Search NASA⌕ Search

SEARCH · Search NASA

Results for “oversampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

High‐speed 4‐dimensional scanning transmission electron microscopy using compressive sensing techniques

Abstract Here we show that compressive sensing allows 4‐dimensional (4‐D) STEM data to be obtained and accurately reconstructed with both high‐speed and reduced electron fluence. The methodology needed to achieve these results compared to conventional 4‐D approaches requires only that a random subset of probe locations is acquired from the typical regular scanning grid, which immediately generates both higher speed and the lower fluence experimentally. We also consider downsampling of the detector, showing that oversampling is inherent within convergent beam electron diffraction (CBED) patterns and that detector downsampling does not reduce precision but allows faster experimental data acquisition. Analysis of an experimental atomic resolution yttrium silicide dataset shows that it is possible to recover over 25 dB peak signal‐to‐noise ratio in the recovered phase using 0.3% of the total data. Lay abstract : Four‐dimensional scanning transmission electron microscopy (4‐D STEM) is a powerful technique for characterizing complex nanoscale structures. In this method, a convergent beam electron diffraction pattern (CBED) is acquired at each probe location during the scan of the sample. This means that a 2‐dimensional signal is acquired at each 2‐D probe location, equating to a 4‐D dataset. Despite the recent development of fast direct electron detectors, some capable of 100kHz frame rates, the limiting factor for 4‐D STEM is acquisition times in the majority of cases, where cameras will typically operate on the order of 2kHz. This means that a raster scan containing 256^2 probe locations can take on the order of 30s, approximately 100‐1000 times longer than a conventional STEM imaging technique using monolithic radial detectors. As a result, 4‐D STEM acquisitions can be subject to adverse effects such as drift, beam damage, and sample contamination. Recent advances in computational imaging techniques for STEM have allowed for faster acquisition speeds by way of acquiring only a random subset of probe locations from the field of view. By doing this, the acquisition time is significantly reduced, in some cases by a factor of 10‐100 times. The acquired data is then processed to fill‐in or inpaint the missing data, taking advantage of the inherently low‐complex signals which can be linearly combined to recover the information. In this work, similar methods are demonstrated for the acquisition of 4‐D STEM data, where only a random subset of CBED patterns are acquired over the raster scan. We simulate the compressive sensing acquisition method for 4‐D STEM and present our findings for a variety of analysis techniques such as ptychography and differential phase contrast. Our results show that acquisition times can be significantly reduced on the order of 100‐300 times, therefore improving existing frame rates, as well as further reducing the electron fluence beyond just using a faster camera.

Robinson, Alex W.↗

A Machine Learning–Based Tire Life Prediction Framework for Increasing Life of Commercial Vehicle Tires

In the commercial freight industry, tire retreading decisions are often conservative due to limited knowledge of a tire’s remaining service life. This practice leads to increased costs and material waste. This paper proposes a machine learning–based approach for estimating tire casing life and retreadability, focusing on usage data rather than wear information. This approach could extend the tire’s lifespan and reduce landfill waste. Data integration from diverse tire casing measurement sources presents challenges, including imbalanced removal data. Our methodology addresses these challenges by using historical inspection, telematics, and finite element modeling (FEM) datasets. We introduce “Tire Casing Energy” as a comprehensive usage input and apply a Variance-Reduction Synthetic Minority Oversampling Technique (VR-SMOTE) for data imbalance rectification. A random forest model is used to estimate the state of the tire casing and the casing removal probability, with Bayesian optimization applied for hyperparameter tuning, enhancing model accuracy. Here, the proposed prediction framework is able to differentiate different truck fleets and tire locations based on their usage parameters. With the aid of this machine learning model, the importance and sensitivity of different tire usage parameters can be obtained, which is beneficial to maximize tire life.

Data balancing↗

Noise-resolution tradeoffs in x-ray CT imaging: A comparison of penalized alternating minimization and filtered backprojection algorithms

Purpose: In comparison with conventional filtered backprojection (FBP) algorithms for x-ray computed tomography (CT) image reconstruction, statistical algorithms directly incorporate the random nature of the data and do not assume CT data are linear, noiseless functions of the attenuation line integral. Thus, it has been hypothesized that statistical image reconstruction may support a more favorable tradeoff than FBP between image noise and spatial resolution in dose-limited applications. The purpose of this study is to evaluate the noise-resolution tradeoff for the alternating minimization (AM) algorithm regularized using a nonquadratic penalty function. Methods: Idealized monoenergetic CT projection data with Poisson noise were simulated for two phantoms with inserts of varying contrast (7%-238%) and distance from the field-of-view (FOV) center (2-6.5 cm). Images were reconstructed for the simulated projection data by the FBP algorithm and two penalty function parameter values of the penalized AM algorithm. Each algorithm was run with a range of smoothing strengths to allow quantification of the noise-resolution tradeoff curve. Image noise is quantified as the standard deviation in the water background around each contrast insert. Modulation transfer functions (MTFs) were calculated from six-parameter model fits to oversampled edge-spread functions defined by the circular contrast-insert edges as a metric of local resolution. The integral of the MTF up to 0.5 lp/mm was adopted as a single-parameter measure of local spatial resolution. Results: The penalized AM algorithm noise-resolution tradeoff curve was always more favorable than that of the FBP algorithm. While resolution and noise are found to vary as a function of distance from the FOV center differently for the two algorithms, the ratio of noises when matching the resolution metric is relatively uniform over the image. The ratio of AM-to-FBP image variances, a predictor of dose-reduction potential, was strongly dependent on the shape of the AM's nonquadratic penalty function and was also strongly influenced by the contrast of the insert for which resolution is quantified. Dose-reduction potential, reported here as the fraction (%) of FBP dose necessary for AM to reconstruct an image with comparable noise and resolution, for one penalty parameter value of the AM algorithm was found to vary from 70% to 50% for low-contrast and high-contrast structures, respectively, and from 70% to 10% for the second AM penalty parameter value. However, the second penalty, AM-700, was found to suffer from poor low-contrast resolution when matching the high-contrast resolution metric with FBP. Conclusions: The results of this simulation study imply that penalized AM has the potential to reconstruct images with similar noise and resolution using a fraction (10%-70%) of the FBP dose. However, this dose-reduction potential depends strongly on the AM penalty parameter and the contrast magnitude of the structures of interest. In addition, the authors' results imply that the advantage of AM can be maximized by optimizing the nonquadratic penalty function to the specific imaging task of interest. Future work will extend the methods used here to quantify noise and resolution in images reconstructed from real CT data.

60 APPLIED LIFE SCIENCES↗

Nonrigid registration-based coronary artery motion correction for cardiac computed tomography

Purpose: X-ray computed tomography angiography (CTA) is the modality of choice to noninvasively monitor and diagnose heart disease with coronary artery health and stenosis detection being of particular interest. Reliable, clinically relevant coronary artery imaging mandates high spatiotemporal resolution. However, advances in intrinsic scanner spatial resolution (CT scanners are available which combine nearly 900 detector columns with focal spot oversampling) can be tempered by motion blurring, particularly in patients with unstable heartbeats. As a result, recently numerous methods have been devised to improve coronary CTA imaging. Solutions involving hardware, multisector algorithms, or {beta}-blockers are limited by cost, oversimplifying assumptions about cardiac motion, and populations showing contraindications to drugs, respectively. This work introduces an inexpensive algorithmic solution that retrospectively improves the temporal resolution of coronary CTA without significantly affecting spatial resolution. Methods: Given the goal of ruling out coronary stenosis, the method focuses on 'deblurring' the coronary arteries. The approach makes no assumptions about cardiac motion, can be used on exams acquired at high heart rates (even over 75 beats/min), and draws on a fast and accurate three-dimensional (3D) nonrigid bidirectional labeled point matching approach to estimate the trajectories of the coronary arteries during image acquisition. Motion compensation is achieved by employing a 3D warping of a series of partial reconstructions based on the estimated motion fields. Each of these partial reconstructions is created from data acquired over a short time interval. For brevity, the algorithm 'Subphasic Warp and Add' (SWA) reconstruction. Results: The performance of the new motion estimation-compensation approach was evaluated by a systematic observer study conducted using nine human cardiac CTA exams acquired over a range of average heart rates between 68 and 86 beats/min. Algorithm performance was based-lined against exams reconstructed using standard filtered-backprojection (FBP). The study was performed by three experienced reviewers using the American Heart Association's 15-segment model. All vessel segments were evaluated to quantify their viability to allow a clinical diagnosis before and after motion estimation-compensation using SWA. To the best of the authors' knowledge this is the first such observer study to show that an image processing-based software approach can improve the clinical diagnostic value of CTA for coronary artery evaluation. Conclusions: Results from the observer study show that the SWA method described here can dramatically reduce coronary artery motion and preserve real pathology, without affecting spatial resolution. In particular, the method successfully mitigated motion artifacts in 75% of all initially nondiagnostic coronary artery segments, and in over 45% of the cases this improvement was enough to make a previously nondiagnostic vessel segment clinically diagnostic.

60 APPLIED LIFE SCIENCES↗

SU-E-J-183: Quantifying the Image Quality and Dose Reduction of Respiratory Triggered 4D Cone-Beam Computed Tomography with Patient- Measured Breathing

Purpose: Respiratory triggered four dimensional cone-beam computed tomography (RT 4D CBCT) is a novel technique that uses a patient's respiratory signal to drive the image acquisition with the goal of imaging dose reduction without degrading image quality. This work investigates image quality and dose using patient-measured respiratory signals for RT 4D CBCT simulations instead of synthetic sinusoidal signals used in previous work. Methods: Studies were performed that simulate a 4D CBCT image acquisition using both the novel RT 4D CBCT technique and a conventional 4D CBCT technique from a database of oversampled Rando phantom CBCT projections. A database containing 111 free breathing lung cancer patient respiratory signal files was used to create 111 RT 4D CBCT and 111 conventional 4D CBCT image datasets from realistic simulations of a 4D RT CBCT system. Each of these image datasets were compared to a ground truth dataset from which a root mean square error (RMSE) metric was calculated to quantify the degradation of image quality. The number of projections used in each simulation is counted and was assumed as a surrogate for imaging dose. Results: Based on 111 breathing traces, when comparing RT 4D CBCT with conventional 4D CBCT the average image quality was reduced by 7.6%. However, the average imaging dose reduction was 53% based on needing fewer projections (617 on average) than conventional 4D CBCT (1320 projections). Conclusion: The simulation studies using a wide range of patient breathing traces have demonstrated that the RT 4D CBCT method can potentially offer a substantial saving of imaging dose of 53% on average compared to conventional 4D CBCT in simulation studies with a minimal impact on image quality. A patent application (PCT/US2012/048693) has been filed which is related to this work.

60 APPLIED LIFE SCIENCES↗

SU-E-T-217: Intrinsic Respiratory Gating in Small Animal CT

Purpose: Preclinical animal models of lung cancer can provide a controlled test-bed for testing dose escalation or function-based-treatment-planning studies. However, to extract lung function, i.e. ventilation, one needs to be able to image the lung at different phases of ventilation (in-hale / ex-hale). Most respiratory-gated imaging using micro-CT involves using an external ventilator and surgical intervention limiting the utility in longitudinal studies. A new intrinsic respiratory retrospective gating method was developed and tested in mice. Methods: A fixed region of interest (ROI) that covers the diaphragm was selected on all projection images to estimate the mean intensity (M). The mean intensity depends on the projection angle and diaphragm position. A 3-point moving average (A) of consecutive M values: Mpre, Mcurrent and Mpost, was calculated to be subtracted from Mcurrent. A fixed threshold was used to enable amplitude based sorting into 4 different phases of respiration. Images at full-inhale and end-exhale phases of respiration were reconstructed using the open source OSCaR. Lung volumes estimated at the 2 phases of respiration were validated against literature values. Results: Intrinsic retrospective gating was accomplished without the use of any external breathing waveform. While projection images were acquired at 360 different angles. Only 138 and 104 projections were used to reconstruct images at full-inhale and end-exhale. This often results in non-uniform under-sampled angular projections leading to some minor streaking artifacts. The calculated expiratory, inspiratory and tidal lung volumes correlated well with the values known from the literature. Conclusion: Our initial result demonstrates an intrinsic gating method that is suitable for flat panel cone beam small animal CT systems. Reduction in streaking artifacts can be accomplished by oversampling the data or using iterative reconstruction methods. This initial experience will enable freebreathing small animal micro-CT imaging to fuel longitudinal studies of lung function.

60 APPLIED LIFE SCIENCES↗

Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: A digital phantom study

Purpose: Prospective respiratory-gated 4D CT has been shown to reduce tumor image artifacts by up to 50% compared to conventional 4D CT. However, to date no studies have quantified the impact of gated 4D CT on normal lung tissue imaging, which is important in performing dose calculations based on accurate estimates of lung volume and structure. To determine the impact of gated 4D CT on thoracic image quality, the authors developed a novel simulation framework incorporating a realistic deformable digital phantom driven by patient tumor motion patterns. Based on this framework, the authors test the hypothesis that respiratory-gated 4D CT can significantly reduce lung imaging artifacts. Methods: Our simulation framework synchronizes the 4D extended cardiac torso (XCAT) phantom with tumor motion data in a quasi real-time fashion, allowing simulation of three 4D CT acquisition modes featuring different levels of respiratory feedback: (i) “conventional” 4D CT that uses a constant imaging and couch-shift frequency, (ii) “beam paused” 4D CT that interrupts imaging to avoid oversampling at a given couch position and respiratory phase, and (iii) “respiratory-gated” 4D CT that triggers acquisition only when the respiratory motion fulfills phase-specific displacement gating windows based on prescan breathing data. Our framework generates a set of ground truth comparators, representing the average XCAT anatomy during beam-on for each of ten respiratory phase bins. Based on this framework, the authors simulated conventional, beam-paused, and respiratory-gated 4D CT images using tumor motion patterns from seven lung cancer patients across 13 treatment fractions, with a simulated 5.5 cm{sup 3} spherical lesion. Normal lung tissue image quality was quantified by comparing simulated and ground truth images in terms of overall mean square error (MSE) intensity difference, threshold-based lung volume error, and fractional false positive/false negative rates. Results: Averaged across all simulations and phase bins, respiratory-gating reduced overall thoracic MSE by 46% compared to conventional 4D CT (p ∼ 10{sup −19}). Gating leads to small but significant (p < 0.02) reductions in lung volume errors (1.8%–1.4%), false positives (4.0%–2.6%), and false negatives (2.7%–1.3%). These percentage reductions correspond to gating reducing image artifacts by 24–90 cm{sup 3} of lung tissue. Similar to earlier studies, gating reduced patient image dose by up to 22%, but with scan time increased by up to 135%. Beam paused 4D CT did not significantly impact normal lung tissue image quality, but did yield similar dose reductions as for respiratory-gating, without the added cost in scanning time. Conclusions: For a typical 6 L lung, respiratory-gated 4D CT can reduce image artifacts affecting up to 90 cm{sup 3} of normal lung tissue compared to conventional acquisition. This image improvement could have important implications for dose calculations based on 4D CT. Where image quality is less critical, beam paused 4D CT is a simple strategy to reduce imaging dose without sacrificing acquisition time.

60 APPLIED LIFE SCIENCES↗

Statistical iterative reconstruction to improve image quality for digital breast tomosynthesis

Purpose: Digital breast tomosynthesis (DBT) is a novel modality with the potential to improve early detection of breast cancer by providing three-dimensional (3D) imaging with a low radiation dose. 3D image reconstruction presents some challenges: cone-beam and flat-panel geometry, and highly incomplete sampling. A promising means to overcome these challenges is statistical iterative reconstruction (IR), since it provides the flexibility of accurate physics modeling and a general description of system geometry. The authors’ goal was to develop techniques for applying statistical IR to tomosynthesis imaging data. Methods: These techniques include the following: a physics model with a local voxel-pair based prior with flexible parameters to fine-tune image quality; a precomputed parameter λ in the prior, to remove data dependence and to achieve a uniform resolution property; an effective ray-driven technique to compute the forward and backprojection; and an oversampled, ray-driven method to perform high resolution reconstruction with a practical region-of-interest technique. To assess the performance of these techniques, the authors acquired phantom data on the stationary DBT prototype system. To solve the estimation problem, the authors proposed an optimization-transfer based algorithm framework that potentially allows fewer iterations to achieve an acceptably converged reconstruction. Results: IR improved the detectability of low-contrast and small microcalcifications, reduced cross-plane artifacts, improved spatial resolution, and lowered noise in reconstructed images. Conclusions: Although the computational load remains a significant challenge for practical development, the superior image quality provided by statistical IR, combined with advancing computational techniques, may bring benefits to screening, diagnostics, and intraoperative imaging in clinical applications.

60 APPLIED LIFE SCIENCES↗

Statistical-learning strategies generate only modestly performing predictive models for urinary symptoms following external beam radiotherapy of the prostate: A comparison of conventional and machine-learning methods

Purpose: Given the paucity of available data concerning radiotherapy-induced urinary toxicity, it is important to ensure derivation of the most robust models with superior predictive performance. This work explores multiple statistical-learning strategies for prediction of urinary symptoms following external beam radiotherapy of the prostate. Methods: The performance of logistic regression, elastic-net, support-vector machine, random forest, neural network, and multivariate adaptive regression splines (MARS) to predict urinary symptoms was analyzed using data from 754 participants accrued by TROG03.04-RADAR. Predictive features included dose-surface data, comorbidities, and medication-intake. Four symptoms were analyzed: dysuria, haematuria, incontinence, and frequency, each with three definitions (grade ≥ 1, grade ≥ 2 and longitudinal) with event rate between 2.3% and 76.1%. Repeated cross-validations producing matched models were implemented. A synthetic minority oversampling technique was utilized in endpoints with rare events. Parameter optimization was performed on the training data. Area under the receiver operating characteristic curve (AUROC) was used to compare performance using sample size to detect differences of ≥0.05 at the 95% confidence level. Results: Logistic regression, elastic-net, random forest, MARS, and support-vector machine were the highest-performing statistical-learning strategies in 3, 3, 3, 2, and 1 endpoints, respectively. Logistic regression, MARS, elastic-net, random forest, neural network, and support-vector machine were the best, or were not significantly worse than the best, in 7, 7, 5, 5, 3, and 1 endpoints. The best-performing statistical model was for dysuria grade ≥ 1 with AUROC ± standard deviation of 0.649 ± 0.074 using MARS. For longitudinal frequency and dysuria grade ≥ 1, all strategies produced AUROC>0.6 while all haematuria endpoints and longitudinal incontinence models produced AUROC<0.6. Conclusions: Logistic regression and MARS were most likely to be the best-performing strategy for the prediction of urinary symptoms with elastic-net and random forest producing competitive results. The predictive power of the models was modest and endpoint-dependent. New features, including spatial dose maps, may be necessary to achieve better models.

60 APPLIED LIFE SCIENCES↗

SU-F-I-54: Spatial Resolution Studies in Proton CT Using a Phase-II Prototype Head Scanner

Purpose: To characterize the modulation transfer function (MTF) of the pre-clinical (phase II) head scanner developed for proton computed tomography (pCT) by the pCT collaboration. To evaluate the spatial resolution achievable by this system. Methods: Our phase II proton CT scanner prototype consists of two silicon telescopes that track individual protons upstream and downstream from a phantom, and a 5-stage scintillation detector that measures a combination of the residual energy and range of the proton. Residual energy is converted to water equivalent path length (WEPL) of the protons in the scanned object. The set of WEPL values and associated paths of protons passing through the object over a 360° angular scan is processed by an iterative parallelizable reconstruction algorithm that runs on GP-GPU hardware. A custom edge phantom composed of water-equivalent polymer and tissue-equivalent material inserts was constructed. The phantom was first simulated in Geant4 and then built to perform experimental beam tests with 200 MeV protons at the Northwestern Medicine Chicago Proton Center. The oversampling method was used to construct radial and azimuthal edge spread functions and modulation transfer functions. The spatial resolution was defined by the 10% point of the modulation transfer function in units of lp/cm. Results: The spatial resolution of the image was found to be strongly correlated with the radial position of the insert but independent of the relative stopping power of the insert. The spatial resolution varies between roughly 4 and 6 lp/cm in both the the radial and azimuthal directions depending on the radial displacement of the edge. Conclusion: The amount of image degradation due to our detector system is small compared with the effects of multiple Coulomb scattering, pixelation of the image and the reconstruction algorithm. Improvements in reconstruction will be made in order to achieve the theoretical limits of spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multivariate Testing of Sampling Techniques to Address Class Imbalance in Building Use Type Classification

This study addresses the challenges inherent in building use type classification, particularly focusing on the issue of class imbalance in the training datasets for machine learning classifiers. We comprehensively analyze the efficacy of various class-balancing sampling techniques. Employing Monte Carlo simulations and Bayesian optimization, we evaluated the performance of multiple sampling methods, including Random Oversampling, Random Undersampling, SMOTE, Borderline-SMOTE, and ADASYN, across a dataset encompassing nine southeastern coastal states of the United States. Our findings reveal that simple random over- and undersampling techniques outperform more sophisticated methods. Additionally, we show inherent value in creating an imbalance in training data to effectively train a machine learning classifier for distinguishing between residential and nonresidential buildings. This study provides valuable guidance for future research on building use type classification research and lays essential groundwork for developing attribute-rich building stock datasets.

Adams, Daniel↗

NEURAL NETWORK FOR COHERENT DIFFRACTION IMAGE INVERSION

A deep neural network model plus automatic differentiation is developed for retrieving phase information from 3D coherent diffraction images. The model is implemented using Tensorflow and the training dataset is generated using physics-based atomistic simulations. Custom codes are written to handle the resampling of diffraction images to oversampling ratios appropriate for the neural network model.

CHAN, HENRY↗

Phase and amplitude retrieval of objects embedded in a sinusoidal background from its diffraction pattern

Efforts of phase and amplitude retrieval from diffraction patterns have almost exclusively been applied for nonperiodic objects. We investigated the quality of retrieval of nonperiodic objects embedded in a sinusoidal background, using the approach of iterative hybrid input-output with oversampling. Two strategies were employed; one by filtering in the frequency domain prior to phase retrieval, and the other by filtering the phase or amplitude image after retrieval. Results obtained indicate better outcomes with the latter approach provided detector noise is not excessive.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PVMapper: Report on the Second Public Opinion Survey

This report has been developed as an integral part of the PVMapper project, funded by the U.S. Department of Energy’s Office of Energy Efficiency and Renewable Energy’s SunShot program. The objective of the SunShot program is to reduce the total costs of solar energy systems. The scope of PVMapper is to develop a geographic information system (GIS) based project planning tool to identify optimal utility-scale solar facility sites. The specific objectives of the project are to 1) develop the software on an open-source platform; 2) integrate the appropriate data sets and GIS layers; 3) include a measure of social risk and public acceptance; 4) enable customization of variable weights; 5) provide a free and accessible platform for software download; and 6) provide a sustainability plan to ensure future relevance of the software. When completed, PVMapper is intended to be used by solar developers, Authorities Having Jurisdiction (AHJs), and other interested parties. This project supports SunShot’s objective by reducing the non-hardware balance of system costs (“soft costs”) for utility-scale solar project development. In order to accomplish the third project objective – including a measure of social risk and public acceptance within PVMapper – the project team has developed a time-series public opinion survey, administered yearly over the course of the three-year project. This report highlights the results and preliminary analyses from the second survey in this series. While the results of this survey are valuable to both PVMapper and future utility-scale solar development, the time-series design is extremely important. The completion of the series enables the extension of the dataset to much richer information. For example, the research team altered this iteration to sharpen the focus on specific topics (those posing potentially higher risks) and target specific locations in the oversample (such as communities near existing facilities). Using similar approaches for each iteration leads to an increasingly greater amount of detail regarding siting risks. The need for this extended dataset to aid in siting utility-scale solar projects is evident, as developers continue to scale back initial plans due to unidentified or incorrectly quantified social risks. It should be noted that this report provides the complete dataset from the survey, encompassing the wide-ranging responses from all of the survey questions. Although the methods used to integrate these data into PVMapper’s siting algorithms is not the purpose of this report, allusions to integration can be found in the discussions surrounding the design of questions and types of data to be used.

14 SOLAR ENERGY↗

Fast Approximate Union Volume in High Dimensions with Line Samples

The classical problem of calculating the volume of the union of d-dimensional balls is known as "Union Volume." We present line-sampling approximation algorithms for Union Volume. Our methods may be extended to other Boolean operations, such as setminus; or to other shapes, such as hyper-rectangles. The deterministic, exact approaches for Union Volume do not scale well to high dimensions. However, we adapt several of these exact approaches to approximation algorithms based on sampling. We perform local sampling within each ball using lines. We have several variations, depending on how the overlapping volume is partitioned, and depending on whether radial, axis-aligned, or other line patterns are used. Our variations fall within the family of Monte Carlo sampling, and hence have about the same theoretical convergence rate, 1 /$\sqrt{M}$, where M is the number of samples. In our limited experiments, line-sampling proved more accurate per unit work than point samples, because a line sample provides more information, and the analytic equation for a sphere makes the calculation almost as fast. We performed a limited empirical study of the efficiency of these variations. We suggest a more extensive study for future work. We speculate that different ball arrangements, differentiated by the distribution of overlaps in terms of volume and degree, will benefit the most from patterns of line samples that preferentially capture those overlaps. Acknowledgement We thank Karl Bringman for explaining his BF-ApproxUnion (ApproxUnion) algorithm [3] to us. We thank Josiah Manson for pointing out that spoke darts oversample the center and we might get a better answer by uniform sampling. We thank Vijay Natarajan for suggesting random chord sampling. The authors are grateful to Brian Adams, Keith Dalbey, and Vicente Romero for useful technical discussions. This work was sponsored by the Laboratory Directed Research and Development (LDRD) Program at Sandia National Laboratories. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Advanced Scientific Computing Research (ASCR), Applied Mathematics Program. Sandia National Laboratories is a multi-mission laboratory managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

97 MATHEMATICS AND COMPUTING↗

Femtosecond Diffractive Imaging with a Soft-X-Ray Free-Electron Laser

Theory predicts that with an ultrashort and extremely bright coherent X-ray pulse, a single diffraction pattern may be recorded from a large macromolecule, a virus, or a cell before the sample explodes and turns into a plasma. Here we report the first experimental demonstration of this principle using the FLASH soft X-ray free-electron laser. An intense 25 fs, 4 x 10{sup 13} W/cm{sup 2} pulse, containing 10{sup 12} photons at 32 nm wavelength, produced a coherent diffraction pattern from a nano-structured non-periodic object, before destroying it at 60,000 K. A novel X-ray camera assured single photon detection sensitivity by filtering out parasitic scattering and plasma radiation. The reconstructed image, obtained directly from the coherent pattern by phase retrieval through oversampling, shows no measurable damage, and extends to diffraction-limited resolution. A three-dimensional data set may be assembled from such images when copies of a reproducible sample are exposed to the beam one by one.

Other,PHYS↗

Data for The utility of transfer learning to improve the performance of deep learning in axon segmentation

The utility of transfer learning to improve the performance of deep learning in axon segmentation Data Data: All the input and labeled volumes tf-logs: Tensorflow logs, view with command "tensorboard --logdir [name of folder]" Model Weights: model_weights: the argument list under variable combo indicate 1) no oversampling, 2) no rotation, 3) no learn scheduler, and 4) flipping on all three dimensions, and the additional values indicate 5) elastic deformation percentage, 6) rotate deformation percentage, 7) layer setting , 8) learning rate, and 9) training/validation/test data division suffix (leave '' if not using suffix). Results: Output from inference segment_total_results_validation_final: All validation results and calculations segment_total_results: All test results and calculations Authors The modified code was created for a paper by: Marjolein Oostrom, Michael A. Muniak, Rogene Eichler West, Sarah Akers, Paritosh Pande, Moses Obiri, Wei Wang, Kasey Bowyer, Zhuhao Wu, Lisa Bramer, Tianyi Mao, Bobbie Jo Webb-Robertson The work is adapted from Github TrailMap, which was created by Albert Pun and Drew Friedmann Acknowledgments MO, RMEW, SA, MO, LB, BJWR were supported by the Laboratory Directed Research and Development at Pacific Northwest National Laboratory (PNNL), a Department of Energy facility operated by Battelle under contract DE-AC05-76RLO01830. WW, KB, and ZW were supported in part by a NIH/BRAIN Initiative Grant RF1MH128969. MAM and TM were supported by two NIH/BRAIN Initiative Grants R01NS104944, RF1MH120119 and NIH R01NS081071. This research is affiliated with the Pacific northwest bioMedical Innovation Co-laboratory (PMedIC) collaboration between OHSU and PNNL.

Oostrom, Marjolein T↗

Classification Analysis of Southwest Pacific Tropical Cyclone Intensity Changes Prior to Landfall

This study evaluates the ability of a random forest classifier to identify tropical cyclone (TC) intensification or weakening prior to landfall over the western region of the Southwest Pacific Ocean (SWPO) basin. For both Australia mainland and SWPO island cases, when a TC first crosses land after spending ≥24 h over the ocean, the closest hour prior to the intersection is considered as the landfall hour. If the maximum wind speed (V max ) at the landfall hour increased or remained the same from the 24-h mark prior to landfall, the TC is labeled as intensifying and if the V max at the landfall hour decreases, the TC is labeled as weakening. Geophysical and aerosol variables closest to the 24 h before landfall hour were collected for each sample. The random forest model with leave-one-out cross validation and the random oversampling example technique was identified as the best-performing classifier for both mainland and island cases. The model identified longitude, initial intensity, and sea skin temperature as the most important variables for the mainland and island landfall classification decisions. Incorrectly classified cases from the test data were analyzed by sorting the cases by their initial intensity hour, landfall hour, monthly distribution, and 24-h intensity changes. TC intensity changes near land strongly impact coastal preparations such as wind damage and flood damage mitigations; hence, this study will contribute to improve identifying and prioritizing prediction of important variables contributing to TC intensity change before landfall.

54 ENVIRONMENTAL SCIENCES↗