Search NASA⌕ Search

SEARCH · Search NASA

Results for “organic polymers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Spatially resolved organic analysis of the Allende meteorite

The distribution of polycyclic aromatic hydrocarbons (PAHs) in the Allende meteorite has been probed with two-step laser desorption/laser multiphoton ionization mass spectrometry. This method allows direct in situ analysis with a spatial resolution of 1 sq mm or better of selected organic molecules. Spectra from freshly fractured interior surfaces of the meteorite show that PAH concentrations are locally high compared to the average concentrations found by wet chemical analysis of pulverized samples. The data suggest that the PAHs are primarily associated with the fine-grained matrix, where the organic polymer occurs. In addition, highly substituted PAH skeletons were observed. Interiors of individual chondrules were devoid of PAHs at the detection limit (about 0.05 ppm).

Zenobi, Renato↗

Huygens/ACP: An instrument for aerosols chemical composition measurements

The Aerosol Collector Pyrolyzer (ACP) which will be used aboard the Huygens probe is introduced. The scientific objectives, scientific rationale, and a technical description of the ACP are given. The ACP will sample the aerosols of the Titan's atmosphere in two regions, 160 to 60 and 60 to 25 km, respectively. In the first region, it will collect aerosol particles absorbed by a complex core (organic polymers) coated with absorbed or condensed molecules. The second collect will sample larger aerosols and the N2-CH4 droplets. In each sampling, the particles are collected on a metallic filter through which the atmospheric gas is pumped. The filter is then inserted into an oven connected to the Gas Chromatograph Mass Spectrometer (GCMS) Experiment which analyzes the gases produced during the heating of the samples. For each sample it will be possible to bring information on the nature and abundance of the volatile components contained in the particles and/or the composition of the photochemical core.

Israel, Guy↗

Issues/considerations and performance prediction of LEO protective coatings

Organic materials can be used in low earth orbit for long periods only if they are made to be durable to atomic oxygen in addition to the threats of ultraviolet radiation, micrometeoroid and debris impact, thermal cycling, and charged particle radiation. In many materials applications, it is more cost-effective to utilize atomic oxygen protective coatings over materials which are vulnerable to attack by atomic oxygen rather than developing alternative materials which are inherently durable. Many metal and metal oxide coatings have been shown to be potentially suitable for long term protection of organic polymers in low earth orbit. The protection afforded by thin film coatings on polymeric substrates is highly dependent on the completeness of coverage of the coating. Thus, the prime indicator of durability is the size and abundance of pin windows and scratches in the protective coating. Such defects depend on the deposition technique, smoothness of the surface to be protected, and presence of particulate contaminants. Issues and considerations relevant to substrate preparation, deposition of protective coatings, ground laboratory simulation and evaluation of threats in low earth orbit to protective materials, results of in-space tests, and the use of Monte Carlo modeling techniques to predict in-space durability are presented in graphic form.

Banks, Bruce A.↗

Atomic oxygen interaction with spacecraft materials: Relationship between orbital and ground-based testing for materials certification

The effects of atomic oxygen on boron nitride (BN), silicon nitride (Si3N4), Intelsat 6 solar cell interconnects, organic polymers, and MoS2 and WS2 dry lubricant, were studied in Low Earth Orbit (LEO) flight experiments and in a ground based simulation facility. Both the inflight and ground based experiments employed in situ electrical resistance measurements to detect penetration of atomic oxygen through materials and Electron Spectroscopy for Chemical Analysis (ESCA) analysis to measure chemical composition changes. Results are given. The ground based results on the materials studied to date show good qualitative correlation with the LEO flight results, thus validating the simulation fidelity of the ground based facility in terms of reproducing LEO flight results. In addition it was demonstrated that ground based simulation is capable of performing more detailed experiments than orbital exposures can presently perform. This allows the development of a fundamental understanding of the mechanisms involved in the LEO environment degradation of materials.

Cross, Jon B.↗

Method of making a membrane having hydrophilic and hydrophobic surfaces for adhering cells or antibodies by using atomic oxygen or hydroxyl radicals

A portion of an organic polymer article such as a membrane is made hydrophilic by exposing a hydrophobic surface of the article to a depth of about 50 to about 5000 angstroms to atomic oxygen or hydroxyl radicals at a temperature below 100C., preferably below 40 C, to form a hydrophilic uniform surface layer of hydrophilic hydroxyl groups. The atomic oxygen and hydroxyl radicals are generated by a flowing afterglow microwave discharge, and the surface is outside of a plasma produced by the discharge. A membrane having both hydrophilic and hydrophobic surfaces can be used in an immunoassay by adhering antibodies to the hydrophobic surface. In another embodiment, the membrane is used in cell culturing where cells adhere to the hydrophilic surface. Prior to adhering cells, the hydrophilic surface may be grafted with a compatibilizing compound. A plurality of hydrophilic regions bounded by adjacent hydrophobic regions can be produced such that a maximum of one cell per each hydrophilic region adheres.

Koontz, Steven L.↗

Gravitational Effects on the Morphology and Kinetics of Photodeposition of Polydiacetylene Thin Films From Monomer Solutions

The goal of this proposed work is to study gravitational effects on the photodeposition of polydiacetylene thin films from monomer solutions onto transparent substrates. Polydiacetylenes have been an extensively studied class of organic polymers because they exhibit many unusual and interesting properties, including electrical conductivity and optical nonlinearity. Their long polymeric chains render polydiacetylenes readily conducive to thin film formation, which is necessary for many applications. These applications require thin polydiacetylene films possessing uniform thicknesses, high purity, minimal inhomogeneities and defects (such as scattering centers), etc. Also, understanding and controlling the microstructure and morphology of the films is important for optimizing their electronic and optical properties. The lack of techniques for processing polydiacetylenes into such films has been the primary limitation to their commercial use. We have recently discovered a novel method for the formation of polydiacetylene thin films using photo-deposition from monomer solutions onto transparent substrates with UV light. This technique is very simple to carry out, and can yield films with superior quality to those produced by conventional methods. Furthermore, these films exhibit good third-order properties and are capable of waveguiding. We have been actively studying the chemistry of diacetylene polymerization in solution and the photo-deposition of polydiacetylene thin films from solution. It is well-known that gravitational factors such as buoyancy-driven convection and sedimentation can affect chemical and mass transport processes in solution. One important aspect of polydiacetylene thin film photodeposition in solution, relevant to microgravity science, is that heat generated by absorption of UV radiation induces thermal density gradients that under the influence of gravity, can cause fluid flows (buoyancy-driven convection). Additionally, changes in the chemical composition of the solution during polymerization may cause solutal convection. These fluid flows affect transport of material to and from the film surface and thereby affect the kinetics of the growth process. This manifests itself in the morphology of the resulting films; films grown under the influence of convection tend to have less uniform thicknesses, and can possess greater inhomogeneities and defects. Specifically, polydiacetylene films photodeposited from solution, when viewed under a microscope, exhibit very small particles of solid polymer which get transported by convection from the bulk solution to the surface of the growing film and become embedded. Even when carried out under conditions designed to minimize unstable density gradients (i.e., irradiating the solution from the top), some fluid flow still takes place (particles remain present in the films). It is also possible that defect nucleation may be occurring within the films or on the surface of the substrate; this, too, can be affected by convection (as is the case with crystal growth). Hence films grown in 1-g will, at best, still possess some defects. The objective of this proposal is to investigate, both in 1-g and in low-g, the effects of gravitational factors (primarily convection) on the dynamics of these processes, and on the quality, morphology, and properties of the films obtained.

Paley, Mark S.↗

Overview of Photonic Materials for Application in Space Environments

Future space systems will he based on components evolving from the development and refinement of new and existing photonic materials. Optically based sensors, inertial guidance, tracking systems, communications, diagnostics, imaging and high speed optical processing are but a few of the applications expected to widely utilize photonic materials. The response of these materials to space environment effects (SEE) such as spacecraft charging, orbital debris, atomic oxygen, ultraviolet irradiation, temperature and ionizing radiation will be paramount to ensuring successful space applications. The intent of this paper is to, address the latter two environments via a succinct comparison of the known sensitivities of selected photonic materials to the temperature and ionizing radiation conditions found in space and enhanced space environments Delineation of the known temperature and radiation induced responses in LiNbO3, AlGaN, AlGsAs,TeO2, Si:Ge, and several organic polymers are presented. Photonic materials are realizing rapid transition into applications for many proposed space components and systems including: optical interconnects, optical gyros, waveguide and spatial light modulators, light emitting diodes, lasers, optical fibers and fiber optic amplifiers. Changes to material parameters such as electrooptic coefficients, absorption coefficients, polarization, conductivity, coupling coefficients, diffraction efficiencies, and other pertinent material properties examined for thermo-optic and radiation induced effect. Conclusions and recommendations provide the reader with an understanding of the limitations or attributes of material choices for specific applications.

Taylor, E. W.↗

Protective Coatings

Ameron International Protective Coatings Group developed a special coating for NASA that would withstand the high temperatures generated by the Space Shuttle rocket engines. The coating remains intact for at least 10 minutes, and insulates the launch pad so that it does not exceed 150 degrees and buckle. The NASA formulation was from Ameron's Engineered Siloxane (PSX) chemistry, which employs an inorganic silicon-oxygen structure which the company states is stronger and more reliable than organic polymers. Some of Ameron's PSX product line is based on the NASA technology, used for everything from industrial equipment to bridges.

Source record↗

Thin-film Organic-based Solar Cells for Space Power

Recent advances in dye-sensitized and organic polymer solar cells have lead NASA to investigate the potential of these devices for space power generation. Dye-sensitized solar cells were exposed to simulated low-earth orbit conditions and their performance evaluated. All cells were characterized under simulated air mass zero (AM0) illumination. Complete cells were exposed to pressures less than 1 x 10(exp -7) torr for over a month, with no sign of sealant failure or electrolyte leakage. Cells from Solaronix SA were rapid thermal cycled under simulated low-earth orbit conditions. The cells were cycled 100 times from -80 C to 80 C, which is equivalent to 6 days in orbit. The best cell had a 4.6 percent loss in efficiency as a result of the thermal cycling. In a separate project, novel -Bridge-Donor-Bridge- Acceptor- (-BDBA-) type conjugated block copolymer systems have been synthesized and characterized by photoluminescence (PL). In comparison to pristine donor or acceptor, the PL emissions of final -B-D-B-A- block copolymer films were quenched over 99 percent. Effective and efficient photo induced electron transfer and charge separation occurs due to the interfaces of micro phase separated donor and acceptor blocks. The system is very promising for a variety high efficiency light harvesting applications. Under an SBIR contract, fullerene-doped polymer-based photovoltaic devices were fabricated and characterized. The best devices showed overall power efficiencies of approx. 0.14 percent under white light. Devices fabricated from 2 percent solids content solutions in chlorobenzene gave the best results. Presently, device lifetimes are too short to be practical for space applications.

Bailey, Sheila G.↗

DMA Modulus as a Screening Parameter for Compatibility of Polymeric Containment Materials with Various Solutions for use in Space Shuttle Microgravity Protein Crystal Growth (PCG) Experiments

Protein crystals are grown in microgravity experiments inside the Space Shuttle during orbit. Such crystals are basically grown in a five-component system containing a salt, buffer, polymer, organic and water. During these experiments, a number of different polymeric containment materials must be compatible with up to hundreds of different PCG solutions in various concentrations for durations up to 180 days. When such compatibility experiments are performed at NASA/MSFC (Marshall Space Flight Center) simultaneously on containment material samples immersed in various solutions in vials, the samples are rather small out of necessity. DMA4 modulus was often used as the primary screening parameter for such small samples as a pass/fail criterion for incompatibility issues. In particular, the TA Instruments DMA 2980 film tension clamp was used to test rubber O-rings as small in I.D. as 0.091 in. by cutting through the cross-section at one place, then clamping the stretched linear cord stock at each end. The film tension clamp was also used to successfully test short length samples of medical/surgical grade tubing with an O.D. of 0.125 in.

Wingard, Charles Doug↗

Thin-Film Organic-Based Solar Cells for Space Power

Recent advances in dye-sensitized and organic polymer solar cells have lead NASA to investigate the potential of these devices for space power generation. Dye-sensitaized solar cells were exposed to simulated low-earth orbit conditions and their performance evaluated. All cells were characterized under simulated air mass zero (AM0) illumination. Complete cells were exposed to pressures less than 1 x 10 (exp -7)torr for over a month, with no sign of sealant failure or electrolyte leakage. Cells from Solaronix SA were rapid thermal cycled under simulated low-earth orbit conditions. The cells were cycled 100 times from -80 C to 80 C, which is equivalent to 6 days in orbit. The best cell had a 4.6% loss in efficiency as a result of the thermal cycling. In a separate project, novel -Bridge-Donor-Bridge-Acceptor- (-BDBA-) type conjugated block copolymer systems have been synthesized and characterized by photoluminescence (PL). In comparison to pristine donor or acceptor, the PL emissions of final -B-D-B-A- block copolymer films were quenched over 99%. Effective and efficient photo induced electron transfer and charge separation occurs due to the interfaces of micro phase separated donor and acceptor blocks. The system is very promising for a variety high efficiency light harvesting applications. Under an SBIR contract, fullerene-doped polymer-based photovoltaic devices were fabricated and characterized. The best devices showed overall power efficiencies of approximately 0.14% under white light. Devices fabricated from 2% solids content solutions in chlorobenzene gave the best results. Presently, device lifetimes are too short to be practical for space applications.

Bailey, Sheila G.↗

Porous cobalt spheres for high temperature gradient magnetically assisted fluidized beds

Porous metallic cobalt spheres have been prepared as high temperature capable media for employment in gradient magnetically assisted fluidization and filtration technologies. Cobalt impregnated alginate beads are first formed by extrusion of an aqueous suspension of Co3O4 into a Co(II) chloride solution. The organic polymer is thermally decomposed yielding cobalt oxide spheres, followed by reduction to the metallic state, and densification. Cobalt beads have been produced with porosities ranging between 10 and 50%, depending upon sintering conditions. The product media have been characterized by scanning electron microscopy (SEM), nitrogen adsorption porosimetry, and vibrating sample magnetometry. c2003 Elsevier Science Ltd. All rights reserved.

NASA Discipline Life Support Systems↗

Determination of Ground-Laboratory to In-Space Effective Atomic Oxygen Fluence for DC 93?500 Silicone

The objective of this research was to calibrate the ground-to-space effective atomic oxygen fluence for DC 93-500 silicone in a thermal energy electron cyclotron resonance (ECR) oxygen plasma facility. Silicones, commonly used spacecraft materials, do not chemically erode with atomic oxygen attack like other organic materials but form an oxidized hardened silicate surface layer. Therefore, the effective atomic oxygen fluence in a ground test facility should not be determined based on mass loss measurements, as they are with organic polymers. A technique has been developed at the Glenn Research Center to determine the equivalent amount of atomic oxygen exposure in an ECR ground test facility to produce the same degree of atomic oxygen damage as in space. The approach used was to compare changes in the surface hardness of ground test (ECR) exposed DC 93-500 silicone with DC 93-500 exposed to low Earth orbit (LEO) atomic oxygen as part of a shuttle flight experiment. The ground to in-space effective atomic oxygen fluence correlation was determined based on the fluence in the ECR source that produced the same hardness for the fluence in-space. Nanomechanical hardness versus contact depth measurements were obtained for five ECR exposed DC 93-500 samples (ECR exposed for 18 to 40 hrs, corresponding to Kapton effective fluences of 4.2 x 10(exp 20) to 9.4 x 10(exp 20) atoms/sq cm, respectively) and for space exposed DC 93-500 from the Evaluation of Oxygen Interactions with Materials III (EOIM III) shuttle flight experiment, exposed to LEO atomic oxygen for 2.3 x 10(exp 20) atoms/sq cm. Pristine controls were also evaluated. A ground-to-space correlation value was determined based on correlation values for four contact depths (150, 200, 250, and 300 nm), which represent the near surface depth data. The results indicate that the Kapton effective atomic oxygen fluence in the ECR facility needs to be 2.64 times higher than in LEO to replicate equivalent exposure damage in the ground test silicone as occurred in the space exposed silicone.

deGroh, Kim K.↗

Competitive Oxidation and Hydration During Aqueous Alteration of Asteroids

Introduction: Studies of chondrites show that incorporation of H2O ice during formation of asteroids followed by radioactive heating caused partial oxidation and hydration of primary reduced and anhydrous rocks. Oxidation of kamacite, phosphides, troilite and organic polymers occurred through consumption of water s oxygen and release of H2. Hydration caused formation of serpentine, saponite, chlorite, talc and hydrated salts. Since H2O was the major reactant in oxidation and hydration, these processes could have been competitive. Redox reactions in asteroids should have been closely connected to hydration (dehydration) during aqueous alteration and thermal metamorphism. For example, dehydration and reduction release H2O that can be consumed in oxidation and hydration, respectively. We model asteroidal processes in order to quantify the fate of H2O and water s oxygen in major redox and hydration/dehydration reactions. Model: Equilibrium compositions in the gas-solid-liquid

Zolotov, M. Y.↗

Sensors for detecting analytes in fluids

Chemical sensors for detecting analytes in fluids comprise first and second conductive elements (e.g., electrical leads) electrically coupled to and separated by a chemically sensitive resistor which provides an electrical path between the conductive elements. The resistor comprises a plurality of alternating nonconductive regions (comprising a nonconductive organic polymer) and conductive regions (comprising a conductive material) transverse to the electrical path. The resistor provides a difference in resistance between the conductive elements when contacted with a fluid comprising a chemical analyte at a first concentration, than when contacted with a fluid comprising the chemical analyte at a second different concentration. Arrays of such sensors are constructed with at least two sensors having different chemically sensitive resistors providing dissimilar such differences in resistance. Variability in chemical sensitivity from sensor to sensor is provided by qualitatively or quantitatively varying the composition of the conductive and/or nonconductive regions. An electronic nose for detecting an analyte in a fluid may be constructed by using such arrays in conjunction with an electrical measuring device electrically connected to the conductive elements of each sensor.

Lewis, Nathan S.↗

Sensors for detecting analytes in fluids

Chemical sensors for detecting analytes in fluids comprise first and second conductive elements (e.g., electrical leads) electrically coupled to and separated by a chemically sensitive resistor which provides an electrical path between the conductive elements. The resistor comprises a plurality of alternating nonconductive regions (comprising a nonconductive organic polymer) and conductive regions (comprising a conductive material) transverse to the electrical path. The resistor provides a difference in resistance between the conductive elements when contacted with a fluid comprising a chemical analyte at a first concentration, than when contacted with a fluid comprising the chemical analyte at a second different concentration. Arrays of such sensors are constructed with at least two sensors having different chemically sensitive resistors providing dissimilar such differences in resistance. Variability in chemical sensitivity from sensor to sensor is provided by qualitatively or quantitatively varying the composition of the conductive and/or nonconductive regions. An electronic nose for detecting an analyte in a fluid may be constructed by using such arrays in conjunction with an electrical measuring device electrically connected to the conductive elements of each sensor.

Lewis, Nathan S.↗

Sensors for detecting analytes in fluids

Chemical sensors for detecting analytes in fluids comprise first and second conductive elements (e.g., electrical leads) electrically coupled to and separated by a chemically sensitive resistor which provides an electrical path between the conductive elements. The resistor comprises a plurality of alternating nonconductive regions (comprising a nonconductive organic polymer) and conductive regions (comprising a conductive material) transverse to the electrical path. The resistor provides a difference in resistance between the conductive elements when contacted with a fluid comprising a chemical analyte at a first concentration, than when contacted with a fluid comprising the chemical analyte at a second different concentration. Arrays of such sensors are constructed with at least two sensors having different chemically sensitive resistors providing dissimilar such differences in resistance. Variability in chemical sensitivity from sensor to sensor is provided by qualitatively or quantitatively varying the composition of the conductive and/or nonconductive regions. An electronic nose for detecting an analyte in a fluid may be constructed by using such arrays in conjunction with an electrical measuring device electrically connected to the conductive elements of each sensor.

Lewis, Nathan S.↗

Sensor arrays for detecting analytes in fluids

Chemical sensors for detecting analytes in fluids comprise first and second conductive elements (e.g. electrical leads) electrically coupled to and separated by a chemically sensitive resistor which provides an electrical path between the conductive elements. The resistor comprises a plurality of alternating nonconductive regions (comprising a nonconductive organic polymer) and conductive regions (comprising a conductive material) transverse to the electrical path. The resistor provides a difference in resistance between the conductive elements when contacted with a fluid comprising a chemical analyte at a first concentration, than when contacted with a fluid comprising the chemical analyte at a second different concentration. Arrays of such sensors are constructed with at least two sensors having different chemically sensitive resistors providing dissimilar such differences in resistance. Variability in chemical sensitivity from sensor to sensor is provided by qualitatively or quantitatively varying the composition of the conductive and/or nonconductive regions. An electronic nose for detecting an analyte in a fluid may be constructed by using such arrays in conjunction with an electrical measuring device electrically connected to the conductive elements of each sensor.

Lewis, Nathan S.↗