Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiplicative faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

System control module diagnostic Expert Assistant

The Orbiter EXperiments (OEX) Program was established by NASA's Office of Aeronautics and Space Technology (OAST) to accomplish the precise data collection necessary to support a complete and accurate assessment of Space Transportation System (STS) Orbiter performance during all phases of a mission. During a mission, data generated by the various experiments are conveyed to the OEX System Control Module (SCM) which arranges for and monitors storage of the data on the OEX tape recorder. The SCM Diagnostic Expert Assistant (DEA) is an expert system which provides on demand advice to technicians performing repairs of a malfunctioning SCM. The DEA is a self-contained, data-driven knowledge-based system written in the 'C' Language Production System (CLIPS) for a portable micro-computer of the IBM PC/XT class. The DEA reasons about SCM hardware faults at multiple levels; the most detailed layer of encoded knowledge of the SCM is a representation of individual components and layouts of the custom-designed component boards.

Flores, Luis M.↗

Autonomous Dynamically Self-Organizing and Self-Healing Distributed Hardware Architecture - the eDNA Concept

This paper presents the current state of the autonomous dynamically self-organizing and self-healing electronic DNA (eDNA) hardware architecture (patent pending). In its current prototype state, the eDNA architecture is capable of responding to multiple injected faults by autonomously reconfiguring itself to accommodate the fault and keep the application running. This paper will also disclose advanced features currently available in the simulation model only. These features are future work and will soon be implemented in hardware. Finally we will describe step-by-step how an application is implemented on the eDNA architecture.

self-healing hardware↗

Review and Analysis of Algorithmic Approaches Developed for Prognostics on CMAPSS Dataset

Benchmarking of prognostic algorithms has been challenging due to limited availability of common datasets suitable for prognostics. In an attempt to alleviate this problem several benchmarking datasets have been collected by NASA's prognostic center of excellence and made available to the Prognostics and Health Management (PHM) community to allow evaluation and comparison of prognostics algorithms. Among those datasets are five C-MAPSS datasets that have been extremely popular due to their unique characteristics making them suitable for prognostics. The C-MAPSS datasets pose several challenges that have been tackled by different methods in the PHM literature. In particular, management of high variability due to sensor noise, effects of operating conditions, and presence of multiple simultaneous fault modes are some factors that have great impact on the generalization capabilities of prognostics algorithms. More than 70 publications have used the C-MAPSS datasets for developing data-driven prognostic algorithms. The C-MAPSS datasets are also shown to be well-suited for development of new machine learning and pattern recognition tools for several key preprocessing steps such as feature extraction and selection, failure mode assessment, operating conditions assessment, health status estimation, uncertainty management, and prognostics performance evaluation. This paper summarizes a comprehensive literature review of publications using C-MAPSS datasets and provides guidelines and references to further usage of these datasets in a manner that allows clear and consistent comparison between different approaches.

Uncertainty↗

Quaternary slip rates and most recent surface rupture of the Bitterroot fault, western Montana

The Bitterroot fault is a ~100-km-long Quaternary active normal fault that bounds the eastern margin of the north–south-trending Bitterroot Mountains and accommodates extension near the Intermountain Seismic Belt. Here, new detailed mapping using high-resolution topographic data derived from light detection and ranging (lidar) along the southern Bitterroot Range documents multiple generations of fault scarps in Holocene–Pleistocene deposits with vertical off sets that increase in magnitude with age. Fault mapping indicates a complex fault geometry characterized by an en echelon pattern of discontinuous segments of 41–78° east-dipping normal faults that appear to cut the older Eocene detachment fault, and locally 70–88° west-dipping antithetic normal faults. 10 Be cosmogenic exposure dating provides in situ age control for 32 surface boulders (>1 m) sampled in glacial deposits. Near Como Dam, two Pinedale-age glacial moraine sequences yield peak age distributions of 15.0 ± 0.4 ka and 16.4 ± 0.6 ka as apparent exposure ages (e = 0), and 15.4 ± 0.4 ka and 16.8 ± 0.6 ka based on the maximum allowed boulder surface erosion rate (e = 2 mm/ka). Vertical separation of 3.5 ± 0.2 m across the ~16–17 ka glacial moraine off set by the Bitterroot fault scarp yields a fault slip rate of 0.2–0.3 mm/yr. Glacial Lake Missoula highstand shorelines, inset into the ~15 ka glacial moraine and vertically off set 4.6 ± 1.6 m by an antithetic strand of the Bitterroot fault, yield fault slip rates of 0.2–0.5 mm/yr that overlap with fault slip rates on the main strand near Lake Como (0.2–0.3 mm/yr). At the Ward Creek fan located ~15 km to the north of Lake Como, two glacial debris fan sequences yield peak age distributions of 16.6 ± 0.4 ka and 62.8 ± 1.7 ka (e = 0), and 17.0 ± 0.4 ka and 69.9 ± 2.2 ka (e = 2 mm/ka). Vertical separations of 2.4 ± 0.3 m and 4.5 ± 0.2 m on the ~17 ka and ~63–70 ka fan surfaces off set by the Bitterroot fault yield fault slip rates of 0.2–0.3 mm/yr and 0.1 mm/yr, respectively. Our results indicate broadly consistent fault slip rates for the main fault segments at Lake Como (0.2–0.3 mm/yr) and the Ward Creek fan (0.1–0.3 mm/yr) with an along-strike range of 0.1–0.3 mm/yr for the southern Bitterroot fault. Fault scaling relations and evidence of multiple late Quaternary fault surface ruptures suggest the Bitterroot fault could produce a Mw ~7.2 earthquake. Structural model constraints and our slip rate results indicate both high-angle or low-angle fault geometries are possible at depth. A seismogenic low-angle fault model could generate a larger earthquake of Mw >7.2. Earthquake history is unknown for the Bitterroot fault, but fault scarps in young glacial deposits demonstrate its seismogenic potential. Data from this study suggest seismic hazards from the Bitterroot fault may pose a high level of risk to the Missoula metropolitan area, the State’s second most populous region, and major infrastructures across the Missoula and Bitterroot Valleys.

58 GEOSCIENCES↗

Fault Management Techniques in Human Spaceflight Operations

This paper discusses human spaceflight fault management operations. Fault detection and response capabilities available in current US human spaceflight programs Space Shuttle and International Space Station are described while emphasizing system design impacts on operational techniques and constraints. Preflight and inflight processes along with products used to anticipate, mitigate and respond to failures are introduced. Examples of operational products used to support failure responses are presented. Possible improvements in the state of the art, as well as prioritization and success criteria for their implementation are proposed. This paper describes how the architecture of a command and control system impacts operations in areas such as the required fault response times, automated vs. manual fault responses, use of workarounds, etc. The architecture includes the use of redundancy at the system and software function level, software capabilities, use of intelligent or autonomous systems, number and severity of software defects, etc. This in turn drives which Caution and Warning (C&W) events should be annunciated, C&W event classification, operator display designs, crew training, flight control team training, and procedure development. Other factors impacting operations are the complexity of a system, skills needed to understand and operate a system, and the use of commonality vs. optimized solutions for software and responses. Fault detection, annunciation, safing responses, and recovery capabilities are explored using real examples to uncover underlying philosophies and constraints. These factors directly impact operations in that the crew and flight control team need to understand what happened, why it happened, what the system is doing, and what, if any, corrective actions they need to perform. If a fault results in multiple C&W events, or if several faults occur simultaneously, the root cause(s) of the fault(s), as well as their vehicle-wide impacts, must be determined in order to maintain situational awareness. This allows both automated and manual recovery operations to focus on the real cause of the fault(s). An appropriate balance must be struck between correcting the root cause failure and addressing the impacts of that fault on other vehicle components. Lastly, this paper presents a strategy for using lessons learned to improve the software, displays, and procedures in addition to determining what is a candidate for automation. Enabling technologies and techniques are identified to promote system evolution from one that requires manual fault responses to one that uses automation and autonomy where they are most effective. These considerations include the value in correcting software defects in a timely manner, automation of repetitive tasks, making time critical responses autonomous, etc. The paper recommends the appropriate use of intelligent systems to determine the root causes of faults and correctly identify separate unrelated faults.

O'Hagan, Brian↗

On the distribution of stacking faults at dissociated medium-angle grain boundaries: Crystallographic geometry and metastability

Grain boundaries in FCC metals with low stacking-fault energy can form in dissociated configurations of stacking faults. Perhaps the most studied example is 9R stacking at boundaries near Σ3{112}, where the distribution of stacking faults is related to the emission of Shockley partial dislocations. Here, we combine atomic-resolution electron microscopy, atomistic simulations, and dislocation theory to demonstrate that boundaries vicinal to Σ33a support the stabilization of dissociated 9R stacking within a narrow range of inclinations. This boundary is interesting since its misorientation (20.05°) lies in the medium-angle regime, just past the upper misorientation limit for low-angle boundaries, motivating questions for how best to describe it in terms of dislocations. Our HAADF-STEM observations of thin film bicrystals, supported by atomistic modeling, reveal that this inclination dependence arises from specific geometric constraints on the arrangement of Shockley partial dislocations at the interface. Quantification of stacking-fault distributions across multiple boundaries indicates that the density and spacing of faults closely follow the ideal 9R motif, with subtle variations reflecting the complex energy landscape of these boundaries. Through energetic analysis, we establish the presence of competing metastable states enabled by variations in stacking sequences, emphasizing the significant role of crystallographic geometry. We generalize our analysis as a function of misorientation, showing how 9R at the Σ33a boundary is related to previous observations and calculations of HCP at a 29.7° boundary. This study provides a crystallographically grounded framework connecting dislocation structures, stacking-fault distributions, and metastability at grain boundaries in FCC metals.

Atomistic modeling↗

3D Coded SUMMA: Communication-Efficient and Robust Parallel Matrix Multiplication

In this paper, we propose a novel fault-tolerant parallel matrix multiplication algorithm called 3D Coded SUMMA that achieves higher failure-tolerance than replication-based schemes for the same amount of redundancy. This work bridges the gap between recent developments in coded computing and fault-tolerance in high-performance computing (HPC). The core idea of coded computing is the same as algorithm-based fault-tolerance (ABFT), which is weaving redundancy in the computation using error-correcting codes. In particular, we show that MatDot codes, an innovative code construction for parallel matrix multiplications, can be integrated into three-dimensional SUMMA (Scalable Universal Matrix Multiplication Algorithm [30]) in a communication-avoiding manner. To tolerate any two node failures, the proposed 3D Coded SUMMA requires ~50% less redundancy than replication, while the overhead in execution time is only about 5–10%.

97 MATHEMATICS AND COMPUTING↗

Adaptive Fault Detection Based on Neural Networks and Multiple Sampling Points for Distribution Networks and Microgrids

Smart networks such as microgrid (MG) and active distribution networks (ADN) have been recently playing an important role in power system operation. The design and implementation of appropriate protection systems for such networks must be addressed, which imposes new technical challenges. This paper presents the implementation and validation aspects of an adaptive fault detection strategy based on neural networks (NNs) and multiple sampling points for ADN and MG. The solution is implemented on an edge device. Artificial NNs are used to derive a data-driven model that uses only local measurements to detect fault states of the network without the need for communication infrastructure. Multiple sampling points are used to derive a data-driven model, which allows the generalization considering the implementation in physical systems. The adaptive fault detector model is implemented on a Jetson Nano system, which is a single-board computer (SBC) with a small Graphic Processing Unit (GPU) intended to run machine learning loads at the edge. The proposed method is tested in a physical, real-life, low-voltage network located at Universidad del Norte, Colombia. This testing network is based on the IEEE-13 Node Test Feeder scaled down to 220 V. The validation in a simulation environment shows the accuracy and dependability above 99.6%, while the real-time tests show the accuracy and dependability of 95.5% and 100%, respectively. Without hard-to-derive parameters, the easy-to-implement embedded model highlights the potential for real-life applications.

42 ENGINEERING↗

Investigation of Multiple Data Streams for Gearbox Bearing Fault Prediction Through Machine-Learning Models

Operations and maintenance (O&M) cost of wind plant accounts up to 30% of total energy cost, which can be reduced through continuous monitoring and successfully detecting incipient wind turbine failures. To accomplish this, condition monitoring and predictive maintenance systems are being implemented in wind industry to support O&M decision making. A wide range of approaches for condition monitoring and fault prediction have been developed. These approaches generally use historical data of wind turbines collected by Supervisory Control and Data Acquisition (SCADA) system to identify patterns that lead to failure. These SCADA data show the overall condition of a wind turbine and can be leveraged to detect when the turbine's performance is degrading and to identify if a fault is developing. However, it becomes challenging to predict the failure of a specific wind turbine gearbox bearing, because the SCADA data are often not directly linked to the component. To bridge the gap, we have investigated features calculated from SCADA data using physics-based models and the gearbox design over the years. The damaged metric we used in the physics domain is frictional energy. Combining these physics domain variables with SCADA data as inputs to various machine learning models for gearbox bearing fault prediction, we have demonstrated the benefits of leveraging both physics and data domain models. It was an attempt to improve frictional-energy-based damage metric by adding data domain inputs, as we had learned that the frictional-energy-based damage metric alone is not sufficient to single out failed bearings from healthy. As condition monitoring data (either vibration or oil debris data) has become available at more and more wind plants, we would like to evaluate whether by adding the condition monitoring data can help further improve the performance of frictional-energy-based damage metric for gearbox bearing fault prediction. Both cases by modeling through various machine learning algorithms are discussed in this study along with some observations.

fault prediction↗

Reports on block rotations, fault domains and crustal deformation

Studies of block rotations, fault domains and crustal deformation in the western United States, Israel, and China are discussed. Topics include a three-dimensional model of crustal fracture by distributed fault sets, distributed deformation and block rotation in 3D, stress field rotation, and multiple strike slip fault sets.

Nur, Amos↗

A Boundary Element Model for Assessing Large‐Scale Pressurization in Faulted Geological Storage Systems

Assessing large-scale pressurization at the regional scale—a possible outcome of large subsurface storage applications such as wastewater injection and geological carbon sequestration—presents significant computational challenges. These challenges are particularly pronounced when accounting for complex geologic structures with multiple reservoir and caprock layers, fault zones, and wells. This study introduces a computationally efficient model that integrates single-phase semi-analytical solutions with a boundary element (BE) approach. The model simulates pressure propagation in multilayered 3D systems, including vertical faults, caprock, basement, and confining units. We apply this new model to a representative scenario involving CO 2 injection near a partially sealing fault with verification against an independent two-phase flow model. Results demonstrate that our model accurately captures far-field pressure responses and that, outside the CO 2 plume zone, pressure predictions from single-phase and two-phase models are nearly identical. This supports the use of single-phase models like ours for efficient estimation of far-field pressure changes. Additionally, we demonstrate its effectiveness at a large scale, incorporating multiple wells and faults. With its ability to represent multiple wells, fault zones, and geological heterogeneity, our model is well suited for assessments of basin-scale pressurization. Its computational efficiency also makes it a promising tool for integration with optimization frameworks aimed at designing and managing injection strategies in faulted storage systems.

Cihan, A. [Lawrence Berkeley National Laboratory (↗

Flag Gadgets Based on Classical Codes

Fault-tolerant syndrome extraction is a key ingredient in implementing fault-tolerant quantum computation. While conventional methods use a number of extra qubits that are linear in the weight of the syndrome, several improvements have been introduced using flag gadgets. In this work, we develop a framework to design flag gadgets using classical codes. Using this framework, we show how to perform fault-tolerant syndrome extraction for any stabilizer code with arbitrary distance using exponentially fewer qubits than conventional methods when qubit measurement and reset are relatively slow compared to a round of error correction. In particular, our method requires only ( 2 t + 1 ) t ⌈ log 2 ( w ) ⌉ flag qubits to fault-tolerantly measure a weight- w stabilizer. We further take advantage of the saving provided by our construction to fault-tolerantly measure multiple stabilizers using a single gadget and show that it maintains the same exponential advantage when it is used to fault-tolerantly extract the syndromes of quantum low-density parity-check codes. Using the developed framework, we perform computer-assisted search to find several small examples where our constructions reduce the number of qubits required. These small examples may be relevant to near-term experiments on small-scale quantum computers. Published by the American Physical Society 2024

Anker, Benjamin↗

De-Energized Line Testing Interface (DELTI) Report

To guarantee the safety of power system operations, it is crucial to understand a de-energized power line’s status before restoring power. It is hypothesized that the Grid Resonance Probe (GRP) and De-Energized Line Testing Interface (DELTI) can be utilized to identify a faulted distribution line. Therefore, the project team is targeting development of a methodology to identify faulted distribution lines by using the DELTI system. In this R&D task, two field tests on Plum Island have been conducted, including DELTI tests with multiple configurations and fault scenarios. This report provides the analysis results of distribution line fault identification from the two field tests. In the remainder of this report, Section 1 is the introduction of the DELTI system, Section 2 provides the analyses of the two field tests in June and October of 2021, respectively, Section 3 discusses the existing line fault detection devices on market and how they compare to DELTI and Section 4 includes the lessons learned and recommendations for future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EV-EVSE Fault Study: An Analysis of Thermal Events Caused by Electrical Faults during DC Charging

This report outlines multiple avenues of analysis of electrical faults associated with electric vehicles (EVs) during charging, focusing specifically on the interactions between EVs and EV supply equipment (EVSE). Key concerns include the identification and mitigation of overtemperature events that can result in fires, which are commonly initiated by localized heating of connectors, wiring, or high-impedance fault current paths.

42 - ENGINEERING↗

Multiple Holocene Earthquakes on the Gales Creek Fault, Northwest Oregon Fore-Arc

Several potentially hazardous northwest–striking faults in and around the Portland basin, within the fore-arc of Cascadia, are classified as Quaternary active by the U.S. Geological Survey, but little is known about their Holocene activity. We present new earthquake–timing constraints on the Gales Creek fault (GCF), a 73 km long, northwest–trending fault with youthful geomorphic expression located about 35 km west of Portland. We excavated a paleoseismic trench across the GCF in the populated northern Willamette Valley and document three surface-rupturing earthquakes from stratigraphic and structural relationships. Radiocarbon samples from offset stratigraphy constrain these earthquakes to have occurred ~1000, ~4200, and ~8800 calibrated years before the present. The penultimate earthquake back–tilted a buried soil into the hillslope creating accommodation space that was infilled by a colluvial deposit. The most recent earthquake faulted and formed a fissure within the penultimate colluvial deposit. Our results suggest that the GCF has a recurrence interval of ~4000 yr, and if the full 73 km length were to rupture, it would result in an M w 7.1–7.4 earthquake, providing a significant seismic hazard for the greater Portland metropolitan area.

15 GEOTHERMAL ENERGY↗

Investigation of advanced fault insertion and simulator methods

The cooperative agreement partly supported research leading to the open-literature publication cited. Additional efforts under the agreement included research into fault modeling of semiconductor devices. Results of this research are presented in this report which is summarized in the following paragraphs. As a result of the cited research, it appears that semiconductor failure mechanism data is abundant but of little use in developing pin-level device models. Failure mode data on the other hand does exist but is too sparse to be of any statistical use in developing fault models. What is significant in the failure mode data is that, unlike classical logic, MSI and LSI devices do exhibit more than 'stuck-at' and open/short failure modes. Specifically they are dominated by parametric failures and functional anomalies that can include intermittent faults and multiple-pin failures. The report discusses methods of developing composite pin-level models based on extrapolation of semiconductor device failure mechanisms, failure modes, results of temperature stress testing and functional modeling. Limitations of this model particularly with regard to determination of fault detection coverage and latency time measurement are discussed. Indicated research directions are presented.

Dunn, W. R.↗

Cable Tester Box

Cables are very important electrical devices that carry power and signals across multiple instruments. Any fault in a cable can easily result in a catastrophic outcome. Therefore, verifying that all cables are built to spec is a very important part of Electrical Integration Procedures. Currently, there are two methods used in lab for verifying cable connectivity. (1) Using a Break-Out Box and an ohmmeter this method is time-consuming but effective for custom cables and (2) Commercial Automated Cable Tester Boxes this method is fast, but to test custom cables often requires pre-programmed configuration files, and cables used on spacecraft are often uniquely designed for specific purposes. The idea is to develop a semi-automatic continuity tester that reduces human effort in cable testing, speeds up the electrical integration process, and ensures system safety. The JPL-Cable Tester Box is developed to check every single possible electrical connection in a cable in parallel. This system indicates connectivity through LED (light emitting diode) circuits. Users can choose to test any pin/shell (test node) with a single push of a button, and any other nodes that are shorted to the test node, even if they are in the same connector, will light up with the test node. The JPL-Cable Tester Boxes offers the following advantages: 1. Easy to use: The architecture is simple enough that it only takes 5 minutes for anyone to learn how operate the Cable Tester Box. No pre-programming and calibration are required, since this box only checks continuity. 2. Fast: The cable tester box checks all the possible electrical connections in parallel at a push of a button. If a cable normally takes half an hour to test, using the Cable Tester Box will improve the speed to as little as 60 seconds to complete. 3. Versatile: Multiple cable tester boxes can be used together. As long as all the boxes share the same electrical potential, any number of connectors can be tested together.

Lee, Jason H.↗

Multi-module-based CVAE to predict HVCM faults in the SNS accelerator

We present a multi-module framework based on Conditional Variational Autoencoder (CVAE) to detect anomalies in the power signals coming from multiple High Voltage Converter Modulators (HVCMs). We condition the model with the specific modulator type to capture different representations of the $\mathcal{normal}$ waveforms and to improve the sensitivity of the model to identify a specific type of fault when we have limited samples for a given module type. We studied several Artificial Neural Network (ANN) architectures for our CVAE model and evaluated the model performance by looking at their loss landscape for stability and generalization. Our results for the Spallation Neutron Source (SNS) experimental data show that the trained model generalizes well to detecting multiple fault types for several HVCM module types. The results of this study can be used to improve the HVCM reliability and overall SNS uptime.

43 PARTICLE ACCELERATORS↗