Search NASA⌕ Search

SEARCH · Search NASA

Results for “non-invasive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Comparisons of three anti-G suit configurations during long duration, low onset, +Gz

Little physiologic data exist on the effects of long duration, low onset, hypergravity (+G). Space shuttle crewmembers are subjected to low +G forces (less than +3G) for upwards of 30 minutes during reentry. A similar reentry profile is predicted for the National Aerospace Plane (NASP). The physiologic effects of this acceleration stress are compounded by the loss of body water experienced during microgravity. Currently, a standard 5 bladder anti-G suit is being used during shuttle reentry. There have been complaints of discomfort using this suit, mainly due to the abdominal bladder. This study compared the effectiveness of three anti-G suit configurations in volume depleted subjects during a simulated space shuttle reentry profile. Methods: Seven male subjects were given intravenous Lasix in a dose from 20-40 mg to induce a total body weight loss of 3 plus or minus 1.5 percent. Approximately six hours after the injection, the subjects donned one of three anti-G suits - a standard 5 bladder anti-G suit, an extended coverage anti-G suit (the advanced technology anti-G suit or ATAGS), or an extended coverage anti-G suit without an abdominal bladder (the reentry anti-G suit or REAGS). All subjects were exposed to a simulated space shuttle reentry profile. Non-invasive eye-level blood pressure (ELBP) was monitored throughout the +G exposure. When systolic ELBP dropped below 70 mmHg, the anti-G suit was inflated in 0.5 psig increments to the pressure required to maintain 70 mmHg ELBP. Each subject rode with all three suits. Comparisons were made between the final pressure required in each suit to maintain ELBP and subjective reports of comfort. Results: The mean final suit pressure required to maintain ELBP was 1.1 psi, in both the ATAGS and REAGS versus 1.8 psi in the standard suit. In addition, the subjects rated the REAGS suit highest on the comfort scale, citing the absence of the abdominal bladder as the main reason. Conclusions: Overall, the REAGS suit was the superior anti-G suit during long duration, low onset +G. This is based on its ability to maintain ELBP and still remain comfortable when inflated for prolonged periods of time.

Stegmann, B. J.↗

A preview of a modular surface light scattering instrument with autotracking optics

NASA's Advanced Technology Development (ATD) program is sponsoring the development of a new generation of surface light scattering hardware. This instrument is designed to non-invasively measure the surface response function of liquids over a wide range of operating conditions while automatically compensating for a sloshing surface. The surface response function can be used to compute surface tension, properties of monolayers present, viscosity, surface tension gradient and surface temperature. The instrument uses optical and electronic building blocks developed for the laser light scattering program at NASA Lewis along with several unique surface light scattering components. The emphasis of this paper is the compensation for bulk surface motion (slosh). Some data processing background information is also included.

Meyer, William V.↗

Technical and commerical challenges in high Tc SQUIDs and their industrial applications

A SQUID is the most sensitive device for measuring changes in magnetic flux. Since its discovery in the sixties, scientists have made consistent efforts to apply SQUID's to various applications. Instruments that are the most sensitive in their respective categories have been built, such as SQUID DC susceptometer that is now manufactured by Quantum Design, pico-voltmeter which could measure 10(exp -14) volts, and gravitational wave detectors. One of the most successful applications of SQUID's is in magnetoencephalography, a non-invasive technique for investigating neuronal activity in the living human brain. This technique employs a multi-channel SQUID magnetometer that maps the weak magnetic field generated by small current when information is processed in brain, and its performance is marvelous.

Lu, D. F.↗

Sizing of colloidal particle and protein molecules in a hanging fluid drop

We report non-invasive particle size measurements of polystyrene latex colloidal particles and bovine serum albumin (BSA) protein molecules suspended in tiny hanging fluid drops of 30 micro-Liter volume using a newly designed fiber optic probe. The probe is based upon the principles of the technique of dynamic light scattering (DLS). The motivation for this work comes from growing protein crystals in outer space. Protein crystals have been grown previously in hanging drops in microgravity experiments on-board the space shuttle orbiter. However, obtaining quantitative information on nucleation and growth of the protein crystals in real time has always been a desired goal, but hitherto not achieved. Several protein researchers have shown interest in using DLS to monitor crystal growth process in a droplet, but elaborate instrumentation and optical alignment problems have made in-situ applications difficult. We demonstrate that such an experiment is now possible. Our system offers fast (5 seconds) determination of particle size, utilize safe levels of very low laser power (less than or equal to 0.2 mW), a small scattering volume (approximately 2 x 10(exp -5) cu mm) and high spatial coherence (Beta) values. This is a major step forward when compared to currently available DLS systems.

Ansari, Rafat R.↗

Ultrasound measurement of transcranial distance during head-down tilt

Exposure to microgravity elevates blood pressure and flow in the head, which may increase intracranial volume (ICV) and intracranial pressure (ICP). Rhesus monkeys exposed to simulated microgravity in the form of 6 degree head-down tilt (HDT) experience elevated ICP. With humans, twenty-four hours of 6 degree HDT bed rest increases cerebral blood flow velocity relative to pre-HDT upright posture. Humans exposed to acute 6 degree HDT experiments increased ICP, measured with the tympanic membrane displacement (TMD) technique. Other studies suggest that increased ICP in humans and cats causes measurable cranial bone movement across the sagittal suture. Due to the slightly compliant nature of the cranium, elevation of the ICP will increase ICV and transcranial distance. Currently, several non-invasive approaches to monitor ICP are being investigated. Such techniques include TMD and modal analysis of the skull. TMD may not be reliable over a large range of ICP and neither method is capable of measuring the small changes in pressure. Ultrasound, however, may reliably measure small distance changes that accompany ICP fluctuations. The purpose of our study was to develop and evaluate an ultrasound technique to measure transcranial distance changes during HDT.

Torikoshi, S.↗

Determination of the Residence Time of Food Particles During Aseptic Sterilization

The paper describes a non-invasive method to measure the time an individual particle takes to move through a length of stainless steel pipe. The food product is in two phase flow (liquids and solids) and passes through a pipe with pressures of approximately 60 psig and temperatures of 270-285 F. The proposed problem solution is based on the detection of transitory amplitude and/or phase changes in a microwave transmission path caused by the passage of the particles of interest. The particles are enhanced in some way, as will be discussed later, such that they will provide transitory changes that are distinctive enough not to be mistaken for normal variations in the received signal (caused by the non-homogeneous nature of the medium). Two detectors (transmission paths across the pipe) will be required and place at a known separation. A minimum transit time calculation is made from which the maximum velocity can be determined. This provides the minimum residence time. Also average velocity and statistical variations can be computed so that the amount of 'over-cooking' can be determined.

Carl, J. R.↗

Experiment K-7-35: Circadian Rhythms and Temperature Regulation During Spaceflight: Metabolism - Part 2

Energy expenditure can be regarded as the sum of two components; the basal metabolic rate and the energy costs of activity. Weight loss is usually associated with an energy deficit. A negative energy balance exists when energy intake is less that energy utilization. The deficit is made up by tissue catabolism (principally fat, but also some protein). By analyzing food and water intake, urine and fecal output, and changes in body weight, the Skylab investigators reached the unexpected conclusion that energy expenditure during spaceflight was about 5% greater than at 1 G (Leonard, 1983; Rambaut et al., 1977). Possible explanations for the human metabolic responses are an increased workload during spaceflight (Leonard, 1983), or as Rambaut and co-workers (1977) suggested, a progressive decrease in metabolic efficiency. It is likely to be very difficult to distinguish between these two possibilities in man because the activity component may be different during spaceflight than it is the ground. The problem is to measure energy expenditure with efficient precision during spaceflight in a non-invasive manner which will not interfere with other investigations or take an time. The doubly labeled water (DLW) method meets these criteria. The DLW method is the only method available for continuously measuring energy expenditure during spaceflight given the severely restricted conditions in the spaceflight environment. Therefore, this study focuses on the development and use of this procedure on nonhuman primates during spaceflight. Energy expenditure and total body water was determined in two Rhesus monkeys by the doubly labeled water (2H2'80) method. Three determinations were made. Monkey B (#2483) was studied twice, during the flight of COSMOS 2044 and during a follow-up ground control study a month later. A second monkey was studied on the ground only (Monkey D, #782).

Fuller, C. A.↗

Workshop on Advances in NASA-Relevant, Minimally Invasive Instrumentation

The purpose of this meeting is to highlight those advances in instrumentation and methodology that can be applied to the medical problems that will be encountered as the duration of manned space missions is extended. Information on work that is presently being done by NASA as well as other approaches in which NASA is not participating will be exchanged. The NASA-sponsored efforts that will be discussed are part of the overall Space Medicine Program that has been undertaken by NASA to address the medical problems of manned spaceflight. These problems include those that have been observed in the past as well as those which are anticipated as missions become longer, traverse different orbits, or are in any way different. This conference is arranged in order to address the types of instrumentation that might be used in several major medical problem areas. Instrumentation that will help in the cardiovascular, musculoskeletal, and psychological areas, among others will be presented. Interest lies in identifying instrumentation which will help in learning more about ourselves through experiments performed directly on humans. Great emphasis is placed on non-invasive approaches, although every substantial program basic to animal research will be needed in the foreseeable future. Space Medicine is a rather small affair in what is primarily an engineering organization. Space Medicine is conducted throughout NASA by a very small skeleton staff at the headquarters office in Washington and by our various field centers. These centers include the Johnson Space Center in Houston, Texas, the Ames Research Center in Moffett Field, California, the Jet Propulsion Laboratory in Pasadena, California, the Kennedy Space Center in Florida, and the Langley Research Center in Hampton, Virginia. Throughout these various centers, work is conducted in-house by NASA's own staff scientists, physicians, and engineers. In addition, various universities, industries, and other government laboratories perform research that cannot be effectively carried out in-house. At the moment, approximately 50% of the work is performed in-house and 50% is extramural. The area of bioinstrumentation pervades every one of our problem areas. In each, equipment or procedures are being developed that will allow more clinical work to be done in a ground-based or spacecraft setting. Although work of this kind goes on throughout the NASA organization and through its grants and contracts in the community at large, the major thrust of it is concentrated at the Jet Propulsion Laboratory which plays a lead role in this type of research and acts as the lead center in bioinstrumentation for NASA. It is recognized that there is much additional research being pursued in this area which would be potentially valuable to NASA and could, with some stimulation from, be made more applicable to NASA's needs. It is hoped, therefore, that the proceedings of this conference will be used as the basis for developing research strategies to be used as a road map to point the way in which NASA's own sponsored program should proceed over the course of the next three years. Additionally, it is hoped that the conference will highlight additional areas in which NASA should be involved either in-house or through the sponsorship of non-NASA scientists. NASA would also like to get an idea of which areas should be emphasized or perhaps de-emphasized among those that it is currently pursuing. In considering these questions, the discussion should concern itself not so much with whether a particular procedure or piece of equipment would work in a spacecraft, but rather, with whether the procedures that are advocated are at the state-of-the-art or beyond the state-of-the-art and whether they hold promise of giving additional insight into the problems to be confronted as humans venture into space for longer and longer periods of time.

Source record↗

Ultrasound Techniques for Space Applications

Ultrasound has proven to be a safe non-invasive technique for imaging organs and measuring cardiovascular function. It has unique advantages for application to problems with man in space including evaluation of cardiovascular function both in serial studies and during critical operations. In addition, specialized instrumentation may be capable of detecting the onset of decompression sickness during EVA activities. A spatial location and three-dimensional reconstruction system is being developed to improve the accuracy and reproducibility for serial comparative ultrasound studies of cardiovascular function. The three-dimensional method permits the acquisition of ultrasonic images from many views that can be recombined into a single reconstruction of the heart or vasculature. In addition to conventional imaging and monitoring systems, it is sometimes necessary or desirable to develop instrumentation for special purposes. One example of this type of development is the design of a pulsed-Doppler system to monitor cerebral blood flow during critical operations such as re-entry. A second example is the design of a swept-frequency ultrasound system for the detection of bubbles in the circulatory system and/or soft tissues as an early indication of the onset of decompression sickness during EVA activities. This system exploits the resonant properties of bubbles and can detect both fundamental and second harmonic emissions from the insonified region.

Rooney, James A.↗

Space Flight Effects on Intracellular Ions in Sublingual Cells of Non-Human Primates

We have used a novel technique that quantifies minerals and electrolytes from smears of sublingual cells by x-ray microanalysis to monitor metabolic changes in bed rest subjects. Increases in intracellular calcium (Ca), phosphorus (P), and potassium (K) were characteristic of subjects whose exercise regimen was inadequate to maintain calcium metabolism. To test the effects of space flight on intracellular ions, we analyzed cells from 2-4 kg Rhesus monkeys before and after 2 weeks in space or chair restraint (CR). There were increases in sublingual cell Ca, P and K after space flight which paralleled the clinical estimates of metabolic status of the animals and exceeded the levels found during CR on R+11. Increases after 2 weeks CR were 26% in Ca, 6% in P and 29% in K. Species similarity ill responses of intracellular ions to inactivity imposed by bed rest, restraint or microgravity suggest that this innovative non-invasive technique would be a useful in-flight monitor of exercise countermeasures directed toward maintaining calcium balance.

Arnaud, Sara B.↗

Determinants of Long Bone Structural Properties

The objective of our research is to determine whether a non-invasive determination of long bone cross-sectional areal properties using only the mineral component of bone accurately predicts the true structural properties. In this study section properties of a whole long bone were compared using two methods: (1) special analysis of bone densitometry data, and (2) experimental determination of flexural rigidities from bone surface strain measurements during controlled loading.

Cleek, T. M.↗

Assessment of Long Bone Flexural Properties from Bone Densitometry

While bone densitometry is the accepted non-invasive method of quantifying bone mineral content in bones, its assessment of bone structural properties is less well understood. The objective of our current work is to compare cross-section shape or areal properties of long bones computed from densitometry data with cross-section flexural properties obtained from surface strain measurements.

Whalen, Robert↗

Performance Testing

Systems Technology, Inc., Hawthorne, CA, developed an electronic Critical Tracking Task (CTT) system that analyzes and rates a subject's visual/motor responses for Ames Research Center. Originally applied to measuring the effects of long term confinement in the mid 1960's, the CTT system is now marketed as FACTOR 1000 by Performance Factors, Inc. Alameda, CA, under a licensing agreement with Systems Technology. The system is a non-invasive, self-administered test that takes less than a minute and detects impairment from a broad range of causes, including stress, fatigue, illness, drugs, or alcohol. It is used daily by Old Town Trolley Tours, San Diego, CA, to assess each driver's physical coordination skills prior to the start of each shift. FACTOR 1000 reduces liabilities and costs related to accidents, and costs less than one dollar per day per employee. Performance Factors is now BioFactors, Inc.

Source record↗

Structural Diagnosis

All over the world, officials charged with preserving historical structures are faced with a problem of environmental contamination of building materials that cause structural deterioration. First requisite for preserving the structure is identification of the nature of contaminants. A "non-invasive"technique based on space technology has been developed and tested. It employs a neutron source and a gamma ray detector. Placed on one side of the wall to be examined, the source fires neutrons created by the decay of a radioactive isotope. As they pass through the wall, the neutrons collide with atoms and the atoms, depending on their type, emit various kinds of gamma rays. These rays are identified by the gamma ray detector on the other side of the wall. Energy of the rays shows the kind of element present. The intensity level indicates the quantity. Composition of the contaminants within the walls is determined by a multichannel analyzer.

Source record↗

Monitoring the state of the human airways by analysis of respiratory sound

A mechanism whereby sound is generated by the motion of vortices in the human lung is described. This mechanism is believed to be responsible for most of the sound which is generated both on inspiration and expiration in normal lungs. Mathematical expressions for the frequencies of sound generated, which depend only upon the axial flow velocity and diameters of the bronchi, are derived. This theory allows the location within the bronchial tree from which particular sounds emanate to be determined. Redistribution of pulmonary blood volume following transition from Earth gravity to the weightless state probably alters the caliber of certain airways and doubtless alters sound transmission properties of the lung. We believe that these changes can be monitored effectively and non-invasively by spectral analysis of pulmonary sound.

Lung/anatomy & histology/physiology↗

bpshape wk4: a computer program that implements a physiological model for analyzing the shape of blood pressure waveforms

We describe the theory and computer implementation of a newly-derived mathematical model for analyzing the shape of blood pressure waveforms. Input to the program consists of an ECG signal, plus a single continuous channel of peripheral blood pressure, which is often obtained invasively from an indwelling catheter during intensive-care monitoring or non-invasively from a tonometer. Output from the program includes a set of parameter estimates, made for every heart beat. Parameters of the model can be interpreted in terms of the capacitance of large arteries, the capacitance of peripheral arteries, the inertance of blood flow, the peripheral resistance, and arterial pressure due to basal vascular tone. Aortic flow due to contraction of the left ventricle is represented by a forcing function in the form of a descending ramp, the area under which represents the stroke volume. Differential equations describing the model are solved by the method of Laplace transforms, permitting rapid parameter estimation by the Levenberg-Marquardt algorithm. Parameter estimates and their confidence intervals are given in six examples, which are chosen to represent a variety of pressure waveforms that are observed during intensive-care monitoring. The examples demonstrate that some of the parameters may fluctuate markedly from beat to beat. Our program will find application in projects that are intended to correlate the details of the blood pressure waveform with other physiological variables, pathological conditions, and the effects of interventions.

Non-NASA Center↗

Determinants of the mechanical properties of bones

The mechanical properties of bones are governed by the same principles as those of man-made load-bearing structures, but the organism is able to adapt its bone structure to changes in skeletal loading. In this overview of the determinants of the strength and stiffness of bone, a continuum approach has been taken, in which the behavior of a macroscopic structure depends on its shape and size, and on the mechanical properties of the material within. The latter are assumed to depend on the composition (porosity and mineralization) and organization (trabecular or cortical bone architecture, collagen fiber orientation, fatigue damage) of the bone. The effects of each of these factors are reviewed. Also, the possible means of non-invasively estimating the strength or other mechanical properties of a bone are reviewed, including quantitative computed tomography, photon absorptiometry, and ultrasonic measurements. The best estimates of strength have been obtained with photon absorptiometry and computed tomography, which at best are capable of accounting for 90% of the strength variability in a simple in vitro test, but results from different laboratories have been highly variable.

Non-NASA Center↗

Pharmacology in space. Part 2. Controlling motion sickness

In this second article in the two-part series on pharmacology in space, Claire Lathers and colleagues discuss the pharmacology of drugs used to control motion sickness in space and note that the pharmacology of the 'ideal' agent has yet to be worked out. That motion sickness may impair the pharmacological action of a drug by interfering with its absorption and distribution because of alteration of physiology is a problem unique to pharmacology in space. The authors comment on the problem of designing suitable ground-based studies to evaluate the pharmacological effect of drugs to be used in space and discuss the use of salivary samples collected during space flight to allow pharmacokinetic evaluations necessary for non-invasive clinical drug monitoring.

STS Shuttle Project↗