Search NASA⌕ Search

SEARCH · Search NASA

Results for “noise contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Inlet Spillage Drag Predictions Using the AIRPLANE Code

AIRPLANE (Jameson/Baker) is a steady inviscid unstructured Euler flow solver. It has been validated on many HSR geometries. It is implemented as MESHPLANE, an unstructured mesh generator, and FLOPLANE, an iterative flow solver. The surface description from an Intergraph CAD system goes into MESHPLANE as collections of polygonal curves to generate the 3D mesh. The flow solver uses a multistage time stepping scheme with residual averaging to approach steady state, but R is not time accurate. The flow solver was ported from Cray to IBM SP2 by Wu-Sun Cheng (IBM); it could only be run on 4 CPUs at a time because of memory limitations. Meshes for the four cases had about 655,000 points in the flow field, about 3.9 million tetrahedra, about 77,500 points on the surface. The flow solver took about 23 wall seconds per iteration when using 4 CPUs. It took about eight and a half wall hours to run 1,300 iterations at a time (the queue limit is 10 hours). A revised version of FLOPLANE (Thomas) was used on up to 64 CPUs to finish up some calculations at the end. We had to turn on more communication when using more processors to eliminate noise that was contaminating the flow field; this added about 50% to the elapsed wall time per iteration when using 64 CPUs. This study involved computing lift and drag for a wing/body/nacelle configuration at Mach 0.9 and 4 degrees pitch. Four cases were considered, corresponding to four nacelle mass flow conditions.

Thomas, Scott D.↗

Challenges of AVHRR Vegetation Data for Real Time Applications

Remote sensing data has long been used to monitor global ecosystems for floods and droughts and AVHRR data, as one of the first product, has many users interested in receiving the data within hours of acquisition. With the introduction of a new series of sensors in 2000 (the AVHRR/3 series), the quality of the NDVI datasets available for real time environmental monitoring has declined. This paper provides evidence of problems of cloud contamination, calibration and noise in the real time data which are not present in the historical AVHRR NDVIg dataset. These differences introduce significant uncertainty in the use of the real time data, degrading their utility for detecting climate variations in near real time.

Brown, Molly↗

Confirming Interstellar C60(+) Using the Hubble Space Telescope

Recent advances in laboratory spectroscopy lead to the claim of ionized Buckminsterfullerene (C60(+)) as the carrier of two diffuse interstellar bands (DIBs) in the near-infrared. However, irrefutable identification of interstellar C60(+) requires a match between the wavelengths and the expected strengths of all absorption features detectable in the laboratory and in space. Here we present Hubble Space Telescope (HST) spectra of the region covering the C60(+) 9348, 9365, 9428, and 9577 Å absorption bands toward seven heavily reddened stars. We focus in particular on searching for the weaker laboratory C60(+) bands, the very presence of which has been a matter for recent debate. Using the novel STIS-scanning technique to obtain ultra-high signal-to-noise spectra without contamination from telluric absorption that afflicted previous ground-based observations, we obtained reliable detections of the (weak) 9365, 9428 Å and (strong) 9577 Å C60(+) bands. The band wavelengths and strength ratios are sufficiently similar to those determined in the latest laboratory experiments that we consider this the first robust identification of the 9428 Å band, and a conclusive confirmation of interstellar C60(+).

Cordiner, M. A.↗

NuSTAR Measurement of the Cosmic X-ray Background in the 3–20 keV Energy Band

We present measurements of the intensity of the cosmic X-ray background (CXB) with the Nuclear Spectroscopic Telescope Array (NuSTAR) telescope in the 3–20 keV energy range. Our method uses spatial modulation of the CXB signal on the NuSTAR detectors through the telescope’s side aperture. Based on the NuSTAR observations of selected extragalactic fields with a total exposure of 7 Ms, we have estimated the CXB 3–20 keV flux to be 2.8×10−11erg s−1cm−2deg−2, which is∼8 per cent higher than that measured withHEAO-1and consistent with the INTEGRAL measurement. The inferred CXB spectral shape in the3–20 keV energy band is consistent with the canonical model of Gruber et al. We demonstrate that the spatially modulated CXB signal measured by NuSTAR is not contaminated by systematic noise and is limited by photon statistics. The measured relative scatter of the CXB intensity between different sky directions is compatible with cosmic variance, which opens new possibilities for studying CXB anisotropy over the whole sky with NuSTAR.

Detectors↗

Fermilab PIP-II machine protection system digitized data noise elimination scheme and its FPGA implementation

In Fermilab's PIP-II machine protection system, beam loss signals from various detectors are digitized at 125 MS/s. Noise from both high-frequency sources and low-frequency 60 Hz AC power equipment can contaminate the data. To suppress noise across these ranges—especially 60 Hz and its harmonics, which overlap with beam loss signal frequencies—advanced digital processing beyond standard filtering is required. Several real-time functional blocks were simulated and tested on an FPGA: (1) a dual time-constant discharging integrator filter, (2) a de-ripple baseline extraction and storage block, and (3) a fast-recovery discharging integrator. The nonlinear IIR integrator filter removes high-frequency noise and feeds into the baseline extractor. Upon detecting abrupt beam loss, it switches to a longer time constant to prevent baseline distortion. The de-ripple block calculates a valid baseline by averaging over multiple 60 Hz periods, storing results in a 4096-word FPGA RAM. This baseline is subtracted from raw data before integration by the fast-recovery block, which resets quickly after use. All blocks achieved expected performance and were successfully implemented on a low-cost FPGA.

Wu, Jinyuan [Fermilab]↗

New interpretations of shock-associated noise with and without screech

Anomalous trends in present convergent nozzle (Mach 1) shock-associated noise analyses and predictions, with particular emphasis on the roles of screech and jet temperature, are discussed. Experimentally measured values of shock-associated noise are used to reassess data trends, including both frequency and sound pressure level. The data used includes model-scale nozzles, varying in nominal diameter from 5 cm to 13 cm, and full-scale engine nozzles up to 48 cm. All data were obtained at static conditions. From this reassessment of the measured data, new empirical methods for the prediction of shock-associated noise are developed. Separate procedures are presented for screech-free and screech-contaminated shock-associated noise. In the present approach, shock-associated noise spectra are developed from considerations that include the peak sound pressure level and its frequency, the low frequency sound pressure level slope, and the high frequency sound pressure level slope or roll-off; the latter is shown to vary with directivity angle.

Von Glahn, U.↗

Flight-Test Evaluation of Landing Gear Noise Reduction Technologies

Results from the third Acoustics Research Measurements flight test, conducted under the NASA Flight Demonstrations and Capabilities project, are presented and discussed. The test evaluated landing gear and gear cavity noise mitigation technologies installed on a NASA Gulfstream G-III. Aircraft configurations with and without main landing gear treatments were flown at several flap deflections to determine the acoustic performance of the technologies for aircraft equipped with conventional Fowler flaps. With the aircraft flying an approach path and engines at “ground-idle,” extensive acoustic measurements were acquired with a phased microphone array system. Computed beamform maps were used to examine the effectiveness of the tested technologies in reducing the strength of the noise sources generated by the main landing gear. Various integration regions were devised to extract the farfield noise spectra associated with the treated and untreated landing gear configurations. Analyses of the gathered acoustic data demonstrate that significant noise reduction was achieved. How- ever, the full noise reduction potential of the technologies could not be determined because of contamination from flap inboard edge noise and other secondary sources.

Khorrami, Mehdi R.↗

Flight-Test Evaluation of Landing Gear Noise Reduction Technologies

Results from the third Acoustics Research Measurements flight test, conducted under the NASA Flight Demonstrations and Capabilities project, are presented and discussed. The test evaluated landing gear and gear cavity noise mitigation technologies installed on a NASA Gulfstream G-III. Aircraft configurations with and without main landing gear treatments were flown at several flap deflections to determine the acoustic performance of the technolo-gies for aircraft equipped with conventional Fowler flaps. With the aircraft flying an approach path and engines at “ground-idle,” extensive acoustic measurements were acquired with a phased microphone array system. Computed beamform maps were used to examine the effec-tiveness of the tested technologies in reducing the strength of the noise sources generated by the main landing gear. Various integration regions were devised to extract the farfield noise spectra associated with the treated and untreated landing gear configurations. Analyses of the gathered acoustic data demonstrate that significant noise reduction was achieved. How-ever, the full noise reduction potential of the technologies could not be determined because of contamination from flap inboard edge noise and other secondary sources.

Mehdi R Khorrami↗

Fermilab PIP II machine protection system digitized data noise elimination scheme and its FPGA implementation

In Fermilab's PIP-II machine protection system, beam loss signals from various detectors are digitized at 125 MS/s. Noise from both high-frequency sources and low-frequency 60 Hz AC power equipment can contaminate the data. To suppress noise across these ranges especially 60 Hz and its harmonics, which overlap with beam loss signal frequencies advanced digital processing beyond standard filtering is required. Several real-time functional blocks were simulated and tested on an FPGA: (1) a dual time-constant discharging integrator filter, (2) a de-ripple baseline extraction and storage block, and (3) a fast-recovery discharging integrator. The nonlinear IIR integrator filter removes high-frequency noise and feeds into the baseline extractor. Upon detecting abrupt beam loss, it switches to a longer time constant to prevent baseline distortion. The de-ripple block calculates a valid baseline by averaging over multiple 60 Hz periods, storing results in a 4096-word FPGA RAM. This baseline is subtracted from raw data before integration by the fast-recovery block, which resets quickly after use. All blocks achieved expected performance.

Wu, J. [Fermilab] (ORCID:0000000344329521)↗

Background Noise Reduction Using Adaptive Noise Cancellation Determined by the Cross-Correlation

Background noise due to flow in wind tunnels contaminates desired data by decreasing the Signal-to-Noise Ratio. The use of Adaptive Noise Cancellation to remove background noise at measurement microphones is compromised when the reference sensor measures both background and desired noise. The technique proposed modifies the classical processing configuration based on the cross-correlation between the reference and primary microphone. Background noise attenuation is achieved using a cross-correlation sample width that encompasses only the background noise and a matched delay for the adaptive processing. A present limitation of the method is that a minimum time delay between the background noise and desired signal must exist in order for the correlated parts of the desired signal to be separated from the background noise in the crosscorrelation. A simulation yields primary signal recovery which can be predicted from the coherence of the background noise between the channels. Results are compared with two existing methods.

Spalt, Taylor B.↗

Transient recovery problem in acoustics: A multichannel model-based deconvolution approach

Critical acoustical systems operating in complex environments contaminated with disturbances and noise offer an extreme challenge when excited by out-of-the-ordinary, impulsive, transient events that can be undetected and seriously affect their overall performance. Transient impulse excitations must be detected, extracted, and evaluated to determine any potential system damage that could have been imposed; therefore, the problem of recovering the excitation in an uncertain measurement environment becomes one of multichannel deconvolution. Recovering a transient and its initial energy has not been solved satisfactorily, especially when the measurement has been truncated and only a small segment of response data is available. The development of multichannel deconvolution techniques for both complete and incomplete excitation data is discussed, employing a model-based approach based on the state-space representation of an identified acoustical system coupled to a forward modeling solution and a Kalman-type processor for enhancement and extraction. In conclusion, synthesized data are utilized to assess the feasibility of the various approaches, demonstrating that reasonable performance can be achieved even in noisy environments.

42 ENGINEERING↗

New shield for gamma-ray spectrometry

Gamma-ray shield that can be evacuated, refilled with a clean gas, and pressurized for exclusion of airborne radioactive contaminants effectively lowers background noise. Under working conditions, repeated evacuation and filling procedures have not adversely affected the sensitivity and resolution of the crystal detector.

Brar, S. S.↗

An evaluation of Space Shuttle STS-2 payload bay acoustic data and comparison with predictions

Space average sound pressure levels computed from measurements at 18 locations in the payload bay of the Space Shuttle orbiter vehicle during the STS-2 launch were compared with predicted levels obtained using the PACES computer program. The comparisons were performed over the frequency range 12.5 Hz to 1000 Hz, since the test data at higher frequencies are contaminated by instrumentation background noise. In general the PACES computer program tends to overpredict the space average sound levels in the payload bay, although the magnitude of the discrepancy is usually small. Furthermore the discrepancy depends to some extent on the manner in which the payload is modeled analytically, and the method used to determine the "measured' space average sound pressure levels. Thus the difference between predicted and measured sound levels, averaged over the 20 one third octave bands from 12.5 Hz to 1000 Hz, varies from 1 dB to 3.5 dB.

Wilby, J. F.↗

Comparison of several techniques to obtain multiple-look SAR imagery

In order to improve image interpretability when SAR imagery is contaminated by coherent speckle noise, multiple look images are often generated. The performance levels of techniques for the generation of such multiple look imagery are presently assessed, with attention to the detailed impulse responses and signal-to-speckle noise ratios obtainable. The speckle-reduction technique considered are those of the discrete mixed integrator and the image domain filter. It is found that, by using several types of image domain filters, the signal-to-speckle noise ratio can be improved over the conventional discrete mixed integrator method's results while maintaining the equivalent rectangular resolution constant.

Li, F.-K.↗

Space Station medical sciences concepts

Current life sciences concepts relating to Space Station are presented including the following: research, extravehicular activity, biobehavioral considerations, medical care, maintenance of dental health, maintaining health through physical conditioning and countermeasures, protection from radiation, atmospheric contamination control, atmospheric composition, noise pollution, food supply and service, clothing and furnishings, and educational program possibilities. Information on the current status of Soviet Space Stations is contained.

Mason, J. A.↗

Space Station medical sciences concepts

Current life sciences concepts relating to Space Station are presented including the following: research, extravehicular activity, biobehavioral considerations, medical care, maintenance of dental health, maintaining health through physical conditioning and countermeasures, protection from radiation, atmospheric contamination control, atmospheric composition, noise pollution, food supply and service, clothing and furnishings, and educational program possibilities. Information on the current status of Soviet Space Stations is contained.

Mason, J. A.↗

The effects of wall surface defects on boundary-layer transition in quiet and noisy supersonic flow

The design of supersonic vehicles with laminar flow control and vehicles such as the Space Shuttle requires information on allowable transition tolerances to fabrication defects such as discrete surface roughness and waviness. A relatively large data base on the effects of discrete roughness on transition exists for subsonic and supersonic speeds. The existing supersonic wind tunnel transition data are contaminated by wind tunnel noise emanating from the turbulent boundary layers on the nozzle walls. Roughness and waviness transition data obtained in a quiet Mach 3.5 supersonic wind tunnel are compared with those obtained in conventional noisy flows.

Morrisette, E. Leon↗

A medium-scale measurement of the cosmic microwave background at 3.3 millimeters

A system has been developed for making measurements of spatial fluctuations in the cosmic microwave background radiation, on an angular scale of 5 arcmin to a few degrees. The system consists of an off-axis Gregorian telescope with a nearly Gaussian response with FWHM adjustable from 20 to 50 arcmin, an SIS coherent receiver operating at 3.3 mm, and a pointing system capable of better than 1 arcmin rms stabilization. This paper reports on results from the system's first balloon flight in August 1988, and ground-based measurements made from the South Pole in December 1988. A portion of the South Pole data is used to place a 95-percent confidence level upper limit of Delta T/T less than 0.000035 for Gaussian sky fluctuations in the background radiation at 20-arcmin angular scale and a limit of Delta T/T less than 0.000033 on overall excess intrinsic sky noise. In addition, dust contamination in cosmic background radiation data is estimated using measurements of the Galaxy from this flight and a previous one, along with the IRAS 100-micron map. These anisotropy results give the most stringent limits on cold dark matter theories to date.

Meinhold, Peter↗