Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutron scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Thermal neutron imaging detector with wavelength shifting fiber and digital readout

Here, we developed a large area, digital thermal neutron imaging detector. The detector uses a 6 LiF/ZnS(Ag) neutron-sensitive scintillator combined with wavelength shifting fiber technology. The signals from fiber channels are amplified, integrated, and digitized using individual analog-to-digital converters for each channel. The neutron position is determined from the digitized signal using a least-squares gaussian-fitting algorithm. The detector size was 77 × 38 cm 2 (2926 cm 2 ), it provided 1.3 mm resolution, and its resolution can further be improved. The detector was designed for a powder diffraction neutron scattering beamline and provided substantial improvement of d-space resolution compared with existing detectors. This detector may have broader applications due to its large area and high spatial resolution extended over its large area.

6LiF/ZnS(Ag) scintillator↗

Characterization of stilbene-d 12 for neutron spectroscopy without time of flight

In this work, we have experimentally characterized the light-output response of a deuterated trans-stilbene (stilbene-d 12 ) crystal to quasi-monoenergetic neutrons in the 0.8 to 4.4 MeV energy range. These data allowed us to perform neutron spectroscopy measurements of a DT 14.1 MeV source and a 239 PuBe source by unfolding the impinging neutron spectrum from the measured light-output response. The stilbene-d 12 outperforms a 1 H-stilbene of similar size when comparing the shape of the unfolded spectra and the reference ones. These results confirm the viability of non-hygroscopic stilbene-d 12 crystal for direct neutron spectroscopy without need for time-of-flight measurements. This capability makes stilbene-d 12 a well suited detector for fast-neutron spectroscopy in many applications including nuclear reaction studies, radiation protection, nuclear non-proliferation, and space travel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental validation of scintillator detector response to correlated neutrons with MCNP and associated packages

Time, energy, and angle correlated neutrons are emitted in nuclear fission. New, physics-based fission event generators that capture these correlations have been incorporated into MCNP6.2 because correlations can impact nuclear non-proliferation and safeguards systems response. DRiFT is a detector response code that takes MCNP outputs and reproduces laboratory analogous detector quantities. Previous work has compared DRiFT to single detector experiment data and has discussed recent updates to DRiFT specific to correlated fission experiments. In this work, we demonstrate a validation of recent updates to DRiFT for organic scintillator response in correlated fission neutron experiments using a 252Cf source. Furthermore, outputs from MCNP with the FREYA fission event generator were post-processed with DRiFT and compared to experiment data. Simulation and experiment results are in reasonably good agreement for multiple correlated neutron quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerator measurement of NaI response to medium energy neutrons and application to a satellite-borne spectrometer

We report on the response of a prototype detector to medium energy neutrons. The neutrons were produced by n-p scattering of a neutron beam on a hydrogen target. The measurements provide unique data on the efficiency and response of large NaI scintillators to neutrons in the energy range 36-709 MeV. We apply the results to the high-energy mode of the Gamma-Ray Spectrometer (GRS) on the Solar Maximum Mission satellite by estimating its efficiency for neutron detection. This estimate is compared to earlier Monte Carlo calculations of the GRS efficiency.

Dunphy, P. P.↗

Serpent neutronics model of Wendelstein 7-X for 14.1 MeV neutrons

In this work, a Serpent 2 neutronics model of the Wendelstein 7-X (W7-X) stellarator is prepared, and an response function for the Scintillating-Fibre neutron detector (SciFi) is calculated using the model. The neutronics model includes the simplified geometry for the key components of the stellarator itself as well as the torus hall. The objective of the model is to assess the 14.1 MeV neutron flux from deuteron-triton fusions in W7-X, where the neutrons are modelled only until they have slowed down to 1 MeV energy. The key messages of this article are: demonstration of unstructured mesh geometry usage for stellarators, W7-X in particular; technical documentation of the model and first insights in fast neutron behaviour in W7-X, especially related to the SciFi: the model indicates that the superconducting coils are the strongest scatterers and block neutrons from large parts of the plasma. The back-scattering from e.g. massive steel support structures is found to be small. The SciFi will detect neutrons from an extended plasma volume in contrast to having an effective line-of-sight.

14 MeV↗

Scintillation Hydro-Gel for Isotopic Neutron (SHINE): Eco-Friendly Quantum Dot Neutron Detectors

The development of new neutron detectors to replace helium-3 (3He) detectors is imperative due to a worldwide shortage of 3He following the draw down in nuclear weapons production since the end of the Cold War. The United States Department of Homeland Security would like to deploy monitors for the detection of neutron emissions from shipping containers housing illicit nuclear material; however, this effort has been put on hold until new replacements for 3He detectors can be developed. Scintillation Hydro-Gel for isotopic Neutron Emitters (SHINE) is a unique, first of its kind, 6Li-loaded quantum dot gel scintillator developed at INL. By incorporating 6Li with quantum dots in a gel matrix, SHINE displays the best properties of liquid and solid scintillators without their disadvantages such as continuous filtering to keep liquids free of contaminates, slow throughput of containers, higher base component costs, ‘dead’ voids in solid scintillators, and a high loading of 6Li without compromising on light transparency. Additionally, SHINE is completely eco-friendly, a breakthrough in high-efficiency detection systems. SHINE is a unique combination of 6LiCl, a highly water-soluble compound, and InP/ZnS core/shell quantum dots, which are poured into a gel-form using cross-linking polymers. In this presentation, SHINE has been successfully tested for neutron detection and shows promise as both a replacement for current 3He neutron detectors as well as potential use in handheld, compact neutron detection units and antineutrino detection.

36 MATERIALS SCIENCE↗

From Detector Layout to Signal Analysis: Geometry Optimization and Neutron-Gamma Tagging in Plastic Scintillator Detectors

Neutrinos are elementary particles with many properties still unknown. Their masses so far have only upper and lower limits. Still, due to neutrino oscillations, it is clear that they are not massless, as stated by the Standard Model of Elementary Particles. Neutrinos are also present in the Universe in vast amounts, but they rarely interact with the surrounding matter. Their abundance makes them very interesting for many theories beyond the Standard Model, e.g., dark matter searches and CP symmetry violation in the leptonic sector, which could be (partially) responsible for the observed matter-antimatter asymmetry in today's Universe.\\ The Deep Underground Neutrino Experiment (DUNE) is a next-generation accelerator-based neutrino oscillation experiment that will study neutrinos with unprecedented precision and may answer many open questions. DUNE uses a powerful neutrino beam from Fermilab. It consists of a Near Detector (ND) complex to measure neutrinos before oscillat ion, and a Far Detector (FD) complex $1300\ \mathrm{km}$ away to measure them after oscillation. As part of the ND complex, measurements are also possible with different angles to the neutrino beam. This enables excellent control of systematic uncertainties of e.g., neutrino cross section measurements.\\ One detector in the near detector complex is The Muon Spectrometer (TMS), an extension of a Liquid Argon (LAr) detector that measures the charge and momentum of muons produced in neutrino interactions within the LAr. The design of this detector, which consists of alternating layers of steel and plastic scintillator bars, must be optimized for the expected muon energies.\\ In this thesis, a study of the optimal module orientation plan is presented, which is necessary for the physics performance of the near detector complex and, by extension, DUNE. As part of this study, the event reconstruction was also developed and improved. Simulated muons are then reconstructed, and the performan ce of different module orientation plans is tested.\\ As a second part, a study of neutron and gamma tagging using a Pulse Shape Discriminating (PSD) plastic scintillator is presented. The properties of this material allow particle differentiation based on the temporal distribution of emitted light. A novel approach to using the individual light signals was successfully tested using data from a small, local test setup.

Nehm, Asa [Mainz U.]↗

Instrument design for an inertial confinement fusion ion temperature imager

A mix of contaminant mass is a known, performance-limiting factor for laser-driven inertial confinement fusion (ICF). It has also recently been shown that the contaminant mass is not necessarily in thermal equilibrium with the deuterium–tritium plasma. Contaminant mass temperature is one of the dominant uncertainties in contaminant mass estimates. The MixIT diagnostic is a new and potentially transformative diagnostic, capable of spatially resolving ion temperature. The approach combines principles of neutron time-of-flight and neutron imaging diagnostics. The information from the MixIT diagnostic can be used to optimize ICF target and laser drive designs as well as provide key constraints on ICF radiation-hydrodynamic simulations that are critical to contaminant mass estimates. This work details the design and optimization of the major components of the MixIT diagnostic: the neutron aperture, the neutron detector (scintillator), and the recording system.

47 OTHER INSTRUMENTATION↗

Advances in detection for neutron reflectometry with time-resolved imaging detectors

Thermal neutron detection in neutron scattering science is a challenging endeavour due to a limited number of technologies which are sensitive to these weakly interacting particles. While many improvements to conventional detectors are underway at various facilities, there is a great opportunity to make a leap in performance by combining the spatial resolution benefits of imaging and the temporal resolution and background discrimination of event-driven radiation detectors. This idea has been realized by using a neutron sensitive scintillator read out by a single-photon sensitive camera based on a Timepix3 ASIC. We demonstrate how such data-driven imaging sensors can enable unprecedented performance in neutron reflectometry using the ASTERIX instrument at the Los Alamos Neutron Scattering Center. Several samples were measured with both the new and a conventional 3 He detector systems. The results from this work demonstrate that these imaging based systems can satisfy performance parameters for the future QIKR reflectometer to be built at the Second Target Station at Oak Ridge National Laboratory. Further improvements to the detector are already underway which will allow streamlined and expedited experiments. We demonstrate at least a two order of magnitude increase in detection rate at an acceptable dead time and introduce a new way of tuning the detector efficiency using light collecting optics to accommodate highly intense direct beams which cannot be measured with any current detectors without severe attenuation. This will allow measurements of complete reflectometry profiles and using a single sample measurement combined with fewer direct beam calibration measurements on QIKR and potentially other reflectometers.

36 MATERIALS SCIENCE↗

Design of a Cryogenic Scintillation Neutrino Detector at the Spallation Neutron Source

We successfully verified in the following three aspects the feasibility of using a cryogenic scintillating crystal-based neutrino detector at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory, for the detection of low-mass dark matter particles and non-standard neutrino interactions (NSIs), as part of the detector R&D effort of the COHERENT experiment. First, we demonstrated the possibility of using silicon photomultipliers (SiPMs) at cryogenic temperatures to replace traditional photomultiplier tubes (PMTs) as light sensors. Second, we verified that the high light yield of undoped CsI crystals measured above 13 keVee at 77 K still holds down to 5.9 keVee. Third, we successfully measured nuclear quenching factor of undoped cryogenic CsI at the Triangle Universities Nuclear Laboratory with the help from our Duke collaborators. The first achievement resulted in a publication in European Physics Journal C. The second resulted in an arXiv pre-print, which is under journal review. The last one indicates that the performance of the proposed detector may be better than what was assumed in the literature. The analysis is in the final stage and will result in another journal publication. In addition, two graduate students involved in this project graduated with master’s degrees during the project period. Both decided to continue their research as PhD students. One open-source data analysis code package was created and is publicly available on GitHub. A set of tutorials about Monte Carlo simulation of radiation interacting with detectors were created on YouTube, receiving more than 100,000 views.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron Positioning and Geometric Distortion Correction on the SNS SiPM Anger Camera

Neutron Anger cameras are scintillator-based thermal neutron detectors that utilize pixelated photosensors to read out visible light signals and position neutrons accurately They are versatile detectors that can cover large areas for diffraction instruments and offer high efficiency and sub-millimeter spatial resolution. Photomultiplier Tube (PMT) based cameras are installed on three instruments at Spallation Neutron Source (SNS). The next generation camera uses Silicon Photomultipliers (SiPMs) instead of PMTs, which allows for a more compact design and higher spatial resolution. In this report, the Gaussian least-squares position fitting method is described in detail, as well as the method used to correct for geometric distortions across the face of the camera. Results from neutron camera tests before and after the distortion correction are shown and the spatial resolution is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deployment of Water-based Liquid Scintillator in the Accelerator Neutrino Neutron Interaction Experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton water Cherenkov neutrino detector installed on the Booster Neutrino Beam (BNB) at Fermilab. Its main physics goals are to perform a measurement of the neutron yield from neutrino-nucleus interactions, as well as a measurement of the charged-current cross section of muon neutrinos. An equally important focus is the research and development of new detector technologies and target media. Specifically, water-based liquid scintillator (WbLS) is of interest as a novel detector medium, as it allows for the simultaneous detection of Cherenkov light and scintillation. This paper presents the deployment of a 366 L WbLS vessel in ANNIE in March 2023 and the subsequent detection of both Cherenkov light and scintillation from the WbLS. Finally, this proof-of-concept allows for the future development of reconstruction and particle identification algorithms in ANNIE, as well as dedicated analyses within the WbLS volume, such as the search for neutral-current events and the hadronic scintillation component.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of EJ-270 and Ce-doped LiCAF scintillators for the development of high-rate neutron reflectometer detectors

The Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory is anticipated to provide a neutron source with ∼20 times increase in peak brightness than the First Target Station. The neutron reflectometers currently in operation at the First Target Station need to be upgraded due to the increased neutron flux. A prototype neutron detector module based upon a pixelated scintillator array readout by silicon photomultipliers is being developed to address the high-rate challenge faced with future neutron reflectometer instruments at the Second Target Station. Two types of scintillator materials were considered for this detector development, i.e., 6 Li-loaded EJ-270 plastic scintillator and Ce-doped LiCAF single crystal. This paper reports the scintillator characterization results, including light yield, pulse shape discrimination performance, capability to detect thermal neutrons in a high γ-ray field, and γ-ray sensitivity. The number of photons produced per neutron capture by EJ-270 and LiCAF:Ce was measured to be 2176 ± 91 and 2651 ± 108, respectively. EJ-270 demonstrated a good capability to discriminate between neutrons and γ-rays by employing the commonly used charge comparison method (figure-of-merit: 1.13 ± 0.01 for an energy cut of 292–426 keVee) and a reasonable performance when using the time-over-threshold techniques; however, no discrimination was observed from LiCAF:Ce regardless of the pulse shape discrimination approaches utilized, making pulse height discrimination necessary for LiCAF:Ce to differentiate between neutrons and γ-rays. Both EJ-270 and LiCAF:Ce exhibited an acceptable capacity to detect thermal neutrons at high exposure rates up to approximately 584 mR/h. Furthermore, the γ-ray sensitivities measured with a 60 Co source at an exposure rate of around 1145 mR/h were determined to be (6.11 ± 0.87) × 10 −6 and (7.64 ± 1.08) × 10 −7 for EJ-270 and LiCAF:Ce, respectively.

EJ-270↗

Demonstration of neutron time-of-flight diffraction with an event-mode imaging detector

Neutron diffraction beamlines have traditionally relied on deploying large detector arrays of 3 He tubes or neutron-sensitive scintillators coupled with photomultipliers to efficiently probe crystallographic and microstructure information of a given material. Given the large upfront cost of custom-made data acquisition systems and the recent scarcity of 3 He, new diffraction beamlines or upgrades to existing ones demand innovative approaches. This paper introduces a novel Timepix3-based event-mode imaging neutron diffraction detector system as well as first results of a silicon powder diffraction measurement made at the HIPPO neutron powder diffractometer at the Los Alamos Neutron Science Center. Notably, these initial measurements were conducted simultaneously with the 3 He array on HIPPO, enabling direct comparison. Data reduction for this type of data was implemented in the MAUD code, enabling Rietveld analysis. Results from the Timepix3-based setup and HIPPO were benchmarked against McStas simulations, showing good agreement for peak resolution. With further development, systems such as the one presented here may substantially reduce the cost of detector systems for new neutron instrumentation as well as for upgrades of existing beamlines.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization and description of a spectrum unfolding method for the $\mathrm{CATRiNA}$ neutron detector array

We report the CATRiNA deuterated neutron detector array at Florida State University consists of 16 2" x 2" and 16 $" x 2" EJ-315 detectors with characteristic light output and pulse-shape discrimination capabilities. The unique properties of the detectors, in part due to the anisotropic nature of (d,n) scattering, are used to extract the energy of neutrons via pulse-height spectrum unfolding. The unfolding method uses the light output and response matrix of the detectors to extract neutron energies, independent of the traditional time-of-flight (ToF) technique. Detailed response matrices of the CATRiNA detectors were measured at the Edwards Accelerator Laboratory at Ohio University via the 9 Be(d,n) and 27 Al(d,n) reactions. Full characterization of the detectors using digital electronics, as well as a description of the unfolding method are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Luminescence properties of europium doped and sodium co-doped LiCaAlF 6

This paper serves as a literature review of scintillating thermal neutron detectors, along with a study of sodium and europium doped LiCaAlF 6 (LiCAF) polycrystalline material. A set of polycrystalline LiCAF material was synthesized with 2 molar percent of europium (Eu 2+ ) and co-doped with 0, 1, and 2 molar percent of sodium (Na + ), with a stoichiometric synthesis approach in a glassy-carbon crucible. The quantum yield and photoluminescence spectrum at room temperature was analyzed. For the first time, we have demonstrated that Na-co-doping directly alters the quantum yield. The quantum yield for LiCAF:Eu 2+ , with 0, 1, and 2 molar percent of sodium (Na + ) was 0.578, 0.635, and 0.580, respectively. The photoluminescence (PL) spectrum was also analyzed for all samples. The photo-luminescence excitation (PLE) spectrum showed a maximum at 300 nm, while the emission spectrum showed a maximum at 370 nm, corresponding to the Eu 2+ 5d-4f transitions.

36 MATERIALS SCIENCE↗