Search NASA⌕ Search

SEARCH · Search NASA

Results for “overcharging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Nickel-cadmium cells for the spacecraft battery

The storage battery for the Telstar satellite must undergo frequent charge-discharge cycles; in addition, it is subject to overcharge during a substantial portion of its life. Nickel-cadmium cells were chosen as best capable of satisfactory long-time operation under these conditions. A design and selection program was undertaken to ensure that Ni-Cd cores would meet objectives imposed by battery service conditions, and the cell enclosure was designed to minimize electrolyte leakage. Selection, qualification, and life tests indicated that a storage battery using the cell design would perform satisfactorily. To date, the only failures occurring during continuing life tests have been among cells subjected to 100 per cent discharge daily; this operation is far in excess of the expected duty cycle of satellite cells.

TELSTAR SATELLITE↗

Hermetically sealed cells protected from internal gas pressure

Manufacturing process prevents damage to hermetically sealed nickel-cadmium secondary cells by buildup of gas pressure during overcharging and reversed charging conditions. The cells are manufactured with less charge capacity in the positive electrode than in the negative electrode, and two additional electrodes are added.

Carson, W. N.↗

Evaluation program for secondary spacecraft cells: Acceptance tests of Eagle-Picher 12.0 ampere-hour nickel-cadmium cells with auxiliary electrodes

An acceptance test program was conducted on 24 cells to insure that all cells put into the life cycle program were of high quality by the removal of cells found to have electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open circuit voltage above 1.150 volts after the cell short test. The cells were rated at 12.0 ampere-hours and equipped with auxiliary electrodes. Test results were: (1) The capacity of the 24 cells ranged from 14.6 to 16.8 ah. All the cells exceeded the rated capacity on all three capacity checks. (2) One cell failed to recover to 1.150 volts after the cell short test. (3) During the overcharge tests, all cells but one failed the test at the c/10 rate after the first minute. (4) A special resistance test was conducted on the auxiliary electrodes of these cells to establish the resistance value necessary which would provide maximum signal power across the auxiliary electrode. The resistance value established was 10 ohms. (5) No electrolyte leakage was observed.

Christy, D. E.↗

Development of uniform and predictable battery materials for nickel-cadmium aerospace cells

Battery materials and manufacturing methods were analyzed with the aim of developing uniform and predictable battery plates for nickel cadmium aerospace cells. A study is presented for the high temperature electrochemical impregnation process for the preparation of nickel cadmium battery plates. This comparative study is set up as a factorially designed experiment to examine both manufacturing and operational variables and any interaction that might exist between them. The manufacturing variables in the factorial design include plaque preparative method, plaque porosity and thickness, impregnation method, and loading, The operational variables are type of duty cycle, charge and discharge rate, extent of overcharge, and depth of discharge.

Source record↗

Evaluation program for secondary spacecraft cells: Acceptance test of Eagle-Picher 100 ampere-hour nickel-cadmium cells with auxiliary electrodes

Tests were conducted on a group of 29 cells for the purpose of removing from the life cycle program all cells found to have electrolyte leakage, internal shorts, low capacity, or inability to recover open circuit voltage above 1.150 volts after the cell short test. The test findings include the following: (1) All the cells exceeded the rated capacity of 103.5 to 119.0 ampere-hours on all three capacity checks. (2) All cells recovered above the 1.150 volt requirement after the cell short test. (3) The cells cannot be overcharged at the c/10 rate without exceeding 1.500 volts after approximately 12 to 13 hours of charge. (4) The resistance value necessary to provide maximum signal power across the auxiliary electrode was found to be 10 ohms. (5) One cell revealed a definite leak at the negative terminal.

Christy, D. E.↗

Evaluation program for secondary spacecraft cells: Acceptance tests of Eagle-Picher 20.0 ampere-hour nickel-cadmium cells with auxiliary electrodes

A group of 29 cells with capacities ranging from 21.7 to 28.8 ampere-hours were tested. A summary of the results indicates: (1) All cells exceeded the rated capacity on all three capacity checks. (2) Five cells failed to recover to 1.150 volts. (3) During the overcharge tests, 15 of the 29 cells had to be removed from charge before completion of the respective tests due to high pressure.

Christy, D. E.↗

The electrical power subsystem of the Pioneer F/G spacecraft.

The Pioneer F/G spacecraft is the first to use radioisotope thermoelectric generators (RTG's) for a long duration interplanetary mission. This paper describes the design of the spacecraft power subsystem which meets the unique requirements of such a mission. The primary power source consists of four SNAP 19 RTG's. The 4.2 volt dc outputs of the RTG's are inverted to higher voltage ac by four inverters which are connected in parallel at their outputs. A power control unit (PCU) regulates the ac output of the inverters such that the RTG's are operated at near maximum power voltage throughout the mission. The PCU also contains charge and discharge controls for a silver cadmium battery which supplements the RTG's if load requirements temporarily exceed RTG power output. Battery reliability is enhanced by overcharge and cell reversal protection electronics which are provided for each cell. Multiple, low voltage, regulated dc outputs which supply power to the spacecraft subsystems are provided by a central transformer-rectifier-filter unit (CTRF). The CTRF operates directly from the regulated ac bus.

Reppucci, G. M.↗

The Atmosphere Explorer power subsystem

The design and operation of the power subsystem for the Atmospheric Explorer spacecraft are discussed. The additional functional redundancy which was added in several component areas to improve the overall subsystem reliability is analyzed. The battery charging technique has been modified to include third electrode overcharge control. The automatic removal of all battery charge is provided to correct abnormally high battery voltages. An undervoltage detector has been added which removes all nonessential spacecraft loads when the battery voltage falls below a given level. All automatic functions can be over-ridden by ground command.

Obenschain, A.↗

Fabrication and testing of negative limited sealed nickel-cadmium cells

A number of 20 Ah and 3 Ah negative limited nickel-cadmium cells were fabricated and assembled in hermetically sealed stainless steel containers. The cells exhibit a large voltage rise signal, in excess of 250 mA, at the end of each charge period. They also exhibit lower self discharge rates than conventional sealed nickel-cadmium cells and do not require overcharge. The cells are capable of operating at charge and discharge rates up to 5C and can deliver at least 1000 cycles on a 30 minute regime at 25% DOD. A small amount of gassing occurs, but is not deemed critical or detrimental in view of the facts that, (1) operating pressures are in the range of 7 to 20 psig and (2) the cells are operated in the flooded condition so therefore contain little internal void volume. The cells were found to exhibit somewhat higher capacity loss rates during cycling than conventional sealed nickel-cadmium batteries.

Gordy, D. J.↗