Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical flow cell”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

76 records · Page 5

The right conditions for high-precision dynamic temperature and heat capacity measurement via pyrometry and conductivity

The pursuit of accurate bulk temperature T under extreme conditions has been a long-standing goal of the high pressure science community, complicated by a lack of data to inform models. To reach these extremely high-pressure, high-temperature (high P − T) conditions, a combination of dynamic and heated static experiments (e.g., diamond or gem anvil cel experiments) are used. For example, in a diamond anvil cell (DAC) experiment, a sample placed in the DAC is first pressurized. Following pressurization, the sample T is increased either by heating the entire DAC (usually using resistive heating, and limited to ∼1000K) or by applying intense laser power to the sample surfaces. In a dynamic experiment, the process of pressurizing the sample also heats it. In the case of shock physics experiments, such heating is substantial, easily reaching thousands of Kelvin; in our work we have seen T ∼17000K. Most methods of measuring temperature at ambient are not compatible with experiments under these high-pressure, high-temperature conditions: thermocouples break, melt, or have conductivity properties that differ from ambient where they are calibrated; thermometers would melt; both are too slow. As a result most methods are based on non-contact techniques such as x-ray diffraction broadening, neutron scattering, or optical methods. Of these, optical methods using the visible and near-infrared region of the spectrum are the most commonly used as the sources and detectors are readily available. In the case of optical methods the optical depth, and therefore the measurement location, is limited to the surface. When a window or anvil material is used, heat flows from the sample into the window/anvil. Likewise, if the sample undergoes a change in thermodynamic state, such as expansion upon release, different T may be expected. As a result, the surface or apparent temperature T app measurement will differ from the bulk or interior temperature that is desired. This surface measurement must be related to the bulk measurement using thermal transport models and material models. While it is tempting to conclude that one should just use x-ray methods that directly probe the interior, even these methods have been shown to depend on thermal transport and material models. Regardless of the method used to create the high P − T condition, therefore, we must understand the role of thermal transport and material models upon our interpretation of the T measurement, as well as the errors and uncertainties associated with the choice of models used in the analysis. This is a substantial area of research and this paper is by no means a complete survey of the relevant sources of uncertainty. For example, we have yet to begin to address alternate transport models in a detailed manner (e.g., Tan-Ahrens), or the many models that use additional layers to approximate melting, turbulence, or epitaxial phenomena). Likewise, we have not explored the impact upon uncertainty of thermal models that use temperature-dependent thermal transport coefficients, or the wide range of material models that can be applied. Instead, this paper focuses on using one simple model, the Urtiew-Grover model, to understand the sources of error in T measurement so that we may identify how best to focus future research efforts to return the best improvements and avoid working on over-optimizing a single type of measurement. To this end, we work through some of the best and worst case scenarios for T measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transforming energy using quantum dots

Transforming and directing the flow of energy from one form (e.g., sunlight, electricity, etc.) to other useful forms of energy (e.g., electricity, chemical bonds, light, etc.) in an efficient and controllable manner is critical to meet the increasing energy demands and build a sustainable society. In search of such energy mediators, colloidal semiconductor nanocrystals, or quantum dots (QDs) are promising building blocks for building and designing systems that can efficiently capture light and convert and direct that energy into other useful forms of energy. In this work, we summarize recent advances using QDs in energy conversion architectures with the express goal of converting optical energy to other forms of energy, including electricity (i.e., photovoltaics) , photons with different energies (i.e., photo up- or downconversion), and chemical bonds (i.e., photocatalysis). The advantages of employing QDs over molecular chromophores in absorbing and then directing and converting optical energy are highlighted. Finally, we discuss ongoing challenges as well as unique opportunities associated with the use of QDs for transforming energy.

30 DIRECT ENERGY CONVERSION↗

Laboratory Demonstration of Collisionless Blob Formation via Laser-Produced Plasma Self-Focusing

Strongly localized, propagating plasma density structures that are capable of crossing magnetic field lines are known as “blobs.” Here we demonstrate a novel mechanism for the formation and propagation of an ion gyroradius-scale blob-cavity structure at the interface between a super-Alfvénic laser-produced plasma (LPP) and an ambient magnetized plasma. The LPP self-focuses along the edge of the diamagnetic cavity which results in a dense, jetlike structure as compared to ballistic motion. This collimated flow couples momentum to the ambient plasma through a collisionless process known as Larmor coupling. The Larmor electric fields locally displace the ambient ions forming a blob above the LPP flow. In the region between a gyrating blob and collimated LPP flow, a secondary cavity of expelled magnetic field forms. In conclusion, these findings are supported by particle-in-cell simulations that replicate the blob formation mechanism and provide insight to similar processes in space, astrophysical, and laboratory settings characterized by ion kinetic scales.

Fluorescence spectroscopy↗

Coherent Transfer of Lattice Entropy via Extreme Nonlinear Phononics in Metal Halide Perovskites

Entropy transfer in metal halide perovskites, characterized by significant lattice anharmonicity and low stiffness, underlies the remarkable properties observed in their optoelectronic applications, ranging from solar cells to lasers. The conventional view of this transfer involves stochastic processes occurring within a thermal bath of phonons, where the lattice arrangement and energy flow from higher- to lower-frequency modes. Here, we unveil a comprehensive chronological sequence detailing a conceptually distinct coherent transfer of entropy in a prototypical perovskite CH 3 NH 3 Pbl 3 . The terahertz periodic modulation imposes vibrational coherence into electronic states, leading to the emergence of mixed (vibronic) quantum beat between approximately 3 and 0.3 THz. We highlight a well-structured bidirectional time-frequency transfer of these diverse phonon modes, each developing at different times and transitioning from high to low frequencies from 3 to 0.3 THz, before reversing direction and ascending to around 0.8 THz. First-principles molecular dynamics simulations disentangle a complex web of coherent-phononic coupling pathways and identify the salient roles of the initial modes in shaping entropy evolution at later stages. Capitalizing on coherent entropy transfer and dynamic anharmonicity presents a compelling opportunity to exceed the fundamental thermodynamic (Shockley-Queisser) limit of photoconversion efficiency and to pioneer novel optoelectronic functionalities. Published by the American Physical Society 2024

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗