Search NASA⌕ Search

SEARCH · Search NASA

Results for “operational excellence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Underlying Substrate Effect on Electrochemical Activity for Hydrogen Evolution Reaction with Low‐Platinum‐Loaded Catalysts

Platinum is known as the best catalyst for the hydrogen evolution reaction (HER) but the scarcity and high cost of Pt limit its widespread applicability. Herein, the role of the underlying substrate on the HER activity of dispersed Pt atoms is uncovered. A direct current magnetron sputtering technique is utilized to deposit transition metal (TM) thin films of W, Ti, and Ta as underlying substrates for extremely low loading of Pt (<1.5 at%). The electrocatalytic performance of as‐synthesized samples for the HER is examined in both alkali and acidic media. The results show that despite the low loading of Pt, the Pt/TM catalysts produce hydrogen at a rate comparable to that of pristine bulk Pt. Pt/TM catalysts also display good stability with less than 5% decay in performance after 10 h of continuous HER operation. Based on the computational study, the excellent performance is attributed to the modified electronic properties of the Pt atoms, offering ideal binding energy for HER due to interaction with the underlying substrates. This work provides a robust and industry‐friendly route toward designing efficient catalytic systems for important electrochemical reactions such as HER and others.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Engineered MXene quantum dots for micro-supercapacitors with excellent capacitive behaviors

Micro-supercapacitors (MSCs) have drawn tremendous attention as promising candidates to power miniaturized portable/wearable electronics, but they still suffer from unsatisfactory electrochemical performance (e.g., insufficient energy density, mediocre rate capability), thus impeding their widespread applications. Here, a synergistic surface and structure engineering strategy achieved by downsizing to quantum dot scale, doping of heteroatoms, and introducing defects and functional groups is proposed to regulate the physicochemical properties of Ti 3 C 2 T x MXene. Encouragingly, the resulting MSCs based on defect-rich nitrogen-doped Ti 3 C 2 T x quantum dots (QDs) possess excellent electrochemical performance as demonstrated by large operating voltage (3.0 V in ionic liquid and 1.0 V in aqueous electrolyte), perfect rectangular CV shape even at 1000 V·s -1 , high volumetric capacitance of 33.1 F·cm -3 , and superior cycling stability after 10000 cycles. By employing experimental characterizations and density functional theory calculations, the remarkable performance of the MSCs is mainly due to the special chemical states as well as the unique surface and structural features of Ti 3 C 2 T x QDs, which offer abundant active sites, shorten ion diffusion pathways, promote ion/electron transports, and provide enhanced capacitance. Finally, this work provides a new strategy for the design of high-performance MSCs and a reference for the applications of MXene QDs in other energy-related fields.

42 ENGINEERING↗

Stability Analysis of Substituted Cobaltocenium [Bis(cyclopentadienyl)cobalt(III)] Employing Chemistry-Informed Neural Networks

Cobaltocenium derivatives are promising components of the anion exchange membranes due to their excellent thermal and alkaline stability under the operating conditions of a fuel cell. Here we present an efficient modeling approach of assessing the chemical stability of substituted cobaltocenium CoCp 2 + based on the computed electronic structure enhanced by machine learning techniques. Within the aqueous environment, the positive charge of the metal cation is balanced by the hydroxide anion through formation of the CoCp 2 + OH¯ complexes, whose dissociation is studied within the implicit solvent employing density functional theory. The data set of about 118 species based on 42 substituent groups characterized by a range of electron- donating (ED) and electron-withdrawing (EW) properties is constructed and analyzed. Given 12 carefully chosen chemistry-informed descriptors of the complexes and relevant fragments, the stability of the complexes is found to strongly correlate with the energies of the highest occupied and lowest unoccupied molecular orbitals, modulated by a switching function of the Hirshfeld charge. The latter is used as a measure of the electron withdrawing-donating character of the substituents. Based on this observation from the conventional regression analysis, two fully connected, feed-forward neural network (FNN) models with different unit structures, called the chemistry-informed (CINN) and the quadratic (QNN) neural networks, are developed. Both models predict the bond dissociation energies of the cobaltocenium complexes with mean relative errors less than 5.40% and average absolute errors less than 0.94 kcal/mol. The results show the potential of QNN to efficiently capture more complex relationships. Here, the concept of incorporating the domain (chemical) knowledge/insight into the neural network structure paves the way to applications of machine learning techniques with small data sets, ultimately leading to better predictive models compared to the conventional regression analysis.

36 MATERIALS SCIENCE↗

Nonsolvating Fluoroaromatic Cosolvent Enabled Long-Term Cycling of High-Voltage Lithium-Ion Batteries with Organosulfur Electrolytes

Here, the structure–activity relationships of nonsolvating cosolvents for organosulfur-based electrolyte systems were revealed. The performance of nonsolvating dilutant fluorobenzene (FB) was compared to various fluorinated ether dilutants in high-voltage electrolytes containing a concentration of 1.2 M LiPF 6 dissolved in fluoroethylene carbonate (FEC), ethyl methyl sulfone (EMS), and the dilutant. In a high-voltage and high-loading LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) full cell configuration, the organosulfur-based electrolyte containing FB dilutant enabled superior electrochemical performance compared to the electrolytes using other nonsolvating fluorinated ether formulations. Moreover, the FB-containing electrolyte exhibited the highest ionic conductivity and lowest viscosity among all organosulfur-based electrolytes containing nonsolvating dilutant. These improvements are attributed to the enhanced physical properties of electrolyte and lithium-ion mobility. Furthermore, by employing first-principles simulations, the observed suppression of side reactions at high voltage is linked to FB’s lower reactivity toward singlet dioxygen, which is likely produced at the NMC interface. Overall, FB is considered an excellent diluent that does not impede cell operation by mass decomposition at the cathode.

25 ENERGY STORAGE↗

Gradient Amine Sorbents for Low Vacuum Swing CO 2 Capture at Ambient Temperature

The growing concerns over CO 2 emissions have led to the development of various methods for CO 2 capture. CO 2 capture by amine-based sorbents has been achieved by temperature (thermal) swing adsorption (TSA) process, pressure swing adsorption (PSA) process, and temperature pressure or vacuuming swing adsorption (TPSA or TVSA) process for CO 2 capture. Amine sorbents for energy-efficient TSA, PSA, VSA, TPSA or TVSA CO 2 capture should possess a capability which allow adsorbed CO 2 to desorb and amine sorbent to be regenerated at low temperatures or low vacuums. Development of such amine sorbents would significantly decrease energy consumption and sorbent degradation during the regeneration step. The objective of this project is to develop a low vacuum swing adsorption (VSA) process for the capture of CO 2 from air. The focus is on the development of amine sorbent which allows CO 2 to adsorb in the form of weakly adsorbed CO 2 . The weakly adsorbed CO 2 species can be collected from the sorbent by applying a low vacuum at ambient temperature. Specifically, no heating (i.e., thermal energy) is needed for regeneration of amine sorbents. This novel sorbent allows VSA to be operated at ambient temperature without a significant energy demand. This process eliminates the energy-intensive heating and cooling process in temperature swing adsorption (TSA) process. Ambient temperature operation could prolong the lifetime of sorbent and minimize the maintenance cost. Extensive sorbent studies with in-situ infrared spectroscopy have revealed the modifications of conventional amine sorbents with additives can increase the fraction of weakly adsorbed CO 2 . The amine sorbents with loaded CO 2 can be regenerated in part by the following approaches: (i) mild heating to temperatures below 70 °C, (ii) flowing purging gas over modified amine sorbents at temperatures below 40 °C, (iii) vacuuming at pressure below 0.2 atm and temperatures below 40 °C. The performance of these modified amine sorbents has been tested in a 60 grams VSA unit at ambient temperatures. The results show that weakly adsorbed CO 2 which can be desorbed from modified amine sorbents with purging gas at 100 cc/min can also be evacuated at a vacuum of 1 psia at room temperature. A preliminary techno- economic analysis indicates the major cost of the VSA process with modified amine sorbents stems from the operation of vacuum pumps. Thus, developing an excellent sealing with minimum leakage for the VSA unit is the most critical task for further the development of this VSA technology.

36 MATERIALS SCIENCE↗

Heavy Flavor Physics at the sPHENIX Experiment

The sPHENIX experiment is a state-of-the-art jet and heavy flavor physics detector, which successfully recorded its first Au + Au collision data at 200 GeV at the Relativistic Heavy Ion Collider (RHIC). sPHENIX will provide heavy flavor physics measurements at RHIC, covering an unexplored kinematic region and unprecedented precision, to probe the parton energy loss mechanism, parton transport coefficients in quark–gluon plasma, and the hadronization process under various medium conditions. At the center of sPHENIX, the monolithic active pixel sensor (MAPS)-based VerTeX detector (MVTX) is a high-precision silicon pixel detector. The MVTX provides excellent position resolution and the capability of operating in continuous streaming readout mode, allowing precise vertex determination and recording a large data sample, both of which are particularly crucial for heavy flavor physics measurements. In this work, we will show the general performance of heavy-flavor hadron reconstruction. In addition, we will discuss the commissioning experience with sPHENIX. Finally, we will provide the projection of b-hadron and jet observables and discuss the estimated constraints on theoretical models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Unraveling the conundrum of electronic leakage in protonic ceramic cells: Operation-specific insights and rational design strategies

Electronic conduction through proton-conducting electrolytes significantly impairs the efficiency of protonic ceramic cells (PCCs). Here, in this study, we explore the electron and ion mixed transport properties of four common protonic ceramics, BaZr 0.8 Y 0.2 O 3-δ (BZY82), BaZr 0.7 Ce 0.2 Y 0.1 O 3-δ (BZCY721), BaZr 04 Ce 0.4 Y 0.1 Yb 0.1 O 3-δ (BZCYYb4411), and BaZr 0.1 Ce 0.7 Y 0.1 Yb 0.1 O 3-δ (BZCYYb1711). It marks the first instance of investigating these properties under operation-specific scenarios: fuel side of electrolysis cell, air side of electrolysis cell, fuel side of fuel cell, and air side of the fuel cell. BZCYYb1711 exhibits the highest ionic conductivity, but two to three times higher electronic leakage when exposed to oxygen-containing environments than the others. BZY82 exhibits approximately two times higher electronic leakage in a hydrogen-containing environment. BZCY721 demonstrates excellent ion transport numbers (~0.95) across these four operating conditions. BZCYYb4411 behaves quite similarly to BZCY721. The most challenging operating environment for all candidates is the air side of fuel cell mode. This mode leads to a high initial electronic leakage, followed by a significant increase with polarization. The probable cause for this behavior is a H 2 -free, polarization-induced reduction that leads to the formation of V$^•_O$. The electron small polaron associated with V$^•_O$ is released by the electrical field due to the Poole-Frenkel effect. ZnO and NiO sintering aids are found to be detrimental to the ionic conductivity of the electrolytes. In particular, NiO substantially lowers the ion transport number. The correlation of the operation-specific electronic leakage to full cells is discussed. It is suggested that a rational PCC design should synergistically couple BZCYYb1711 at fuel side with BZCY4411 at air side to deliver a well-balanced performance and faradaic efficiency simultaneously, and the high temperature sintering process with a NiO fuel electrode should be shortened or replaced by ultra-fast sintering techniques or using a fuel electrode scaffold-infiltration fabrication strategy.

42 ENGINEERING↗

Gas-Gap Calorimeter Sizing and Rating Tools for Heat Pipe Experimentation

Effective gas-gap calorimeter sizing and rating tools are required to design calorimeters that enable well-defined operating conditions, high cooling powers, and accurate calorimetry. The present report describes two tools utilizing Microsoft Excel and MathWorks MATLAB that enable the sizing and rating of gas-gap calorimeters with a He-Ar binary gas mixture in the gap. The Excel tools are two easy-to-use spreadsheets for calculating heat pipe operating temperature or He-Ar mole fractions given the required inputs. The MATLAB tool includes similar models with more robust solution algorithms along with sub-options for full-vacuum, static gas-gap, and forced circulation in the gas-gap. The accuracy of the developed tools were demonstrated by comparing with existing work in literature. The MATLAB tool was used for a parametric study to determine the gas-gap thickness, coolant gap thickness, coolant flow rate, and coolant inlet temperatures for the testing of a 3/4 in outer diameter heat pipe up to powers of 10 kW and temperatures of 1,000°C. The effects of heat pipe and calorimeter inner shell surface emissivities were investigated, considering the inability to control or accurately measure surface emissivities in most applications. It was found that controlling the He-Ar mole fractions provides a wide operating range for gas-gap thicknesses around ~ 0.042--0.090 in (~ 1.07--2.29 mm) for a surface emissivity range of 0.4--0.8, since conduction heat transfer is a significant fraction of the heat transfer across the gas-gap. In addition, it was found that turbulent flow in the coolant gap is needed at high input powers to prevent shell temperatures from approaching the boiling temperature of the water coolant. The parametric study resulted in choosing stainless steel tubes with an outer diameter and thickness of 1 x 0.065 in as the inner shell, and a 1-1/2 x 0.156 in as the outer shell of the calorimeter. Overall, this report presents the necessary information for the sizing and rating of gas-gap calorimeters with He-Ar mixtures for the testing of high-temperature heat pipes (~ 500--1,000°C).

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Plasma Phosphorylated Tau217 for Differentiation Between Alzheimer Disease and Frontotemporal Lobar Degeneration Subtypes Among Patients With Corticobasal Syndrome

Plasma phosphorylated tau217 (p-tau217), a biomarker of Alzheimer disease (AD), is of special interest in corticobasal syndrome (CBS) because autopsy studies have revealed AD is the driving neuropathology in up to 40% of cases. This differentiates CBS from other 4-repeat tauopathy (4RT)–associated syndromes, such as progressive supranuclear palsy Richardson syndrome (PSP-RS) and nonfluent primary progressive aphasia (nfvPPA), where underlying frontotemporal lobar degeneration (FTLD) is typically the primary neuropathology. To validate plasma p-tau217 against positron emission tomography (PET) in 4RT-associated syndromes, especially CBS. This multicohort study with 6, 12, and 24-month follow-up recruited adult participants between January 2011 and September 2020 from 8 tertiary care centers in the 4RT Neuroimaging Initiative (4RTNI). All participants with CBS (n = 113), PSP-RS (n = 121), and nfvPPA (n = 39) were included; other diagnoses were excluded due to rarity (n = 29). Individuals with PET-confirmed AD (n = 54) and PET-negative cognitively normal control individuals (n = 59) were evaluated at University of California San Francisco. Operators were blinded to the cohort. Plasma p-tau217, measured by Meso Scale Discovery electrochemiluminescence, was validated against amyloid-β (Aβ) and flortaucipir (FTP) PET. Imaging analyses used voxel-based morphometry and bayesian linear mixed-effects modeling. Clinical biomarker associations were evaluated using longitudinal mixed-effect modeling. Of 386 participants, 199 (52%) were female, and the mean (SD) age was 68 (8) years. Plasma p-tau217 was elevated in patients with CBS with positive Aβ PET results (mean [SD], 0.57 [0.43] pg/mL) or FTP PET (mean [SD], 0.75 [0.30] pg/mL) to concentrations comparable to control individuals with AD (mean [SD], 0.72 [0.37]), whereas PSP-RS and nfvPPA showed no increase relative to control. Within CBS, p-tau217 had excellent diagnostic performance with area under the receiver operating characteristic curve (AUC) for Aβ PET of 0.87 (95% CI, 0.76-0.98; P < .001) and FTP PET of 0.93 (95% CI, 0.83-1.00; P < .001). At baseline, individuals with CBS-AD (n = 12), defined by a PET-validated plasma p-tau217 cutoff 0.25 pg/mL or greater, had increased temporoparietal atrophy at baseline compared to individuals with CBS-FTLD (n = 39), whereas longitudinally, individuals with CBS-FTLD had faster brainstem atrophy rates. Individuals with CBS-FTLD also progressed more rapidly on a modified version of the PSP Rating Scale than those with CBS-AD (mean [SD], 3.5 [0.5] vs 0.8 [0.8] points/year; P = .005). In this cohort study, plasma p-tau217 had excellent diagnostic performance for identifying Aβ or FTP PET positivity within CBS with likely underlying AD pathology. Plasma P-tau217 may be a useful and inexpensive biomarker to select patients for CBS clinical trials.

59 BASIC BIOLOGICAL SCIENCES↗

Stable and selective catalysts for propane dehydrogenation operating at thermodynamic limit

Hitting the limits on propene synthesis The greater abundance of propane from shale gas has spurred efforts to use it as a propylene feedstock. Direct dehydrogenation catalysts consisting of platinum–tin alloy nanoparticles supported on alumina often must run with hydrogen dilution to avoid carbon buildup and excess tin to avoid alloy segregation. Motagamwala et al. report that platinum–tin nanoparticles interact more weakly with a silica support and the metals thus do not segregate. The use of undiluted reactants allowed the reaction to run near the thermodynamically limit of about 67% conversion with a selectivity to propylene of more than 99%. This catalyst also does not build up carbon and could run up to 30 hours without deactivation. Science , abg7894, this issue p. 217

Science & Technology - Other Topics↗

3D Source Reconstruction Using Coded Aperture Gamma-Ray Imaging

Recent measurements with coded-aperture imagers demonstrate material mass determination in a holdup setting to an accuracy within a few percent. This capability is of particular interest to the Surplus Plutonium Disposition (SPD) project, which aims to dilute and dispose of surplus plutonium oxide. Gamma-ray imagers can be used to determine holdup without interrupting normal operations. In this work, we examine techniques for 3D source localization and mass determination using gamma-ray imagers. Coded-aperture imagers provide excellent source localization within the 2D image plane; however, multiple imagers operating in tandem are necessary to identify source location in 3D space. A Maximum Likelihood Expectation-Maximization (MLEM) method for fitting detector mappings is a powerful tool for accomplishing this task. MLEM allows 3D source localization to be simultaneously constrained using multiple gamma-ray imagers by constructing the basis for the MLEM fit using detector mappings from different detector locations stitched together. Each of these basis points represents a singular response from a source in 3D space and is generated using Monte Carlo simulations of sources placed individually at different locations throughout the imager’s field of view. Additionally, implementing knowledge of the physical equipment in the simulations of the glovebox used for the SPD project incorporates attenuation effects that are needed to calculate material holdup.

Laminack, Alex↗

Fast Photoactuation Driven by Supramolecular Polymers Integrated into Covalent Networks

Abstract The design of robotic soft matter capable of emulating the complex movements of living organisms such as mechanical actuation, shape transformation, and autonomous translation remains a grand challenge in soft materials science. Functionalized hydrogels are excellent candidates for such materials since they can operate in water and are highly responsive to their environment, but their response times can be slow. This work investigates fast photoactuation of hybrid bonding hydrogels composed of peptide amphiphile (PA) supramolecular nanofibers bonded covalently to merocyanine‐based (MCH + ) photoresponsive networks. By incorporating ionizable acrylic acid (AA) co‐monomers in these networks, photoactuation at nearly neutral pH is observed, which in turn enables a new mechanism to accelerate the response by triggering the bundling of supramolecular nanofibers by rapid proton exchange reactions. Furthermore, this rapid response and its consequent large shape transformations lead to hydrogels capable of spontaneously tracking external light sources inspired by pedicellariae, defensive organs present in echinoderms like the starfish and the sea urchin. This work suggests that hybrid bonding polymers (HBPs), which leverage the interplay between supramolecular assemblies and covalent networks, offer novel strategies to design rapidly actuating soft robotic materials.

Cezan, S. Doruk↗

DOME: Directional medical embedding vectors from Electronic Health Records

Motivation: The increasing availability of Electronic Health Record (EHR) systems has created enormous potential for translational research. Recent developments in representation learning techniques have led to effective large-scale representations of EHR concepts along with knowledge graphs that empower downstream EHR studies. However, most existing methods require training with patient-level data, limiting their abilities to expand the training with multi-institutional EHR data. On the other hand, scalable approaches that only require summary-level data do not incorporate temporal dependencies between concepts. Methods: We introduce a DirectiOnal Medical Embedding (DOME) algorithm to encode temporally directional relationships between medical concepts, using summary-level EHR data. Specifically, DOME first aggregates patient-level EHR data into an asymmetric co-occurrence matrix. Then it computes two Positive Pointwise Mutual Information (PPMI) matrices to correspondingly encode the pairwise prior and posterior dependencies between medical concepts. Following that, a joint matrix factorization is performed on the two PPMI matrices, which results in three vectors for each concept: a semantic embedding and two directional context embeddings. They collectively provide a comprehensive depiction of the temporal relationship between EHR concepts. Results: We highlight the advantages and translational potential of DOME through three sets of validation studies. First, DOME consistently improves existing direction-agnostic embedding vectors for disease risk prediction in several diseases, for example achieving a relative gain of 5.5% in the area under the receiver operating characteristic (AUROC) for lung cancer. Second, DOME excels in directional drug-disease relationship inference by successfully differentiating between drug side effects and indications, correspondingly achieving relative AUROC gain over the state-of-the-art methods by 10.8% and 6.6%. Finally, DOME effectively constructs directional knowledge graphs, which distinguish disease risk factors from comorbidities, thereby revealing disease progression trajectories. The source codes are provided at https://github.com/celehs/Directional-EHRembedding.

60 APPLIED LIFE SCIENCES↗

Realization of a gas puff imaging system on the Wendelstein 7-X stellarator

A system for studying the spatiotemporal dynamics of fluctuations in the boundary of the W7-X plasma using the “Gas-Puff Imaging” (GPI) technique has been designed, constructed, installed, and operated. This GPI system addresses a number of challenges specific to long-pulse superconducting devices, such as W7-X, including the long distance between the plasma and the vacuum vessel wall, the long distance between the plasma and diagnostic ports, the range of last closed flux surface (LCFS) locations for different magnetic configurations in W7-X, and management of heat loads on the system’s plasma-facing components. The system features a pair of “converging–diverging” nozzles for partially collimating the gas puffed locally ≈135 mm radially outboard of the plasma boundary, a pop-up turning mirror for viewing the gas puff emission from the side (which also acts as a shutter for the re-entrant vacuum window), and a high-throughput optical system that collects visible emission resulting from the interaction between the puffed gas and the plasma and directs it along a water-cooled re-entrant tube directly onto the 8 × 16 pixel detector array of the fast camera. The DEGAS 2 neutral code was used to simulate the Hα (656 nm) and HeI (587 nm) line emission expected from well-characterized gas-puffs of H2 and He and excited within typical edge plasma profiles in W7-X, thereby predicting line brightnesses used to reduce the risks associated with system sensitivity and placement of the field of view. Operation of GPI on W7-X shows excellent signal-to-noise ratios (>100 at 2 Mframes/s) over the field of view for minimally perturbing gas puffs. The GPI system provides detailed measurements of the two-dimensional (radial and poloidal) dynamics of plasma fluctuations in the W7-X edge and scrape-off layer and in and around the magnetic islands outside the LCFS that make up the island divertor configuration employed on W7-X.

Instruments & Instrumentation↗

Feasibility of fusion plasma burn control via real-time, sub-divertor neutral gas isotopic and compositional analysis

The ability to provide fusion burn control without requiring physical access through the first wall and fuel breeding blankets, would be vital for any future, magnetically confined fusion power reactor. A multi-sensor, fusion fuel cycle exhaust, neutral gas analysis system on JET, capable of delivering real time data, and accessing only the sub-divertor region, provides an excellent example of such capability. Optimized for and operated during the deuterium–tritium experimental campaigns 2 and 3 (DTE2, DTE3), it is proving valuable for planning to explore fusion reactor burn control in ITER with a comparable diagnostic system called the Diagnostic Residual Gas Analyzer (DRGA). This paper aims to show feasibility of developing model-based controllers for ITER and next generation, reactor-relevant devices, by building both on the empirical experience in JET-DTE2, and on the already emerging experience on developing such models specifically for ITER. The paper begins with a specific use-case from JET-DTE2, pertaining to the observed sensitivity of the fusion neutron yield on the concentration of isotopic helium-3 ( 3 He), with data from one of the high-performance DT shots exhibited with emphasis on the 3 He measurement via the sub-divertor. Then, a first model is developed and then explored with simulations that aim to discover how well the controllers in the model react to either insufficient levels of 3 He or excessive levels of 3 He. The simulations then explore potential impact from a delay in the measurement (or the response) that would be comparable to the ∼1 s, conductance limited response for the ITER DRGA system, currently in its final design. The simulations show that control is feasible, and that its effectiveness is not significantly impacted by such delay.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Excitation spectra of quantum matter without quasiparticles. I. Sachdev-Ye-Kitaev models

Here, we study the low-frequency spectra of complex Sachdev-Ye-Kitaev models at general densities. The analysis applies also to SU(M) magnets with random exchange at large M. The spectral densities are computed by numerical analysis of the saddle-point equations on the real frequency ω axis at zero temperature T. The asymptotic low-ω behaviors are found to be in excellent agreement with the scaling dimensions of irrelevant operators which perturb the conformally invariant critical states. Of possible experimental interest is our computation of the universal spin spectral weight of the SU(M) magnets at low ω and T; this includes a contribution from the time reparametrization mode, which is the boundary graviton of the holographic dual. This analysis is extended to a random t-J model in the following paper [M. Tikhanovskaya et al., following paper, Phys. Rev. B 103, 075142 (2021)].

36 MATERIALS SCIENCE↗

Performance Optimization for Relative-Error-Bounded Lossy Compression on Scientific Data

Scientific simulations in high-performance computing (HPC) environments generate vast volume of data, which may cause a severe I/O bottleneck at runtime and a huge burden on storage space for postanalysis. Unlike traditional data reduction schemes such as deduplication or lossless compression, not only can error-controlled lossy compression significantly reduce the data size but it also holds the promise to satisfy user demand on error control. Pointwise relative error bounds (i.e., compression errors depends on the data values) are widely used by many scientific applications with lossy compression since error control can adapt to the error bound in the dataset automatically. Pointwise relative-error-bounded compression is complicated and time consuming. In this article, we develop efficient precomputation-based mechanisms based on the SZ lossy compression framework. Our mechanisms can avoid costly logarithmic transformation and identify quantization factor values via a fast table lookup, greatly accelerating the relative-error-bounded compression with excellent compression ratios. In addition, we reduce traversing operations for Huffman decoding, significantly accelerating the decompression process in SZ. Experiments with eight well-known real-world scientific simulation datasets show that our solution can improve the compression and decompression rates (i.e., the speed) by about 40 and 80 p, respectively, in most of cases, making our designed lossy compression strategy the best-in-class solution in most cases.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Implementation of the Windowed Multipole Method in Shift

The windowed multipole (WMP) method has been implemented in the Shift Monte Carlo (MC) radiation transport code with support for both CPU and GPU execution. With this method, small WMP data libraries (~100 MB) can be used to accurately Doppler broaden cross sections to arbitrary temperatures “on the fly” during an MC simulation. This approach yields significant memory savings relative to traditional methods, making it ideal for high-fidelity analysis such as coupled multiphysics simulations. This document provides the exact forms of the WMP equations used by Shift, as well as a detailed description of the structure of WMP HDF5 data files provided by the Massachusetts Institute of Technology (MIT). The Shift implementation has been validated against the OpenMC radiation transport code, with excellent agreement demonstrated for 70 nuclides across an operative range of temperatures. CPU and GPU performance testing using a small module reactor (SMR) problem demonstrated that this method decreases the neutron tracking rate by a factor of ~2 on the Summitdev machine. A new set of WMP data being developed in-house will employ novel methods to improve tracking rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗