PLIF signal intensity varies along the axial (z) direction of the underexpanded jet as the laser frequency is scanned, which we attribute to the collisional shift induced by the flow and only revealed due to the narrow linewidth of the laser. A pseudo-Voight fit is applied to the LIF excitation spectra on a pixel-by-pixel basis to measure the spectral position of the peak intensity for the two transition pairs and their amplitude. The spectral position of the peak intensity is used to derive a frequency shift, which is separated into its collisional and Doppler components using the axisymmetric nature of the flow field. The amplitude of the measured peaks is used for two-line rotational thermometry. Challenges for quantitative measurements using such an approach are discussed, including measuring the spatial variations in the energy distribution of the laser sheet at a 100 kHz repetition rate and uncertainty/variability in the step size during the fast frequency scan.

laser induced fluorescence↗

Development of a Multi-Gas Microsensor Array for the Exploration Portable Life Support System

The Portable Life Support System (PLSS) of the Exploration Extravehicular Mobility Unit (xEMU) requires sensors capable of measuring the major constituents of the gas stream. These major constituents include oxygen, carbon dioxide, and water vapor. The sensors must operate across a wide range of flow and pressure conditions and introduce very low pressure drop in the ventilation loop. The sensors must operate with low power and occupy a small volume. This paper reports the development of a compact, low power, multi-parameter astronaut life support sensor (M-PALSS). M-PALSS consists of an array of low-power chemical microsensors for oxygen, carbon dioxide, water vapor, and pressure. M-PALSS includes custom electronics to control the sensors and is packaged in a custom housing that meets the volume and shape requirements for service in the PLSS.

James Makel↗

Optimizing Retrieval Spaces of Bio-Optical Models for Remote Sensing of Ocean Color

We investigated the optimal number of independent parameters required to accurately represent spectral remote sensing reflectances (𝑅 rs ) by performing principal component analysis on quality controlled in situ and synthetic 𝑅 rs data. We found that retrieval algorithms should be able to retrieve no more than four free parameters from 𝑅 rs spectra for most ocean waters. In addition, we evaluated the performance of five different bio-optical models with different numbers of free parameters for the direct inversion of in-water inherent optical properties (IOPs) from in situ and synthetic 𝑅 rs data. The multi-parameter models showed similar performances regardless of the number of parameters. Considering the computational cost associated with larger parameter spaces, we recommend bio-optical models with three free parameters for the use of IOP or joint retrieval algorithms.

Ocean Color↗

Development of a Multi-Gas Microsensor Array for the Exploration Portable Life Support System

The Portable Life Support System (PLSS) of the Exploration Extravehicular Mobility Unit (xEMU) requires sensors capable of measuring the major constituents of the gas stream. These major constituents include oxygen, carbon dioxide, and water vapor. The sensors must operate across a wide range of flow and pressure conditions and introduce very low pressure drop in the ventilation loop. The sensors must operate with low power and occupy a small volume. This paper reports the development of a compact, low power, multi-parameter astronaut life support sensor (M-PALSS). M-PALSS consists of an array of low-power chemical microsensors for oxygen, carbon dioxide, water vapor, and pressure. M-PALSS includes custom electronics to control the sensors and is packaged in a custom housing that meets the volume and shape requirements for service in the PLSS.

James Makel↗