Search NASA⌕ Search

SEARCH · Search NASA

Results for “operation scenarios”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Project FELICIA - A probe to survey the RHIC magnet beampipe diameter for EIC beam screen insertion

The Electron Ion Collider (EIC) Hadron Storage Ring (HSR) will reuse many of the existing superconducting (SC) magnets of the RHIC storage rings. To comply with the beamline vacuum requirements in more demanding operational scenarios, the beampipe of the RHIC SC magnets will be equipped with low surface impedance, low secondary electron yield (SEY) beam screens. The installation of these beam screens will be done with the SC magnets as installed today, thus making it a critical operation for a timely EIC installation. The beam screen inner dimensions must be maximized to retain enough aperture to the beam. On the other hand, keeping enough clearance between the screen and the beampipe is critical to ensure a smooth beam screen installation. A survey probe was designed and built to measure the inner diameter of several RHIC SC magnets in-situ and provide critical data for the beam screen design optimization. This paper reports on the design of the probe and the results from the survey campaign.

43 PARTICLE ACCELERATORS↗

Module 6: Exercise 1: Fresh Fuel Receipt for a Nuclear Facility: Nuclear Security Controls [Slides]

This module presents an operational scenario to illustrate the NMAC functions that are recommended for nuclear security. After completing this module, participants should be able to: 1) Describe the role NMAC plays in implementing recommended nuclear security practices. 2) Discuss the coordination between other departments during a primarily NMAC operation.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Characterizing and improving the performance of molten-salt-steam heat exchangers in concentrating solar power plants

Shell-and-tube heat exchangers (HXs) for steam generation from molten salts in concentrating solar power (CSP) plants experience thermal fatigue due to significant temperature gradients and inherent transient operation. Molten salt-steam HX design lifespans exceed actual lifespans, and, as a consequence, designers overpredict plant profitability and operators neglect appropriate prescriptions to optimize these lifetimes. Here, this study refines HX lifespan estimates with data benchmarked against thermal-fluid mechanical modeling of stress and accumulated fatigue. Reduced-order thermal models of the molten salt-steam, shell-and-tube evaporator and superheater predict transient temperature profiles along the two HXs salt-steam flow paths. The modeled evaporator and superheater temperature profiles enable assessment of cyclic stresses within the HX tubesheets, where molten-salt HX failures are most common. Evaporator and superheater performance data from a current 110 MW elec commercial CSP plant provide a basis for validating the reduced-order HX models. HX life predictions derived from stochastic failure distributions serve as inputs for simulating and optimizing existing plant operations. The impact of the updated lifespans on overall plant revenue depends on operating scenarios. This study suggests that typical ramping rates for a CSP plant with a high-temperature Rankine cycle result in an evaporator and superheater life of approximately 10 and 25 years, respectively, compared to the design target of 30 years. Reduced HX lifespans decrease operational plant revenue on average by 4.6-5.1%. Furthermore, there may be as many as four HX replacements over the 30-year lifetime of the plant; and, purchase agreement loss due to failure to meet contractual production requirements can have ramifications that include the risk of bankruptcy.

14 SOLAR ENERGY↗

An experimental characterization of core turbulence regimes in Wendelstein 7-X

First results from the optimized helias Wendelstein 7-X stellarator (W7-X) have shown that core transport is no longer mostly neoclassical, as is the case in previous kinds of stellarators. Instead, power balance analysis has shown that turbulent transport poses a serious limitation to the global performance of the machine. Furthermore, several studies have found this particularly relevant for ion transport, with core ion temperatures becoming clamped at relatively low values of T i ≃ 1.7 keV, except in the few scenarios in which turbulence can be suppressed. In order to understand the precise turbulent mechanisms at play and thus design improved performance scenarios, it is important to have a clear understanding of the parametric dependencies of turbulent fluctuations, and the relation between them and turbulent transport. As a first step in this direction, in this work we use Doppler reflectometry measurements carried out during a number of relevant operational scenarios to provide a systematic characterization of ion-scale ( k ⊥ ρ i ≃ 1) density fluctuations in the core of W7-X. Then, we study the relation between fluctuation amplitude and plasma profiles and show how distinct regimes can be defined for the former, depending on normalized gradients and . Furthermore, we discuss the importance of other potentially relevant parameters such as T e / T i , E r or collisionality. Comparing the different regimes, we find that turbulence amplitude depends generally on the gradient ratio η i = , as would be expected for ITG modes, with the exception of a range of discharges, for which turbulence suppression may be better explained by an ITG to TEM transition triggered by a drop in collisionality. Finally, we show a number of scenarios under which T i,core > 1.7 keV is achieved and how core fluctuations are suppressed in all of them, thus providing experimental evidence of microturbulence being the main responsible for the limited ion confinement in W7-X.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adaptive Reinforcement Learning (ARL) Control of a Multi-port Resonant Converter in UAV Systems

This study presents an adaptive reinforcement learning (ARL) control framework for a multi-port resonant converter used in hybrid unmanned aerial vehicle (UAV) power systems. The converter integrates high-frequency half-bridge input ports connected to a rectified engine–generator set and a battery energy storage system, along with a semi-bridgeless active rectifier supplying the propulsion load. A deep RL agent is trained to dynamically regulate inter-port phase-shift commands in real time based on flight conditions and load power demand. The ARL controller autonomously identifies phase-shift combinations that maximize conversion efficiency while maintaining stable and coordinated power flow, even under rapidly varying operating scenarios. This data-driven approach eliminates the need for explicit system modeling or extensive manual tuning and enables coordinated control among multiple power ports without inter-port communication. Experimental results validate that the ARL based strategy achieves reliable power sharing and consistently high-efficiency operation across diverse UAV operating conditions.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Entanglement-Enhanced Neyman-Pearson Target Detection

Quantum illumination (QI) provides entanglement-enabled target-detection enhancement, despite operating in an entanglement-breaking environment. Existing experimental studies of QI have utilized a Bayesian approach, assuming that the target is equally likely to be present or absent before detection, to demonstrate an advantage over classical target detection. However, such a premise breaks down in practical operational scenarios in which the prior probability is unknown, thereby hindering QI's applicability to real-world target-detection scenarios. In this work, we adopt the Neyman-Pearson criterion in lieu of the error probability for equally likely target absence or presence as our figure of merit for QI. We demonstrate an unconditional quantum advantage over the optimal classical-illumination protocol as benchmarked by the receiver operating characteristic, which examines detection probability versus false-alarm probability without resorting to known prior probabilities. Our work represents a critical advancement in adapting quantum-enhanced sensing to practical operational settings.

Ward, William↗

GOOML - Finding Optimization Opportunities for Geothermal Operations: Preprint

Geothermal Operational Optimization with Machine Learning (GOOML) is a transferable and extensible component-based geothermal asset modeling framework that considers complex steamfield relationships and identifies optimization prospects using a data-driven approach. We have used this framework to develop digital twins that provide steamfield operators with an operational environment to analyze and understand historical and forecasted power production, explore new steamfield configuration possibilities, and seek optimal asset management for real world applications. The GOOML modeling software is built on a generic component-based systems framework that allows for both historical and forecast analysis. A GOOML model can perform historical data-assimilation using first-principal thermodynamics to create a meaningful data model. Historical production data can then be coupled with a forecast framework to train machine-learning models of steamfield components to predict future outputs. This modeling environment enables digital exploration of steamfield design configurations and operational scenarios. GOOML digital twins have been developed for steamfields in New Zealand and the United States representing differing power generation and field conditions. These digital twins have been validated by comparing hindcast predictions against historical production data. Reinforcement learning experiments were conducted to demonstrate the ability to programmatically explore the operations space using machine learning agents. Our initial results are compelling; two to five percent increases in annual energy production were demonstrated by the GOOML models with no additional infrastructure build required. GOOML offers a new approach to geothermal operations by applying state-of-the-art machine learning algorithms, comprehensive data analytics, and interaction with digital twins. Through application of these tools, operators will realize greater availability and higher net generation which will increase the cost effectiveness of geothermal energy projects.

access↗

Structural Analysis of the US ITER ECH Transmission Line System

The electron cyclotron heating (ECH) and current drive system is one of the main plasma heating systems for ITER. It uses high-power microwave beams with the power deposition location steerable across the plasma cross section. Microwave power is conveyed via transmission lines (TLs) that run from the gyrotrons in the radio frequency building through the assembly hall and tokamak building to the ECH launchers within the tokamak vacuum vessel. The ECH system includes a vast array of interconnected TL waveguides, in-line components, and support structures.Finite element (FE) modeling provides an essential means of simulating the system, applying loads and determining deflections, rotations, forces, moments, and stresses in order to evaluate various structural and microwave transmission performance metrics. A representative FE model of the overall ECH TL system is developed in ANSYS®. This top-level model defines the centerline of the waveguide system. Waveguide segments are represented by line elements (beams and pipes) with equivalent section properties, and support structures are represented by boundary conditions. A systematic approach is used to model each ECH component with lumped masses and structurally equivalent stiffness matrices or ANSYS superelements.The top-level TL FE model is used to evaluate the various loads (thermal, vacuum, seismic, etc.) and operating scenarios. The top-level model directly calculates stresses in the straight aluminum waveguide segments. The model provides the forces and moments acting on the in-line components for detailed submodel assessments. Displacement results from the top-level analysis feed into a separate microwave performance model to help determine operational efficiency. All TL performance and thermal-structural requirements are met, as specified by the applicable codes and standards, and successfully documented in numerous technical reports and demonstrated at the final design review.

Shanmugasundaram, Aravind↗

Electron ITB formation in EAST high poloidal beta plasmas under dominant electron heating

Abstract Plasma confinement and transport in tokamaks play a crucial role in the development of high poloidal beta steady-state operation scenarios. Therefore, it is very important to study the relevant mechanism of internal transport barriers (ITBs), which can help plasmas to obtain better confinement in order to achieve higher fusion gain. This paper mainly introduces the analysis of the characteristics of electron heat transport of discharges with ITB in high β P operation regime in Experimental Advanced Superconducting Tokamak (EAST). Based on the statistical analysis of stable discharges with β P > 1.5, it is found that there is an obvious bifurcation of the normalised electron temperature gradient (ETG) ( R / L T e ) in the range of β P = 2–2.2. Then the discharges of lower β P ( β P < 2, where the value of β P is below the bifurcation threshold) and of higher β P ( β P > 2.2, where the value of β P is above the threshold) were selected for analysis. The diagnostic data provided by Thomson scattering, x-ray crystal spectrometry and charge exchange recombination spectroscopy are used to provide reliable parameter profiles and then combined with the data of external magnetic probe measurements and the polarisation interferometer diagnosis system to fully reconstruct the balance. A relevant plasma current calculation model is used to calculate and analyse the current density profiles and power deposition, and then the transport analysis is carried out. Interestingly, in the higher β P discharges, it is found that the turbulence intensity provided by the CO 2 laser collective scattering system gradually decreases and the normalised ETG R / L T e gradually increases. It is also found that the electron heat transport coefficient decreases in the discharge with higher β P and the growth rate of the electron-scale turbulence calculated by transport gyro-Landau fluid (TGLF) is significantly reduced. Meanwhile, similar conclusions are also obtained in the discharges when the β P is further increased.

Wang, Z. H. (ORCID:0009000203431036)↗

Time-Dependent Boundary Modeling to Inform Design of SPARC Diagnostic and Actuators

The purpose of this work was to inform the design of diagnostic and actuator systems for a new experimental facility for Commonwealth Fusion Systems (CFS), called SPARC [Creely2020], using time-dependent plasma boundary simulations with the Scrape Off Layer Plasma Simulator (SOLPS) code [Wiesen2015]. The SPARC tokamak is a device that aims to demonstrate fusion energy production and high-field plasma operating scenarios. The developed technologies will be incorporated into a net-electricity pilot that will demonstrate approximately 200MW of electric power. A major difference from other private industry fusion companies is the use of a standard aspect ratio, but at a high magnetic field strength, which provides a well-established physics basis and a modest extrapolation to reactor operation. Time-dependent simulations were used to inform the design of main-chamber plasma facing components, which are protected by feedback control of the heat and particle loads during high power operation. The simulations provide the timescales and magnitudes of plasma and neutral particle response useful for determining the position and operation of diagnostics and actuators that will enable control. The plasma response and phase-space diagrams also provide input into advanced model-based control schemes, which are envisioned for later SPARC operation. Model-based control can reduce the risk of component failure, which would require expensive in-situ repairs and the associated delays, by predicting the system response to actuators over a short time-horizon.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Techno-Economic Analysis of Geologically Connected Seawater Air Conditioning (GeoSWAC) Concept for District Cooling at the University of Puerto Rico at Rio Piedras

At the University of Puerto Rico at Rio Piedras, a central chilled water plant supplies cooling to several campus buildings, contributing significantly to electricity demand during daytime peak hours, particularly in the summer months. These operational challenges are exacerbated by Puerto Rico's tropical rainforest climate and a power grid vulnerable to frequent disruptions caused by hurricanes and tropical storms. This study presents a techno-economic analysis of the existing chilled water plant serving four representative campus buildings and introduces a conceptual alternative: the Geologically connected Seawater Air Conditioning (GeoSWAC) system. GeoSWAC leverages stable low temperatures of deep ocean water (~1 km depth), hydraulically connected to an inland well, to deliver cooling without the use of vapor-compression refrigeration. Using modeled annual cooling loads and chiller performance data, capital costs, energy consumption, and levelized cost of cooling (LCOC) were evaluated for both systems. While GeoSWAC showed higher capital costs than the chiller-based scenario, operational costs were significantly lower at $26k-$53k annually, resulting in a lower LCOC between $2.3/MWh and $8.2/MWh compared to $30.2/MWh-$33.6/MWh for the chiller scenario. These results suggest that the GeoSWAC system offers a promising, low-energy, and climate-resilient alternative for large-scale cooling in tropical coastal environments, with significant potential to reduce peak electricity demand and improve long-term system reliability.

15 GEOTHERMAL ENERGY↗

Techno-Economic Analysis of Geologically Connected Seawater Air Conditioning (GeoSWAC) Concept for District Cooling at the University of Puerto Rico at Rio Piedras: Preprint

At the University of Puerto Rico at Rio Piedras, a central chilled water plant supplies cooling to several campus buildings, contributing significantly to electricity demand during daytime peak hours, particularly in the summer months. These operational challenges are exacerbated by Puerto Rico's tropical rainforest climate and a power grid vulnerable to frequent disruptions caused by hurricanes and tropical storms. This study presents a techno-economic analysis of the existing chilled water plant serving four representative campus buildings and introduces a conceptual alternative: the Geologically connected Seawater Air Conditioning (GeoSWAC) system. GeoSWAC leverages stable low temperatures of deep ocean water (~1 km depth), hydraulically connected to an inland well, to deliver cooling without the use of vapor-compression refrigeration. Using modeled annual cooling loads and chiller performance data, capital costs, energy consumption, and levelized cost of cooling (LCOC) were evaluated for both systems. While GeoSWAC showed higher capital costs than the chiller-based scenario, operational costs were significantly lower at $26k-$53k annually, resulting in a lower LCOC between $2.3/MWh and $8.2/MWh compared to $30.2/MWh-$33.6/MWh for the chiller scenario. These results suggest that the GeoSWAC system offers a promising, low-energy, and climate-resilient alternative for large-scale cooling in tropical coastal environments, with significant potential to reduce peak electricity demand and improve long-term system reliability.

15 GEOTHERMAL ENERGY↗

Failure Analysis for Molten Salt Thermal Energy Storage Tanks for In-Service CSP Plants

Thermal Energy Storage (TES) is a fundamental component in concentrating solar power (CSP) plants to increase the plant's dispatchability, capacity factor, while reducing the levelized cost of electricity. In central receivers CSP plants, nitrate molten salts have been used for several years for operation temperatures of up to 565 degrees C. Despite many efforts to advance nitrate salt to higher operation temperatures (even considering a replacement with molten chloride salts) to achieve higher energy conversion efficiencies, the 565 degrees C temperature is currently considered the state-of-the art. Although molten salt tanks have been broadly deployed in commercial CSP plants worldwide, several failures have been reported in these tanks after a few months or years of operation, causing significant economic loss and mistrust in CSP technologies. Most of these failures are associated with the infancy of the technology and multiple issues related to tank design, fabrication, commissioning, and aggressive operation. A technical standard dedicated to the design and fabrication of molten nitrate TES tanks does not exist today. Current in-service molten salt tanks have been generally designed based on the American Petroleum Institute's (API) 650 and ASME Section II standards. The API 650 code provides guidelines for dimensions and fabrication for oil storage tanks up to 260 degrees C. The ASME standard provides allowable stress values for various materials at a range of temperatures and conditions. Both standards seem to be limited for molten salt TES tanks where high temperatures, thermal cycling, and transient conditions are expected. In 2020, NREL released the Concentrating Solar Power Best Practices Study (NREL/TP-5500-75763) that summarized multiple issues in CSP plants, along with potential alternatives and recommendations to address those issues based on information collected from participants representing about 80% of operating CSP plants in the world. One of the recommendations from this study was the development of accurate and validated models to evaluate the plant's transient operation, capable of capturing the effect of short-term clouds and operator response, while being flexible in being adapted to various spatial and temporal resource data. The "Failure Analysis for Molten Salt Thermal Energy Tanks for In-Service CSP Plants" project was inspired on this recommendation and was focused on (1) the development and validation of a physics-based model for a representative, commercial-scale molten salt tank, (2) performing simulations to evaluate the behavior of the tank as a function of typical plant operation conditions, (3) understanding tank failures mechanisms, (4) determining the residual stress and distortion in the tank floor after welding fabrication and evaluating their impact in the stresses developed in the tank during operation, (5) assessing the impact of key operation parameters on the temperature and stress distribution, (6) conduct a preliminary evaluation of design features to reduce stress and improve tank's reliability, and (7) estimate the tank's service life based on the stress developed under diverse operation scenarios. From the analysis conducted in the project and presented in this report, it was found that maximum stresses surpassing the yield strength point of the stainless steel (SS) 347H are developed on the tank floor near the perimeter. These large stresses are strongly influenced by the initial residual stresses and distortion of the tank floor after welding fabrication. During operation, large stresses are developed in the tank floor at high operation temperatures with large salt inventory levels during transient operation. High stresses are also related to elevated temperature gradients in the tank floor that could be attributed to insufficient mixing within the salt inflow and the salt inventory. Based on the analysis, creep is the predominant failure mechanism. However, the large stress levels could favor the plastic deformation into buckles, and crack formation due to stress relaxation cracking during cycle operation. A lifetime below 3 years was estimated for the typical plant operation conditions and a specific initial residual stress and deformation distribution of the tank floor. The estimated life agrees with the service time to failure reported in several commercial molten salt tanks. Desing and operation guidelines can be extracted from the analysis presented in this report, which could be adopted by tank manufacturers and CSP operators to advance toward an ultimate solution for tank failures by reducing residual and operational stresses to achieve a tank service life of more than 30 years. Addressing failures in molten salt TES tanks is fundamental for the CSP industry's survivability, but it is also important for other industrial and power generation applications using this technology, including nuclear and concentrating solar thermal.

14 SOLAR ENERGY↗

Early-stage Testing of Thermal Power Dispatch Simulator for Subjective Mental Workload and Evolution Time

The excess thermal energy produced by nuclear power plants (NPPs) during low electricity demands can be utilized in industrial processes, such as hydrogen production, through a thermal power dispatch (TPD) system. Initial testing of the first iteration of a single-train TPD design with a manual control mode at the Idaho National Lab (INL) revealed a high operator workload and degraded control capability. The current study evaluated the impact of an enhanced dual-train TPD design on operators’ subjective mental workload and evolution task-time while completing two operating scenarios in manual and automatic control modes. The results showed no statistically significant difference between participants’ mental workload using both control modes. Evolution time in automatic control mode took a shorter time than in manual control, with participants completing all evolutions in less than the 10-min set as the design specification limit. The shorter evolution time is discussed within the context of plant safety and operational efficiency.

Gideon, Olugbenga↗

Multiphysics Modeling of Impurity Transport for FNSF Startup Scenario with ERO2.0

This paper focuses on performing a multiphysics study using the ERO2.0 and UEDGE codes for two standard double null configurations for the Fusion Nuclear Science Facility: (a) 100% recycling and (b) 99% recycling. Results show that the main contributor to tungsten erosion along the divertor plates is impurities from the midplane waveguides. In addition, the standard high-recycling case (100% recycling) shows a significantly higher buildup of impurities along the divertor tiles during the startup phase, which can lead to a higher increase of energy loss in the plasma during steady-state operation. Last, for high recycling, anomalous diffusion can dominate over parallel field diffusion. The work performed in this study can be iteratively applied to a full operation scenario with additional physics such as those from neutrals, wall shaping, and additional external fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pathway for decarbonizing residential building operations in the US and China beyond the mid-century

With global carbon budget targets looming, residential buildings in top economies must become carbon neutral as soon as possible to reserve more emission space for emerging carbon-emitting economies. This study is the first to compare the operational decarbonization process of China’s and the United States (US) residential buildings from 2000 to 2060 by combining the end-use emission model with the decomposing structural decomposition (DSD) method and Monte Carlo simulation. The results show that from 2001 to 2020 China decarbonized 1544 mega-tons of carbon dioxide (MtCO 2 ) and the US decarbonized 1848 MtCO 2 . In the business-as-usual scenario, China will hit its emission peak in 2031 (±3) with 934 (±61) MtCO 2 , while the US will maintain a lock-in level of 736 (±133) MtCO 2 since the 2030s. In the decarbonization scenario, operational carbon neutrality for residential buildings in 2060 is promoted by an increase in clean power generation proportion, building-integrated power generation level, building electrification level, and a reduction in end-use energy intensity, which will contribute 34.4 %, 21.4 %, 14.3 %, and 29.9 % in China and 32.9 %, 33.1 %, 8.2 %, and 25.8 % in the US, respectively. Especially, building-integrated power generation in China only costs about 40 % of what it costs in the US. Besides, high-decarbonization strategies for residential building operations are proposed as references for governments to formulate targeted climate policies. Overall, this study offers data benchmarks for buildings’ carbon neutrality of top economies to further promote synergistic carbon neutrality with the buildings of emerging economies in the age of Post COP27.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Secure and Adaptive Hierarchical Multi-Timescale Framework for Resilient Load Restoration Using a Community Microgrid

Distribution system integrated community microgrids (CMGs) can partake in restoring loads during extended duration outages. At such times, the CMGs are challenged with limited resource availability, absence of robust grid support, and heightened demand-supply uncertainty. Here, this paper proposes a secure and adaptive three-stage hierarchical multi-timescale framework for scheduling and real-time (RT) dispatch of CMGs with hybrid PV systems to address these challenges. The framework enables the CMG to dynamically expand its boundary to support the neighboring grid sections and is adaptive to the changing forecast error impacts. The first stage solves a stochastic extended duration scheduling (EDS) problem to obtain referral plans for optimal resource rationing. The intermediate near-real-time (NRT) scheduling stage updates the EDS schedule closer to the dispatch time using new obtained forecasts, followed by the RT dispatch stage. To make the decisions more secure and robust against forecast errors, a novel concept called delayed recourse is designed. The approach is evaluated via numerical simulations on a modified IEEE 123-bus system and validated using OpenDSS and hardware-in-loop simulations. The results show superior performance in maximizing load supply and continuous secure distribution network operation under different operating scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low-stress creep behavior of multiple salt caverns under cyclic operations

Here, the use of multiple salt caverns for large-scale underground hydrogen storage offers a strategic solution to the growing demand for efficient and flexible energy storage, due to the inherent low permeability, high mechanical strength, and self-healing properties of the salt formation. Despite these advantages, the long-term geomechanical response of salt caverns under cyclic injection and withdrawal remains a significant challenge for ensuring operational stability. This mechanistic study highlights the critical role of low-stress creep, also known as pressure solution creep, in governing deformation of salt caverns during cyclic operations. Unlike conventional creep mechanisms that dominate under high-stress conditions, low-stress creep becomes particularly relevant under the moderate stress changes induced by repeated injection and withdrawal, which provides a previously underexplored control on cavern closure. Our three-dimensional computational model integrates the low-stress creep mechanism into the Munson–Dawson creep equation across a spectrum of operational scenarios including variations in cavern pressure cycles, injection-withdrawal frequencies, and caprock mechanical property. The low-stress creep components accelerate the cavern creep closure, which is amplified with shorter cycle frequency and larger pressure difference. Sensitivity analyses capture the complex interactions between multiple caverns and surround formations at the field scale that allows for a quantitative assessment of deformation patterns and closure rates over time and thereby informs the design and operation of sustainable underground hydrogen storage system.

Cyclic operation↗