Search NASA⌕ Search

SEARCH · Search NASA

Results for “oscilloscopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Automated analysis of video data

A software/hardware system designed and developed to perform automated video imagery analysis is described. Major elements included in the analysis system are: (1) sampling oscilloscope; (2) programmable trigger unit; (3) central computer; and (4) software processing library. The function of the scope and trigger unit, in conjunction with the control computer, is to digitize the selected portion of the video image and store as amplitude and time data in computer memory. Evaluation of the video data, analogus to interpretation of a visual image, is accomplished by the processing software. It is indicated that this technique of video image analysis is applicable to a wide variety of nonaerospace applications involving video data and image analysis.

Hafner, D. J.↗

Development of an airborne laser bathymeter

An airborne laser depth sounding system was built and taken through a complete series of field tests. Two green laser sources were tried: a pulsed neon laser at 540 nm and a frequency-doubled Nd:YAG transmitter at 532 nm. To obtain a depth resolution of better than 20 cm, the pulses had a duration of 5 to 7 nanoseconds and could be fired up to at rates of 50 pulses per second. In the receiver, the signal was detected by a photomultiplier tube connected to a 28 cm diameter Cassegrainian telescope that was aimed vertically downward. Oscilloscopic traces of the signal reflected from the sea surface and the ocean floor could either be recorded by a movie camera on 35 mm film or digitized into 500 discrete channels of information and stored on magnetic tape, from which depth information could be extracted. An aerial color movie camera recorded the geographic footprint while a boat crew of oceanographers measured depth and other relevant water parameters. About two hundred hours of flight time on the NASA C-54 airplane in the area of Chincoteague, Virginia, the Chesapeake Bay, and in Key West, Florida, have yielded information on the actual operating conditions of such a system and helped to optimize the design. One can predict the maximum depth attainable in a mission by measuring the effective attenuation coefficient in flight. This quantity is four times smaller than the usual narrow beam attenuation coefficient. Several square miles of a varied underwater landscape were also mapped.

Kim, H., H.↗

Engineering studies of vectorcardiographs in blood pressure measuring systems, appendix 1

A small, portable, relatively inexpensive computer system was developed for on-line use in clinical or laboratory situations. The system features an integrated hardware-software package that permits use of all peripherals, such as analog-to-digital converter, oscilloscope, plotter, digital bus, with an interpreter constructed around the BASIC programming language. The system is conceptually similar to the LINC system developed in 1962, but is more compact and powerful due to intervening advances in integrated circuit technology. A description of the hardware of the system was given. A reference manual, user manual, and programming guides were also presented. Finally, a stereo display system for vectorcardiograms was described.

Mark, R. G.↗

Animal exposure during burn tests

An animal exposure test system has been designed and fabricated for the purpose of collecting physiological and environmental (temperature) data from animal subjects exposed to combustion gases in large scale fire tests. The AETS consists of an open wire mesh, two-compartment cage, one containing an exercise wheel for small rodents, and the other containing one rat instrumented externally for electrocardiogram and respiration. The ECG and respiration sensors are located in a belt placed around the torso of the subject, electrode wires forming an umbilical to a connector in the top of the compartment. A cable extends from the connector to the power supply and signal conditioning electronics. These are connected to a dual-beam oscilloscope for real time monitoring and a magnetic tape recorder having three or more channels. Endpoints observed are bradycardia, cardiac arrhythmias, changes in respiratory pattern, respiratory arrest and cardiac arrest. The ECG record also appears to be a good method of monitoring animal activity as indicated by an increase in EMG noise superimposed on the record during increased activity of the torso musculature. Examples of the recordings are presented and discussed as to their significance regarding toxicity of fire gases.

Gaume, J. G.↗

Research investigation of the physical interactions and phenomena associated with hypervelocity sub-micron particles

Signals from impact ionization plasmas were studied as a means of performing microparticle composition analysis. Impact ionization signal response was measured in a time-of-flight (TOF) system for lanthanum hexaboride, carbonyl iron, and aluminum microparticle impacts on a tantalum target, primarily in the 1 - 8 km/s velocity range. Oscilloscope photographs of representative ion TOF signal response are given for each material studied. Graphs and histograms are presented of the total charge collected as well as the charge collected in each observed ion mass group. Data show that ion signals consist primarily of the lower ionization potential elements over the 1 - 8 km/s range.

Roy, N. L.↗

The effect of attention loading on the inhibition of choice reaction time to visual motion by concurrent rotary motion

This study investigates the influence of attention loading on the established intersensory effects of passive bodily rotation on choice reaction time (RT) to visual motion. Subjects sat at the center of rotation in an enclosed rotating chamber and observed an oscilloscope on which were, in the center, a tracking display and, 10 deg left of center, a RT line. Three tracking tasks and a no-tracking control condition were presented to all subjects in combination with the RT task, which occurred with and without concurrent cab rotations. Choice RT to line motions was inhibited (probability less than .001) both when there was simultaneous vestibular stimulation and when there was a tracking task; response latencies lengthened progressively with increased similarity between the RT and tracking tasks. However, the attention conditions did not affect the intersensory effect; the significance of this for the nature of the sensory interaction is discussed.

Looper, M.↗

The Lewis Research Center geomagnetic substorm simulation facility

A simulation facility was established at the NASA-Lewis Research Center to determine the response of typical spacecraft materials to the geomagnetic substorm environment and to evaluate instrumentation that will be used to monitor spacecraft system response to this environment. Space environment conditions simulated included the thermal-vacuum conditions of space, solar simulation, geomagnetic substorm electron fluxes and energies, and the low energy plasma environment. Measurements for spacecraft material tests included sample currents, sample surface potentials, and the cumulative number of discharges. Discharge transients were measured by means of current probes and oscilloscopes and were verified by a photomultiplier.

Berkopec, F. D.↗

Reclaiming hybrid integrated circuits

Reclamation method consists of opening very small hole in package and shaking out trapped particles. Procedure is performed in dry box through which an inert gas is flowing to insure no room air enters package. Acoustic transducer monitors sound of vibrating particles. Amplifier produces audio and oscilloscope output. Hole is sealed with heated solder form.

Ebel, G.↗

The Lewis Research Center geomagnetic substorm simulation facility

A simulation facility was established to determine the response of typical spacecraft materials to the geomagnetic substorm environment and to evaluate instrumentation that will be used to monitor spacecraft system response to this environment. Space environment conditions simulated include the thermal-vacuum conditions of space, solar simulation, geomagnetic substorm electron fluxes and energies, and the low energy plasma environment. Measurements for spacecraft material tests include sample currents, sample surface potentials, and the cumulative number of discharges. Discharge transients are measured by means of current probes and oscilloscopes and are verified by a photomultiplier. Details of this facility and typical operating procedures are presented.

Berkopec, F. D.↗

Instrument to average 100 data sets

An instrumentation system is currently under development which will measure many of the important parameters associated with the operation of an internal combustion engine. Some of these parameters include mass-fraction burn rate, ignition energy, and the indicated mean effective pressure. One of the characteristics of an internal combustion engine is the cycle-to-cycle variation of these parameters. A curve-averaging instrument has been produced which will generate the average curve, over 100 cycles, of any engine parameter. the average curve is described by 2048 discrete points which are displayed on an oscilloscope screen to facilitate recording and is available in real time. Input can be any parameter which is expressed as a + or - 10-volt signal. Operation of the curve-averaging instrument is defined between 100 and 6000 rpm. Provisions have also been made for averaging as many as four parameters simultaneously, with a subsequent decrease in resolution. This provides the means to correlate and perhaps interrelate the phenomena occurring in an internal combustion engine. This instrument has been used successfully on a 1975 Chevrolet V8 engine, and on a Continental 6-cylinder aircraft engine. While this instrument was designed for use on an internal combustion engine, with some modification it can be used to average any cyclically varying waveform.

Tuma, G. B.↗

A system for measuring the pulse height distribution of ultrafast photomultipliers

A system for measuring the pulse height distribution of gigahertz bandwidth photomultipliers was developed. This system uses a sampling oscilloscope as a sample-hold circuit and has a bandwidth of 12 gigahertz. Test results are given for a static crossed-filed photomultiplier tested with a demonstration system. Calculations on system amplitude resolution capabilities are included for currently available system components.

Abshire, J. B.↗

Particle parameter analyzing system

An X-Y plotter circuit apparatus is described which displays an input pulse representing particle parameter information, that would ordinarily appear on the screen of an oscilloscope as a rectangular pulse, as a single dot positioned on the screen where the upper right hand corner of the input pulse would have appeared. If another event occurs, and it is desired to display this event, the apparatus is provided to replace the dot with a short horizontal line.

Hansen, D. O.↗

Foil bearings for axial and radial support of high speed rotors: Design, development, and determination of operating characteristics

Flexible surface thrust and journal foil bearings were fabricated, and their performance was demonstrated, both individually and jointly as a unified rotor support system. Experimental results are documented with graphs and oscilloscopic data of trajectories, waveforms, and scans of amplitude response. At speeds of 40,000 to 45,000 rpm and a mean clearance of the order of 15 to 20 micrometers (600 to 800 micrometers, the resilient, air lubricated, spiral groove thrust bearings support a load of 127 N (29 lb; 13 kgf), equivalent to 3.0 N/sq cm (4.5 lb/sq in 0.31 kgf sq cm). Journal bearings with polygonal sections provided stable and highly damped supports at speeds up to 50,000 rpm.

Licht, L.↗

Microcomputerized electric field meter diagnostic and calibration system

A computerized field meter calibration system which includes an apparatus for testing the calibration of field meters normally utilized for measuring electromagnetic field potentials is described. A reference voltage is applied to the field meter for causing signals to be produced on the output terminals thereof. A bank of relays is provided for selectively connecting output terminals of the field meter to a multiplexer by means of a digital voltmeter and an oscilloscope. A frequency-shift-keyed receiver is also connected to one of the terminals of the field meter for transmitting and converting a frequency shift keyed signal to a digital signal which is, subsequently, applied to the multiplexer.

Holley, L. D.↗

Comparison of two different raindrop disdrometers

Different types of impact sensors, used for the measurement of drop size distribution, are described and compared. All of them generate an electrical output which is to a first order a function of the velocity and mass of impacting drops within the size range of 0.25 to 5.0 mm. The disdrometers discussed include an active styrofoam disdrometer, a passive plexiglass sensor, and a cast epoxy disdrometer sensor. The sensors are calibrated by dropping water drops of known size on the sensor, and using an oscilloscope to measure peak amplitude. Similar response characteristics are observed for the active styrofoam disdrometer and the passive plexiglass and brass sensors. The cast epoxy impact sensor is noted to have a faster response and to be more sturdy than the styrofoam or plexiglass sensors.

Rowland, J. R.↗

Measurement of the time-temperature dependent dynamic mechanical properties of boron/aluminum composites

A relatively simple flexural vibration test is developed for accurate measurement of the low-strain dynamic modulus and damping capacity of B/Al composite bar specimens from -200 C to over 500 C. The specimens are prepared from 8-ply unidirectional panels containing 50 volume percent fibers composed of 203-micron commercial boron-on-tungsten fibers. The basic test technique consists of the forced flexural vibration of the composite bar specimens at their two lowest free-free symmetrical resonant modes in a high-vacuum cryostat furnace. Specimen damping is determined from oscilloscope photographs of the free decay obtained after simultaneously removing the resonant drive signal and grounding the vibration-drive electrode. The availability of time-temperature dynamic data coupled with the predictive accuracy of composite theory suggests a future potential for using such data in examining environmental effects on composite macrostructure and microstructure.

Dicarlo, J. A.↗

Low-common-mode differential amplifier

Outputs of differential amplifier are excellently matched in phase and amplitude over wide range of frequencies. Common mode feedback loop offsets differences between two signal paths. Possible applications of circuit are in oscilloscopes, integrated circuit logic tester, and other self contained instruments.

Morrison, S.↗

Rapid testing of pulse transformers

Quality-control testing of pulse transformers is speeded up by method for determining rise time and droop. Instead of using oscilloscope and square-wave generator to measure these characteristics directly, method uses voltmeter and sine-wave generator to measure them indirectly in about one-tenth time. Droop and rise time are determined by measuring input/output voltage ratio at just four frequencies.

Grillo, J.↗