Search NASA⌕ Search

SEARCH · Search NASA

Results for “operational data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

PV Module Operating Temperature - Data and Resources

The Photovoltaic Systems Evaluation Laboratory (PSEL) at Sandia National Laboratories (SNL) in Albuquerque, NM has an extensive test site where PV modules and other system components are deployed and monitored for testing and evaluation. For this dataset PV Performance Labs has assembled one year of measurements from the Systems Long-Term Evaluation (SLTE) project (formerly known as PV Lifetime) providing the main variables needed to investigate and validate PV module operating temperature models: irradiance, ambient temperature, wind speed and back-of-module temperature. For use with more advanced thermal modeling, an estimate of down-welling long-wave radiation is also included.

14 SOLAR ENERGY↗

Impact of Wildfires on Solar Generation, Reserves and Energy Prices

Wildfire seasons in the Western U.S. become more prolonged and intense in recent years bringing significant variability and uncertainty of solar generation. It greatly challenges the bulk power system and electricity market operation managed by California Independent System Operator (CAISO) as California leads both the wildfire records and the solar power integration. This study presents a screening-level analysis of the impact of wildfires on solar generation, operating reserve and energy prices applying historical real-world wildfire and market operation data. To the best of the authors knowledge, it is a first-of-its-kind study and will lay the foundation for market impact quantification and wildfire mitigation strategies design based on projected wildfire activities in future years.

electricity price↗

Distributed Wind Monitoring Best Practices

Accessible performance and operational data have been identified as a key enabler for distributed wind energy industry advancement. While utility-scale wind turbines benefit from reliable and continuous supervisory control and data acquisition (SCADA)-based monitoring platforms, monitoring of the U.S. fleet of distributed wind (DW) turbines has been more inconsistent, unreliable, and sometime difficult to access. Without fleet monitoring data, the industry will never understand and thus work to improve turbine under-performance and reliability issues. For the DW industry to scale up, attract investors, and boost credibility, fleetwide monitoring must be robust and reliable, select data must be made accessible to stakeholders, and the data must be in a format useful to users. To help move the industry toward a more standardized, accessible stream of monitoring data, this distributed wind monitoring best practices report attempts to cover topics including key monitoring channels, hardware, communication strategies, and accessibility. Strategic engagement with DW original equipment manufacturers (OEMs), service providers, lab and university researchers, testing organization, certification bodies, end users and solar photovoltaic (PV) monitoring experts has enabled a better understanding of the current state-of-the-art of monitoring and aided in articulating this set of best practices that will guide OEMs toward harmonized monitoring strategies, aimed at a future goal of achieving accessible performance and operational data for the entire fleet of U.S. distributed wind turbines.

17 WIND ENERGY↗

An independent analysis of bias sources and variability in wind plant pre-construction energy yield estimation methods

The wind resource assessment community has long had the goal of reducing the bias between wind plant pre-construction energy yield assessment (EYA) and the observed annual energy production (AEP). This comparison is typically made between the 50% probability of exceedance (P50) value of the EYA and the long-term corrected operational AEP (hereafter OA P50), and is known as the P50 bias. The industry has critically lacked an independent analysis of bias reduction investigated across multiple consultants to identify the greatest sources of uncertainty and variance in the EYA process and the best opportunities for uncertainty reduction. The present study addresses this gap by benchmarking consultant methodologies against each other and against operational data at a scale not seen before in industry collaborations. We consider data from 10 wind plants and evaluate discrepancies between eight consultancies in the steps taken from estimates of gross to net energy. Consultants tend to overestimate the gross energy produced at the turbines and then compensate by further overestimating downstream losses, leading to a mean P50 bias near zero, still with significant variability among the individual wind plants. Within our data sample, we find that consultant estimates of all loss categories, except environmental losses, tend to reduce the project-to-project variability of the P50 bias. The disagreement between consultants, however, remains flat throughout the addition of losses. Finally, we find that differences in consultants’ estimates of project performance can lead to differences up to $10/MWh in the levelized cost of energy for a wind plant.

Todd, Austin C.↗

The environmental footprint of data centers in the United States

Much of the world's data are stored, managed, and distributed by data centers. Data centers require a tremendous amount of energy to operate, accounting for around 1.8% of electricity use in the United States. Large amounts of water are also required to operate data centers, both directly for liquid cooling and indirectly to produce electricity. For the first time, we calculate spatially-detailed carbon and water footprints of data centers operating within the United States, which is home to around one-quarter of all data center servers globally. Our bottom-up approach reveals one-fifth of data center servers direct water footprint comes from moderately to highly water stressed watersheds, while nearly half of servers are fully or partially powered by power plants located within water stressed regions. Approximately 0.5% of total US greenhouse gas emissions are attributed to data centers. We investigate tradeoffs and synergies between data center's water and energy utilization by strategically locating data centers in areas of the country that will minimize one or more environmental footprints. Our study quantifies the environmental implications behind our data creation and storage and shows a path to decrease the environmental footprint of our increasing digital footprint.

54 ENVIRONMENTAL SCIENCES↗

FLASH: FPGA-Accelerated Smart Switches with GCN Case Study

Some communication switches, e.g., the Mellanox SHArP and those in the IBM BlueGene clusters, are augmented to process packets at the application level with fixed-function collectives. This approach, however, lacks flexibility, which limits their applicability in diverse and dynamic workloads. Recently, a new type of programmable packet processor, which uses high-level languages, e.g., P4, has emerged as possible candidates. P4-based switches, however, fall short in certain applications, including machine learning, where capabilities not currently supported by P4 are needed. These include more complex calculation, such as sparse computation and fused multiply-accumulate, data-intensive floating point operations, data reuse, and significant memory. The problem addressed here is that such a switch augmentation needs to support: a large amount of state, significant flexible compute capability, and ease of programming, all while maintaining full functionality, including ensuring high throughput, and demonstrating utility. In this work, we propose a programmable look-aside-type accelerator that can be embedded into, or attached to, existing communication switch pipelines and that is capable of processing packets at line-rate. The proposed in-switch accelerator is based on mixing an ISA (subset of RISC-V instructions) with dataflow graphs (found in CGRAs). To augment performance, vector instructions are also supported. To facilitate usability, we have developed a complete toolchain to compile user-provided C/C++ codes to appropriate back-end instructions for configuring the accelerator. While this approach is flexible enough to support various workloads, in this paper, we consider Graph Convolutional Networks (GCNs) as a case study. Experimental results show that this approach considerably improves the performance of distributed GCN applications.

Haghi, Pouya↗

Evaluation of a Surface Spill Operation to Return Adult Steelhead Overshoots Downstream of McNary Dam

This study, funded by the U.S. Army Corps of Engineers (USACE), was conducted by the Pacific Northwest National Laboratory to evaluate the efficacy of operating one Top Spill Weir (TSW) at McNary Dam outside the normal TSW operation dates for juvenile salmon passage. Of interest is whether the TSW is an effective downstream passage route for adult steelhead overshoots. Overshoots are fish which, having passed upstream at McNary Dam, must pass downstream to return to their natal stream to spawn. This report covers Fall (2019) and Spring (2020) study periods. The study design arranged the available 24 hours of TSW spill per week into weekly blocks with sub-blocks differentiated into day and night operations with TSW discharge periods of 4- and 8-hours duration. Hydroacoustic techniques were used to sample adult fish passage at the TSW and at turbine units 1 and 10. The experimental design contrasted TSW spill periods of differing duration and at different times of the day. The small number of fish detected passing the TSW, and the smaller number of fish detected passing the turbine units, were best suited to an ad hoc, exploratory approach to evaluating the effect of TSW spill. It is worthwhile to note that the operations data obtained for the fall study period had a greater than expected number of gaps and apparent anomalies that we believe were a result of how the data were aggregated. These problems are not particularly problematic for the present study, because the available data still provide a good indication of whether the TSW was operating at each point in time. TSW flows in both fall and spring data sets were able to be cleaned up using the established relationship between forebay elevation and TSW discharge rate. Additional cleanup of operations data would be needed, however, if more quantitative evaluation of dam-wide flow and passage relationships were needed. This study contrasted TSW spill periods of differing duration and at different times of the day. The small number of fish detected passing the TSW, and the smaller number of fish detected passing the turbine units were best suited to an ad hoc, exploratory approach to evaluating the effect of TSW spill. Spring adult steelhead passage numbers estimated using hydroacoustics were notably lower than during the fall study period, and that was consistent with our analysis of PIT tagged fish likely to be in the vicinity during each study period. Detections of fish in BlueView sampling areas upstream of the TSW and powerhouse were not correlated with detections of fish passing hydroacoustic sampling areas, which suggests that fish approaching the face of the dam can move around the forebay before passing. Other fish detected in the forebay in large numbers, such as shad, were able to be filtered out of steelhead passage counts and did not appear to be influencing hydroacoustic passage rate estimates. A pulse of passage at the initial TSW opening was weakly evident, but trends across 4- and 8-hour operational periods did not show a distinct decline in passage over time as TSW operation continued. Our findings do not indicate a reason to choose one 8-hour period over two 4-hour periods, or vice versa. This suggests that the duration of spill periods can be chosen based on operational or other considerations. Passage rates were consistently higher during the daytime TSW discharge periods, relative to nighttime TSW discharge periods. The experimental design of the current study used start times near dawn for day periods and near dusk for night periods.

59 BASIC BIOLOGICAL SCIENCES↗

Feasibility of Operating a Heavy-Duty Battery Electric Truck Fleet for Drayage Applications

Vehicle fleet electrification is regarded as one major pathway toward achieving energy independence and reducing air pollution and greenhouse gas emissions. Compared to light-duty and medium-duty vehicles, electrification of heavy-duty vehicles, especially Class 8 trucks, is more challenging owing to the battery size required to attain the driving range necessary for their operating goals. As drayage trucks generally have a limited daily mileage, return to a home base every night, and spend a large amount of time creeping and idling, drayage operation has been the first targeted application for Class 8 electric trucks. The feasibility of operating battery electric drayage trucks at the individual vehicle level has recently been demonstrated. However, questions remain as to whether these trucks are capable of meeting the needs of typical drayage operation at the fleet level. Here we present a feasibility analysis of operating an electric truck fleet based on real-world operation data of a diesel drayage operator in Southern California. Second-by-second activity data collected from 20 trucks in the fleet were used to estimate the corresponding electric energy consumption and the state of charge of the battery using a microscopic electric energy consumption model. An algorithm for generating tours of drayage activity from the collected data was developed and implemented. Multiple scenarios with different battery charging and truck scheduling assumptions were analyzed. The results show that 85% of the tours could be served by electric trucks if there is opportunity for charging at the home base during the time gap between consecutive tours.

33 ADVANCED PROPULSION SYSTEMS↗

Development of in-use engine speed/torque heat maps across multiple heavy-duty commercial vehicle vocations

The U.S. Department of Energy (DOE) established the SuperTruck program with the goal of achieving brake thermal efficiency (BTE) greater than or equal to 55% as demonstrated in an operational heavy-duty (HD) diesel engine at a 65-miles-per-hour (mph) cruise point. Beyond the line-haul application, HD engines operate in a wide range of speed and torque conditions that are unlikely to yield the same efficiency under real-world operation. Thereby, the in-use engine heat maps described in this paper are a valuable tool to illustrate whether the engine-efficiency “sweet spot” matches the most frequent operating conditions. In this study, NREL developed engine heat maps to quantify the important operating points for various vocations using our Fleet DNA database of commercial fleet vehicle operations data. These heat maps clearly show that high-frequency operating points vary significantly according to vehicle vocation, while only a few of them match the sweet spot. Beyond the illustration, engine in-use heat maps can also be leveraged to build up reduced-order engine-efficiency models, needed by many rapid powertrain simulations. As case studies, nine reduced-order models – including line-haul truck, transfer truck, transit bus, transit bus with compressed natural gas (CNG) engine, drayage, refuse pickup, local delivery, utility truck, and school bus with CNG engine – using a trust-region reflective algorithm to fit the on-road data extracted based on the engine in-use heat maps.

33 ADVANCED PROPULSION SYSTEMS↗

Autonomous Anomaly Detection For Continuous Streams

The code implements the Isolation Forest (IFML) algorithm within the digital twin (DT) of the AGN-201 nuclear reactor. The DT captures real-time operational data including control rod positions, reactor power, and temperature. The IFML model isolates anomalies by detecting patterns that deviate from expected operational behavior. The algorithm recursively partitions the data and assigns anomaly scores based on the isolation of rare and different events. By tuning parameters specific to the reactor’s operational data, the IFML identifies deviations such as unauthorized material insertions or reactor reactivity shifts. The system streams data using LabView and integrates with the DeepLynx data warehouse for anomaly processing.

Trevino, Eduardo↗

CLMM : a LSST-DESC cluster weak lensing mass modeling library for cosmology

ABSTRACT We present the v1.0 release of CLMM, an open source python library for the estimation of the weak lensing masses of clusters of galaxies. CLMM is designed as a stand-alone toolkit of building blocks to enable end-to-end analysis pipeline validation for upcoming cluster cosmology analyses such as the ones that will be performed by the Vera C. Rubin Legacy Survey of Space and Time-Dark Energy Science Collaboration (LSST-DESC). Its purpose is to serve as a flexible, easy-to-install, and easy-to-use interface for both weak lensing simulators and observers and can be applied to real and mock data to study the systematics affecting weak lensing mass reconstruction. At the core of CLMM are routines to model the weak lensing shear signal given the underlying mass distribution of galaxy clusters and a set of data operations to prepare the corresponding data vectors. The theoretical predictions rely on existing software, used as backends in the code, that have been thoroughly tested and cross-checked. Combined theoretical predictions and data can be used to constrain the mass distribution of galaxy clusters as demonstrated in a suite of example Jupyter Notebooks shipped with the software and also available in the extensive online documentation.

79 ASTRONOMY AND ASTROPHYSICS↗

Challenges for monitoring and data analytics in a leadership public data repository

The availability and disposition of data has assumed increasing importance in large-scale computational science. Data repositories are evolving to meet new classes of requirements: compliance with government access guidelines, support for reproducibility of experimental results, and long-term availability of data products. The Constellation public data repository at the Oak Ridge Leadership Computing Facility faces these issues while being situated in one of the most productive data centers in the world. While monitoring and operational data analysis are ingrained in the operation of the OLCF’s large-scale high performance computing platforms, data repositories do not have this history of support. Problems faced by Constellation range from data size (over 7 petabytes in current holdings) to analytic complexity (detailed curation is both absolutely necessary for many data sets and absolutely impossible for humans to accomplish in any practical manner) to deployment environment (OLCF storage resources are oriented toward the needs of the compute platforms). In this paper we describe some of the challenges for collecting monitoring and analytic data from a leadership public data repository. We also discuss various strategies we are pursuing in order to address these challenges, from manual data collection to plans for introducing machine learning-based curatorial techniques.

Widener, Patrick [ORNL] (ORCID:0000000258820816)↗

Gaining Insights in Loading Events for Wind Turbine Drivetrain Prognostics

Wind energy is one of the largest sources of renewable energy in the world. To further reduce the operations and maintenance (O&M) costs of wind farms, it is essential to be able to accurately pinpoint the root causes of different failure modes of interest. An example of such a failure mode that is not yet fully understood is white etching cracks (WEC). This can cause the bearing lifetime to be reduced to 5–10% of its design value. Multiple hypotheses are available in literature concerning its cause. To be able to validate or disprove these hypotheses, it is essential to have historic high-frequency measurement data (e.g., load and vibration levels) available. In time, this will allow linking to the history of the turbine operating data with failure data. This paper discusses the dynamic loading on the turbine during certain events (e.g., emergency stops, run-ups, and during normal operating conditions). By combining the number of specific events that each turbine has seen with the severity of each event, it becomes possible to assess which turbines are most likely to show signs of damage.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Digital Twin + AI: Control Room of the Future [Slides]

The control room functions as the central brain of the grid, essential for balancing supply and demand and ensuring moment-to-moment grid reliability. Like the human brain, which processes sensory data to make decisions, control room operators analyze operational data from power generation, transmission, and distribution to make informed decisions. Currently, decision-making primarily rests with operators due to hardware and software limitations. However, with technological advancements, Digital Twins and AI are becoming high interest points in the control room's decision-making pilot programs. NREL is developing a comprehensive decision-making platform that integrates Digital Twins, AI, and advanced visualization techniques. As this integration progresses, the role of Digital Twins will evolve from conducting automated simulations to serving as a Trustworthy AI enabler, offering verification and validation of AI-generated response for power systems or providing physics-aware synthetic data of AI pre-training.

24 POWER TRANSMISSION AND DISTRIBUTION↗