Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical separation techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Aerosol Optical Tweezers Elucidate the Chemistry, Acidity, Phase Separations, and Morphology of Atmospheric Microdroplets

Aerosol particles represent unique chemical environments because of their high surface area-to-volume ratio that promotes the effects of interfacial chemistry in confined environments. Properties such as viscosity, diffusivity, water content, pH, and morphology—following liquid–liquid phase separation—can strongly alter how a particle interacts with condensable vapors and reactive trace gases, thus modifying its continual evolution and environmental effects. Our understanding of this chemical evolution of atmospheric particulate matter and its environmental impacts is largely limited by our ability to directly observe how these critical particle properties respond to the addition or reactive uptake of new chemical components. Aerosol optical tweezers (AOT) stably trap particles in focused laser beams, providing positional control and the retrieval of many of these critical properties required to understand and predict the chemistry of aerosolized microdroplets. The analytical power of the AOT stems from the retrieval of the cavity-enhanced Raman spectrum induced by the trapping laser. Analysis of the whispering gallery modes (WGMs) that resonate as a standing wave around the droplet’s interface, provide high accuracy measurements of the droplet’s size, refractive index (and thus a measurement of composition), and can distinguish between core–shell, partially engulfed, and homogeneous morphologies. In this study, we have advanced the ability to determine the properties of the core and shell phases in biphasic droplets, including obtaining high-accuracy pH measurements. These capabilities were applied to perform AOT physical chemistry experiments on authentic secondary organic aerosol (SOA) produced directly in the AOT chamber by ozonolysis of terpene vapors. The propensity of the SOA to phase separate as a shell from a wide range of nonpolar to polar core phases was observed, along with the discovery of a stable emulsified state of SOA particles in an aqueous salt droplet. Micron-thick SOA shells did not impede the gain or loss of water or squalane from the core to the surrounding air, indicating no significant diffusional limitations to condensational growth or partitioning even under dry conditions. These experiments formed the foundation of a new framework that predicts how the phase-separated morphology of complex aerosols containing organic carbon evolves during continual atmospheric oxidation processes. Increases in oxidation state will quickly drive conversion from a partially engulfed to core–shell morphology that has dramatically different chemical reactivity since the core phase is completely concealed by the shell. The recent advances in the experimental capabilities of the AOT technique such as presented here enable novel experimental methodologies that provide insights into the chemistry and multidimensional properties of aerosol microdroplets, and how these coevolve and respond to continual chemical reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The SuperCam Instrument Suite on the NASA Mars 2020 Rover: Body Unit and Combined System Tests

The SuperCam instrument suite provides the Mars 2020 rover, Perseverance, with a number of versatile remote-sensing techniques that can be used at long distance as well as within the robotic-arm workspace. These include laser-induced breakdown spectroscopy (LIBS), remote time-resolved Raman and luminescence spectroscopies, and visible and infrared (VISIR; separately referred to as VIS and IR) reflectance spectroscopy. A remote micro-imager (RMI) provides high-resolution color context imaging, and a microphone can be used as a stand-alone tool for environmental studies or to determine physical properties of rocks and soils from shock waves of laser-produced plasmas. SuperCam is built in three parts: The mast unit (MU), consisting of the laser, telescope, RMI, IR spectrometer, and associated electronics, is described in a companion paper. The on-board calibration targets are described in another companion paper. Here we describe SuperCam’s body unit (BU) and testing of the integrated instrument. The BU, mounted inside the rover body, receives light from the MU via a 5.8 m optical fiber. The light is split into three wavelength bands by a demultiplexer, and is routed via fiber bundles to three optical spectrometers, two of which (UV and violet; 245–340 and 385–465 nm) are crossed Czerny-Turner reflection spectrometers, nearly identical to their counterparts on ChemCam. The third is a high-efficiency transmission spectrometer containing an optical intensifier capable of gating exposures to 100 ns or longer, with variable delay times relative to the laser pulse. This spectrometer covers 535–853 nm ( $105\text{--}7070~\text{cm}^{-1}$ Raman shift relative to the 532 nm green laser beam) with $12~\text{cm}^{-1}$ full-width at half-maximum peak resolution in the Raman fingerprint region. The BU electronics boards interface with the rover and control the instrument, returning data to the rover. Thermal systems maintain a warm temperature during cruise to Mars to avoid contamination on the optics, and cool the detectors during operations on Mars.Results obtained with the integrated instrument demonstrate its capabilities for LIBS, for which a library of 332 standards was developed. Examples of Raman and VISIR spectroscopy are shown, demonstrating clear mineral identification with both techniques. Luminescence spectra demonstrate the utility of having both spectral and temporal dimensions. Finally, RMI and microphone tests on the rover demonstrate the capabilities of these subsystems as well.

47 OTHER INSTRUMENTATION↗

Emission spectroscopy with coded apertures for enhanced dimensionality

A coded aperture is used to demonstrate emission spectroscopy from multiple one-dimensional measurement locations simultaneously with a single camera. The coded aperture mask has several columns of periodic apertures, each with a unique spatial frequency. Light transmitted through all mask columns is detected through an imaging spectrometer. Dispersed light from the various mask columns overlaps on the spectrometer camera but is separated using Fourier-domain filtering using the known spatial frequencies of the mask. As the coded aperture is placed at an image plane, each Fourier-filtered spectrogram comes from a unique one-dimensional measurement location. This technique represents a significant increase in the amount of spatially and spectrally resolved emission data available using a single emission spectrometer and camera at the expense of some spatial resolution due to the Fourier filtering. This instrument is particularly useful for studying transient, non-repeating events. Megahertz-rate emission spectroscopy from five one-dimensional measurement locations is demonstrated with explosive fireballs using a single camera. Optical design parameters and instrument performance characteristics are discussed.

42 ENGINEERING↗

Simultaneous imaging of two-phase velocities in particle-laden flows by two-color optical phase discrimination

In this Letter, we present a particle image/tracking velocimetry (PIV/PTV) technique for simultaneous velocity measurement of both fluid and particle phases, adopting newly developed optical phase discrimination methods and novel optical particles. Spherical acrylic (PMMA) particles of diameter ∼ <#comment/> O ( 100 µ <#comment/> m ) were used as the particle phase, while fine B A M : E u 2 + phosphors of diameter ∼ <#comment/> O ( 1 µ <#comment/> m ) were used as the fluid tracer. Under Nd:YAG 355 nm laser excitation, both the laser-induced fluorescence (LIF) from PMMA and laser-induced phosphorescence (LIP) from B A M : E u 2 + provided sufficiently strong signals for PIV imaging with two non-intensified cameras and were clearly separable for phase discrimination using spectral filters and temporal profiles. The advantages of the PIV/PTV method include the relatively low cost of B A M : E u 2 + phosphors, high sphericity and narrow size distribution of PMMA particles with LIF emission, and direct optical discrimination eliminating artifacts, while requiring much less computational capacity for PIV/PTV processing of complex particle-laden flows.

Bi, Xiaopeng (ORCID:0000000190847325)↗

Trace Chemical Detection Using Intercalated MXenes as a Signal Enhancing Substrate in Optical Probes

MXenes are 2D materials composed of layered transition metal nitrides or carbides. These materials are synthesized by HF exfoliation from MAX phases (Ti{sub 3}AlC{sub 2}). The 2D nanomaterial was synthesized by the removal of the 'A' element, resulting in a Mxene product (Ti{sub 3}C{sub 2}). MXenes have the general formula M{sub n+1}X{sub n}T{sub x}, where M is an early transition metal, X is Carbon and/or Nitrogen, and T accounts for surface terminated functional groups such as Fluoride, hydroxyl, and oxygen. These materials have very unique properties, similar to graphene, that allows them to be applied in a variety of trace detection techniques including surface-enhanced Raman spectroscopy (SERS). MXenes have also been demonstrated to selectively uptake uranyl ion, UO{sub 2}{sup 2+}. If this property can be combined with SERS or fluorescence detection, it may be possible to use MXenes as the basis for an alternative method to kinetic phosphorescence analysis (KPA) for trace uranyl measurements. Objectives: To confirm that MXene Nano materials are suitable substrates for SERS and sensor development by enhancing Raman signaling. To determine if certain MXene preparation methods yield materials that are more suitable for trace sensing methods. To determine uranyl uptake properties of these MXene materials and test them for analytical signals. Sample Preparation: Preparation of Ti{sub 3}C{sub 2}MXene (at FSU). MXenes were prepared by etching Al from Ti{sub 3}AlC{sub 2} (MAX phase)material. Two etching techniques yield different MXene products: LiF/HCl: Milder reaction, larger MXene flakes. HF: Harsher reaction, smaller flakes, larger layer separation. Products washed to remove etchant, vacuum filtered, and dried. Dried MXene flakes are air-stable. Film preparation for sensor testing (at SRNL): Suspend powder in diH{sub 2}O, purge with Ar, sonicate for 30 min. Centrifuge and collect supernate with suspended particles. Observed LiF-etched Mxene yielded a higher density of particles and darker collected solution. Drop-cast (4 ml) supernate onto slides and dried with Ar. For Rhodamine B (RhB) testing, drop-cast 4 ml drops onto Mxene spots and dried with Ar. Scanning Electron Microscopy conditions: 10 kV Beam energy, high vacuum; Working distance of 8 mm; beam penetration depth appx. 4 microns, beam spot size appx. 2 nanometers. Results: Detection of aluminum correlates with bright spots on image. Presence of aluminum shows that LiF/HCl etching was less thorough than HF etching. Trace Cl detection in LiF images suggests incomplete rinsing. HF has smaller feature size, more layer structure, and increased homogeneity, consistent with expectations. Macroscopic Raman spectroscopy measurements: 532 nm excitation, ∼50 mW with a ∼100 micron spot size (InPhotonics RPB probe). Kaiser Optical Holospec f/1.8 spectrometer with cooled (-60 deg.C) Andor iDus OE420 CCD. LiF 1x supernate showed good signal for trace measurements of Rhodamine B. HF and 1/4x LiF supernates showed little Mxene or Rhodamine B signal. Low deposition densities led to excess background signal from glass slides. For LiF film, response is linear with Rhodamine B concentration over range tested. Will retest with Raman microscope (∼1 micron spot size) to characterize SERS of more dilute LiF and HF etched Mxenes. Conclusions: The LiF etched material was more suitable for macroscopic SERS measurements because it was more concentrated, resulting in a thicker film than the HF etched Mxene and diluted LiF sample. However, the other materials may give greater SERS enhancements, which we hope to determine from measurements with the Raman microscope. From characterization with SEM we concluded that the HF etched Mxene is more uniform/homogenous and has smaller particle size than the LiF etched Mxene. There is still aluminum present in both samples indicating that etching wasn't complete, but the removal of the aluminum was more efficient in the HF method. Path Forward: Observe SERS with Raman microscopy, to obtain better signals for the more diluted samples and be able to compare enhancement effects for the different MXenes. Characterize uranyl sorption into MXene films and test Raman and fluorescence signals. Revisit the etching conditions to improve removal of aluminum. FSU and SRNL will continue to collaborate to create and characterize different Mxene materials and test their usefulness for sensor applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fully Distributed Multi-Material Magnetic Sensing Structures for Multiparameter DAS Applications

This dissertation demonstrates the first of its kind distributed magnetic field sensor based on a fiber optic distributed acoustic sensing (DAS) scheme. Ferromagnetic nickel and Metglas® were dispersed internally within a fiber optic preform and then drawn on an in-house fiber optic draw tower to lengths in the kilometers. Due to the close proximity of the ferromagnetic metals and fiber optic core, the magnetostrictive strain response of the ferromagnetic materials when exposed to a magnetic field would perturbate within the fiber cladding and transfer that strain, internally, to the fiber optic core. Strain resulting from the magnetostrictive effect allows the DAS based sensor to accurately translate strain into readable magnetic field data. Due to the high sensitivity seen in this sensor design, multiparameter sources, acoustic and magnetic fields, were tested and validated and a three dimensional magnetic-field vector sensor was proposed. Numerical analysis of the novel sensor design was first implemented using COMSOL Multiphysics, where inputs such as magnetostrictive element shape, size, distance, and number were first investigated. Upon optimizing system constraints, the sensor design was further modified such that single mode operation was consistent across multiple fiber draws while retaining high strain transfer from the ferromagnetic elements to the fiber optic core. Ferromagnetic material selection was evaluated as a function of the saturation magnetostriction constants and a total of 4 modules were used to fully characterize the complex physics involved in this sensor design. All fabrication and testing were performed in-house using a full scale 3-story fiber draw tower and custom environmental testing stations to imitate naturally occurring events such as magnetic or acoustic point sources. A unique stacking method was used to embed ferromagnetic nickel and Metglas® into a fiber optic preform which when combined with a custom fiber draw process resulted in consistent multi-material fibers drawn to lengths of 1-km. In-house testing facilities included different types of electromagnetic generators, in addition to a soil test bed, and an outdoor test bed which allowed 100 meters of fiber to be tested simultaneously. All tested sensors demonstrated high strain transfer capabilities on the order of 0.01-10 μϵ depending on the materials used, ferromagnetic rod number, and core to metal spacing. Due to the sensitivity of the system the difference between AC and DC was distinct, and directional magnetostriction was studied. Transverse and longitudinal magnetic wave propagation was controlled through a solenoid and rectangular Helmholtz coil, both built in-house. A three-dimensional magnetic field vector sensor was proposed due to the success of the magnetic field sensor, and a design was proposed and initially tested to validate direction as a function of field strength and distance. To summarize, this dissertation explores the first fully distributed magnetic field sensor using DAS based techniques and one of the first multi-material fiber draw processes which can produce consistent single mode fiber up to 1-km. Due to extensive FEA modeling, multiple iterations of the magnetic sensor were fully characterized and an equation describing the relationship between sensor design and strain transfer has been created and validated experimentally. Multi-parameter tests including acoustic and magnetic fields were implemented and an algorithm was developed to separate the mixed signals. Finally, a test was performed to demonstrate the feasibility of sensing magnetic fields directionally. Cumulative results demonstrate a high-quality sensor alternative to current designs which may surpass other magnetic sensors due to innate multi-parameter capabilities, in addition to the inexpensive production cost and extremely long operating lengths.

02 PETROLEUM↗

Ptychographic X-ray speckle tracking with multi-layer Laue lens systems

The ever-increasing brightness of synchrotron radiation sources demands improved X-ray optics to utilize their capability for imaging and probing biological cells, nano-devices and functional matter on the nanometre scale with chemical sensitivity. Hard X-rays are ideal for high-resolution imaging and spectroscopic applications owing to their short wavelength, high penetrating power and chemical sensitivity. The penetrating power that makes X-rays useful for imaging also makes focusing them technologically challenging. Recent developments in layer deposition techniques have enabled the fabrication of a series of highly focusing X-ray lenses, known as wedged multi-layer Laue lenses. Improvements to the lens design and fabrication technique demand an accurate, robust, in situ and at-wavelength characterization method. To this end, a modified form of the speckle tracking wavefront metrology method has been developed. The ptychographic X-ray speckle tracking method is capable of operating with highly divergent wavefields. A useful by-product of this method is that it also provides high-resolution and aberration-free projection images of extended specimens. Three separate experiments using this method are reported, where the ray path angles have been resolved to within 4 nrad with an imaging resolution of 45 nm (full period). This method does not require a high degree of coherence, making it suitable for laboratory-based X-ray sources. Likewise, it is robust to errors in the registered sample positions, making it suitable for X-ray free-electron laser facilities, where beam-pointing fluctuations can be problematic for wavefront metrology.

36 MATERIALS SCIENCE↗

A comparison of Raman and pyrometry dynamic temperature measurements of shocked cyclohexane

Optical pyrometry is a well-developed, broadly applicable method to determine temperature in dynamic compression experiments. However, it measures radiation from only the skin depth of the radiant material, is highly susceptible to spurious backgrounds, and requires an often-unmeasurable free parameter—the sample dynamic emissivity. Raman spectroscopy offers a method to determine temperature directly from fundamental theory, but it is practically limited in applications to a small subset of shock experiments. In this work, we describe an experiment allowing simultaneous application of Raman and pyrometric temperature techniques to benchmark a specific instance of pyrometry. We attempted both measurements on multiple experiments and compare the successful temperature results between the separate but highly repeatable shots. Here, we find that dynamic shock temperatures inferred from Raman spectroscopy and pyrometry generally agree within the uncertainties of each measurement, although those uncertainties are larger than typical for a specially designed pyrometry experiment on a shocked metal sample.

74 ATOMIC AND MOLECULAR PHYSICS↗

Machine Learning–Augmented Laser-Induced Breakdown Spectroscopy for Spectral Discrimination of Iron Oxalates

Enhanced characterization and phase identification of post-PUREX Pu Oxalates (PuOXA) are pivotal for nonproliferation and pre-detonation nuclear forensics. Despite significant advances in the characterization of PuO 2 samples, little is known about the impact of both the chemical structure and oxidation states of PuOXA (i.e., Pu(III) and Pu(IV)) have on optical emission signatures. Here, we demonstrate the analytical capabilities of laser-induced breakdown spectroscopy (LIBS) applied to Fe(II) and Fe(III) oxalate samples as surrogates for PuOXA, highlighting the discriminating features in the LIBS emission spectra arising from differences in the oxidation states within mixed FeOXA samples. We report the enhancement of spectral feature selection using Principal Component Analysis (PCA), which enables the analytical superiority of machine learning algorithms such as Linear Discriminant Analysis (LDA), Quadratic Discriminant Analysis (QDA), Partial Least Squares Regression (PLSR), Support Vector Regression (SVR), and Random Forest Regression (RFR) over conventional univariate techniques for phase discrimination and chemometric analysis. Cluster analysis revealed how both matrix effects and laser ablation influence cluster separability by introducing spectral artifacts that misdirect the maximization of variance. PCA-selected emission lines were used in the regression models, demonstrating that both univariate and multivariate linear regression models (i.e., PLSR and SVR) can achieve acceptable performance, with machine learning models outperforming conventional calibration regressions. Furthermore, the application of non-linearly activated PCA-selected emission lines illustrates how simplifying the data while retaining captured variance enables the use of less complex and more computationally efficient models. Furthermore, this is particularly evident in the underperformance of RFR, which suffers from increased computational costs and overfitting owing to its high complexity.

Oxalates↗

TESS Hunt for Young and Maturing Exoplanets (THYME). V. A Sub-Neptune Transiting a Young Star in a Newly Discovered 250 Myr Association

The detection and characterization of young planetary systems offer a direct path to study the processes that shape planet evolution. We report on the discovery of a sub-Neptune-sized planet orbiting the young star HD 110082 (TOI-1098). Transit events we initially detected during TESS Cycle 1 are validated with time-series photometry from Spitzer. High-contrast imaging and high-resolution, optical spectra are also obtained to characterize the stellar host and confirm the planetary nature of the transits. The host star is a late-F dwarf (M {sub ⋆} = 1.2M {sub ⊙}) with a low-mass, M dwarf binary companion (M {sub ⋆} = 0.26M {sub ⊙}) separated by nearly one arcminute (∼6200 au). Based on its rapid rotation and Lithium absorption, HD 110082 is young, but is not a member of any known group of young stars (despite proximity to the Octans association). To measure the age of the system, we search for coeval, phase-space neighbors and compile a sample of candidate siblings to compare with the empirical sequences of young clusters and to apply quantitative age-dating techniques. In doing so, we find that HD 110082 resides in a new young stellar association we designate MELANGE-1, with an age of 250{sub −70}{sup +50} Myr. Jointly modeling the TESS and Spitzer light curves, we measure a planetary orbital period of 10.1827 days and radius of R {sub p} = 3.2 ± 0.1R {sub ⊕}. HD 110082 b’s radius falls in the largest 12% of field-age systems with similar host-star mass and orbital period. This finding supports previous studies indicating that young planets have larger radii than their field-age counterparts.

47 OTHER INSTRUMENTATION↗

How non-ohmic contact-layer diodes in perovskite pinholes affect abrupt low-voltage reverse-bias breakdown and destruction of solar cells

Perovskite solar cells (PSCs) rapidly degrade under reverse bias, a condition that may occur during partial shading. Here, in this study, we use electrical measurements, electron microscopy, and optical and thermal imaging to investigate abrupt breakdown and hotspotting under low reverse potentials (<|-2| V). We show that microscopic pinholes in the perovskite layer cause rapid, destructive breakdown under reverse bias despite minimally reducing power conversion efficiencies. Measurements on miniature (200-micrometer diameter) PSCs and perovskite-free transport-layer diodes indicate that abrupt, low-voltage breakdown occurs in nanoscale to micrometer-scale defects and that metal migration and filamentation are unlikely causes. Reverse-bias stability substantially improves when pinholes in the perovskite and transport layers are eliminated. Atomic layer deposition of tin oxide prevents abrupt breakdown by ensuring physical separation between electrodes-not by blocking metal ion migration. Perovskite researchers should adopt cleaner, more uniform deposition techniques to enable robust PSCs for further research and commercial applications.

14 SOLAR ENERGY↗

A method for generating quantitative vapor-phase infrared spectra of solids: results for phenol, camphor, menthol, syringol, dicyclopentadiene and naphthalene

Here, a method is presented to generate quantitative vapor-phase infrared spectra from substances that naturally occur as solids with moderate volatility. The solid is gravimetrically dissolved into a solvent that has few infrared spectral features, typically CS 2 and CCl 4 separately. The solution is flowed at a constant rate from a linearly pumped syringe into a metered stream of nitrogen carrier gas regulated by a mass flow controller. The analyte/solvent mix is flash vaporized by volatilizing the solution across a heated stainless-steel surface as it emanates from the syringe tip. The N 2 gas-solution mixture is flowed into a long-path White cell thermostatted at a desired temperature, the long optical path compensating for the modest analyte mixing ratio. A composite spectrum is generated from typically ten or more 760-Torr pressure-broadened spectra over the 600 to 6500 cm -1 spectral range at 0.1 cm -1 spectral resolution. The solid analytes reported here using this novel technique include dicyclopentadiene, menthol, syringol, phenol, camphor, and naphthalene.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a novel mid-infrared pyrometer for dynamic material experiments

Temperature is a complicated thermodynamic parameter to measure in dynamic compression experiments. Optical pyrometry is a general-purpose “work-horse” technique for measuring temperature from a radiant surface on these experimental platforms. The optical pyrometry channels are commonly held to the visible or Near-Infrared spectrum, which provides high fidelity temperature measurement for shock temperature above ∼1200–1500 K. However, low temperature (T < 1200 K) dynamic material experiments, including low pressure or quasi-isentropic studies, as well as experiments with complex thermodynamic paths, require Mid-Infrared (Mid-IR) for high fidelity measurements. This article outlines the design, testing, and characterization of a novel Mid-IR pyrometer system that can be configured between 2.5 and 5.0 µm, suitable for lower temperature measurements and for increasing the fidelity and precision of higher temperature measurements. Experimental validation was done on two separate gas gun platforms, with two separate impact velocities, achieving temperatures between 450 and 1100 K.

Dutra, E. C. (ORCID:0000000167649195)↗

Solution-Processable Polymer Donor-Small Molecule Acceptor Bulk Heterojunction Organocatalysts for Enhancing CO 2 -to-CO Photoconversion

Metal-free organic semiconductors have emerged as a kind of promising star material in photocatalysis. However, their photocatalytic efficacy is impeded by the great recombination rate of the photogenerated charge carriers. Herein, we demonstrate the devising of solution-processable organic semiconductor bulk heterojunction (BHJ) systems with varying ratios by using BP3DT and PC 61 BM as the donor (D) and acceptor (A) candidates, respectively, for enhanced selective CO production from CO 2 photoreduction. The prepared BP3DT/PC 61 BM BHJs are solution-processed on both glass substrates (GS) and molecular sieves (MS) via a drop-casting technique to form an active thin film and porous photocatalysts to catalyze CO production. All BP3DT/PC 61 BM BHJs efficiently produce CO as the primary product in the existence of trace-level TEA/H 2 O (0.5 mL). Our results show that the photocatalytic efficiency depended on the D/A w% ratios and its nanoscale phase separation morphology within the BHJ, contributing to the promotion of exciton dissociation. Additionally, the BHJ undergoes an ostensible morphological transition from large-scale phase-separation to a fine mixed homogeneous nanoscale by varying the BP3DT/PC 61 BM blend ratio from 30/70 w% to 70/30 w%, which increases the interfacial area and shortens the distance of the exciton to the D/A surface, and promotes charge carrier separation, corroborated by photo-optical and photoelectrochemical experimental results. Accordingly, the resulting BP3DT/PC 61 BM BHJ@MS with a D/A ratio of 70/30 w% achieves a CO yield of 819 μmol·g cat -1 h -1 , surpassing those of pure PC 61 BM (126 μmol·g cat -1 h -1 ) and BP3DT (72 μmol·g cat -1 h -1 ) by 6.5- to 11.3-fold and also exceeding that of metal-free linear conjugated polymer-based organocatalysts reported to date. Specifically, this is the first work to develop an organic-semiconductor-based BHJ photocatalyst, which may offer a nascent way to design more efficient organocatalysts for CO 2 reduction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A non-intrusive optical (NIO) approach to characterize heliostats in utility-scale power tower plants: Methodology and in-situ validation

No reliable in-situ optical characterization tool is available that can efficiently and accurately measure various optical errors of individual heliostats in a utility-scale power-tower plant. Here, an innovative non-intrusive optical (NIO) approach is proposed to measure mirror surface slope error, mirror facet canting error, and heliostat tracking error based on reflection images using the natural target—the tower—in a heliostat field. The NIO approach adopts various techniques in photogrammetry, reflectometry, and geometrical optics to first determine the camera position and the actual tower position with respect to the heliostat. Then, Snell’s law is applied to find the surface normal at the reflection point or line of a reflection image and derive the surface slope error, mirror facet canting error, and heliostat tracking error accordingly. In addition, an in-situ validation is performed to demonstrate the feasibility of the NIO approach. Analysis with multiple sets of reflection images on one single heliostat of interest demonstrates that the NIO method can achieve a measurement uncertainty of 0.22 mrad for mirror facet slope error (root-mean-square) at the given test conditions. The sensitivity of measurement uncertainty to various parameters will be presented in a separate work. In the future, state-of-the-art unmanned aerial systems (UAS) are planned to perform the efficient image collection with a goal to complete the survey across a utility-scale field of over 10,000 heliostats within one or a few days depending on the number of UASs. The development of the NIO approach is expected to fill the critical gap for successful solar-field operation and maintenance, which is necessary for the global growth of the solar power-tower technology. The NIO approach can also be applied to any relevant industry requiring high-precision mirror surface shape characterization.

14 SOLAR ENERGY↗

Real-Time Detection of Hydrogen and Ammonia Isotopologues for Impurity Removal and Recovery of Tritium

To accommodate gas measurements for impurity removal and recovery of tritium, a silver-coated optical or waveguide is employed for collecting Raman scattered signals to determine relative hydrogen and ammonia isotopologue populations in real time. The data and results presented here demonstrate an analytical methodology for the analysis of four ammonia and three hydrogen isotopologues in a hydrogen–deuterium exchange reaction by gas phase Raman spectroscopy. Standard chemometric modeling techniques effectively unravel the signatures of the isotopologues involved observed here; however, a sophisticated quantum chemical approach supports the spectral assignments. An interpretation of the data presented here can emphasize the practicality and reliability of the gaseous monitoring system in complex chemical environments for the hydrogen fuel economy as well as the more distant energy source from a facility that handles tritium. There are still considerable concerns about the measurement of tritium in isotope separation and radiological impurities from gas processing. A common impurity in gas processing is ammonia, which can form readily in the presence of nitrogen and tritium. Substituted ammonia (NQ 3 ), where Q = H, D, or T, is traditionally removed through getters or diffusers along with other non-hydrogen contaminants. A preferable analytical approach is noninvasive and can be deployed for real-time process evaluation in radiological environments.

Ammonia↗

High-throughput micro-scale bandgap mapping for perovskite-inspired materials with complex composition space

Abstract To realize the full promise of high-throughput experimental workflows, the rate of sample synthesis must be matched by that of characterization. Of growing interest are contactless optical techniques that can rapidly measure material homogeneity and properties. Here, we present a hyperspectral imaging method to measure local optical bandgap distributions within samples, utilizing spatially-resolved reflectance spectra coupled with automated data analysis. We collect approximately one million optical bandgap data across the compositional space of Cs 3 (Bi x Sb 1-x ) 2 (Br y I 1-y ) 9 perovskite-inspired materials. Our results show non-monotonic bandgap variations (i.e., bandgap bowing) along six composition gradient sequences, in addition to identifying samples with multiple bandgaps in statistics. High-throughput transient absorption spectroscopy reveals that within these compositions, the depletion of the ground state carriers to excited states occurred at discrete energy levels with independent carrier dynamics, consistent with the bandgap observation and indicative of phase separation. This work demonstrates the potential for rapid optical measurements to assess material quality and homogeneity in a high-throughput experimental setting, supporting screening and recipe optimization of optoelectronic material candidates with desired carrier dynamics and optical properties.

Science & Technology - Other Topics↗

High-speed fiber-based spectrometer for plasma Thomson scattering

Here we present a novel concept for a Thomson scattering diagnostic, based on a high-speed fiber optic spectrometer. The high-speed fiber optic spectrometer presented here translates a spectral measurement from the frequency domain into the time domain, thus requiring the use of only a single photodetector for spectral acquisition. The high temporal precision offered by the instrument gives rise to a number of advantages over traditional spectrometers, such as nearly background-free measurements and multiple uses of the same injected beam. Multiple uses of the same beam would enable greatly increased measurement rates, in the range of 10–100 MHz. The spectral range and resolution of the fiber spectrometer can be easily tailored to be optimized for the light source and experimental conditions by selecting different lengths of fiber, thus allowing for the proposed technique to exhibit high dynamic range when measuring many points simultaneously. Finally, due to the temporal separation of the background from the signal, these improvements are possible without the need for increased average input laser power.

47 OTHER INSTRUMENTATION↗