Search NASA⌕ Search

SEARCH · Search NASA

Results for “part load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Endpoint Use Efficiency Comparison for AC and DC Power Distribution in Commercial Buildings

Advances in power electronics and their use in Miscellaneous Electric Loads (MELs) in buildings have resulted in increased interest in using low-voltage direct current (DC) power distribution as a replacement for the standard alternating current (AC) power distribution in buildings. Both systems require an endpoint converter to convert the distribution system voltage to the MELs voltage requirements. This study focused on the efficiency of these endpoint converters by testing pairs of AC/DC and DC/DC power converters powering the same load profile. In contrast to prior studies, which estimated losses based on data sheet efficiency and rated loads, in this study, we used part load data derived from real-world time-series load measurements of MELs and experimentally characterized efficiency curves for all converters. The measurements performed for this study showed no systematic efficiency advantage for commercially available DC/DC endpoint converters relative to comparable, commercially available AC/DC endpoint converters. For the eight appliances analyzed with the pair of converters tested, in 50%, the weighted energy efficiency of the DC/DC converter was higher, while, for the other 50%, the AC/DC converter was. Additionally, the measurements indicated that the common assumption of using either data sheet efficiency values or efficiency at full load may result in substantial mis-estimates of the system efficiency.

AC/DC converters↗

Performance, Fuel Economy, and Economic Assessment of a Combustion Concept Employing In-Cylinder Gasoline/Natural Gas Blending for Light-Duty Vehicle Applications

In current production natural gas/gasoline bi-fuel vehicles, fuels are supplied via port fuel injection (PFI). Injecting a gaseous fuel in the intake port significantly reduces the volumetric efficiency and consequently torque as compared to gasoline. In addition to eliminating the volumetric efficiency challenge, direct injection (DI) of natural gas (NG) can enhance the in-cylinder flow, mixing, and combustion process resulting in improved efficiency and performance. A computational fluid dynamics (CFD) approach to model high-pressure gaseous injection was developed and validated against X-ray data from Argonne’s Advanced Photon Source. NG side and central DI of various designs and injection strategies were assessed experimentally along with CFD correlation. Significant effects on combustion metrics were quantified and explained via improved understanding of the in-cylinder flow effects due to NG injection. On-demand in-cylinder blending using E10 PFI and NG DI provides an additional lever to adjust in-cylinder turbulence as well as knock resistance across the engine speed and load range. NG DI improves part-load dilution tolerance due to higher in-cylinder turbulence and the high knock resistance of NG compared to E10 improves wide open throttle (WOT) performance while enabling increased compression ratios (CR). Vehicle level simulations suggest that implementing this strategy on a ½ ton pick-up truck with a naturally aspirated engine at 12.5:1 CR improves energy consumption on the aggressive US06 drive cycle by 15.5% compared to E10 operation, and gives a petroleum reduction of 78% over the blended range. There are challenges regarding market acceptance and widespread adoption of dual-fuel NG-gasoline vehicle applications beyond the performance degradation when the vehicle runs out of natural gas. Furthermore, those challenges include practical concerns such as loss of cargo volume and payload due to the NG storage tank, extended NG refueling times, fueling convenience due to gasoline and NG fuel tanks, and limited NG fueling infrastructure.

33 ADVANCED PROPULSION SYSTEMS↗

Cold Climate Heat Pumps Using Tandem Compressors

In cold climate zones, e.g. ASHRAE climate regions IV and V, conventional electric air-source heat pumps (ASHP) do not work well, due to high compressor discharge temperatures, large pressure ratios and inadequate heating capacities at low ambient temperatures. Consequently, significant use of auxiliary strip heating is required to meet the building heating load. We introduce innovative ASHP technologies as part of continuing efforts to eliminate auxiliary strip heat use and maximize heating COP with acceptable cost-effectiveness and reliability. These innovative ASHP were developed using tandem compressors, which are capable of augmenting heating capacity at low temperatures and maintain superior part-load operation efficiency at moderate temperatures. Two options of tandem compressors were studied; the first employs two identical, single-speed compressors, and the second employs two identical, vapor-injection compressors. The investigations were based on system modeling and laboratory evaluation. Both designs have successfully met the performance criteria. Laboratory evaluation showed that the tandem, single-speed compressor ASHP system is able to achieve heating COP = 4.2 at 47 F (8.3 C), COP = 2.9 at 17 F (-8.3 C), and 76% rated capacity and COP = 1.9 at -13 F (-25 C). This yields a HSPF = 11.0 (per AHRI 210/240). The tandem, vapor-injection ASHP is able to reach heating COP = 4.4 at 47 F, COP = 3.1 at 17 F, and 88% rated capacity and COP = 2.0 at -13 F. This yields a HSPF = 12.0. The system modeling and further laboratory evaluation are presented in the paper.

Shen, Bo↗

Evaluating the Impact of Off-Design CHP Performance on the Optimal Sizing and Dispatch on Hybrid Renewable-CHP Distributed Energy Resources

The maturation of distributed energy resources (DER) has prompted the exploration of their deployment in commercial building applications due to their potential to supply energy at lower costs and emissions rates compared to centralized generation. While several software tools exist for evaluating the techno-economic potential of integrated renewable energy and combined heat and power (CHP) systems for distributed generation applications, many suffer from poor accuracy in capturing off-design (part load and changes in ambient air temperature and pressure) performance characteristics of microturbines, combustion turbines, or internal combustion engines. Thus, this paper presents a methodology for integrating these off-design characteristics in the mixed-integer linear program within REopt, a hybrid DER screening tool. The economic impact of the CHP off-design performance is observed through several application studies of various hybrid system configurations in different climates. Each study indicates how CHP off-design performance influences optimal sizing and dispatch decisions and therefore overall system economic value. We observe through case studies that modeling without the off-design effects, depending on the CHP prime mover and site, can result in Net Present Value predictions of hybrid systems that can be overoptimistic in frequently hot climates (up to 52%), too conservative in frequently cold climates (up to 11%), or unaffected (+/-1%) in temperate climates. Cases also highlight several advantages of hybrid systems relative to non-hybrid systems such as total economic value and the systems' ability to mitigate potentially negative consequences attributed to off-design performance.

ambient de-rate↗

Shock Loading of Granular Ni/Al Composites. Part 1. Mechanics of Loading

We present molecular dynamics simulations of the thermomechanical response under shock loading of a granular material consisting of laminated Ni/Al grains. We observe two regimes: At low piston velocities (up ≲ 1km/s), the shock wave is diffuse, and the width of the shock front decreases with increasing piston velocity. Beyond a critical shock strength, however, the width remains relatively constant at approximately the mean grain radius. This change in behavior follows from an evolution of the mechanism of compaction with increasing insult strength. Furthermore, the mechanism evolves from plastic deformation-mediated pore collapse for relatively weak shocks, to solid extrusion and fluid ejecta filling pores ahead of the shock front at intermediate strengths, and finally to atomic jetting into the pore for very strong shocks (up ≳ 2 km/s). High-energy fluid ejecta into pores leads to the formation of flow vorticity and can result in a large fraction of the input energy localizing into translational kinetic energy components including the formation of hot spots. This has implications for the mechanical mixing of Ni and Al in these reactive composites.

36 MATERIALS SCIENCE↗

On Road vs. Off Road Low Load Cycle Comparison

Reducing criteria pollutants while reducing greenhouse gases is an active area of research for commercial on-road vehicles as well as for off-road machines. The heavy duty on-road sector has moved to reducing NOx by 82.5% compared to 2010 regulations while increasing the engine useful life from 435,000 to 650,000 miles by 2027 in the United States (US). An additional certification cycle, the Low Load Cycle (LLC), has been added focusing on part load operation having tight NOx emissions levels. In addition to NOx, the total CO2 emissions from the vehicle will also be reduced for various model years. The off-road market is following with a 90% NOx reduction target compared to Tier 4 Final for 130-560 kW engines along with greenhouse gas targets that are still being established. The off-road market will also need to certify with a Low Load Application Cycle (LLAC), a version of which was proposed for evaluation in 2021. Since the LLAC has not been finalized, this study is being conducted to compare and contrast the LLC for on-road with the LLAC for off-road as there might be some shared learnings. A US off-road production 2023 Fiat Powertrain 13L engine and aftertreatment system was chosen for this work. This engine is used in production for both off-road and on-road products, so it is a good choice for this study. The associated off-road aftertreatment system was aged for more relevant comparisons. The engine calibration was not altered for either of the low load cycles. This study shows that the cycles are quite different in nature as the market needs are different. The LLC includes a large fraction of operation at idle and lower speeds, representing products that use the engine primarily for motive power, where lower vehicle speed means a lower engine speed and load. The LLAC has more time and load spent at high speeds and slightly higher loads. The off-road products represented by this cycle often use the engine to drive auxiliary equipment which means higher parasitic loads and hand/fixed throttle. The comparison will include the use profiles, tailpipe NOx and greenhouse gas emissions (CO2, N2O).

McCarthy, James↗

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of repairability and repair quality on graphite/epoxy structural subelements

The considered program has the objective to develop and validate repair procedures for composite structures which are adaptable to commercial airline maintenance operations. Questions concerning the design and the fabrication of repairs are discussed, taking into account a vertical fin cover panel, a wing cover panel, and a vertical fin spar. The test results indicate that the use of graphite patch repairs, either precured bonded or employing cure-in-place, is satisfactory for the repair of lightly loaded and highly loaded parts. The use of bolted repairs is satisfactory for lightly loaded structural components. The repair of composite substructures can be accomplished using comparable approaches to those evaluated for skin cover repairs in many previous programs.

Knauss, J. F.↗

The effect of insulated combustion chamber surfaces on direct-injected diesel engine performance, emissions, and combustion

The combustion chamber of a single-cylinder, direct-injected diesel engine was insulated with ceramic coatings to determine the effect of low heat rejection (LHR) operation on engine performance, emissions, and combustion. In comparison to the baseline cooled engine, the LHR engine had lower thermal efficiency, with higher smoke, particulate, and full load carbon monoxide emissions. The unburned hydrocarbon emissions were reduced across the load range. The nitrous oxide emissions increased at some part-load conditions and were reduced slightly at full loads. The poor LHR engine performance was attributed to degraded combustion characterized by less premixed burning, lower heat release rates, and longer combustion duration compared to the baseline cooled engine.

Dickey, Daniel W.↗

Spur-Gear-System Efficiency at Part and Full Load

A simple method for predicting the part- and full-load power loss of a steel spur gearset of arbitrary geometry supported by ball bearings is described. The analysis algebraically accounts for losses due to gear sliding, rolling traction, and windage in addition to support-ball-bearing losses. The analysis compares favorably with test data. A theoretical comparison of the component losses indicates that losses due to gear rolling traction, windage, and support bearings are significant and should be included along with gear sliding loss in a calculation of gear-system power loss.

Anderson, N. E.↗

Evaluating Moisture Control of Variable-Capacity Heat Pumps in Mechanically Ventilated, Low-Load Homes in Climate Zone 2A

The well-sealed, highly insulated building enclosures constructed by today's home building industry coupled with efficient lighting and appliances are achieving significantly reduced heating and cooling loads. These low-load homes can present a challenge when selecting appropriate space-conditioning equipment. Conventional, fixed-capacity heating and cooling equipment is often oversized for small homes, causing increased first costs and operating costs. Even if fixed-capacity equipment can be properly specified for peak loads, it remains oversized for use during much of the year. During these part-load cooling hours, oversized equipment meets the target dry-bulb temperatures very quickly, often without sufficient opportunity for moisture control. The problem becomes more acute for high-performance houses in humid climates when meeting ASHRAE Standard 62.2 recommendations for wholehouse mechanical ventilation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BEEAM (Building Electrical Efficiency Analysis Model) [SWR-20-107]

Modern high-performance buildings exhibit an increasing number of building loads that use direct current (DC) electricity internally, rather than alternating current (AC), due to the advent of low-cost computing and advanced power electronics. Powering DC devices from the AC grid requires AC/DC power conversion, which introduces energy losses and reduces efficiency. As DC loads proliferate, the cumulative wasted energy associated with hundreds of millions of AC/DC converters has become one of the broadest energy savings opportunities in buildings. DC power distribution systems have been proposed as an elegant and transformative solution to the problem of DC devices. In a DC distribution system, the building's wires carry DC electricity, rather than AC; and a few centralized, highly efficient AC/DC converters replace the many smaller, less efficient converters that serve individual DC loads. Unfortunately, the trade-offs associated with DC distribution systems are not well understood. Reported energy savings associated with DC power distribution differ widely and have not been well validated. The Building Electrical Efficiency Analysis Model (BEEAM) is a Modelica library that simulates the efficiency of building electrical distribution systems using harmonic power flow. BEEAM can model a wide variety of building distribution topologies, including three-phase AC, single-phase AC, unipolar DC, bipolar DC, and hybrid networks under both balanced and unbalanced load conditions. BEEAM accurately models power electronic converter losses, provides granular estimates of losses throughout the distribution system, and properly models efficiency at part load conditions. Users can package BEEAM within a functional mockup unit (FMU), enabling co-simulation with other modeling platform, such as EnergyPlus. In summary, BEEAM provides a tool suite for fair and accurate comparison of the efficiency of building electrical distribution systems, including AC, DC, and hybrid systems.

Frank, Stephen↗

Actuator Exerts Tensile Or Compressive Axial Load

Compact, manually operated mechanical actuator applies controlled, limited tensile or compressive axial force. Designed to apply loads to bearings during wear tests in clean room. Intended to replace hydraulic actuator. Actuator rests on stand and imparts axial force to part attached to clevis inside or below stand. Technician turns control screw at one end of lever. Depending on direction of rotation of control screw, its end of lever driven downward (for compression) or upward (for tension). Lever pivots about clevis pin at end opposite of control screw; motion drives downward or upward link attached via shearpin at middle of lever. Link drives coupling and, through it, clevis attached to part loaded.

Nozzi, John↗

Performance and cost of automotive fuel cell systems with ultra-low platinum loadings.

An automotive polymer-electrolyte fuel cell (PEFC) system with ultra-low platinum loading (0.15 mg-Pt cm{sup -2}) has been analyzed to determine the relationship between its design-point efficiency and the system efficiency at part loads, efficiency over drive cycles, stack and system costs, and heat rejection. The membrane electrode assemblies in the reference PEFC stack use nanostructured, thin-film ternary catalysts supported on organic whiskers and a modified perfluorosulfonic acid membrane. The analyses show that the stack Pt content can be reduced by 50% and the projected high-volume manufacturing cost by >45% for the stack and by 25% for the system, if the design-point system efficiency is lowered from 50% to 40%. The resulting penalties in performance are a <1% reduction in the system peak efficiency; a 2-4% decrease in the system efficiency on the urban, highway, and LA92 drive cycles; and a 6.3% decrease in the fuel economy of the modeled hybrid fuel-cell vehicle on the combined cycle used by EPA for emission and fuel economy certification. The stack heat load, however, increases by 50% at full power (80 kW{sub e}) but by only 23% at the continuous power (61.5 kW{sub e}) needed to propel the vehicle on a 6.5% grade at 55 mph. The reduced platinum and system cost advantages of further lowering the design-point efficiency from 40% to 35% are marginal. The analyses indicate that thermal management in the lower efficiency systems is very challenging and that the radiator becomes bulky if the stack temperature cannot be allowed to increase to 90-95 C under driving conditions where heat rejection is difficult.

30 DIRECT ENERGY CONVERSION↗

Simulations of Multi-Mode Combustion Regimes Realizable In a Gasoline Direct Injection Engine

Lean and dilute gasoline compression ignition (GCI) operation in spark ignition (SI) engines are an attractive strategy to attain high fuel efficiency and low NOx levels. However, this combustion mode is often limited to low-load engine conditions due to the challenges associated with autoignition controllability. In order to overcome this constrain, multi-mode (MM) operating strategies, consisting of advanced compression ignition (ACI) at low load and conventional SI at high load, have been proposed. In this three-dimensional computational fluid dynamics study, the concept of multi-mode combustion using two RON98 gasoline fuel blends (Co-Optima Alkylate and E30) in a gasoline direct injection (GDI) engine were explored. To this end, a new reduced mechanism for simulating the kinetics of E30 fuel blend is introduced in this study. To cover the varying engine load demands for multi-mode engines, primary combustion dynamics observed in ACI and SI combustion modes was characterized and validated against experimental measurements. In order to implement part-load conditions, a strategy of mode transition between SI and ACI combustion (i.e., mixed-mode combustion) was then explored numerically by creating a virtual test condition. The results obtained from the mixed-mode simulations highlight an important feature that deflagrative flame propagation regime coexists with ignition-assisted end-gas autoignition. This study also identifies a role of turbulent flow property adjacent to premixed flame front in characterizing the mixed-mode combustion. The employed hybrid combustion model was verified to perform simulations aiming at suitable range of multi-mode engine operations.

Kim, Sayop↗

Case Study: NREL Campus Chilled Water Storage Potential: Benchmark Datasets Development and Applications, Task 4 - Use Case Demonstration

The Benchmark Datasets Development and Applications project is a three-year collaboration between the National Renewable Energy Laboratory (NREL), Oak Ridge National Laboratory, Pacific Northwest National Laboratory, and Lawrence Berkeley National Laboratory. The project seeks to collect and curate high-resolution, well-calibrated time series of building operational and indoor/outdoor environmental data, which are crucial to understanding and optimizing building energy efficiency performance and demand flexibility capabilities as well as benchmarking energy algorithms. Project outcomes include approximately twelve high-fidelity building datasets, enhanced data representation tools, and four case studies to illustrate example applications. The goal of these case studies is to define and execute analyses that demonstrate how one or more datasets collected through this project can address a data gap or challenge historically faced by building stakeholders. This technical paper summarizes the findings of one of these case studies, in which we studied the operational efficiencies of the central cooling system at NREL. We looked at three years of data from the three chillers in the Field Test Laboratory Building (FTLB), from 2019 to 2021, to compare equipment operation and demand throughout the time period. Our analysis indicates that all three chillers are operating at or below the optimal loading conditions for most of the operation time, and thus there was no efficiency drop due to loading of the chillers at full capacity. Our recommendation is that no chiller capacity increase is needed; instead, the central plant could benefit from adopting advanced control logics for optimal sequencing of chillers during part load operations. Analysis of adding chilled water thermal storage to the central plant indicated 34% savings in demand cost and 24.5% savings in total cost (energy consumption and demand charge cost). The payback period is estimated to be 11-22 years with an assumed TES cost of $\$$100-$200 per ton. This case study shows how a selected dataset is used to solve a practical building problem - learning the operational status of its components, analyzing the effectiveness of a proposed new technique, and aiding decision-making for the building operations and maintenance team.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Variable Nuclear Electricity with Base-Load Reactor, Closed Brayton Power Cycle and Firebrick Resistance-Heated Energy Storage (Fires)

Power cycle choices are determined by markets and available technologies. Two changes are occurring in the electricity sector. First, the world is beginning to move away from fossil fuels because of concerns about climate change. What replaces fossil fuels for variable electricity production? Second, there have been extraordinary technological advances in gas turbine technology. The changes in market requirements and technology suggest the need to reexamine nuclear power cycles. One option is to couple high-temperature base-load nuclear reactors to closed Brayton cycles (helium, nitrogen, etc.) with Firebrick Resistance-Heated Energy Storage (FIRES). The reactor operates at base-load but not the power cycle. When electricity prices are low, firebrick is electrically heated to high temperatures using base-load electricity and/or electricity from the grid. The gas turbine can use nuclear heat for base-load operation and produce added peak electricity by sending the compressed heated gas through hot firebrick after nuclear heating to further raise power cycle gas temperatures and power output from the turbine-creating a nuclear plant with a thermodynamic topping (NUTOP) cycle. If such cycles can be developed, they would increase plant revenue and enable a low-carbon electricity grid. Such cycles can be coupled to Fluoride-salt-cooled High-temperature Reactors (FHRs), molten salt reactors (MSRs), high-temperature gas-cooled reactors (HTGRs), sodium-cooled fast reactors (SFRs) and lead-cooled fast reactors (LFRs). We discuss (1) market changes, (2) previous work on Nuclear Air-Brayton Combined cycles (NACC) with base-load reactors and variable power to the electricity grid and (3) options for closed Brayton cycles with variable power while the reactor operates at base load. Market (customer) requirements ultimately drive selection of power cycles. A low-carbon electricity grid requires dispatchable nuclear electricity to replace the traditional role of fossil fuels in the electricity grid. While reactors can be operated at part load, this is expensive for a capital-intensive low-operating-cost technology. Brayton power cycles with FIRES have the potential capability to provide that variable electricity while the reactor operates at base load to (1) improve economics and (2) enable a zero-carbon electrical grid. Open Brayton cycles have been investigated. Work has now started on developing closed Brayton cycles with FIRES. Only limited work has been done to date has been done for closed cycles with FIRES. (authors)

42 ENGINEERING↗