Search NASA⌕ Search

SEARCH · Search NASA

Results for “nanometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Silicon Lightweight Mirrors (SLMS) for Ultraviolet and Extreme Ultraviolet Imaging Mirrors

Subtopic 01-S1.06 requires mirrors with a diameter of 0.5-2.4 meters, areal density less than 20 kg/sq m, a figure specification of 0.02-0.005 waves root mean square (rms) at 633 nanometers, a surface roughness 0.5-1 nanometers rms, and a midfrequency error of 1.0-2.5 nanometers rms for use in the infrared (IR) to extreme ultra violet (EUV) waveband. Schafer's Phase II objective is to use Silicon Lightweight Mirrors (SLMS), a novel, all-silicon, foam-core, lightweight mirror technology, to build three imaging mirrors for the Next Generation Space Telescope Near Infrared Camera (NIRCam) Engineering Test Unit: M0 (a flat), M2 (a concave sphere) and M3R (an oblate spheroid). The surface figure error specification for the NIRCam imaging mirrors is 8 nanometers rms (0.013 waves rms at 633 nanometers), equivalent to that required for ultraviolet (UV) and EUV mirrors, and this figure must be maintained at the 35 K operational temperature of NGST. The surface roughness required is 30 A rms since NIRCam operates in the visible to infrared (VIS/IR) (0.65-5 microns). We will produce mounts for mirrors M2 and M3R using the complementary thermally matched C/SiC material demonstrated by Schafer under another NASA SBIR, NAS8-98137.

Goodman, W. A.↗

Ground and Airborne Methane Measurements using Optical Parametric Amplifiers

We report on an initial airborne demonstration of atmospheric methane column measurements at 1.65 micrometers using a widely tunable, seeded optical parametric amplifier (OPA) lidar and a photon counting detector. Methane is an important greenhouse gas and accurate knowledge of its sources and sinks is needed for climate modeling. Our lidar system uses 20 pulses at increasing wavelengths and integrated path differential absorption (IPDA) to map a methane line at 1650.9 nanometers. The wavelengths are generated by using a Nd:YAG pump laser at 1064.5 nanometers and distributed feedback diode laser at 1650.9 nanometers and a periodically-poled lithium niobate (PPLN) crystal. The pulse width was 3 nanoseconds and the pulse repetition rate was 6.28 KHz. The outgoing energy was approximately 13 microJoules/pulse. A commercial 20 nanometer diameter fiber-coupled telescope with a photon counting detector operated in analog mode with a 0.8 nanometer bandpass filter was used as the lidar receiver. The lidar system was integrated on NASA's DC-8 flying laboratory, based at Dryden Airborne operations Facility (DAOF) in Palmdale CA. Three flights were performed in the central valley of California. Each flight lasted about 2.5 hours and it consisted of several flight segments at constant altitudes at approximately 3, 4.5, 6, 7.6, 9.1, 10.6 km (l0, 15, 20, 25, 30, 35 kft). An in-situ cavity ring down spectrometer made by Picarro Inc. was flown along with the lidar instrument provided us with the "truth" i.e. the local CH4, CO2 and H2O concentrations at the constant flight altitude segments. Using the aircraft's altitude, GPS, and meteorological data we calculated the theoretical differential optical depth of the methane absorption at increasing altitudes. Our results showed good agreement between the experimentally derived optical depth measurements from the lidar instrument and theoretical calculations as the flight altitude was increased from 3 to 10.6 kilometers, assuming a constant methane mixing ratio of 1.8 parts per million. The in-situ spectrometer did not show any significant deviations from the ambient concentrations. Further analysis using meteorological data from the Global Modeling and Assimilation Office (http://gmao.gsfc.nasa.gov/) to derive the theoretical optical depth also showed good agreement with the experimentally derived values. The OPA lidar system with slight modifications has also been used to measure CO2, water vapor, and CO in the near and mid-infrared spectral regions on the ground.

Riris, Haris↗

Photosynthetic Efficiency of Northern Forest Ecosystems Using a MODIS-Derived Photochemical Reflectance Index (PRI)

This study evaluates a direct remote sensing approach from space for the determination of ecosystem photosynthetic light use efficiency (LUE), through measurement of vegetation reflectance changes expressed with the Photochemical Reflectance Index (PRI). The PRI is a normalized difference index based on spectral changes at a physiologically active wavelength (approximately 531 nanometers) as compared to a reference waveband, and is only available from a very few satellites. These include the two Moderate-Resolution Imaging Spectroradiometers (MODIS) on the Aqua and Terra satellites each of which have a narrow (10-nanometer) ocean band centered at 531 nanometers. We examined several PRI variations computed with candidate reference bands, since MODIS lacks the traditional 570-nanometer reference band. The PRI computed using MODIS land band 1 (620-670 nanometers) gave the best performance for daily LUE estimation. Through rigorous statistical analyses over a large image collection (n equals 420), the success of relating in situ daily tower-derived LUE to MODIS observations for northern forests was strongly influenced by satellite viewing geometry. LUE was calculated from CO2 fluxes (moles per moles of carbon absorbed quanta) measured at instrumented Canadian Carbon Program flux towers in four Canadian forests: a mature fir site in British Columbia, mature aspen and black spruce sites in Saskatchewan, and a mixed deciduous/coniferous forest site in Ontario. All aspects of the viewing geometry had significant effects on the MODIS-PRI, including the view zenith angle (VZA), the view azimuth angle, and the displacement of the view azimuth relative to the solar principal plane, in addition to illumination related variables.Nevertheless, we show that forward scatter sector views (VZA, 16 degrees-45 degrees) provided the strongest relationships to daily LUE, especially those collected in the early afternoon by Aqua (r squared = 0.83, RMSE (root mean square error) equals 0.003 moles per moles of carbon absorbed quanta). Nadir (VZA, 0 degrees plus or minus 15 degrees) and backscatter views (VZA, −16 degrees to −45 degrees) had lower performance in estimating LUE (nadir: r squared approximately equal to 0.62-0.67; backscatter: r squared approximately equal to 0.54-0.59) and similar estimation error (RMSE equals 0.004-0.005).When directional effects were not considered, only a moderately successful MODIS-PRI vs. LUE relationship (r squared equals 0.34, RMSE equals 0.007) was obtained in the full dataset (all views & sites, both satellites), but site-specific relationships were able to discriminate between coniferous and deciduous forests. Overall, MODIS-PRI values from Terra (late morning) were higher than those from Aqua (early afternoon), before/after the onset of diurnal stress responses expressed spectrally. Therefore, we identified ninety-two Terra-Aqua "same day" pairs, for which the sum of Terra morning and Aqua afternoon MODIS-PRI values (PRI (sub sum) using all available directional observations was linearly correlated with daily tower LUE (r squared equals 0.622, RMSE equals 0.013) and independent of site differences or meteorological information. Our study highlights the value of off-nadir directional reflectance observations, and the value of pairing morning and afternoon satellite observations to monitor stress responses that inhibit carbon uptake in Canadian forest ecosystems. In addition, we show that MODIS-PRI values, when derived from either: (i) forward views only, or (ii) Terra/Aqua same day (any view) combined observations, provided more accurate estimates of tower-measured daily LUE than those derived from either nadir or backscatter views or those calculated by the widely used semi-operational MODIS GPP model (MOD17) which is based on a theoretical maximum LUE and environmental data. Consequently, we demonstrate the importance of diurnal as well as off-nadir satellite observations for detecting vegetation physiological processes.

Middleton, E. M.↗

Analysis of high altitude remotely sensed data collected in the Nantucket Shoals experiment 4-15 May, 1981

High altitude ocean color scanner ratios of band 2 (456 to 476 nanometers) to band 4 (539 to 559 nanometers) and band 1 (418 to 438 nanometers) to band 3 (498 to 518 nanometers) had high correlation coefficient values (-0.928 and 0.891 respectively) with seven boat sampled chlorophyll a measurements. The range of chlorophyll a concentrations was small (1.7-2.58 mg/cu m.). Each ratio was used to calculate chlorophyll a values for the center pixel of each scan line on flight lines 5 and 6. The two ratios produced dissimilar chlorophyll a trends. Due to the high noise level in the scanner data, no reliable synoptic chlorophyll a map could be generated with either ratio algorithm.

Ohlhorst, C. W.↗

Optical pathlength control experiment on JPL phase B testbed

An experimental implementation of a nanometer level optical pathlength control for large baseline space interferometry is presented. The pathlength compensation system is installed on a large flexible experimental truss, thus structural motions play a dominant role in the control system design. The associated control structure interaction problem is addressed to maintain the optical pathlength within the prescribed variation of 10-15 nanometer rms. By a successful blend of a structural control for damping augmentation and a direct pathlength control for the pathlength compensation, the optical pathlength variation has been maintained with 6 nanometer rms under the laboratory ambient disturbance and within 9 nanometer rms under a severe forced resonant disturbance.

Rahman, Zahidul H.↗

A Synthesis of Fluid Dynamics and Quantum Chemistry for the Design of Nanoelectronics

In 1959, during a famous lecture entitled "There's Plenty of Room at the Bottom", Richard Feynman focused on the startling technical possibilities that would exist at the limit of miniaturization, that being atomically precise devices with dimensions in the nanometer range. A nanometer is both a convenient unit of length for medium to large sized molecules, and the root of the name of the new interdisciplinary field of "nanotechnology". Essentially, "nanoelectronics" denotes the goal of shrinking electronic devices, such as diodes and transistors, as well as integrated circuits of such devices that can perform logical operations, down to dimensions in the range of 100 nanometers. The thirty-year hiatus in the development of nanotechnology can figuratively be seen as a period of waiting for the bottom-up and atomically precise construction skills of synthetic chemistry to meet the top-down reductionist aspirations of device physics. The sub-nanometer domain of nineteenth-century classical chemistry has steadily grown, and state-of-the-art supramolecular chemistry can achieve atomic precision in non-repeating molecular assemblies of the size desired for nanotechnology. For nanoelectronics in particular, a basic understanding of the electron transport properties of molecules must also be developed. Quantum chemistry provides powerful computational methods that can accurately predict the properties of small to medium sized molecules on a desktop workstation, and those of large molecules if one has access to a supercomputer. Of the many properties of a molecule that quantum chemistry routinely predicts, the ability to carry a current is one that had not even been considered until recently. "Currently", there is a controversy over just how to define this key property. Reminiscent of the situation in high-Tc superconductivity, much of the difficulty arises from the different models that are used to simplify the complex electronic structure of real materials. A model-independent approach has been proposed, that sacrifices the plentiful molecular orbitals and Bloch functions of conventional approaches, for a single three-dimensional observable quantity, the electron momentum density Pi(sub rho). This quantity is simply the probability of any electron having momentum rho, multiplied by the total number of electrons in the system (the position of the electron is uncertain). We have explored the utility of this new approach in providing a fundamental understanding of the electron transport properties of molecules that have provi been nominated as candidates for components in the design of nanoelectronics; phenylene-ethynylene oligomers. Some of the molecular systems that have been studied are sketched below.

MacDougall, Preston J.↗

AFM Studies of Lunar Soils and Application to the Mars 2001 Mission

The upcoming Mars 01 mission will carry an Atomic Force Microscope (AFM) as part of the Mars Environmental Compatibility Assessment (MECA) instrument. By operating in a tapping mode, the AFM is capable of sub-nanometer resolution in three dimensions and can distinguish between substances of different compositions by employing phase contrast imaging. To prepare for the Mars 01 mission, we are testing the AFM on a lunar soil to determine its ability to define particle shapes and sizes and grain-surface textures. The test materials are from the Apollo 17 soil 79221, which is a mixture of agglutinates, impact and volcanic beads, and mare and highland rock and mineral fragments. The majority of the lunar soil particles are less than 100 microns in size, comparable to the sizes estimated for martian dust. We have used the AFM to examine several different soil particles at various resolutions. The instrument has demonstrated the ability to identify parallel ridges characteristic of twinning on a 150 micron plagioclase feldspar particle. Extremely small (10-100 nanometer) adhering particles are visible on the surface of the feldspar grain, and they appear elongate with smooth surfaces. Phase contrast imaging of the nanometer particles shows several compositions to be present. When the AFM was applied to a 100 micron glass spherule, it was possible to define an extremely smooth surface; this is in clear contrast to results from a basalt fragment which exhibited a rough surface texture. Also visible on the surface of the glass spherule were chains of 100 nanometer and smaller impact melt droplets. For the '01 Mars mission, the AFM is intended to define the size and shape distributions of soil particles, in combination with the NMCA optical microscope system and images from the Robot Arm Camera (RAC). These three data sets will provide a means of assessing potentially hazardous soil and dust properties. The study that we have conducted on the lunar soils now suggests that the NMCA experiment will be able to define grain transport and weathering processes. For example, it should be possible to determine if Martian grains have been subjected to aeolian or water transport, volcanic activity, impact melting processes, in-situ weathering, and a host of other processes. Additionally, textural maturity could be assessed (via freshness and form of fracture patterns and grain shapes). Thus, the AFM has the potential to shed new light on Martian surface processes by adding the submicroscopic dimension to planetary investigations.

Weitz, C. M.↗

Ultra-Light Precision Membrane Optics

SRS Technologies and NASA Marshall Space Flight Center have conducted a research effort to explore the possibility of developing ultra-lightweight membrane optics for future imaging applications. High precision optical flats and spherical mirrors were produced under this research effort. The thin film mirrors were manufactured using surface replication casting of CPI(Trademark), a polyimide material developed specifically for UV hardness and thermal stability. In the course of this program, numerous polyimide films were cast with surface finishes better than 1.5 nanometers rms and thickness variation of less than 63 nanometers. Precision membrane optical flats were manufactured demonstrating better than 1/13 wave figure error when measured at 633 nanometers. The aerial density of these films is 0.037 kilograms per square meter. Several 0.5-meter spherical mirrors were also manufactured. These mirrors had excellent surface finish (1.5 nanometers rms) and figure error on the order of tens of microns. This places their figure error within the demonstrated correctability of advanced wavefront correction technologies such as real time holography.

Moore, Jim↗

Ferroelectric Material Application: Modeling Ferroelectric Field Effect Transistor Characteristics from Micro to Nano

All present ferroelectric transistors have been made on the micrometer scale. Existing models of these devices do not take into account effects of nanoscale ferroelectric transistors. Understanding the characteristics of these nanoscale devices is important in developing a strategy for building and using future devices. This paper takes an existing microscale ferroelectric field effect transistor (FFET) model and adds effects that become important at a nanoscale level, including electron velocity saturation and direct tunneling. The new model analyzed FFETs ranging in length from 40,000 nanometers to 4 nanometers and ferroelectric thickness form 200 nanometers to 1 nanometer. The results show that FFETs can operate on the nanoscale but have some undesirable characteristics at very small dimensions.

MacLeod, Todd, C.↗

Radiation-Hardened Electronics for Advanced Communications Systems

Novel approach enables high-speed special-purpose processors Advanced reconfigurable and reprogrammable communication systems will require sub-130-nanometer electronics. Legacy single event upset (SEU) radiation-tolerant circuits are ineffective at speeds greater than 125 megahertz. In Phase I of this project, ICs, LLC, demonstrated new base-level logic circuits that provide SEU immunity for sub-130-nanometer high-speed circuits. In Phase II, the company developed an innovative self-restoring logic (SRL) circuit and a system approach that provides high-speed, SEU-tolerant solutions that are effective for sub-130-nanometer electronics scalable to at least 22-nanometer processes. The SRL system can be used in the design of NASA's next-generation special-purpose processors, especially reconfigurable communication processors.

Whitaker, Sterling↗

Self-Raman Nd:YVO4 Laser and Electro-Optic Technology for Space-Based Sodium Lidar Instrument

We are developing a laser and electro-optic technology to remotely measure Sodium (Na) by adapting existing lidar technology with space flight heritage. The developed instrumentation will serve as the core for the planning of an Heliophysics mission targeted to study the composition and dynamics of Earth's mesosphere based on a spaceborne lidar that will measure the mesospheric Na layer. We present performance results from our diode-pumped tunable Q-switched self-Raman c-cut Nd:YVO4 laser with intra-cavity frequency doubling that produces multi-watt 589 nm wavelength output. The c-cut Nd:YVO4 laser has a fundamental wavelength that is tunable from 1063-1067 nanometers. A CW (Continuous Wave) External Cavity diode laser is used as a injection seeder to provide single-frequency grating tunable output around 1066 nanometers. The injection-seeded self-Raman shifted Nd:VO4 laser is tuned across the sodium vapor D2 line at 589 nanometers. We will review technologies that provide strong leverage for the sodium lidar laser system with strong heritage from the Ice Cloud and Land Elevation Satellite-2 (ICESat-2) Advanced Topographic Laser Altimeter System (ATLAS). These include a space-qualified frequency-doubled 9 watts-at-532-nanometer wavelength Nd:YVO4 laser, a tandem interference filter temperature-stabilized fused-silica-etalon receiver and high-bandwidth photon-counting detectors.

Krainak, Michael A.↗

Self-Raman Nd:YVO4 Laser and Electro-Optic Technology for Space-Based Sodium Lidar Instrument

We are developing a laser and electro-optic technology to remotely measure Sodium (Na) by adapting existing lidar technology with space flight heritage. The developed instrumentation will serve as the core for the planning of an Heliophysics mission targeted to study the composition and dynamics of Earth's mesosphere based on a spaceborne lidar that will measure the mesospheric Na layer. We present performance results from our diode-pumped tunable Q-switched self-Raman c-cut Nd:YVO4 laser with intra-cavity frequency doubling that produces multi-watt 589 nm wavelength output. The c-cut Nd:YVO4 laser has a fundamental wavelength that is tunable from 1063-1067 nanometers. A CW (Continuous Wave) External Cavity diode laser is used as a injection seeder to provide single-frequency grating tunable output around 1066 nanometers. The injection-seeded self-Raman shifted Nd:VO4 laser is tuned across the sodium vapor D2 line at 589 nanometers. We will review technologies that provide strong leverage for the sodium lidar laser system with strong heritage from the Ice Cloud and Land Elevation Satellite-2 (ICESat-2) Advanced Topographic Laser Altimeter System (ATLAS). These include a space-qualified frequency-doubled 9 watts-at-532-nanometer wavelength Nd:YVO4 laser, a tandem interference filter temperature-stabilized fused-silica-etalon receiver and high-bandwidth photon-counting detectors.

Krainak, Michael A.↗

Relationship between vegetation reflectance spectra and soil geochemistry: New data from Catheart Mountain, Maine

Spectral reflectance curves for red spruce and balsam fir in the 350- to 1100-nanometer region showed differences between specimens growing over and away from a concealed copper deposit at Catheart Mountain, Maine. A sample group of 15 anomalous spruce, 9 background spruce, 10 anomalous fir, and 10 background fir was studied. Measurements of copper and molybdenum contents in the supporting soil were used to categorize the trees as anomalous or background. Analyses using parametric and nonparametric statistical tests were performed to establish whether significant differences existed between the anomalous and background groups. At the 95% confidence level, significant differences were found to exist for both species, generally in the chlorophyll band centered at about 550 nanometers and in the region from 700 to 900 nanometers.

Canney, F. C.↗

Mycological studies housed in the Apollo 16 microbial ecology evaluation device

Survival, death, and phenotype count have yielded variation in the number of fungi recovered from the controls and the flight exposed cuvettes during preliminary analysis of postflight first phase data. Also the preliminary analysis was indicative that fungi exposed to specific space flight conditions demonstrated variable survival rates and phenotype counts. Specific space flight conditions included full light space exposure for Chaetomium globosum, exposure at 300- and 254-nanometer wavelengths for Rhodotorula rubra, full light and 280-nanometer wavelength exposure for Trichophyton terrestre, and 254-nanometer wavelength exposure for Saccharomyces cerevisiae. In general, phenotype counts for flight cuvettes and survival rates for control cuvettes were higher compared with the remaining cuvettes.

Volz, P. A.↗

Spectral properties of gaseous uranium hexafluoride at high temperature

A study to determine relative spectral emission and spectral absorption data for UF6-argon mixtures at elevated temperatures is discussed. These spectral data are required to assist in the theoretical analysis of radiation transport in the nuclear fuel-buffer gas region of a plasma core reactor. Relative emission measurements were made for UF6-argon mixtures over a range of temperatures from 650 to 1900 K and in the wavelength range from 600 to 5000 nanometers. All emission results were determined for a total pressure of 1.0 atm. Uranium hexafluoride partial pressures varied from about 3.5 to 12.7 mm Hg. Absorption measurements were attempted at 600, 625, 650 and 675 nanometers for a temperature of 1000 K. The uranium partial pressure for these determinations was 25 mm Hg. The results exhibit appreciable emission for hot UF6-argon mixtures at wavelengths between 600 and 1800 nanometers and no measurable absorption. The equipment used to evaluate the spectral properties of the UF6-argon mixtures included a plasma torch-optical plenum assembly, the monochromator, and the UF6 transfer system. Each is described.

Krascella, N. L.↗

The 4-meter lunar engineering telescope

The 16-meter diffraction limited lunar telescope incorporates a primary mirror with 312 one-meter segments; 3 nanometer active optics surface control with laser metrology and hexapod positioners; a space frame structure with one-millimeter stability; and a hexapod mount for pointing. The design data needed to limit risk in this development can be obtained by building a smaller engineering telescope on the moon with all of the features of the 16-meter design. This paper presents a 4.33-meter engineering telescope concept developed by the Summer 1990 Student Program of the NASA/JHU Space Grant Consortium Lunar Telescope Project. The primary mirror, made up of 18 one-meter hexagonal segments, is sized to provide interesting science as well as engineering data. The optics are configured as a Ritchey-Chretien with a coude relay to the focal plane beneath the surface. The optical path is continuously monitored with 3-nanometer precision interferometrically. An active optics processor and piezoelectric actuators operate to maintain the end-to-end optical configuration established by wave front sensing using a guide star. The mirror segments, consisting of a one-centimeter thick faceplate on 30-cm deep ribs, maintain the surface figure to a few nanometers under lunar gravity and thermal environment.

Peacock, Keith↗

High Resolution Transmission Electron Microscopy (HRTEM) of nanophase ferric oxides

Iron oxide minerals are the prime candidates for Fe(III) signatures in remotely sensed Martian surface spectra. Magnetic, Mossbauer, and reflectance spectroscopy have been carried out in the laboratory in order to understand the mineralogical nature of Martian analog ferric oxide minerals of submicron or nanometer size range. Out of the iron oxide minerals studied, nanometer sized ferric oxides are promising candidates for possible Martian spectral analogs. 'Nanophase ferric oxide (np-Ox)' is a generic term for ferric oxide/oxihydroxide particles having nanoscale (less than 10 nm) particle dimensions. Ferrihydrite, superparamagnetic particles of hematite, maghemite and goethite, and nanometer sized particles of inherently paramagnetic lepidocrocite are all examples of nanophase ferric oxides. np-Ox particles in general do not give X-ray diffraction (XRD) patterns with well defined peaks and would often be classified as X-ray amorphous. Therefore, different np-Oxs preparations should be characterized using a more sensitive technique e.g., high resolution transmission electron microscopy (HRTEM). The purpose of this study is to report the particle size, morphology and crystalline order, of five np-Ox samples by HRTEM imaging and electron diffraction (ED).

Golden, D. C.↗

Nanoelectronics: Opportunities for future space applications

Further improvements in the performance of integrated electronics will eventually halt due to practical fundamental limits on our ability to downsize transistors and interconnect wiring. Avoiding these limits requires a revolutionary approach to switching device technology and computing architecture. Nanoelectronics, the technology of exploiting physics on the nanometer scale for computation and communication, attempts to avoid conventional limits by developing new approaches to switching, circuitry, and system integration. This presentation overviews the basic principles that operate on the nanometer scale that can be assembled into practical devices and circuits. Quantum resonant tunneling (RT) is used as the center-piece of the overview since RT devices already operate at high temperature (120 degrees C) and can be scaled, in principle, to a few nanometers in semiconductors. Near- and long-term applications of GaAs and silicon quantum devices are suggested for signal and information processing, memory, optoelectronics, and radio frequency (RF) communication.

Frazier, Gary↗