Search NASA⌕ Search

SEARCH · Search NASA

Results for “parameter selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Modeling land use and land cover change: using a hindcast to estimate economic parameters in gcamland v2.0

Abstract. Future changes in land use and cover have important implications for agriculture, energy, water use, and climate. Estimates of future land use and land cover differ significantly across economic models as a result of differences in drivers, model structure, and model parameters; however, these models often rely on heuristics to determine model parameters. In this study, we demonstrate a more systematic and empirically based approach to estimating a few key parameters for an economic model of land use and land cover change, gcamland. Specifically, we generate a large set of model parameter perturbations for the selected parameters and run gcamland simulations with these parameter sets over the historical period in the United States to quantify land use and land cover, determine how well the model reproduces observations, and identify parameter combinations that best replicate observations, assuming other model parameters are fixed. We also test alternate methods for forming expectations about uncertain crop yields and prices, including adaptive, perfect, linear, and hybrid approaches. In particular, we estimate parameters for six parameters used in the formation of expectations and three of seven logit exponents for the USA only. We find that an adaptive expectation approach minimizes the error between simulated outputs and observations, with parameters that suggest that for most crops, landowners put a significant weight on previous information. Interestingly, for corn, where ethanol policies have led to a rapid growth in demand, the resulting parameters show that a larger weight is placed on more recent information. We examine the change in model parameters as the metric of model error changes, finding that the measure of model fitness affects the choice of parameter sets. Finally, we discuss how the methodology and results used in this study could be used for other regions or economic models to improve projections of future land use and land cover change.

54 ENVIRONMENTAL SCIENCES↗

Design study of a feedback control system for the Multicyclic Flap System rotor (MFS)

The feasibility of automatically providing higher harmonic control to a deflectable control flap at the tip of a helicopter rotor blade through feedback of selected independent parameter was investigated. Control parameters were selected for input to the feedback system. A preliminary circuit was designed to condition the selected parameters, weigh limiting factors, and provide a proper output signal to the multi-cyclic control actuators. Results indicate that feedback control for the higher harmonic is feasible; however, design for a flight system requires an extension of the present analysis which was done for one flight condition - 120 kts, 11,500 lbs gross weight and level flight.

Weisbrich, R.↗

A preliminary assessment of the accuracy of selected meteorological parameters determined from Nimbus 6 satellite profile data

Published rms errors in rawinsonde data and discrepancies between satellite and rawinsonde profile data for temperature, dewpoint temperature, mixing ratio, and wind speed. Satellite rms errors were found to be 2 to 3 times as large as those for rawinsonde data. Gradients of the preceding parameters were computed for both rawinsonde and satellite data and compared with means and near extreme values computed from the AVE 2 and AVE 4 experiments. In all cases, it was found that satellite data can be used to determine with relatively good accuracy the near extreme gradients but not those whose value does not exceed the average. Synoptic charts were prepared to show that patterns of temperature could be determined with relatively good accuracy, while those of dew point were not as good as those for temperature. Winds represented by cloud motion vectors (satellite winds) were compared with rawinsonde winds, and it was found that large gaps exist in satellite values for a given pressure level and that errors in the satellite determined concluded that satellite profile data are very useful in synoptic analysis, particularly in data sparse regions as well as regions where near extreme gradients exist in the measured parameters.

Scoggins, J. R.↗

A pilot modeling technique for handling-qualities research

A brief survey of the more dominant analysis techniques used in closed-loop handling-qualities research is presented. These techniques are shown to rely on so-called classical and modern analytical models of the human pilot which have their foundation in the analysis and design principles of feedback control. The optimal control model of the human pilot is discussed in some detail and a novel approach to the a priori selection of pertinent model parameters is discussed. Frequency domain and tracking performance data from 10 pilot-in-the-loop simulation experiments involving 3 different tasks are used to demonstrate the parameter selection technique. Finally, the utility of this modeling approach in handling-qualities research is discussed.

Hess, R. A.↗

Experiment K305: Quantitative analysis of selected bone parameters

The skeletal alterations induced by space flight were determined to be a reduced rate of periosteal bone formation in tibial and humeral diaphyses, a decreased trabecular bone volume, and an increased fat content of the bone marrow in the proximal tibial metaphysis. An increased incidence of arrest lines in flight animals suggested that periosteal bone formation may have ceased during space flight. Endosteal bone resorption was not affected markedly.

Wrongski, T. J.↗

Experiment K305: Quantitative analysis of selected bone parameters. Supplement 1: Effects of weightlessness on osteoblast differentiation in rat molar periodontium

The morphometric analysis of periodontal ligament (PDL), the osteogenic interface between tooth and bone, is described. Immediately post-flight, PDL width and total cell number were decreased. Frequency distributions of nuclear volume revealed that presumptive preosteoblasts were particularly depressed. Depleted numbers of preosteoblasts may be an important factor in the mechanism of inhibited bone formation during weightlessness.

Roberts, W. E.↗

Experiment K305: Quantitative analysis of selected bone parameters. Supplement 2: Bone elongation rate and bone mass in metaphysis of long bones

The proximal humeral metaphysis of rats from time periods recovery plus zero days (R+0), recovery plus six days (R+6), and recovery plus twenty nine days (R+29) was analyzed. The volume of calcified cartilage and bone in flight and synchronous controls was reduced in groups R+0 and R+6, but was normal in group R+29. The number of functional bone cells (osteoblasts and osteoclasts) was decreased in proportion to the amount of bone in the early groups, and was normal in the last group. The fatty marrow volume was increased only in flight animals of groups R+0 and R+6, but was normal in the R+29 group. Accumulation of excess fatty marrow was seen only in flight animals. The decreased amount of bone and calcified cartilage is believed to be the result of a temporarily slowed or arrested production of calcified cartilage as a substrate for bone formation. This would have resulted from slowed bone elongation during flight and synchronous control conditions. Bone elongation returned to normal by twenty nine days after return.

Jee, W. S. S.↗

Experiment K305: Quantitative analysis of selected bone parameters. Supplement 3A: Trabecular spacing and orientation in the long bones

Values of mean trabecular spacing computed from optical diffraction patterns of 1:1 X-ray micrographs of tibial metaphysis and those obtained by standard image digitization techniques show excellent agreement. Upper limits on values of mean trabecular orientation deduced from diffraction patterns and the images are also in excellent agreement. Values of the ratio of mean trabecular spatial density in a region of 300 micrometers distal to the downwardly directed convexity in the cartilage growth plate to the value adjacent to the plate determined for flight animals sacrificed at recovery were significantly smaller than values for vivarium control animals. No significant differences were found in proximal regions. No significant differences in mean trabecular orientation were detected. Decreased values of trabecular spatial density and of both obsteoblastic activity and trabecular cross-sectional area noted in collateral researches suggest decreased modeling activity under weightlessness.

Judy, M. M.↗

Experiment K305: Quantitative analysis of selected bone parameters. Supplement 3B: Mineralization in the long bones

Electron microscope and optical birefringent studies of growth plates and metaphyseal trabeculae are described. The type and functional state of bone cells were investigated and the zone of calcification of the cartilagenous growth plate, particularly the presence and condition of matrix vesicles, was characterized. Trabecular number, size, and orientation were assessed. Comparisons with a control group, indicating changes resulting from a zero gravity situation, are presented.

Matthews, J. L.↗

Trend analysis for large solid rocket motors - A program level approach

This paper defines a program-level trend analysis effort that can be applied to large solid rocket motors. The effort is especially applicable to large segmented rocket motors such as the Space Transportation System's solid rocket boosters. Five types of trend analysis are discussed for different aspects of a rocket motor program, (performance, reliability, problem, supportability, and programmatic). Ideas are offered for implementing and performing a program-level trend analysis effort by giving suggestions for selecting computer capabilities, choosing parameters, selecting statistical processes, routine screening for trends, analyzing significant trends (for example, looking for related trends and determining if adverse trends are resolved), and reporting results of trend analysis. The use of program-level trending allows for the ability to easily transfer data between organizations and easily use the data to correlate trends from the various organizations to find causal relationships. Efficiency is enhanced from upper level management to the shop floor at vendor locations by using the same trend analysis software and methodology at all organizations.

Babbitt, Norman E., III↗

Experimental evaluation and basis function optimization of the spatially variant image-space PSF on the Ingenuity PET/MR scanner

Purpose: The Ingenuity time-of-flight (TF) PET/MR is a recently developed hybrid scanner combining the molecular imaging capabilities of PET with the excellent soft tissue contrast of MRI. It is becoming common practice to characterize the system's point spread function (PSF) and understand its variation under spatial transformations to guide clinical studies and potentially use it within resolution recovery image reconstruction algorithms. Furthermore, due to the system's utilization of overlapping and spherical symmetric Kaiser-Bessel basis functions during image reconstruction, its image space PSF and reconstructed spatial resolution could be affected by the selection of the basis function parameters. Hence, a detailed investigation into the multidimensional basis function parameter space is needed to evaluate the impact of these parameters on spatial resolution. Methods: Using an array of 12 × 7 printed point sources, along with a custom made phantom, and with the MR magnet on, the system's spatially variant image-based PSF was characterized in detail. Moreover, basis function parameters were systematically varied during reconstruction (list-mode TF OSEM) to evaluate their impact on the reconstructed resolution and the image space PSF. Following the spatial resolution optimization, phantom, and clinical studies were subsequently reconstructed using representative basis function parameters. Results: Based on the analysis and under standard basis function parameters, the axial and tangential components of the PSF were found to be almost invariant under spatial transformations (∼4 mm) while the radial component varied modestly from 4 to 6.7 mm. Using a systematic investigation into the basis function parameter space, the spatial resolution was found to degrade for basis functions with a large radius and small shape parameter. However, it was found that optimizing the spatial resolution in the reconstructed PET images, while having a good basis function superposition and keeping the image representation error to a minimum, is feasible, with the parameter combination range depending upon the scanner's intrinsic resolution characteristics. Conclusions: Using the printed point source array as a MR compatible methodology for experimentally measuring the scanner's PSF, the system's spatially variant resolution properties were successfully evaluated in image space. Overall the PET subsystem exhibits excellent resolution characteristics mainly due to the fact that the raw data are not under-sampled/rebinned, enabling the spatial resolution to be dictated by the scanner's intrinsic resolution and the image reconstruction parameters. Due to the impact of these parameters on the resolution properties of the reconstructed images, the image space PSF varies both under spatial transformations and due to basis function parameter selection. Nonetheless, for a range of basis function parameters, the image space PSF remains unaffected, with the range depending on the scanner's intrinsic resolution properties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High Pressure Water Stripping Using Multi-Orifice Nozzles

The use of multi-orifice rotary nozzles greatly increases the speed and stripping effectiveness of high pressure water blasting systems, but also greatly increases the complexity of selecting and optimizing the operating parameters. The rotational speed of the nozzle must be coupled with its transverse velocity as it passes across the surface of the substrate being stripped. The radial and angular positions of each orifice must be included in the analysis of the nozzle configuration. Orifices at the outer edge of the nozzle head move at a faster rate than the orifices located near the center. The energy transmitted to the surface from the impact force of the water stream from an outer orifice is therefore spread over a larger area than energy from an inner orifice. Utilizing a larger diameter orifice in the outer radial positions increases the total energy transmitted from the outer orifice to compensate for the wider distribution of energy. The total flow rate from the combination of all orifices must be monitored and should be kept below the pump capacity while choosing orifice to insert in each position. The energy distribution from the orifice pattern is further complicated since the rotary path of all the orifices in the nozzle head pass through the center section. All orifices contribute to the stripping in the center of the path while only the outer most orifice contributes to the stripping at the edge of the nozzle. Additional orifices contribute to the stripping from the outer edge toward the center section. With all these parameters to configure and each parameter change affecting the others, a computer model was developed to track and coordinate these parameters. The computer simulation graphically indicates the cumulative affect from each parameter selected. The result from the proper choices in parameters is a well designed, highly efficient stripping system. A poorly chosen set of parameters will cause the nozzle to strip aggressively in some areas while leaving the coating untouched in adjacent sections. The high pressure water stripping system can be set to extremely aggressive conditions allowing stripping of hard to remove adhesives, paint systems, and even cladding and chromate conversion coatings. The energy force can also be reduced to strip coatings from thin aluminum substrates without causing any damage or deterioration to the substrate's surface. High pressure water stripping of aerospace components has thus proven to be an efficient and cost effective method for cleaning and removing coatings.

Hoppe, David↗

High Pressure Water Stripping Using Multi-Orifice Nozzles

The use of multi-orifice rotary nozzles not only increases the speed and stripping effectiveness of high pressure water blasting systems, but also greatly increases the complexity of selecting and optimizing the operating parameters. The rotational speed of the nozzle must be coupled with the transverse velocity of the nozzle as it passes across the surface of the substrate being stripped. The radial and angular positions of each orifice must be included in the analysis of the nozzle configuration. Since orifices at the outer edge of the nozzle head move at a faster rate than the orifice located near the center, the energy impact force of the water stream from the outer orifice is spread over a larger area than the water streams from the inner orifice. Utilizing a larger diameter orifice in the outer radial positions increases the energy impact to compensate for its wider force distribution. The total flow rate from the combination of orifices must be monitored and kept below the pump capacity while choosing an orifice to insert in each position. The energy distribution from the orifice pattern is further complicated since the rotary path of all orifices in the nozzle head pass through the center section, contributing to the stripping in this area while only the outer most orifice contributes to the stripping in the shell area at the extreme outside edge of the nozzle. From t he outer most shell to the center section, more orifices contribute to the stripping in each progressively reduced diameter shell. With all these parameters to configure and each parameter change affecting the others, a computer model was developed to track and coordinate these parameters. The computer simulation responds by graphically indicating the cumulative affect from each parameter selected. The results from the proper choices in parameters is a well designed, highly efficient stripping system. A poorly chosen set of parameters will cause the nozzle to strip aggressively in some areas while leaving the coating untouched in adjacent sections. The high pressure water stripping system can be set to extremely aggressive conditions allowing stripping of hard to remove adhesives, paint systems, cladding and chromate conversion coatings. The energy force can be reduced to strip coatings from thin aluminum substrates without causing damage or deterioration to the substrate's surface. High pressure water stripping of aerospace components have thus proven to be an efficient and cost effective method for cleaning and removing coatings.

Hoppe, David T.↗

Advanced Electrocardiography Can Identify Occult Cardiomyopathy in Doberman Pinschers

Recently, multiple advanced resting electrocardiographic (A-ECG) techniques have improved the diagnostic value of short-duration ECG in detection of dilated cardiomyopathy (DCM) in humans. This study investigated whether 12-lead A-ECG recordings could accurately identify the occult phase of DCM in dogs. Short-duration (3-5 min) high-fidelity 12-lead ECG recordings were obtained from 31 privately-owned, clinically healthy Doberman Pinschers (5.4 +/- 1.7 years, 11/20 males/females). Dogs were divided into 2 groups: 1) 19 healthy dogs with normal echocardiographic M-mode measurements: left ventricular internal diameter in diastole (LVIDd . 47mm) and in systole (LVIDs . 38mm) and normal 24-hour ECG recordings (<50 ventricular premature complexes, VPCs); and 2) 12 dogs with occult DCM: 11/12 dogs had increased M-mode measurements (LVIDd . 49mm and/or LVIDs . 40mm) and 5/11 dogs had also >100 VPCs/24h; 1/12 dogs had only abnormal 24-hour ECG recordings (>100 VPCs/24h). ECG recordings were evaluated via custom software programs to calculate multiple parameters of high-frequency (HF) QRS ECG, heart rate variability, QT variability, waveform complexity and 3-D ECG. Student's t-tests determined 19 ECG parameters that were significantly different (P < 0.05) between groups. Principal component factor analysis identified a 5-factor model with 81.4% explained variance. QRS dipolar and non-dipolar voltages, Cornell voltage criteria and QRS waveform residuum were increased significantly (P < 0.05), whereas mean HF QRS amplitude was decreased significantly (P < 0.05) in dogs with occult DCM. For the 5 selected parameters the prediction of occult DCM was performed using a binary logistic regression model with Chi-square tested significance (P < 0.01). ROC analyses showed that the five selected ECG parameters could identify occult ECG with sensitivity 89% and specificity 83%. Results suggest that 12-lead A-ECG might improve diagnostic value of short-duration ECG in earlier detection of canine DCM as five selected ECG parameters can with reasonable accuracy identify occult DCM in Doberman Pinschers. Future extensive clinical studies need to clarify if 12-lead A-ECG could be useful as an additional screening test for canine DCM.

Spiljak, M.↗