Search NASA⌕ Search

SEARCH · Search NASA

Results for “nonlinear interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

83 records · Page 5

Second Harmonic Generation Electric Field Triplet Interferometry for Absolute Phasing

We report second harmonic generation (SHG) electric field triplet interferometry performed using three mutually coherent ultrafast pulses in a common path with controllable relative phases, namely, the light fields of a sample signal (SI), a reference oscillator (RO), and a local oscillator (LO). The ROLO phase determined from the interference of the light fields produced by two quartz wafers is subtracted from the phase determined from the SIROLO interferogram to yield the signal phase, ϕ SI . The new method also calibrates the measured SHG intensity from a given sample internally by sending the fundamental light field reflected from the sample into one of the quartz wafers in the ROLO element. The approach avoids having to exchange the sample against a reference material with a known χ(2) value or known phase and accounts on-the-fly for situations where the reflected fundamental light field intensity changes with experimental conditions. The new method is successfully benchmarked against z-cut α-quartz, fused silica held at its point of zero charge, and hematite nanolayers in air, across three different interferometers. Furthermore, the approach should be applicable for other second-order nonlinear spectroscopies, such as vibrational or electronic sum-frequency generation.

Interfaces↗

Nonlinear quantum interferometric spectroscopy with entangled photon pairs

Here, we develop closed expressions for a time-resolved photon counting signal induced by an entangled photon pair in an interferometric spectroscopy setup. Superoperator expressions in Liouville-space are derived that can account for relaxation and dephasing induced by coupling to a bath. Interferometric setups mix matter and light variables non-trivially, which complicates their interpretation. We provide an intuitive modular framework for this setup that simplifies its description. Based on the separation between the detection stage and the light–matter interaction processes, we show that the pair entanglement time and the interferometric time-variables control the observed physics time scale. Only a few processes contribute in the limiting case of small entanglement time with respect to the sample response, and specific contributions can be singled out.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Proton acceleration in an overdense hydrogen plasma by intense CO 2 laser pulses with nonlinear propagation effects in the underdense pre-plasma

We report on proton acceleration from intense CO 2 laser-irradiated hydrogen plasmas at near-critical densities, with the density gradient steepened by Nd:YAG laser ablation-driven hydrodynamic shocks. While the experimental results, such as the quasi-monoenergetic proton spectra and their scaling with respect to the laser energy, are generally in agreement with the simulations, certain laser shots produced significantly higher proton energies than anticipated during the experiment. The increased proton energy may be linked to nonlinear propagation effects in the steepened plasma density ramp before the critical surface, including relativistic self-focusing and, for the case of temporally-structured laser pulses observed in the experiment, focusing of the trailing pulse through the plasma channel formed by the leading pulse 25 ps ahead. The occurrence of channel focusing in the underdense hydrogen plasma is supported by a subsequent pump-probe experiment with a dark-field imaging technique, where the formation of ion channels was observed after the passage of an intense CO 2 laser pulse

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calculation of the Equilibrium Evolution of the ZaP Flow $Z$ -Pinch Using a Four-Chord Interferometer

For this study, a four-chord interferometer and measurements from an array of surface-mounted magnetic probes were used in conjunction with equations of radial heat conduction and radial force balance to calculate the equilibrium evolution of a pinch plasma in the ZaP Flow Z-Pinch. A multiple shooting method was used to solve the nonlinear coupled differential equation system, with Ohmic heating and bremsstrahlung radiation as sources and sinks, respectively. Data from a single ZaP pulse are reported including profiles of magnetic field and temperature and their evolution. Profiles are dominated by high thermal conductivity near the axis which quickly decreases with radius. This is due to the plasma being weakly magnetized near the axis which increases thermal conductivity and flattens the temperature profile, but strongly magnetized near the characteristic radius, significantly reducing thermal conductivity and resulting in a large temperature gradient. The equilibrium evolution indicates that plasmas in ZaP heat and compress with increasing current as a result of magnetic compression during the quiescent period.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multidimensional resonance raman spectroscopy by six-wave mixing in the deep UV

Two-dimensional (2D) resonance Raman spectroscopies hold great potential for uncovering photoinduced relaxation processes in molecules but are not yet widely applied because of technical challenges. Here, we describe a newly developed 2D resonance Raman experiment operational at the third-harmonic of a Titanium-Sapphire laser. High-sensitivity and rapid data acquisition are achieved by combining spectral interferometry with a background-free (six-pulse) laser beam geometry. The third-harmonic laser pulses are generated in a filament produced by the fundamental and second-harmonic pulses in neon gas at pressures up to 35 atm. The capabilities of the setup are demonstrated by probing ground-state wavepacket motions in triiodide. The information provided by the experiment is explored with two different representations of the signal. In one representation, Fourier transforms are carried out with respect to the two experimentally controlled delay times to obtain a 2D Raman spectrum. Further insights are derived in a second representation by dispersing the signal pulse in a spectrometer. It is shown that, as in traditional pump-probe experiments, the six-wave mixing signal spectrum encodes the wavepacket's position by way of the (time-evolving) emission frequency. Anharmonicity additionally induces dynamics in the vibrational resonance frequency. In all cases, the experimental signals are compared to model calculations based on a cumulant expansion approach. This study suggests that multi-dimensional resonance Raman spectroscopies conducted on systems with Franck-Condon active modes are fairly immune to many of the technical issues that challenge off-resonant 2D Raman spectroscopies (e.g., third-order cascades) and photon-echo experiments in the deep UV (e.g., coherence spikes). The development of higher-order nonlinear spectroscopies operational in the deep UV is motivated by studies of biological systems and elementary organic photochemistries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Asymptotic optimality of twist-untwist protocols for Heisenberg scaling in atom-based sensing

Twist-untwist protocols for quantum metrology consist of a serial application of (1) unitary nonlinear dynamics (e.g., spin squeezing or Kerr nonlinearity), (2) parameterized dynamics U ( φ ) (e.g., a collective rotation or phase space displacement), and (3) time reversed application of step 1. Such protocols are known to produce states that allow Heisenberg scaling for experimentally accessible estimators of φ even when the nonlinearities are applied for times much shorter than required to produce Schrödinger cat states. In this work, we prove that, asymptotically in the number of particles, twist-untwist protocols provide the lowest estimation error among quantum metrology protocols that utilize two calls to a weakly nonlinear evolution and a readout involving only first and second moments of a total spin operator n → · J → . We consider the following physical settings: all-to-all interactions generated by one-axis twisting J z 2 (e.g., interacting Bose gases), constant finite range spin-spin interactions of distinguishable or bosonic atoms (e.g., trapped ions or Rydberg atoms, or lattice bosons). In these settings, we further show that the optimal twist-untwist protocols asymptotically achieve 85% and 92% of the respective quantum Cramér-Rao bounds. We show that the error of a twist-untwist protocol can be decreased by a factor of L without an increase in the noise of the spin measurement if the twist-untwist protocol can be noiselessly iterated as an L layer quantum alternating operator ansatz.

74 ATOMIC AND MOLECULAR PHYSICS↗

Multidimensional four-wave-mixing spectroscopy with squeezed light

A set of nonlinear spectroscopic measurements with quantum light is presented here. It involves a strong pump with frequency ω pu and a weak probe atω pr interacting with a solid state target to generate a conjugated beam ω c =2ω pu -ω pr via nondegenerate four-wave mixing. The $\chi^{(3)}$ susceptibility can be measured by the noise spectra of the intensity difference of the squeezed beams. We discuss three spectroscopic setups based on squeezed light: first, single four-wave mixing in a single crystal; second, cascading scheme involving two crystals; third, an $\textit{SU}$(1, 1) interferometer based on two separate four-wave mixing processes. We further investigate the microscopic noise and optical losses in all three setups. Simulations are presented for silicon-vacancy color centers in diamond.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The structure of 3-D collisional magnetized bow shocks in pulsed-power-driven plasma flows

Here we investigate three-dimensional (3-D) bow shocks in a highly collisional magnetized aluminium plasma, generated during the ablation phase of an exploding wire array on the MAGPIE facility (1.4 MA, 240 ns). Ablation of plasma from the wire array generates radially diverging, supersonic ($M_S$ $\sim 7$), super-Alfvénic ($M_A>1$) magnetized flows with frozen-in magnetic flux $(R_M\gg1)$. These flows collide with an inductive probe placed in the flow, which serves both as the obstacle that generates the magnetized bow shock, and as a diagnostic of the advected magnetic field. Laser interferometry along two orthogonal lines of sight is used to measure the line-integrated electron density. A detached bow shock forms ahead of the probe, with a larger opening angle in the plane parallel to the magnetic field than in the plane normal to it. Since the resistive diffusion length of the plasma is comparable to the probe size, the magnetic field decouples from the ion fluid at the shock front and generates a hydrodynamic shock, whose structure is determined by the sonic Mach number, rather than the magnetosonic Mach number of the flow. The 3-D simulations performed using the resistive magnetohydrodynamic (MHD) code Gorgon confirm this picture, but under-predict the anisotropy observed in the shape of the experimental bow shock, suggesting that non-MHD mechanisms may be important for modifying the shock structure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Acoustoelastic characterization of plates using zero group velocity Lamb modes

Acoustoelasticity, a characteristic of material anharmonicity, gives rise to a link between wave propagation velocity and the stress state in materials. Ultrasonic techniques to monitor this coupling, particularly with high sensitivity and in a noncontact manner, can have widespread application both in the quantification of applied and residual stress and in the characterization of nonlinear material behavior through measurement of higher order elastic constants. Here, we use a laser ultrasonic technique to excite and detect zero group velocity (ZGV) Lamb wave resonances in aluminum plates under uniaxial loading. A laser line source is used to excite these resonances at different orientations with respect to the applied load, and the signals are detected using an interferometer. The effects of stress and source orientation on ZGV resonance frequencies are validated using the theory of acoustoelastic Lamb wave propagation. In addition, a model-based inversion technique is used to extract Murnaghan's third-order elastic constants from measurements of the stress dependence of the first two ZGV modes generated parallel and perpendicular to the applied load. Laser generation and detection of ZGV resonances is shown to be an effective and powerful approach for the noncontact and nondestructive acoustoelastic characterization of elastic waveguides.

36 MATERIALS SCIENCE↗

Designing high-power, octave spanning entangled photon sources for quantum spectroscopy

Entangled photon spectroscopy is a nascent field that has important implications for measurement and imaging across chemical, biology, and materials fields. Entangled photon spectroscopy potentially offers improved spatial and temporal-frequency resolutions, increased cross sections for multiphoton and nonlinear measurements, and new abilities in inducing or measuring quantum correlations. A critical step in enabling entangled photon spectroscopies is the creation of high-flux entangled sources that can use conventional detectors as well as provide redundancy for the losses in realistic samples. Here, we report a periodically poled, chirped, lithium tantalate platform that generates entangled photon pairs with ~10 -7 efficiency. For a near watt level diode laser, this results in a near μW-level flux. The single photon per mode limit that is necessary to maintain non-classical photon behavior is still satisfied by distributing this power over up to an octave-spanning bandwidth. The spectral–temporal photon correlations are observed via a Michelson-type interferometer that measures the broadband Hong–Ou–Mandel two-photon interference. A coherence time of 245 fs for a 10 nm bandwidth in the collinear case and a coherence time of 62 fs for a 125 nm bandwidth in the non-collinear case are measured using a CW pump laser and, essentially, collecting the full photon cone. We outline in detail the numerical methods used for designing and tailoring the entangled photons source, such as changing center wavelength or bandwidth, with the ultimate aim of increasing the availability of high-flux UV–Vis entangled photon sources in the optical spectroscopy community.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Pseudorandom Binary Arrays for Calibration of Surface Profile Metrology Tools

Optical metrology tools, especially for short wavelengths (extreme ultraviolet and x-ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable scattering. A major difficulty in using surface profilometers arises due to the unknown point-spread function (PSF) of the instruments [G. D. Boreman, Modulation Transfer Function in Optical and Electro-Optical Systems (SPIE, Bellingham, WA, 2001)] that is responsible for distortion of the measured surface profile. Generally, the distortion due to the PSF is difficult to account for because the PSF is a complex function that comes to the measurement via the convolution operation, while the measured profile is described with a real function. Accounting for instrumental PSF becomes significantly simpler if the result of measurement of a profile is presented in the spatial frequency domain as a power spectral density (PSD) distribution [J. W. Goodman, Introduction to Fourier Optics, 3rd ed. (Roberts and Company, Englewood, CO, 2005)]. For example, measured PSD distributions provide a closed set of data necessary for three-dimensional calculations of scattering of light by the optical surfaces [E. L. Church et al., Opt. Eng. (Bellingham) 18, 125 (1979); J. C. Stover, Optical Scattering, 2nd ed. (SPIE Optical Engineering Press, Bellingham, WA, 1995)]. The distortion of the surface PSD distribution due to the PSF can be modeled with the modulation transfer function (MTF), which is defined over the spatial frequency bandwidth of the instrument. The measured PSD distribution can be presented as a product of the squared MTF and the ideal PSD distribution inherent for the system under test. Therefore, the instrumental MTF can be evaluated by comparing a measured PSD distribution of a known test surface with the corresponding ideal numerically simulated PSD. The square root of the ratio of the measured and simulated PSD distributions gives the MTF of the instrument. The applicability of the MTF concept to phase map measurements with optical interferometric microscopes needs to be experimentally verified as the optical tool and algorithms may introduce nonlinear artifacts into the process. In previous work [V. V. Yashchuk et al., Proc. SPIE 6704, 670408 (2007); Valeriy V. Yashchuk et al., Opt. Eng. (Bellingham) 47, 073602 (2008)] the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on binary pseudorandom (BPR) gratings. Here, the authors present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as global position systems and wireless communication protocols. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the uniformly redundant array (URA) prescription [E. E. Fenimore and T. M. Cannon, Appl. Opt. 17, 337 (1978)] initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat PSD. Three different size BPR array patterns were fabricated by electron beam lithography and induction coupled plasma etching of silicon. The basic size units were 200, 400, and 600 nm. Two different etch processes were used, CF{sub 4}/Ar and HBr, which resulted in undercut and vertical sidewall profiles, respectively. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope using all available objectives. The MicroMap{trademark}-570 interferometric microscope uses incoherent illumination from a tungsten filament source and common path modulated phase shifting interference to produce a set of interferograms detected on a change coupled device. Mathematical algorithms applied to the datasets yield the surface phase map. The HBr etched two-dimensional BPR arrays have proven to be a very effective calibration standard making possible direct calibration corrections without the need of additional calculation considerations, while departures from the ideal vertical sidewall require an additional correction term for the CF{sub 4}/Ar etched samples [Samuel K. Barber et al., Abstract to Optics and Photonics 2009: Optical Engineering and Applications Symposium, San Diego, CA, 2-6 August 2009]. Initial surface roughness of low cost 'prime' wafers limits low magnification calibration but should not be a limitation if better polished samples are used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗