Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear radiation detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Gamma single-hit detector for NDSE

2021 annual project report for SDRD Program. Edited and approved by author. Will be made available on SDRD website in future. An associated abstract/summary for this longer report will be submitted to STIP as well.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determining g A / g V with High-Resolution Spectral Measurements Using a LiInSe 2 Bolometer

Neutrinoless double beta decay (0νββ) processes sample a wide range of intermediate forbidden nuclear transitions, which may be impacted by quenching of the axial vector coupling constant (g A /g V ), the uncertainty of which plays a pivotal role in determining the sensitivity reach of 0νββ experiments. Here we present measurements performed on a high-resolution LiInSe 2 bolometer in a “source = detector” configuration to measure the spectral shape of the fourfold forbidden β decay of 115 In . The value of g A /g V is determined by comparing the spectral shape of theoretical predictions to the experimental β spectrum taking into account various simulated background components as well as a variety of detector effects. We find evidence of quenching of g A /g V at >5 σ with a model-dependent quenching factor of 0.655 ± 0.002 as compared to the free-nucleon value for the interacting shell model. We also measured the 115 In half-life to be [5.18 ± 0.06(stat) $^{+0.005}_{- 0.015}$(sys)] x 10 14 yr within the interacting shell model framework. This Letter demonstrates the power of the bolometeric technique to perform precision nuclear physics single-β decay measurements, which along with improved nuclear modeling can help reduce the uncertainties in the calculation of several decay nuclear matrix elements including those used in 0νββ sensitivity calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pulse-shape analysis in Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 room-temperature radiation detectors

The effect of trapping of charge carriers on the shape of the charge pulses from room temperature nuclear detectors, based on a recently discovered quaternary semiconductor Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 (CZTS), has been studied. Here, we present a charge-trapping model that explains the pulse shapes for its entire duration from radiation detectors containing multiple defect types. A piecewise continuous model, based on the movement of a large number of charge carriers rather than a single charge, has been proposed to explain the pulse shapes from planar room temperature nuclear detectors. An experimental method based on the model has been described to extract charge-trapping information. This model can be applied to similar semiconductor detectors with electrically active trap centers, in general, to extract information like pre-trapping drift times. Charge pulses from a CZTS planar detector, exposed to 5486 keV alpha particles emitted by a 241Am source, were acquired using a digitizer, and the pulse shapes were explained based on the proposed model. The pre-trapping drift times for electrons as well as holes in CZTS were calculated and studied as a function of operating bias voltage, and a contrast between their bias dependent behaviors was noticed, indicating the behavioral difference of electron and hole traps.

42 ENGINEERING↗

The 3 He BF 3 Giant Barrel (HeBGB) neutron detector

(α,n) reactions play an important role in nuclear astrophysics and applications and are an important background source in neutrino and dark matter detectors. Measurements of total (α,n) cross sections employing direct neutron detection often have a considerable systematic uncertainty associated with the energy-dependent neutron detection efficiency and the unknown initial neutron energy distribution. Furthermore, the 3 He BF 3 Giant Barrel (HeBGB) neutron detector was built at the Edwards Accelerator Laboratory at Ohio University to overcome this challenge. HeBGB offers a near-constant neutron detection efficiency of (7.5 ± 1.2)% over the neutron energy range 0.01 MeV–9.00 MeV, removing a significant source of systematic uncertainty present in earlier (α,n) cross section measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermodynamic stability of xenon-doped liquid argon detectors

Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or that utilize high xenon concentrations. In this work, we analyze the causes of these instabilities and describe a small (liter-scale) apparatus with a unique cryogenic circuit specifically designed to handle argon-xenon mixtures. The system is capable of condensing argon gas mixed with $\mathscr{O}$ (1%) xenon by volume and maintains a stable liquid mixture near the xenon saturation limit while actively circulating it in the gas phase. We also demonstrate control over instabilities that develop when the detector condition is allowed to deviate from optimized settings. This progress enables future liquid argon detectors to benefit from the effects of high concentrations of xenon doping, such as more efficient detection of low-energy ionization signals. In conclusion, this work also develops tools to study and mitigate instabilities in large argon detectors that use low concentration xenon doping.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A demonstrator for a real-time AI-FPGA-based triggering system for sPHENIX at RHIC

The RHIC interaction rate at sPHENIX will reach around 3 MHz in pp collisions and requires the detector readout to reject events by a factor of over 200 to fit the DAQ bandwidth of 15 kHz. Some critical measurements, such as heavy flavor production in pp collisions, often require the analysis of particles produced at low momentum. This prohibits adopting the traditional approach, where data rates are reduced through triggering on rare high momentum probes. We explore a new approach based on real-time AI technology, adopt an FPGA-based implementation using a custom designed FELIX-712 board with the Xilinx Kintex Ultrascale FPGA, and deploy the system in the detector readout electronics loop for real-time trigger decision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Interdiction Through Relocatable Detectors

The NNSA Office of Nuclear Smuggling Detection and Deterrence (NSDD) has investigated a set of minimal-infrastructure radiation detection systems as alternatives to fixed Radiation Portal Monitors (RPMs) for nuclear interdiction applications. These versatile and relocatable systems can improve nuclear security in missions or locations that do not warrant or support a standard fixed radiation detection system. Over 2019, a variety of relocatable detectors were characterized at the Interdiction Technologies Integration Laboratory at Pacific Northwest National Laboratory (PNNL). Evaluated detectors were diverse in their size and capabilities, ranging from backpack-sized systems to lane-spanning cargo scanning portals. Both spectroscopic and non-spectroscopic pedestrian and vehicle detection systems were characterized against uranium and plutonium sources. Signatures from the sources were modulated by both shielding and distance to quantify the performance of the relocatable systems as signal strength was decreased. Findings showed that relocatable spectroscopic detectors with isotope identification capabilities could reduce nuisance alarm rates compared to conventional fixed installation, gross-counting, radiation portal monitors. In vehicle scanning applications, detection ability generally trended with detection volume, regardless of spectral capability. In pedestrian scanning applications, several smaller backpack-sized detector systems were found to be more sensitive to detecting material than pedestrian portal monitors. The results of this characterization effort have helped inform the deployment of versatile equipment to improve nuclear security missions.

relocatable detectors, Nuclear Security↗

Precision pulse shape simulation for proton detection at the Nab experiment

The Nab experiment at Oak Ridge National Laboratory, USA, aims to measure the beta-antineutrino angular correlation following neutron β decay to an anticipated precision of approximately 0.1%. The proton momentum is reconstructed through proton time-of-flight measurements, and potential systematic biases in the timing reconstruction due to detector effects must be controlled at the nanosecond level. In conclusion, we present a thorough and detailed semiconductor and quasiparticle transport simulation effort to provide precise pulse shapes, and report on relevant systematic effects and potential measurement schemes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of uranium-photofission neutrons with a 4 He scintillation detector

The use of photon active interrogation to detect special nuclear material has held significant theoretical promise, as the interrogating source particles, photons, are fundamentally different from one of the main signatures of special nuclear material: neutrons produced in nuclear fission. However, neutrons produced by photonuclear reactions in the accelerator target, collimator, and environment can obscure the fission neutron signal. These (γ, n) neutrons could be discriminated from fission neutrons by their energy spectrum, but common detectors sensitive to the neutron spectrum, like organic scintillators, are typically hampered by the intense photon background characteristic of photon-based active interrogation. In contrast, high-pressure 4 ⁢He-based scintillation detectors are well-suited to photon active interrogation, as they are similarly sensitive to fast neutrons and can measure their spectrum, but show little response to gamma rays. Here, in this work, a photon active interrogation system utilizing a 4 ⁢He scintillation detector and a 9 MeV linac-bremsstrahlung x-ray source was experimentally evaluated. The detector was shown to be capable of operating in intense gamma-ray environments and detecting photofission neutrons from 238 ⁢U when interrogated by this x-ray source. The photofission neutrons show clear spectral separation from (γ, n) neutrons produced in lead, a common shielding material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The BUTTON-30 detector at Boulby

The BUTTON-30 detector is a 30-tonne technology demonstrator designed to evaluate the potential of hybrid event detection, simultaneously exploiting both Cherenkov and scintillation light to detect particles produced in neutrino interactions. The detector is installed at a depth of 1.1 km in the Boulby Underground Laboratory allowing to test the performance of this new technology underground in a low background environment. This paper describes the design and construction of the experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ECCE unpolarized TMD measurements

For this work, we performed feasibility studies for various measurements that are related to unpolarized TMD distribution and fragmentation functions for the ECCE detector proposal. The processes studied include semi-inclusive Deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The single hadron cross sections and multiplicities were extracted as a function of the DIS variables x and Q 2 , as well as the semi-inclusive variables z, which corresponds to the momentum fraction the detected hadron carries relative to the struck parton and P T , which corresponds to the transverse momentum of the detected hadron relative to the virtual photon. The expected statistical precision of such measurements is extrapolated to accumulated luminosities of 10 fb –1 and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields. The expected uncertainties are then used to obtain the expected impact on the related TMD distribution and fragmentation functions. We find that the ECCE detector proposal fulfills the physics requirements on these channels as detailed in the EIC Yellow Report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CMS Phase-1 Pixel Detector Upgrade

The CMS detector at the CERN LHC features a silicon pixel detector as its innermost subdetector. The original CMS pixel detector has been replaced with an upgraded pixel system (CMS Phase-1 pixel detector) in the extended year-end technical stop of the LHC in 2016/2017. The upgraded CMS pixel detector is designed to cope with the higher instantaneous luminosities that have been achieved by the LHC after the upgrades to the accelerator during the first long shutdown in 2013–2014. Compared to the original pixel detector, the upgraded detector has a better tracking performance and lower mass with four barrel layers and three endcap disks on each side to provide hit coverage up to an absolute value of pseudorapidity of 2.5. This paper describes the design and construction of the CMS Phase-1 pixel detector as well as its performance from commissioning to early operation in collision data-taking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design optimization of MAPS-based detectors using a data-driven fast simulation approach

A parametric simulation tool for pixel sensors is presented. A realistic pixel response is simulated purely based on measurement input, without requiring detailed knowledge of the underlying manufacturing process. As such, it provides an efficient alternative to the use of Technology Computer-Aided Design simulations, which typically depend on proprietary process information. Due to its parametric approach, the package is fast and thus particularly useful for larger detector systems and high hit rate environments. This work presents measurements, simulation and its validation for the MALTA2 sensor. It is a small collection electrode monolithic active pixel sensor produced in the Tower 180 nm complementary metal-oxide-semiconductor imaging process. Modifications to the sensor’s periphery, mainly in the hit merger, are studied in order to optimize the performance for tracking and calorimetry. This optimization is of special interest as part of the MALTA3 sensor redesign in the 65 nm Tower Partners Semiconductor Co. process.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization and pulse-shape discrimination of a multi-stacked structure of ZnS: Ag/PMMA for fast-neutron detection in high-flux environments

The Micro-Layered Fast Neutron Detector (MLFD) is a proton-recoil scintillator that incorporates the basic concept of a Hornyak button detector with an improved design using a layered structure of ZnS:Ag and PMMA (polymethyl methacrylate). The MLFD was predicted to have low sensitivity to gamma rays, hence pulse shape discrimination was performed to determine the gamma-ray contribution. Presented in this paper are the pulse-shape discrimination characteristics of the MLFD. Additionally, the charge integration technique was employed to discriminate between the neutrons and gamma rays using a fast digitzer. The MLFD was found to exhibit excellent neutron/gamma-ray discrimination, with the highest Figure-of-Merit (FoM) being 4.56. With PSD, the neutron signal is distinct from gamma-ray, Ĉerenkov and electronic noise signals. This clear separation was achieved due to the large differences in decay times of the neutron and gamma-ray-induced pulses in the ZnS:Ag phosphor. The MLFD can be employed in high gamma-ray exposure fields, up to at least 1287.7 mR/hr, without appreciable degradation in PSD performance.

47 OTHER INSTRUMENTATION↗

Dependence of polytetrafluoroethylene reflectance on thickness at visible and ultraviolet wavelengths in air

Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. However, the reflectance of PTFE is a function of its thickness. Here, in this work, we investigate this dependence in air for light of wavelengths 260 nm and 450 nm using two complementary methods. We find that PTFE reflectance for thicknesses from 5 mm to 10 mm ranges from 92.5% to 94.5% at 450 nm, and from 90.0% to 92.0% at 260 nm. We also see that the reflectance of PTFE of a given thickness can vary by as much as 2.7% within the same piece of material. Finally, we show that placing a specular reflector behind the PTFE can recover the loss of reflectance in the visible without introducing a specular component in the reflectance.

47 OTHER INSTRUMENTATION↗

High-resolution 3D-printed plastic scintillators with tertiary dye

Additive manufacturing offers efficient production of plastic scintillators with nontrivial geometries using vat polymerization, allowing fabrication of geometries which would be difficult or even impossible to produce using conventional subtractive manufacturing. This work presents a novel photocurable scintillator formula that includes coumarin 450 as a tertiary dye to enable high-resolution 3D printing via the manipulation of the 405 nm cure light. Bulk photocured and 3D printed (with and without tertiary dye) samples were compared through observational assessment and spectral response. All samples showed pulse shape discrimination between neutron and gamma events. Inclusion of the tertiary dye has minimal impact on emission spectrum and light output, but significant impact on print resolution as shown by comparison of printed high-complexity geometries and feature resolution test objects. With the use of a cure-limiting dye, unsupported features — such as freestanding pillars — were resolvable down to 0.7 mm. Even finer resolution at or below 0.1 mm was achieved in fully supported, integrated structures printed with off-the-shelf 405 nm desktop 3D printer. Scintillators demonstrated a light output up to 50% of EJ-200 with a PSD figure of merit up to 1.35 at 0.9–1.1 MeVee.

36 MATERIALS SCIENCE↗