Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear science and engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The Mu2e Crystal and SiPM Calorimeter: Construction Status

The Mu2e experiment at Fermilab searches for the neutrino-less conversion of a negative muon into an electron, with a distinctive signature of a mono-energetic electron with an energy of 104.967 MeV. The calorimeter is made of two disks of pure CsI crystals, each read out by two custom large-area UV-extended silicon photomultipliers (SiPMs). It plays a fundamental role in providing excellent particle identification capabilities and an online trigger filter while improving the track reconstruction, requiring better than 10% energy and 500 ps timing resolutions for 100 MeV electrons. In this article, we present the status of construction and the quality control (QC) performed on the produced crystals and photosensors, the development of the rad-hard electronics, and the most important results of the irradiation tests. Construction of the mechanics is also reported. Status and plans for the calorimeter assembly and its first commissioning are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Design for Thermal/Epithermal eXperiments (TEX) with Absorbers to Provide Validation Benchmarks for Y-12 Electrorefining Facility

One of the main goals of the Thermal/Epithermal eXperiments (TEX) project is to use existing Nuclear Criticality Safety Program (NCSP) assets to create critical experiment plutonium and uranium test beds for materials important to criticality safety that have insufficient benchmark evaluations. The plutonium test bed experiments were completed in 2018 and are published in the 2020 edition of the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The uranium test bed assemblies were measured in 2020, with benchmark preparation underway.

42 ENGINEERING↗

Isotope Production at the Jefferson Lab LERF Facility

The project initially proceeded well, meeting all of the Milestones. However, the need to create a new irradiation area in the LERF (the initial proposal was to use the CEBAF Injector) used up a larger fraction of the budget than foreseen. A further problem arose when the hot-cell became unavailable at VCU, followed by VCU dropping out of the collaboration. This meant that we were unable to separate the 67 Cu from the gallium. We replaced this by carrying out detailed gamma spectroscopy to determine the quantity of 67 Cu produced. This work was published as presentations in November of 2021 by the two doctoral students (Geno Santistevan and Robert Bentley) and proceedings articles for American Nuclear Society’s topical meeting AccApp21 (https://www.ans.org/pubs/proceedings/issue-3206/), as well as in invited, expanded versions in the peer-reviewed journal “Nuclear Science and Engineering”. Geno and Robert have subsequently successfully leveraged this research to achieve “doctoral candidacy” status and are expected to defend their dissertations in the Fall of 2023.

07 ISOTOPE AND RADIATION SOURCES↗

Klaus Mayer's Legacy and Leadership of Nuclear Forensics and the International Technical Working Group

The Nuclear Forensics International Technical Working Group (ITWG), in an evidentiary sense, has Dr. Klaus Mayer’s fingerprints all over it. His contributions to the working group and the broader international nuclear forensics community have been profound. As Klaus retires from the European Commission’s Joint Research Centre in Karlsruhe, Germany (JRC-Karlsruhe), it is only fitting to reflect on his dedication and lasting impact on nuclear forensics—guiding its evolution from its early days to its establishment as a vital tool for competent authorities in preventing and responding to the serious threat of nuclear and other radioactive materials out of regulatory control.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Field Test Report Neutron Scintillator Array Dry Storage Cask Scanner FY2024

During two weeks of Field Testing at the Idaho National Laboratory INTEC Cask Farm in July and August 2024, the LLNL Dry Storage Cask Scanner Array was lifted on top of an MC-10 dry storage fuel cask and operated to acquire neutron and gamma-ray data from the 24 fuel bundle positions. Neutron and gamma-ray data acquisition scans across the top of the cask of varying dwell times were performed July 15-18, 2024 and August 19-22, 2024 to evaluate the ability of the scanner data to reveal asymmetries in the fuel positions that reflect asymmetries in the MC-10 cask fuel bundle loading. The MC-10 cask 24 position fuel bundle loading at the INTEC Cask Farm is well documented, including the locations of six empty fuel bundle positions. This loading presents an opportunity to test the ability of the scanner system to detect diversion of spent fuel bundles as well as to validate the MC-10 cask MCNP modeling. The cask scanner array consists of six Stilbene crystal scintillator detectors and a linear actuator frame that moves the six detectors across the MC-10 dry storage cask to obtain data above each of the 24 fuel bundle positions. The detectors are connected to a pulse-shape discrimination data acquisition system capable of generating separate neutron and gamma-ray spectra for each detector and for each scan position. From the prior single detector Field Test in 2021 and iteration with MCNP modeling, the neutron and gamma-ray data were analyzed in multiple energy regions to identify an analysis method that would provide the strongest and most consistent signature of the asymmetric MC-10 cask fuel loading1 . From both the 2021 Field Test and the current Field Test results, the neutron capture gamma-ray count rate around 2.2 MeV provides the strongest signature of the asymmetric MC-10 cask fuel loading and has qualitative agreement with MCNP calculations. Counting all gamma-rays produces a similar signature. Neutrons emerging from the cask top are moderated and captured by the hydrogen in the polyethylene moderator and scintillator detector, producing a 2.2 MeV gamma ray which is seen in the scintillator gamma-ray spectrum. The count rate in the 2.2 MeV gamma-ray region is ~50 c/s, which is ~1000x higher than the ~0.05 n/s rate in the > 4MeV neutron region, and ~50x greater than the ~1 n/s rate in the neutrons > 500 keV region. Analysis of the 2.2 MeV neutron-capture Compton-scattered gamma-rays produces a statistically significant signature of the INTEC Cask Farm MC-10 asymmetric fuel loading. MCNP simulations indicate that the average neutron energy spectrum offers the potential to detect a large asymmetry from several missing bundles as well as individual missing fuel bundles. Testing this feature will require measurements on a cask with single missing elements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

S&TR April/May 2024 EMDEC Issue

At Lawrence Livermore National Laboratory, we focus on science and technology research to ensure our nation's security. We also apply that expertise to solve other important national problems in energy, bioscience, and the environment. Science & Technology Review is published eight times a year to communicate, to a broad audience, the Laboratory's scientific and technological accomplishments in fulfilling its primary missions. The publication's goal is to help readers understand these accomplishments and appreciate their value to the individual citizen, the nation, and the world.

99 GENERAL AND MISCELLANEOUS↗

FY25 Mid-Year Report: FNCL Enhancements Implementation

During the first half of FY25 the FNCL team has made consistent progress toward the completion of our project goals. The FNCL prototype panel design has been successfully applied to a fully instrumented 3-panel system which is actively under construction. The FNCL Demonstrator System contains solid scintillators instrumented with SiPMs, which operate on an updated CAEN digitizer, requires no high-voltage, and has a smaller overall footprint. The onboard software will include the LLNL-developed GMM-PSD signal processing. Later this year the system will be experimentally tested alongside the baseline FNCL instrument at LLNLs ISSA facility. In addition to a full systems test, the performance of a DD generator for active interrogation measurements compared to the standard AmLi source will be established for both systems. The data collected at the ISSA facility will be used to experimentally validate the FNCL-Fast Isotopic Fuel Assay’s (FIFA) capability to measure U-235 loading and to predict gadolinium poison content with passive interrogation. The FNCL-FIFA modal was benchmarked with simulation-based data and a user-friendly GUI was added earlier this year. Three separate codes have been submitted to the LLNL ESW system for review prior to their transfers. These include the Predictive Modeling Response toolkit, GMM-PSD firmware beta version, and the FNCL-FIFA analysis package with GUI and user documentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NewLife Nuclear - An Environmentally and Economically Minded Solution for Fusion Energy Waste Handling

Energy demand is rising as a result of innovative and increasingly more energy intensive processes coming to fruition, particularly through the recent interest in the development of AI data centers as well as manufacturing with the push towards increasing domestic manufacturing interest. Fusion energy can provide virtually limitless energy to support this increase in energy demand. Fusion energy concepts, largely classified as magnetic fusion energy (MFE) and inertial fusion energy (IFE) are being pursued, each having unique challenges to overcome before the successful deployment of electricity to the grid. Achieving fusion ignition on the National Ignition Facility, first in December 2022, and eight times since, has demonstrated the scientific viability of the IFE approach. Meanwhile, MFE test stands continue to improve confinement times, making meaningful strides in progressing towards experimental scientific viability. In each of these approaches, an emphasis is placed on generating more power out of the system than what is required to power the system. An under-researched area applicable to both IFE and MFE is handling activated waste coming out of fusion energy systems, both in the course of normal daily operations, as well as in intermittent periods as structural materials may need to be replaced. In the context of an IFE plant system, commonly discussed plant designs suggest targets are ignited within a chamber at a rate of up to one million targets per day. Between each shot, the chamber housing the ignition event will clear a portion of the chamber – resulting in a mixture of vaporized target gas, target debris, and other materials being expelled from the chamber [source]. Additionally, IFE system concepts typically discuss the modularization of plant designs, which are expected to be replaced periodically as the components degrade over time. This would result in the irradiated chamber structure materials, likely metals and alloys, needing to be removed and safely stored. In MFE plant systems, while targets are not ignited at a repetition rate with the frequent chamber clearing as is expected in IFE plant systems, it is anticipated that portions of the confinement area interfacing with the hot plasma will need to be replaced periodically. In each system, without additional investment and research into alternative processing and recycling methods, the result is storing irradiated materials, and other elements in a safe containment area until they are no longer activated. – resulting in significant waste both economic and environmental.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FNCL Enhancements Implementation (FY25 Annual Report)

The FNCL investigations team at Lawrence Livermore National Laboratory (LLNL) has completed research and development of hardware, signal processing, and analysis tools to enhance the measurement capabilities of both the current CAEN SyS VeryFuel Fast Neutron Collar (FNCL) instrument and a next-generation FNCL prototype. The team successfully built and commissioned the LLNL Demonstrator System: a fully integrated, three-panel detector system featuring higher segmentation, plastic scintillators (EJ-276D), Silicon Photomultipliers (SiPMs), no high-voltage requirement, a reduced electronic footprint, and the LLNL-developed Gaussian Mixture Model Pulse Shape Discrimination (GMM-PSD) signal processing. An extensive experimental campaign was conducted at LLNL’s Inherently Safe Subcritical Assembly (ISSA) facility using both the baseline FNCL and the LLNL Demonstrator. The campaign results validated system performance, calibration stability, and the effectiveness of advanced signal processing and analysis algorithms in a relevant environment.

and physical protection↗