Search NASA⌕ Search

SEARCH · Search NASA

Results for “nonlinear optical signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

84 records · Page 5

Customizable wave tailoring nonlinear materials enabled by bilevel inverse design

Abstract Passive wave transformation via nonlinearity is ubiquitous in settings from acoustics to optics and electromagnetics. It is well known that different nonlinearities yield different effects on propagating signals, which raises the question of “what precise nonlinearity is the best for a given wave tailoring application?” In this work, considering a one-dimensional spring-mass chain connected by polynomial springs (a variant of the Fermi-Pasta-Ulam-Tsingou system), we introduce a bilevel inverse design method which couples the shape optimization of structures for tailored constitutive responses with reduced-order nonlinear dynamical inverse design. We apply it to two qualitatively distinct problems—minimization of peak transmitted kinetic energy from impact, and pulse shape transformation—demonstrating our method’s breadth of applicability. For the impact problem, we obtain two fundamental insights. First, small differences in nonlinearity can drastically change the dynamic response of the system, from severely under- to outperforming a comparative linear system. Second, the oft-used strategy of impact mitigation via “energy locking” bistability can be significantly outperformed by our optimal nonlinearity. We validate this case with impact experiments and find excellent agreement. This study establishes a framework for broader passive nonlinear mechanical wave tailoring material design, with applications to computing, signal processing, shock mitigation, and autonomous materials.

Science & Technology - Other Topics↗

Ghost imaging second harmonic generation microscopy

Second harmonic generation (SHG) microscopy is useful for visualizing interfaces and sub-structures within a wide range of materials due to the propensity for SHG to occur in non-centrosymmetric environments. However, since SHG is a nonlinear process generally necessitating small focal sizes for higher peak powers, a raster scanning approach is usually needed to build an SHG image over a significant sample size. While raster scanning is effective, there is a cost in terms of the time needed to acquire the image and, also, some materials cannot withstand the higher optical intensities within the small focal volume. As such, we describe a SHG microscopy approach based on ghost imaging (GI), which enables imaging data to be collected in parallel rather than sequentially as in raster scanning techniques. We experimentally demonstrate the approach and combine GI-SHG with compressive sensing to make further substantial gains in reducing the amount of sampling required for image reconstruction. Furthermore, GI-SHG is shown to have significant advantages for imaging in highly scattering environments, partly because GI is a background-free approach requiring spatial correlations between photons that travel two paths, with one path entirely devoid of sample interaction. This basic property of GI means that only the photons that travel unimpeded through the sample preserve the spatial correlations needed to reconstruct the image, while more scattered photons do not contribute to the overall GI signal. Finally, we compare the image quality and sampling properties of three different reconstruction algorithms used for compressive sensing.

47 OTHER INSTRUMENTATION↗

Multidimensional four-wave-mixing spectroscopy with squeezed light

A set of nonlinear spectroscopic measurements with quantum light is presented here. It involves a strong pump with frequency ω pu and a weak probe atω pr interacting with a solid state target to generate a conjugated beam ω c =2ω pu -ω pr via nondegenerate four-wave mixing. The $\chi^{(3)}$ susceptibility can be measured by the noise spectra of the intensity difference of the squeezed beams. We discuss three spectroscopic setups based on squeezed light: first, single four-wave mixing in a single crystal; second, cascading scheme involving two crystals; third, an $\textit{SU}$(1, 1) interferometer based on two separate four-wave mixing processes. We further investigate the microscopic noise and optical losses in all three setups. Simulations are presented for silicon-vacancy color centers in diamond.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electrically interfaced Brillouin-active waveguide for microwave photonic measurements

New strategies for converting signals between optical and microwave domains could play a pivotal role in advancing both classical and quantum technologies. Traditional approaches to optical-to-microwave transduction typically perturb or destroy the information encoded on intensity of the light field, eliminating the possibility for further processing or distribution of these signals. In this paper, we introduce an optical-to-microwave conversion method that allows for both detection and spectral analysis of microwave photonic signals without degradation of their information content. This functionality is demonstrated using an optomechanical waveguide integrated with a piezoelectric transducer. Efficient electromechanical and optomechanical coupling within this system permits bidirectional optical-to-microwave conversion with a quantum efficiency of up to -54.16 dB. Leveraging the preservation of the optical field envelope in intramodal Brillouin scattering, we demonstrate a multi-channel microwave photonic filter by transmitting an optical signal through a series of electro-optomechanical waveguide segments, each with distinct resonance frequencies. Such electro-optomechanical systems could offer flexible strategies for remote sensing, channelization, and spectrum analysis in microwave photonics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Retrieval of the molecular orientation distribution from atom-pair angular distributions

Imaging laser-induced rotational dynamics is an important and active field due to its applications in capturing reactions in the molecular frame and in molecular imaging. Experimental measurement of the molecular orientation distribution, as a function of the Euler angles, has only been demonstrated for special cases when the detectable signal is generated along the molecular symmetry axis. Here we developed the general theory that maps the probability density distribution of the molecular orientation to the atom-pair angular distributions for nonlinear molecules. With the theory, the molecular orientation distribution can be retrieved from the measured atom-pair angular distribution, which we demonstrate experimentally using ultrafast electron diffractive imaging of impulsively aligned trifluoro-iodomethane molecules. Here, the retrieved molecular orientation distribution is in good agreement with direct numerical simulations of the time-dependent Schrodinger equation using the experimental conditions. Unlike the existing retrieval methods, the retrieval method does not require solving Schrodinger equation, works for any alignment method, and is in principle applicable to asymmetric top molecules.

74 ATOMIC AND MOLECULAR PHYSICS↗

State-selective probing of CO 2 autoionizing inner valence Rydberg states with attosecond extreme ultraviolet four-wave-mixing spectroscopy

Nonlinear spectroscopies can disentangle spectra that are congested due to inhomogeneous broadening. Here, in conjunction with theoretical calculations, attosecond extreme ultraviolet (XUV) four-wave-mixing (FWM) spectroscopy is utilized to probe the dynamics of autoionizing inner valence excited Rydberg states of the polyatomic molecule, CO 2 . This tabletop nonlinear technique employs a short attosecond XUV pulse train and two noncollinear, few-cycle near-infrared pulses to generate background-free XUV wave-mixing signals. FWM emission is observed from the n=5-7 states of the Henning sharp ndσ g Rydberg series that converges to the ionic $\widetilde{B}$ 2 Σ$^{+}_{u}$ state. However, these transient emission signals decay with lifetimes of 33 ± 6, 53 ± 2, and 94 ± 2 fs, respectively, which calculations show are consistent with the lifetimes of the short-lived n=6-8 members of the nsσ g character Henning diffuse Rydberg series. The oscillator strengths of transitions between states involved in all possible resonant FWM processes are calculated, verifying that the nonlinear spectra are dominated by pathways described by an initial excitation to the diffuse nsσ g Rydberg series and emission from the sharp ndσ g Rydberg series. The results substantiate not only that attosecond XUV FWM spectroscopy produces rigorous and meaningful measurements of ultrafast dynamics in polyatomic systems, but also that nonlinear spectroscopic techniques are versatile tools to selectively probe dynamics that are otherwise difficult to access.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elucidating the Interfacial Barriers in Lanthanide Back-Extraction: From Water to Oil and Back Again

Recovery of critical rare earth elements from complex mixtures has long been realized via solvent extraction, where ions in an aqueous phase are separated into an organic phase using amphiphilic ligands. While a great deal of effort has been placed on understanding this forward reaction, substantial knowledge gaps in the back-extraction process remain. This includes the mechanism of interfacial dissociation and transport back into a highly acidic aqueous phase for further processing. In this work, we connect back-extraction kinetics made in realistic solvent extraction systems to salient interfacial chemistry and structure that represent bottlenecks in the back-extraction of lanthanide ions. We show that the interface between the two liquid phases varies dramatically based on the composition of both phases. Water stretching signals are shown to report on the population of lingering interfacial complexes and are thus used as a reporter of competitive adsorption from excess free ligands in solution for limited interfacial vacancies. We show that excess free ligands, often used to improve forward extractions, set up interfacial blockades inhibiting back-extraction both kinetically and thermodynamically. In conclusion, this insight opens up avenues to tune interfacial properties to facilitate a more dynamic, exchangeable interface to speed up back-extractions while using less energy intensive chemical swings.

Interfaces↗

Experimental demonstration of externally driven millimeter-wave particle accelerator structure

We report the experimental demonstration of a mm-wave electron accelerating structure powered by a high-power rf source. We demonstrate reliable coupling of an unprecedented rf power—up to 575kW into the mm-wave accelerator structure using a quasi-optical setup. This standing wave accelerating structure consists of a single-cell copper cavity and a Gaussian to TM 01 mode converter. The accelerator structure is powered by 110 GHz, 10-ns long rf pulses. These pulses are chopped from 3 microsecond pulses from a gyrotron oscillator using a laser-driven silicon switch. We show an unprecedented high gradient up to 230MV/m that corresponds to a peak surface electric field of more than 520 MV/m. We have achieved these results after conditioning the cavity with more than 100,000 pulses. We also report preliminary measurements of rf breakdown rates, which are important for understanding rf breakdown physics in the millimeter-wave regime. Furthermore, these results open up many frontiers for applications not only limited to the next generation particle accelerators but also x-ray generation, probing material dynamics, and nonlinear light-matter interactions at mm-wave frequency.

43 PARTICLE ACCELERATORS↗

Adaptive noise canceling for transient absorption microscopy

Significance: Ultrafast fiber lasers are an attractive alternative to bulk lasers for nonlinear optical microscopy for their compactness and low cost. The high relative intensity noise (RIN) of these lasers poses a challenge for pump-probe measurements such as transient absorption and stimulated Raman scattering, along with modalities that provide label-free contrast from the vibrational and electronic structure of molecules. Aim: Digital adaptive filtering was applied to determine the applicability for canceling laser RIN in a transient absorption microscope with an ultrafast fiber laser source. Approach: Digitized signals from the transmitted probe and reference photodetectors were fed to an adaptive filter in MATLAB, running in a noise canceling configuration. This result was then fed to a software lock-in algorithm to demodulate the pump-probe signal. Images were built up one line scan at a time with a 3.5-kHz resonant scanner, with 100× averaging. The imaging target was Bi4Ge3O12, which exhibits nondegenerate two-photon absorption at the pump/probe wavelengths used (530-nm pump and 490-nm probe). Results: Without adaptive noise cancellation, the lock-in output primarily passes the laser RIN within its detection bandwidth, resulting in images that closely follow the linear transmissivity and lack sensitivity to pump-probe time delay. With adaptive noise cancellation in front of the lock-in, the RIN rejection is enough to restore the z-sectioning and sensitivity to pump-probe delay, as expected for transient absorption. Results were limited primarily by noise from the photodetector and analog-to-digital converter. Conclusions: Digital adaptive noise cancellation, even when limited by electronics noise, can recover pump-probe signals by removal of laser RIN, under conditions where averaging alone fails.

42 ENGINEERING↗

Soft x-ray high-harmonic generation in an anti-resonant hollow core fiber driven by a 3 μ m ultrafast laser

High-harmonic upconversion driven by a mid-infrared femtosecond laser can generate coherent soft x-ray beams in a tabletop-scale setup. Here, we report on a compact ytterbium-pumped optical parametric chirped pulse amplifier (OPCPA) laser system seeded by an all-fiber front-end and employing periodically poled lithium niobate (PPLN) nonlinear media operated near the pulse fluence limits of current commercially available PPLN crystals. The OPCPA delivers 3 µm wavelength pulses with 775 µJ energy at 1 kHz repetition rate, with transform-limited 120 fs pulse duration, diffraction-limited beam quality, and ultrahigh 0.33% rms energy stability over >18 h. Using this laser, we generate soft x-ray high harmonics (HHG) in argon gas by focusing into a low-loss, high-pressure gas-filled anti-resonant hollow core fiber (ARHCF), generating coherent light at photon energies up to the argon L-edge (250 eV) and carbon K-edge (284 eV), with high beam quality and ∼1% rms energy stability. This work demonstrates soft x-ray HHG in a high-efficiency guided-wave phase matched geometry, overcoming the high losses inherent to mid-IR propagation in unstructured waveguides, or the short interaction lengths of gas cells or jets. The ARHCF can operate in the long term without damage and with the repetition rate, stability, and robustness required for demanding applications in spectromicroscopy and imaging. Finally, we discuss routes for further optimizing the soft x-ray HHG flux by driving He at higher laser intensities using either the signal (1.5 μm) or idler wavelengths (3 μm).

Femtosecond lasers↗

Efficient ptychographic phase retrieval via a matrix-free Levenberg-Marquardt algorithm

The phase retrieval problem, where one aims to recover a complex-valued image from far-field intensity measurements, is a classic problem encountered in a range of imaging applications. Modern phase retrieval approaches usually rely on gradient descent methods in a nonlinear minimization framework. Calculating closed-form gradients for use in these methods is tedious work, and formulating second order derivatives is even more laborious. Additionally, second order techniques often require the storage and inversion of large matrices of partial derivatives, with memory requirements that can be prohibitive for data-rich imaging modalities. We use a reverse-mode automatic differentiation (AD) framework to implement an efficient matrix-free version of the Levenberg-Marquardt (LM) algorithm, a longstanding method that finds popular use in nonlinear least-square minimization problems but which has seen little use in phase retrieval. Furthermore, we extend the basic LM algorithm so that it can be applied for more general constrained optimization problems (including phase retrieval problems) beyond just the least-square applications. Since we use AD, we only need to specify the physics-based forward model for a specific imaging application; the first and second-order derivative terms are calculated automatically through matrix-vector products, without explicitly forming the large Jacobian or Gauss-Newton matrices typically required for the LM method. We demonstrate that this algorithm can be used to solve both the unconstrained ptychographic object retrieval problem and the constrained “blind” ptychographic object and probe retrieval problems, under the popular Gaussian noise model as well as the Poisson noise model. We compare this algorithm to state-of-the-art first order ptychographic reconstruction methods to demonstrate empirically that this method outperforms best-in-class first-order methods: it provides excellent convergence guarantees with (in many cases) a superlinear rate of convergence, all with a computational cost comparable to, or lower than, the tested first-order algorithms.

36 MATERIALS SCIENCE↗

Two-Photon Fluorescence Microscope for Microgravity Research

A two-photon fluorescence microscope has been developed for the study of biophysical phenomena. Two-photon microscopy is a novel form of laser-based scanning microscopy that enables three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon optical microscopy, two-photon microscopy utilizes the simultaneous nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption, so an ultra-fast pulsed laser source is typically employed. On the other hand, the critical energy threshold for two-photon absorption leads to fluorophore excitation that is intrinsically localized to the focal volume. Consequently, two-photon microscopy enables optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction (relative to one-photon optical microscopy) in photon-induced damage because of the longer excitation wavelength. This reduction is especially advantageous for in vivo studies. Relative to confocal microscopy, there is also a reduction in background fluorescence, and, because of a reduction in Rayleigh scattering, there is a 4 increase of penetration depth. The prohibitive cost of a commercial two-photon fluorescence-microscope system, as well as a need for modularity, has led to the construction of a custom-built system (see Figure 1). This system includes a coherent mode-locked titanium: sapphire laser emitting 120-fs-duration pulses at a repetition rate of 80 MHz. The pulsed laser has an average output power of 800 mW and a wavelength tuning range of 700 to 980 nm, enabling the excitation of a variety of targeted fluorophores. The output from the laser is attenuated, spatially filtered, and then directed into a confocal scanning head that has been modified to provide for side entry of the laser beam. The laser output coupler has been replaced with a dichroic filter that reflects the longer-wavelength excitation light and passes the shorter-wavelength fluorescence light. Also, the confocal pinhole has been removed to increase the signal strength. The laser beam is scanned by a twoperpendicular- axis pair of galvanometer mirrors through a pupil transfer lens into the side port of an inverted microscope. Finally, the beam is focused by a 63-magnification, 1.3-numerical- aperture oil-immersion objective lens onto a specimen. The pupil transfer lens serves to match the intermediate image planes of the scanning head and the microscope, and its location is critical. In order to maximize the quality of the image, (that is, the point spread function of the objective lens for all scan positions), the entire system was modeled in optical-design software, and the various free design parameters (the parameters of the spatial-filter components as well as the separations of all of the system components) were determined through an iterative optimization process. A modular design was chosen to facilitate access to the optical train for future fluorescence correlation spectroscopy and fluorescence-lifetime experiments.

Fischer, David G.↗