Propagation and absorption of high-intensity femtosecond laser radiation in diamond

Femtosecond interferometry has been used to experimentally study the photoexcitation of the electron subsystem of diamond exposed to femtosecond laser pulses of intensity 10{sup 11} to 10{sup 14} W cm{sup -2}. The carrier concentration has been determined as a function of incident intensity for three harmonics of a Ti : sapphire laser (800, 400 and 266 nm). The results demonstrate that, in a wide range of laser fluences (up to those resulting in surface and bulk graphitisation), a well-defined multiphoton absorption prevails. We have estimated nonlinear absorption coefficients for pulsed radiation at λ = 800 nm (four-photon transition) and at 400 and 266 nm (indirect and direct two-photon transitions, respectively). It has also been shown that, at any considerable path length of a femtosecond pulse in diamond (tens of microns or longer), the laser beam experiences a severe nonlinear transformation, determining the amount of energy absorbed by the lattice, which is important for the development of technology for diamond photostructuring by ultrashort pulses. The competition between wave packet self-focusing and the plasma defocusing effect is examined as a major mechanism governing the propagation of intense laser pulses in diamond. (interaction of laser radiation with matter. laser plasma)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Directionally asymmetric nonlinear optics in ferrorotational MnTiO 3

Ferrorotationally ordered materials possess a planar chiral lattice of electric dipoles that are a promising platform for exhibiting directionally asymmetric response functions. A key characteristic of such order is that enantiomorph conversion occurs when the solid is flipped by 180° about an in-plane axis. Using second-harmonic interferometry, we show here that when circularly polarized light is incident on MnTiO 3 , the generated harmonic intensity depends on whether the incident light is parallel or antiparallel to the ferrorotational axis. For a particular photon helicity, constructive interference occurs in one direction while destructive interference occurs in the other. Here, our observations represent a fundamentally new optical effect, associated with circularly polarized light in ferrorotational solids, that is distinct from conventional optical activity observed in three-dimensional chiral and Faraday media.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design, Fabrication, and Testing of SMA Enabled Adaptive Chevrons for Jet Noise Reduction

This study presents the status and results from an effort to design, fabricate, and test an adaptive jet engine chevron concept based upon embedding shape memory alloy (SMA) actuators in a composite laminate, termed a SMA hybrid composite (SMAHC). The approach for fabricating the adaptive SMAHC chevrons involves embedding prestrained Nitinol actuators on one side of the mid-plane of the composite laminate such that thermal excitation generates a thermal moment and deflects the structure. A glass-epoxy pre-preg/Nitinol ribbon material system and a vacuum hot press consolidation approach are employed. A versatile test system for control and measurement of the chevron deflection performance is described. Projection moire interferometry (PMI) is used for global deformation measurement and infrared (IR) thermography is used for 2-D temperature measurement and feedback control. A recently commercialized constitutive model for SMA and SMAHC materials is used in the finite element code ABAQUS to perform nonlinear static analysis of the chevron prototypes. Excellent agreement is achieved between the predicted and measured chevron deflection performance, thereby validating the design tool. Although the performance results presented in this paper fall short of the requirement, the concept is proven and an approach for achieving the performance objectives is evident.

Turner, Travis L.↗

Interferometer for Measuring Displacement to Within 20 pm

An optical heterodyne interferometer that can be used to measure linear displacements with an error <=20 pm has been developed. The remarkable accuracy of this interferometer is achieved through a design that includes (1) a wavefront split that reduces (relative to amplitude splits used in other interferometers) self interference and (2) a common-optical-path configuration that affords common-mode cancellation of the interference effects of thermal-expansion changes in optical-path lengths. The most popular method of displacement- measuring interferometry involves two beams, the polarizations of which are meant to be kept orthogonal upstream of the final interference location, where the difference between the phases of the two beams is measured. Polarization leakages (deviations from the desired perfect orthogonality) contaminate the phase measurement with periodic nonlinear errors. In commercial interferometers, these phase-measurement errors result in displacement errors in the approximate range of 1 to 10 nm. Moreover, because prior interferometers lack compensation for thermal-expansion changes in optical-path lengths, they are subject to additional displacement errors characterized by a temperature sensitivity of about 100 nm/K. Because the present interferometer does not utilize polarization in the separation and combination of the two interfering beams and because of the common-mode cancellation of thermal-expansion effects, the periodic nonlinear errors and the sensitivity to temperature changes are much smaller than in other interferometers

Zhao, Feng↗

Single-shot observation of nonlinear pulse splitting in a Kerr medium

We report single-shot, time-resolved observation of self-steepening and temporal splitting of near-infrared, 50 fs, micro-joule pulses propagating nonlinearly in flint (SF11) glass. A coherent, smooth-profiled, 60-nm-bandwidth probe pulse that propagated obliquely to the main pulse through the Kerr medium recorded a time sequence of longitudinal projections of the main pulse’s induced refractive index profile in the form of a phase-shift “streak,” in which frequency–domain interferometry recovered with ∼10 fs temporal resolution. A three-dimensional simulation based on a unidirectional pulse propagation equation reproduced observed pulse profiles.

Chang, Yen-Yu↗

Effect of injected flux and current temporal phasing on self-organization in the HIT-SI3 experiment

The HIT-SI3 device at the University of Washington uses three oscillating inductive helicity injectors to form and sustain spheromak plasma equilibria. By adjusting the temporal phase of the injector waveforms with respect to each other, the toroidal spectrum of the imposed perturbations can be controlled. Using a recently implemented GPU-based control system, the available mode spectra were explored experimentally by scanning the space of relative injector phasing. In this space, significant variation in the toroidal mode spectrum ($n$ = 1, 2, 3) of the perturbations was observed. Additionally, variation in characteristics of driven equilibria was also observed, including a ≈ $30$% range in toroidal current gain ($I$ $Φ$ / $I$ $Inj$ ). Experimental results are compared with both a composite-equilibria and nonlinear dynamic model, including extended MHD simulations using the NIMROD code and composite Taylor state equilibria computed using the PSI-Tet code. In conclusion, qualitative agreement is seen with the nonlinear models, but not with composite-equilibria models, suggesting the use of nonlinear models to better capture observed plasma dynamics and provide predictive use for future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Astrophysical data analysis with information field theory

Non-parametric imaging and data analysis in astrophysics and cosmology can be addressed by information field theory (IFT), a means of Bayesian, data based inference on spatially distributed signal fields. IFT is a statistical field theory, which permits the construction of optimal signal recovery algorithms. It exploits spatial correlations of the signal fields even for nonlinear and non-Gaussian signal inference problems. The alleviation of a perception threshold for recovering signals of unknown correlation structure by using IFT will be discussed in particular as well as a novel improvement on instrumental self-calibration schemes. IFT can be applied to many areas. Here, applications in in cosmology (cosmic microwave background, large-scale structure) and astrophysics (galactic magnetism, radio interferometry) are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new fast two-color interferometer at Alcator C-Mod for turbulence measurements and comparison with phase contrast imaging

Accurately predicting the turbulent transport properties of magnetically confined plasmas is a major challenge of fusion energy research. Validation of transport models is typically done by applying so-called “synthetic diagnostics” to the output of nonlinear gyrokinetic simulations, and the results are compared to experimental data. As part of the validation process, comparing two independent turbulence measurements to each other provides the opportunity to test the synthetic diagnostics themselves; a step which is rarely possible due to limited availability of redundant fluctuation measurements on magnetic confinement experiments. At Alcator C-Mod, phase-contrast imaging (PCI) is a commonly used turbulence diagnostic. PCI measures line-integrated electron density fluctuations with high sensitivity and wavenumber resolution (1.6 cm{sup −1}≲|k{sub R}|≲11 cm{sup −1}). A new fast two-color interferometry (FTCI) diagnostic on the Alcator C-Mod tokamak measures long-wavelength (|k{sub R}|≲3.0 cm{sup −1}) line-integrated electron density fluctuations. Measurements of coherent and broadband fluctuations made by PCI and FTCI are compared here for the first time. Good quantitative agreement is found between the two measurements. This provides experimental validation of the low-wavenumber region of the PCI calibration, and also helps validate the low-wavenumber portions of the synthetic PCI diagnostic that has been used in gyrokinetic model validation work in the past. We discuss possibilities to upgrade FTCI, so that a similar comparison could be done at higher wavenumbers in the future.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear Photoemission Electron Micrographs of Plasmonic Nanoholes in Gold Thin Films

Nonlinear photoemission electron microscopy of isolated nanoholes in gold thin films map propagating surface plasmon polaritons (SPPs) launched from the lithographically patterned plasmonic structures. A damped sinusoidal elongated ring-like photoemission beat pattern is observed from the nanoholes, following low angle of incidence irradiation of these structures with sub-15 fs 780 nm laser pulses. A notable agreement between finite difference time domain simulations and experiment corroborates our assignment of the observed photoemission patterns to SPPs launched from isolated nanoholes and probed through nonlinear photoemission. We also demonstrate how the efficiency of coupling light waves into isolated plasmonic holes can be tuned by varying hole diameter. In this regard, a simple intuitive geometrical model, which accounts for the observed and simulated diameter dependent plasmonic response, is proposed. Overall, this study paves the way for designing nanohole assemblies where optical coupling and subsequent plasmon propagation can be rationally controlled through 2D SPP interferometry

Environmental Molecular Sciences Laboratory↗

White-light Interferometry using a Channeled Spectrum: II. Calibration Methods, Numerical and Experimental Results

In the companion paper, [Appl. Opt. 46, 5853 (2007)] a highly accurate white light interference model was developed from just a few key parameters characterized in terms of various moments of the source and instrument transmission function. We develop and implement the end-to-end process of calibrating these moment parameters together with the differential dispersion of the instrument and applying them to the algorithms developed in the companion paper. The calibration procedure developed herein is based on first obtaining the standard monochromatic parameters at the pixel level: wavenumber, phase, intensity, and visibility parameters via a nonlinear least-squares procedure that exploits the structure of the model. The pixel level parameters are then combined to obtain the required 'global' moment and dispersion parameters. The process is applied to both simulated scenarios of astrometric observations and to data from the microarcsecond metrology testbed (MAM), an interferometer testbed that has played a prominent role in the development of this technology.

phase correction↗

Platform Precision Autopilot Overview and Flight Test Results

The Platform Precision Autopilot is an instrument landing system interfaced autopilot system, developed to enable an aircraft to repeatedly fly nearly the same trajectory hours, days, or weeks later. The Platform Precision Autopilot uses a novel design to interface with a NASA Gulfstream III jet by imitating the output of an instrument landing system approach. This technique minimizes, as much as possible, modifications to the baseline Gulfstream III jet and retains the safety features of the aircraft autopilot. The Platform Precision Autopilot requirement is to fly within a 5-m (16.4-ft) radius tube for distances to 200 km (108 nmi) in the presence of light turbulence for at least 90 percent of the time. This capability allows precise repeat-pass interferometry for the Uninhabited Aerial Vehicle Synthetic Aperture Radar program, whose primary objective is to develop a miniaturized, polarimetric, L-band synthetic aperture radar. Precise navigation is achieved using an accurate differential global positioning system developed by the Jet Propulsion Laboratory. Flight-testing has demonstrated the ability of the Platform Precision Autopilot to control the aircraft within the specified tolerance greater than 90 percent of the time in the presence of aircraft system noise and nonlinearities, constant pilot throttle adjustments, and light turbulence.

Lin, V.↗

Platform Precision Autopilot Overview and Mission Performance

The Platform Precision Autopilot is an instrument landing system-interfaced autopilot system, developed to enable an aircraft to repeatedly fly nearly the same trajectory hours, days, or weeks later. The Platform Precision Autopilot uses a novel design to interface with a NASA Gulfstream III jet by imitating the output of an instrument landing system approach. This technique minimizes, as much as possible, modifications to the baseline Gulfstream III jet and retains the safety features of the aircraft autopilot. The Platform Precision Autopilot requirement is to fly within a 5-m (16.4-ft) radius tube for distances to 200 km (108 nmi) in the presence of light turbulence for at least 90 percent of the time. This capability allows precise repeat-pass interferometry for the Unmanned Aerial Vehicle Synthetic Aperture Radar program, whose primary objective is to develop a miniaturized, polarimetric, L-band synthetic aperture radar. Precise navigation is achieved using an accurate differential global positioning system developed by the Jet Propulsion Laboratory. Flight-testing has demonstrated the ability of the Platform Precision Autopilot to control the aircraft within the specified tolerance greater than 90 percent of the time in the presence of aircraft system noise and nonlinearities, constant pilot throttle adjustments, and light turbulence.

Strovers, Brian K.↗

Microwave Imaging Reflectometry for the study of Edge Harmonic Oscillations on DIII-D [Microwave Imaging Reflectometry (MIR) for the study of Edge Harmonic Oscillations (EHOs) on DIII-D]

Quiescent H-mode (QH) is an ELM free mode of operation in which edge-localized harmonic oscillations (EHOs) are believed to enhance particle transport, thereby stabilizing ELMs and preventing damage to the divertor and plasma facing components. Microwave Imaging Reflectometer (MIR) enabling direct comparison between the measured and simulated 2D images of density fluctuations near the edge can determine the 2D structure of density oscillation which can help to explain the physics behind EHO modes. MIR data sometimes indicates a counter-propagation between higher (n>1) and dominant (n=1) harmonics of coherent EHOs in the steep gradient regions of the pedestal. To preclude diagnostic artifacts, we have performed forward modeling that includes possible optical misalignments to show that offsets between transmitting and receiving antennas do not account for this feature. We have also simulated the non-uniform rotation of the EHO structure, which induces multiple harmonics that are properly characterized in the synthetic diagnostic. Excluding these possible explanations for the data, the counter-propagation observed in MIR data, which is not corroborated by external Mirnov coil array measurements, may be due to subtleties of the eigenmode structure, such as an inversion radius consistent with a magnetic island. Similar effects are observed in analysis of internal ECE-Imaging and BES data. Furthermore, the identification of a non-ideal structure motivates further exploration of nonlinear models of this instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrafast dynamic response of single-crystal β -HMX (octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine)

Here, we report experimental and computational studies of shock wave dynamics in single-crystal β-HMX on an ultrafast time scale. Here, a laser-based compression drive (~1 ns in duration; stresses of up to ~40 GPa) is used to propagate shock waves normal to the (110) and (010) lattice planes. Ultrafast time-domain interferometry measurements reveal distinct, time-dependent relationships between the shock wave velocity and particle velocity for each crystal orientation, which suggest evolving physical processes on a sub-nanosecond time scale. To help interpret the experimental data, elastic shock wave response was simulated using a finite-strain model of crystal thermoelasticity. At early propagation times (<500 ps), the model is in agreement with the data, which indicates that the mechanical response is dominated by thermoelastic deformation. The model agreement depends on the inclusion of nonlinear elastic effects in both the spherical and deviatoric stress-strain responses. This is achieved by employing an equation-of-state and a pressure-dependent stiffness tensor, which was computed via atomistic simulation. At later times (>500 ps), the crystal samples exhibit signatures of inelastic deformation, structural phase transformation, or chemical reaction, depending on the direction of wave propagation.

36 MATERIALS SCIENCE↗

A Simple Approach of CCD Camera Calibration for Optical Diagnostics Instrumentation

Solid State array sensors are ubiquitous nowadays for obtaining gross field images in numerous scientific and engineering applications including optical diagnostics and instrumentation. Linear responses of these sensors are often required as in interferometry, light scattering and attenuation measurements, and photometry. In most applications, the linearity is usually taken to be granted without thorough quantitative assessment or correction through calibration. Upper-grade CCD cameras of high price may offer better linearity: however, they also require linearity checking and correction if necessary. Intermediate- or low-grade CCD cameras are more likely to need calibration for linearity . Here, we present two very simple approaches: one for quickly checking camera linearity without any additional setup and one for precisely correcting nonlinear sensor responses. It is believed that after calibration, those sensors of intermediate or low grade can function as effectively as their expensive counterpart.

Cha, Soyoung Stephen↗

Information transfer as a framework for optimized phase imaging

In order to efficiently image a non-absorbing sample (a phase object), dedicated phase contrast optics are required. Typically, these optics are designed with the assumption that the sample is weakly scattering, implying a linear relation between a sample’s phase and its transmission function. In the strongly scattering, nonlinear case, the standard optics are ineffective, and the transfer functions used to characterize them are uninformative. We use the Fisher information (FI) to assess the efficiency of various phase imaging schemes and to calculate an information transfer function (ITF). We show that a generalized version of Zernike phase contrast is efficient given sufficient prior knowledge of the sample. We show that with no prior knowledge, a random sensing measurement yields a significant fraction of the available information. Finally, we introduce a generalized approach to common path interferometry that can be optimized to prioritize sensitivity to particular sample features. Each of these measurements can be performed using Fourier lenses and phase masks.

Koppell, Stewart↗

EXPLORING INTERFEROMETRY DIAGNOSTICS FOR OPTICAL STOCHASTIC COOLING AT FAST/IOTA

Optical Stochastic Cooling (OSC) is an advanced beam-cooling technique that will advance the traditional stochastic cooling. This method leverages optical radiation and high-precision feedback to cool the particles more efficiently than traditional stochastic methods by more than three orders of magnitude. As such, it is an enabler for the development of next generation discovery science machines at the frontiers of energy and intensity. This paper focuses on the development of the second phase of OSC and improving extreme beam cooling techniques in accelerators. The goal was to build and characterize a Mach-Zehnder Interferometer (MZI) in the FAST laser lab using known glass plates thickness which will allow future measurements of unknown phase change due to nonlinear amplification processes.

Teriba, Folashade↗

Electronic heterodyne moire deflectometry: A method for transient and three dimensional density fields measurements

Effects of diffraction and nonlinear photographic emulsion characteristics on the performance of deferred electronic heterodyne moire deflectometry are investigated. The deferred deflectometry is used for measurements of nonsteady phase objects where it is difficult to complete the analysis of the field in real time. The sensitivity, accuracy and resolution of the system are calculated and it is shown that they are weakly affected by diffraction and by nonlinear recording. The feactures of the system are significantly improved compared with the conventional deferred intensity moire technique, and are comparable with the online heterodyne moire. The system was evaluated experimentally by deferred measurements of the refractive index gradients of a weak phase object consisting of a large KD*P crystal. This was done by photographing the phase object through a Ronchi grating and analyzing the tranparency with the electronic heterodyne readout system. The results are compared with the measurements performed on the same phase object with online heterodyne moire deflectometry and with heterodyne holographic interferometry methods. Some practical considerations for system improvement are discussed.

Stricker, Josef↗