Search NASA⌕ Search

SEARCH · Search NASA

Results for “noninvasive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Noninvasive stress testing - Methodology for elimination of the phonocardiogram

Measurement by systolic time intervals (STI) of cardiac responses requires extremely careful recording during actual stress test performance. Previous work indicated no significant changes in the pulse transmission time (PTT) during exercise and other challenges. Since external STI depend on the carotid pulse offset by the PTT as an aortic curve equivalent, stable PTT implies that timing of the carotid upstroke and the carotid incisura would respectively track the pre-ejection period and the aortic incisura. In ten subjects, STIs were recorded at supine rest, sitting, standing, during prompt and sustained squatting and during isometric and dynamic exercise. The results demonstrated the tracking of both points. Coefficients of correlation and of determination were uniformly high for all challenges except isometric handgrip (IHG). Since left ventricular ejection time is obtained directly from the pulse curve, with the exception of IHG, STI responses during stress testing can be measured without a phonocardiogram.

Spodick, D. H.↗

Noninvasive measures of bone bending rigidity in the monkey /M. nemestrina/

The in vivo bending rigidity and bone mineral content of monkey ulnae and tibiae were measured. Bending rigidity in the anteroposterior plane was measured by an impedance probe technique. Forced vibrations of the bones were induced with an electromechanical shaker, and force and velocity at the driving point were determined. The responses over the range of 100-250 Hz were utilized to compute the bending rigidity. Bone mineral content in the cross section was determined by a photon absorption technique. Seventeen male monkeys (Macaca nemestrina) weighing 6-14 kg were evaluated. Bending rigidity was correlated with the mineral content of the cross section, with a correlation coefficient of 0.899. Two monkeys were evaluated during prolonged hypodynamic restraint. Restraint produced regional losses of bone most obviously in the proximal tibia. The local bone mineral content declines 17 to 24% and the average bending rigidity declines 12 to 22%. Changes in bones leading to a reduction in mineral content and stiffness are discussed.

Young, D. R.↗

Noninvasive Fluid Level Sensor for Organometallic Sources

Two ultrasonic methods available for measuring level of organometallic liquid in stainless-steel (or other homogeneous solid) container. Methods require no disassembly or weighing of container. Commercially available ultrasonic flaw detectors, some of which have digital readouts and computer interfaces, used in techniques. Both methods used in crystal growth to determine level of liquids contained in sealed, opaque containers.

Gerdes, W.↗

Remote gate capacitance-voltage studies for noninvasive surface characterization

A measurement technique has been developed which allows noncontact capacitance-voltage measurements to be made using a gate electrode located remote from the semiconductor surface under study. With gate electrodes about 0.5 mm in diameter and gate to semiconductor separations of about 1500 A, it was possible to generate data entirely comparable to that obtained with integrated MIS structures but with the advantage that there was access directly to the free-semiconductor surface. This technique was applied to bulk single-crystal Si and InP samples.

Chang, R. R.↗

Cardiovascular adaptation to O-G (Experiment 294) - Instrumentation for invasive and noninvasive studies

Many astronauts returning from space have difficulties regulating blood pressure, some to the point of fainting during quiet standing. Experiment 294 was designed to study this and other cardiovascular effects of adaptation to microgravity and to understand the mechanisms behind it. To accomplish this several cardiovascular variables had to be measured accurately. Heart rate, blood pressure, cardiac output (blood pumped by the heart each minute), stroke volume (blood pumped by the heart with each beat), limb flow, limb compliance, heart size and central venous pressure all had to been recorded during various stresses to understand fully the adaptation to space and the readaptation to earth's gravity. Numerous pieces of equipment were used. Some were purpose-built for the Spacelab mission and others were derived from commercial hardware. Developing spaceflight hardware is challenging and costly, but can lead to significant new information in the unique environment of space.

Buckey, Jay C.↗

Measuring Intracranial Pressure And Volume Noninvasively

Ultrasonic technique eliminates need to drill into brain cavity. Intracranial dynamics instrument probes cranium ultrasonically to obtain data for determination of intracranial pressure (ICP) and pressure-volume index (PVI). Instrument determines sensitivity of skull to changes in pressure and by use of mechanical device to exert external calibrated pressure on skull. By monitoring volume of blood flowing into jugular vein, one determines change of volume of blood in cranial system. By measuring response of skull to increasing pressure (where pressure increased by tilting patient known amount) and by using cranial blood pressure, one determines intial pressure in cerebrospinal fluid. Once PVI determined, ICP determined.

Cantrell, John H.↗

Noninvasive Determination of Bone Mechanical Properties Using Vibration Response: A Refined Model and Validation in vivo

Accurate non-invasive mechanical measurement of long bones is made difficult by the masking effect of surrounding soft tissues. Mechanical response tissue analysis (MRTA) offers a method for separating the effects of the soft tissue and bone; however, a direct validation has been lacking. A theoretical analysis of wave propagation through the compressed tissue revealed a strong mass effect dependent on the relative accelerations of the probe and bone. The previous mathematical model of the bone and overlying tissue system was reconfigured to incorporate the theoretical finding. This newer model (six-parameter) was used to interpret results using MRTA to determine bone cross-sectional bending stiffness, EI(sub MRTA). The relationship between EI(sub MRTA) and theoretical EI values for padded aluminum rods was R(sup 2) = 0.999. A biological validation followed using monkey tibias. Each bone was tested in vivo with the MRTA instrument. Postmortem, the same tibias were excised and tested to failure in three-point bending to determine EI(sub 3-PT) and maximum load. Diaphyseal bone mineral density (BMD) measurements were also made. The relationship between EI(sub 3-PT) and in vivo EI(sub MRTA) using the six-parameter model is strong (R(sup 2) = 0.947) and better than that using the older model (R(sup 2) = 0.645). EI(sub MRTA) and BMD are also highly correlated (R(sup 2) = 0.853). MRTA measurements in vivo and BMD ex vivo are both good predictors of scaled maximum strength (R(sup 2) = 0.915 and R(sup 2) = 0.894, respectively). This is the first biological validation of a non- invasive mechanical measurement of bone by comparison to actual values. The MRTA technique has potential clinical value for assessing long-bone mechanical properties.

Roberts, S. G.↗

Noninvasive Determination of Bone Mechanical Properties using Vibration Response: A Refined Model and Validation in vivo

Accurate non-invasive mechanical measurement of long bones is made difficult by the masking effect of surrounding soft tissues. Mechanical Response Tissue Analysis (MRTA) offers a method for separating the effects of the soft tissue and bone; however, a direct validation has been lacking. A theoretical analysis of wave propagation through the compressed tissue revealed a strong mass effect dependent on the relative accelerations of the probe and bone. The previous mathematical model of the bone and overlying tissue system was reconfigured to incorporate the theoretical finding. This newer model (six-parameter) was used to interpret results using MRTA to determine bone cross-sectional bending stiffness, EI(sub MRTA). The relationship between EI(MRTA) and theoretical EI values for padded aluminum rods was R(exp 2) = 0.999. A biological validation followed using monkey tibias. Each bone was tested in vivo with the MRTA instrument. Postmortem, the same tibias were excised and tested to failure in three-point bending to determine EI(sub 3-PT) and maximum load. Diaphyseal Bone Mineral Density (BMD) measurements were also made. The relationship between E(sub 3-PT) and in vivo EI(sub MRTA) using the six-parameter model is strong (R(exp 2) = 0.947) and better than that using the older model (R(exp 2) = 0.645). EI(MRTA) and BMD are also highly correlated (R(exp 2) = 0.853). MRTA measurements in vivo and BMD ex vivo are both good predictors of scaled maximum strength (R(exp 2) = 0.915 and R(exp 2) = 0.894, respectively). This is the first biological validation of a non-invasive mechanical measurement of bone by comparison to actual values. The MRTA technique has potential clinical value for assessing long-bone mechanical properties.

Roberts, S. G.↗

Noninvasive Investigation of Bone Adaptation in Humans Cumulative Daily Mechanical Loading

Our Research Objective is to measure the spatial distribution of bone mass throughout the entire internal volume of a bone such as the human calcaneus or heel bone. Currently, x-ray computed tomography (CT) is the only practical three-dimensional imaging technology capable of measuring bone density within small contiguous volumetric regions of a bone. spectrum of energies in the x-ray beam producing the image. We have developed a computational method of correcting these errors, provided the x-ray spectrum is known or measured (Yan et al., 2000). Monitoring serial changes in volumetric bone density with age, disuse, exercise or A CT image contains measurement errors in bone density caused by the broad drug therapy also requires accurate image registration.

Whalen, Robert T.↗

Noninvasive assessment of mitral inertness: clinical results with numerical model validation

Inertial forces (Mdv/dt) are a significant component of transmitral flow, but cannot be measured with Doppler echo. We validated a method of estimating Mdv/dt. Ten patients had a dual sensor transmitral (TM) catheter placed during cardiac surgery. Doppler and 2D echo was performed while acquiring LA and LV pressures. Mdv/dt was determined from the Bernoulli equation using Doppler velocities and TM gradients. Results were compared with numerical modeling. TM gradients (range: 1.04-14.24 mmHg) consisted of 74.0 +/- 11.0% inertial forcers (range: 0.6-12.9 mmHg). Multivariate analysis predicted Mdv/dt = -4.171(S/D (RATIO)) + 0.063(LAvolume-max) + 5. Using this equation, a strong relationship was obtained for the clinical dataset (y=0.98x - 0.045, r=0.90) and the results of numerical modeling (y=0.96x - 0.16, r=0.84). TM gradients are mainly inertial and, as validated by modeling, can be estimated with echocardiography.

NASA Discipline Cardiopulmonary↗

Noninvasive, near infrared spectroscopic-measured muscle pH and PO2 indicate tissue perfusion for cardiac surgical patients undergoing cardiopulmonary bypass

OBJECTIVE: To determine whether near infrared spectroscopic measurement of tissue pH and Po2 has sufficient accuracy to assess variation in tissue perfusion resulting from changes in blood pressure and metabolic demand during cardiopulmonary bypass. DESIGN: Prospective clinical study. SETTING: Academic medical center. SUBJECTS: Eighteen elective cardiac surgical patients. INTERVENTION: Cardiac surgery under cardiopulmonary bypass. MEASUREMENTS AND MAIN RESULTS: A near infrared spectroscopic fiber optic probe was placed over the hypothenar eminence. Reference Po2 and pH sensors were inserted in the abductor digiti minimi (V). Data were collected every 30 secs during surgery and for 6 hrs following cardiopulmonary bypass. Calibration equations developed from one third of the data were used with the remaining data to investigate sensitivity of the near infrared spectroscopic measurement to physiologic changes resulting from cardiopulmonary bypass. Near infrared spectroscopic and reference pH and Po2 measurements were compared for each subject using standard error of prediction. Near infrared spectroscopic pH and Po2 at baseline were compared with values during cardiopulmonary bypass just before rewarming commenced (hypotensive, hypothermic), after rewarming (hypotensive, normothermic) just before discontinuation of cardiopulmonary bypass, and at 6 hrs following cardiopulmonary bypass (normotensive, normothermic) using mixed-model analysis of variance. Near infrared spectroscopic pH and Po2 were well correlated with the invasive measurement of pH (R2 =.84) and Po2 (R 2 =.66) with an average standard error of prediction of 0.022 +/- 0.008 pH units and 6 +/- 3 mm Hg, respectively. The average difference between the invasive and near infrared spectroscopic measurement was near zero for both the pH and Po2 measurements. Near infrared spectroscopic Po2 significantly decreased 50% on initiation of cardiopulmonary bypass and remained depressed throughout the bypass and monitored intensive care period. Near infrared spectroscopic pH decreased significantly during cardiopulmonary bypass, decreased significantly during rewarming, and remained depressed 6 hrs after cardiopulmonary bypass. Diabetic patients responded differently than nondiabetic subjects to cardiopulmonary bypass, with lower muscle pH values (p =.02). CONCLUSIONS: Near infrared spectroscopic-measured muscle pH and Po2 are sensitive to changes in tissue perfusion during cardiopulmonary bypass.

Non-NASA Center↗

Signal averaging technique for noninvasive recording of late potentials in patients with coronary artery disease

An advanced non invasive signal averaging technique was used to detect late potentials in two groups of patients: Group A (24 patients) with coronary artery disease (CAD) and without sustained ventricular tachycardia (VT) and Group B (8 patients) with CAD and sustained VT. Recorded analog data were digitized and aligned using a cross correlation function with fast Fourier transform schema, averaged and band pass filtered between 60 and 200 Hz with a non-recursive digital filter. Averaged filtered waveforms were analyzed by computer program for 3 parameters: (1) filtered QRS (fQRS) duration (2) interval between the peak of the R wave peak and the end of fQRS (R-LP) (3) RMS value of last 40 msec of fQRS (RMS). Significant change was found between Groups A and B in fQRS (101 -/+ 13 msec vs 123 -/+ 15 msec; p < .0005) and in R-LP vs 52 -/+ 11 msec vs 71-/+18 msec, p <.002). We conclude that (1) the use of a cross correlation triggering method and non-recursive digital filter enables a reliable recording of late potentials from the body surface; (2) fQRS and R-LP durations are sensitive indicators of CAD patients susceptible to VT.

NASA Discipline Cardiopulmonary↗

Ocular Blood Flow Measured Noninvasively in Zero Gravity

In spaceflight or a reduced-gravity environment, bodily fluids shift to the upper extremities of the body. The pressure inside the eye, or intraocular pressure, changes significantly. A significant number of astronauts report changes in visual acuity during orbital flight. To date this remains of unknown etiology. Could choroidal engorgement be the primary mechanism and a change in the curvature or shape of the cornea or lens be the secondary mechanism for this change in visual acuity? Perfused blood flow in the dense meshwork of capillaries of the choroidal tissue (see the preceding illustration) provides necessary nutrients to the outer layers of the retina (photoreceptors) to keep it healthy and maintain good vision. Unlike the vascular system, the choroid has no baroreceptors to autoregulate fluid shifts, so it can remain engorged, pushing the macula forward and causing a hyperopic (farsighted) shift of the eye. Experiments by researchers at the NASA Glenn Research Center could help answer this question and facilitate planning for long-duration missions. We are investigating the effects of zero gravity on the choroidal blood flow of volunteer subjects. This pilot project plans to determine if choroidal blood flow is autoregulated in a reduced-gravity environment.

Ansari, Rafat R.↗

Noninvasive 3D Visualization of Defects and Crack Propagation in Layered Foam Structures by Phase Contrast Microimaging

Applications of polymeric foams in our modern society continue to grow because of their light weight, high strength, excellent thermal and mechanical insulation, and the ease of engineering. Among others, closed-cell foam has been structurally used for thermally insulating the shuttle external tank. However, internal defects of the foams were difficult to observe non-invasively due to limited sensitivity to the low-density structures possessed by traditional imaging tools such as computed X-ray tomography By combining phase contrast X-ray imaging with pressure loading, we succeeded in precisely mapping intact cellular structure and defects inside the bulk of layered foam and visualizing its subsequent response to the pressure in three-dimensional space. The work demonstrated a powerfir1 approach for yielding insight into underlying problems in lightweight cellular materials otherwise unobtainable.

Hu, Z. W.↗