Search NASA⌕ Search

SEARCH · Search NASA

Results for “passive interrogation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Experimental Evaluation of the Fast-Neutron Passive Collar (FNPC) Performance and Comparison with Scintillation Based Collars

This report describes a new method for the verification of fresh low enrichment uranium (LEU) fuel assemblies that can reduce International Atomic Energy Agency (IAEA) inspection time in the field and be completely independent of operator declared burnable poison content. The passive measurement makes unattended mode operation practical, and thus provides the potential for reducing inspector time in the field for future applications. The new simplified passive neutron measurement uses the 238 U spontaneous fission in LEU fresh fuel rods to self-interrogate the 235 U mass in the neighboring rods. The measured response increases linearly with the increase in the linear density (LD) of 235 U. The relatively high efficiency of the passive neutron detector (24%) provides good statistical precision (~ 2%) for the singles, doubles, and triples counting rates in the thermal-neutron mode. The three observables makes possible multiplicity analysis so that both the 235 U LD and the effective burnable poison content can be determined independent of the operator declarations. This closes the potential diversion path of miss-declaration the burnable poison content. This report presents the detector design, the as-built system, the detector parameter measurements, the calibration, and the assay uncertainty estimates. The calibration measurements were performed using the Los Alamos Laboratory mockup PWR fuel assembly. The measurements were made in both the fastneutron mode (with Cd/Gd metal liners) and the thermal-neutron mode (no Cd/Gd liners).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

New NDA Methods for Thorium Fuel Cycle Safeguards (Mid-Project Report)

This project is developing new Non-Destructive Assay (NDA) safeguards techniques for emergent thorium fuel cycles based on Neutron Resonance Transmission Analysis (NRTA), which can assay 233 U and 235 U when they are present together in a sample with potentially high gamma-ray backgrounds from fission products and 232 U. Existing passive techniques face large challenges for this task so new active interrogation methods are needed. This effort is also exploring how gamma-ray signatures can complement NRTA for enhanced assayed performance. This project leverages an NRTA system being developed at PNNL in collaboration with MIT, which uses a commercially available deuterium-tritium neutron generator at short standoff (~2 m). We aim to assess the feasibility and performance of these new NDA techniques for the range of relevant samples in thorium fuel cycles. Key advancements described in this mid-project report include NRTA system design for thorium safeguards measurements, characterization of 233 U oxide powder at PNNL, a survey of detector technologies suitable for NRTA in high gamma background environments, successful preliminary demonstration of a quantitative isotopic estimation algorithm, and first NRTA measurements of a thorium sample.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Smolt Monitoring at the Head of Lower Granite Reservoir and Lower Granite Dam, 2002 Annual Report.

This project monitored the daily passage of Chinook salmon Oncorhynchus tshawytscha, steelhead trout O. mykiss, and sockeye salmon smolts O. nerka during the 2002 spring out-migration at migrant traps on the Snake River and Salmon River. In 2002 fish management agencies released significant numbers of hatchery Chinook salmon and steelhead trout above Lower Granite Dam that were not marked with a fin clip or coded-wire tag. Generally, these fish were distinguishable from wild fish by the occurrence of fin erosion. Total annual hatchery Chinook salmon catch at the Snake River trap was 11.4 times greater in 2002 than in 2001. The wild Chinook catch was 15.5 times greater than the previous year. Hatchery steelhead trout catch was 2.9 times greater than in 2001. Wild steelhead trout catch was 2.8 times greater than the previous year. The Snake River trap collected 3,996 age-0 Chinook salmon of unknown rearing. During 2002, the Snake River trap captured 69 hatchery and 235 wild/natural sockeye salmon and 114 hatchery coho salmon O. kisutch. Differences in trap catch between years are due to fluctuations not only in smolt production, but also differences in trap efficiency and duration of trap operation associated with flow. The significant increase in catch in 2002 was due to a 3.1 fold increase in hatchery Chinook production and a more normal spring runoff. Trap operations began on March 10 and were terminated on June 7. The trap was out of operation for a total of four days due to mechanical failure or debris. Hatchery Chinook salmon catch at the Salmon River trap was 4.2 times greater and wild Chinook salmon catch was 2.4 times greater than in 2001. The hatchery steelhead trout collection in 2002 was 81% of the 2001 numbers. Wild steelhead trout collection in 2002 was 81% of the previous year's catch. Trap operations began on March 10 and were terminated on May 29 due to high flows. The trap was out of operation for four days due to high flow or debris. The increase in hatchery Chinook catch in 2002 was due to a 3.1 fold increase in hatchery production and differences in flow between years. Changes in hatchery and wild steelhead catch are probably due to differences in flow between years. Travel time (d) and migration rate (km/d) through Lower Granite Reservoir for PIT-tagged Chinook salmon and steelhead trout marked at the Snake River trap were affected by discharge. Statistical analysis of 2002 data detected a relation between migration rate and discharge for hatchery and wild Chinook salmon. For hatchery and wild Chinook salmon there was a 4.7-fold and a 3.7-fold increase in migration rate, respectively, between 50 and 100 kcfs. For steelhead trout tagged at the Snake River trap, statistical analysis detected a significant relation between migration rate and Lower Granite Reservoir inflow discharge. For hatchery and wild steelhead trout, there was a 1.8-fold and a 1.7-fold increase in migration rate, respectively, between 50 and 100 kcfs. Travel time and migration rate to Lower Granite Dam for fish marked at the Salmon River trap were calculated. Statistical analysis of the 2002 data detected a significant relation between migration rate and Lower Granite Reservoir inflow discharge for wild Chinook salmon and hatchery steelhead trout. The analysis was unable to detect a relation between migration rate and discharge for hatchery Chinook salmon. The lack of a detectable relation was probably a result of the migration rate data being spread over a very narrow range of discharge. Not enough data were available to perform the analysis for wild steelhead trout. Migration rate increased 4.3-fold for wild Chinook salmon and 2.2-fold for hatchery steelhead between 50 kcfs and 100 kcfs. Fish tagged with passive integrated transponder (PIT) tags at the Snake River trap were interrogated at four dams with PIT tag detection systems (Lower Granite, Little Goose, Lower Monumental, and McNary dams). Because of the addition of the fourth interrogation site (Lower Monumental) in 1993 and the installation of the Removable Spillway Weir at Lower Granite Dam in 2000, caution must be used in comparing cumulative interrogation data. Cumulative interrogations at the four dams for fish marked at the Snake River trap were 61% for hatchery Chinook, 68% for wild Chinook, 58% for hatchery steelhead, and 62% for wild steelhead. Cumulative interrogations at the four dams for fish marked at the Salmon River trap were 51% for hatchery Chinook, 59% for wild Chinook salmon, 45% for hatchery steelhead trout, and 54% for wild steelhead trout. Cumulative interrogations were significantly lower in 2002 than in previous years with similar flow.

13 HYDRO ENERGY↗

Combined Assay Systems for the Characterisation of Historical ILW at of the Dounreay Shaft and Silo-18140

In 1955 the Dounreay nuclear power development establishment was created on the northern coast of Scotland primarily to pursue the UK Government policy of developing Fast Breeder Reactor (FBR) technology. The site operated then by the United Kingdom Atomic Energy Authority (UKAEA) saw the development, test and operation of 3 nuclear reactors, two of them FBRs, alongside fabrication and reprocessing facilities for the FBR fuel elements. From the late 1950's until 1977 Intermediate Level radioactive Waste (ILW) generated on site was disposed of into a 65 m deep, 4.6 m diameter shaft. In January 1977, an explosion thought to be caused by hydrogen generated from sodium and potassium wastes reacting with water occurred in the upper part of the shaft, thus stopping any further waste disposal. A second ILW storage facility, the ILW-Silo, started operation in 1971 to deal with the increasing volume of intermediate level waste generated on site in the mid-1960's and continued receiving waste until 1998. The decommissioning of the Shaft and Silo facilities is a challenging engineering task due to the complexity and potential hazards linked with the retrieval and handling of historical waste. Following recovery it is intended to shred the majority of the waste and load it into 200-l assay drums. Sludges would be separated and solidified within a special annulus drum to make them suitable for assay. To support the decommissioning strategies put forward by Dounreay Site Restoration Limited (DSRL), Mirion Technologies Canberra UK Ltd have designed and completed the manufacture of a pair of combined non-destructive waste assay (NDA) systems. The two identical automated ILW counters are intended to provide a means to characterise the waste materials by performing active and passive neutron measurement as well as segmented high resolution gamma spectrometry (HRGS) of 200-l sacrificial waste drums. The active neutron technique is based on the Differential Die Away (DDA) technique using a pulsed Deuterium-Tritium neutron generator to interrogate fissile material present in the waste. The active neutron measurements support, as well as the passive neutron coincidence measurements, a matrix correction capability by use of an Add-a-Source mechanism. The publication will describe in broad lines the approach proposed by DSRL in the processing of the waste retrieved from both the Shaft and Silo facilities. It will also present a description of the overall design of the NDA counters, illustrating how the measurements to be performed will allow DSRL to safely characterise the retrieved waste materials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Resolution Scanning Configurations for the Canberra Tomographic Gamma Scanner - 17323

The Canberra Tomographic Gamma Scanner (TGS) is a Non-Destructive Assay (NDA) system that combines high resolution gamma ray spectroscopy (HRGS) with low-spatial-resolution imaging for the measurement of heterogeneous drummed waste with matrix densities in the range of 0 to 1 g/cc. The TGS methodology uses a two-pass scanning protocol; a 10-15 μCi {sup 152}Eu transmission source is used to interrogate density and composition of the matrix in the first pass, and passive gamma ray spectroscopy is used to collect emission spectra in the second, while the drum is rotated and translated to vary the view path. In standard implementations, the transmission and emission data are used to reconstruct three dimensional images of the matrix and activity distribution inside the drum on a 10x10x16 grid of discrete volume elements or 'voxels'. These images allow attenuation corrections to be calculated and applied on a view by view, and voxel by voxel basis, reducing the over- and under-correction biases obtained by assay techniques which assume homogeneous distributions of material. The most recent TGS system deployed by Canberra featured, among other new developments, the ability to perform higher resolution image re-construction, which may prove beneficial for the assay of more highly mixed matrices or oddly shaped assay items within a container. These additional scanning protocols reconstruct the image data into 14x14 and 20x20 voxel grids, using a smaller collimator aperture size. The hardware and software implementations of these higher resolution scans are discussed, and the calibration and initial evaluations of performance are presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distinguishing fissile uranium isotopes using an active well neutron coincidence counter

Proposed thorium-based nuclear fuel cycles are likely to require quantification and verification of 233 U within nuclear material. Because of their similar fission cross sections, active neutron nondestructive assay (NDA) systems may respond similarly to 233 U and 235 U. Traditional safeguards equipment has been optimized for 235 U and 238 U quantification associated with conventional uranium/plutonium fuel cycles and may not be directly applicable to 233 U quantification when mixed with other actinides. This work used models of the large volume active well coincidence counter (LV-AWCC) at Oak Ridge National Laboratory to evaluate the performance of this neutron NDA system to differentiate fissile uranium isotopes. The models were developed to simulate NDA system performance in response to a number of triangular radiation signature training device sources within the central cavity or well. This work predicted that the LV-AWCC can effectively differentiate 233 U from 235 U in certain modes of operation. In active mode, the LV-AWCC with the cadmium liner results in different doubles count rates between the fissile isotopes for a given fissile uranium mass. Without the cadmium liner, the uranium isotopes provide a statistically indistinguishable doubles count rate response for the fissile masses considered in this work (up to approximately 150 g). The cadmium liner serves to harden the neutron interrogation spectrum, which better exploits the notable difference in the 233 U and 235 U fission cross sections at approximately 1 eV. In passive mode, the two fissile isotopes exhibit different doubles and singles count rates regardless of liner presence because the passive source strength of 233 U is approximately 2 orders of magnitude stronger than that of 235 U due to the shorter half-life and correspondingly higher (α, n) yield. We conclude that using neutron interrogation in the LV-AWCC, two measurements are needed to quantify 233 U content in mixed uranium items. The first measurement is used to determine the total fissile uranium mass using a mode that cannot distinguish fissile isotopes (i.e., where a similar response is observed for both fissile uranium isotopes such as active doubles without cadmium or using a thermal neutron interrogation source). In conclusion, the second measurement is used to determine the 233 U content by using a differentiating technique (e.g., passive doubles, passive doubles to singles ratio, active doubles with cadmium).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rattling Nucleons: New Developments in Active Interrogation of Special Nuclear Material

Active interrogation is a vigorous area of research and development due to its promise of offering detection and characterization capabilities of special nuclear material in environments where passive detection fails. The primary value added by active methods is the capability to penetrate shielding - special nuclear material itself, incidental materials, or intentional shielding - and advocates hope that active interrogation will provide a solution to the problem of detecting shielded uranium, which is at present the greatest obstacle to interdiction efforts. The technique also provides a unique benefit for quantifying nuclear material in high background-radiation environments, an area important for nuclear material safeguards and material accountancy. Progress has been made in the field of active interrogation on several fronts, most notably in the arenas of source development, systems integration, and the integration and exploitation of multiple fission and non-fission signatures. But penetration of interrogating radiation often comes at a cost, not only in terms of finance and dose but also in terms of induced backgrounds, system complexity, and extended measurement times (including set up and acquisition). These costs make the calculus for deciding to implement active interrogation more subtle than may be apparent. The purpose of this review is thus to examine existing interrogation methods, compare and contrast their attributes and limitations, and identify missions where active interrogation may hold the most promise.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation and Demonstration of Intrusion Detection for Spent Fuel Storage Facilities

The IAEA recommends dual containment and surveillance (C/S) systems for difficult to access or difficult to measure spent fuel storage areas. However, many storage areas have limitations that prevent traditional secondary C/S systems, such as radiation levels too high for inspectors to apply individual Tamper Indicating Devices (TID) or have physical impedances to the use of TIDs. Recent developments in C/S technology include Laser Curtain for Containment (LCCT) technology implemented at Atucha-1 power plant in Argentina. The LCCT is a new approach to perimeter-wide C/S and the IAEA has granted provisional approval for its use as one of two required C/S systems. This proposal focuses on investigating and testing new and evolving completely passive (or ultra-low power) tamper indicating systems that will provide backup C/S to the LCCT even during power outages. An investigation of Commercial Off The Shelf (COTS) technology will be conducted to identify readily available options. Optically Stimulated Luminescence (OSL) fibers will also be investigated. OSL fibers are a passive technology that can measure radiation dose by knocking an electron into a metastable state where it remains until the fiber is interrogated with light. The goal of this project would be to investigate COTS technologies that can be used in low or no power scenarios for radiation detection as well as test and evaluate OSL technology, which can operate passively in no power scenarios. Limitations for each technology will be determined and documented in an effort to determine the best technology for spent fuel storage monitoring.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Smolt Monitoring at the Head of Lower Granite Reservoir and Lower Granite Dam, 2003 Annual Report.

This project monitored the daily passage of Chinook salmon Oncorhynchus tshawytscha, steelhead trout O. mykiss, and sockeye salmon O. nerka smolts during the 2003 spring out-migration at migrant traps on the Snake River and Salmon River. In 2003 fish management agencies released significant numbers of hatchery Chinook salmon and steelhead trout above Lower Granite Dam that were not marked with a fin clip or coded-wire tag. Generally, these fish were distinguishable from wild fish by the occurrence of fin erosion. Total annual hatchery Chinook salmon catch at the Snake River trap was 2.1 times less in 2003 than in 2002. The wild Chinook catch was 1.1 times less than the previous year. Hatchery steelhead trout catch was 1.7 times less than in 2002. Wild steelhead trout catch was 2.1 times less than the previous year. The Snake River trap collected 579 age-0 Chinook salmon of unknown rearing. During 2003, the Snake River trap captured five hatchery and 13 wild/natural sockeye salmon and 36 coho salmon O. kisutch of unknown rearing. Differences in trap catch between years are due to fluctuations not only in smolt production, but also differences in trap efficiency and duration of trap operation associated with flow. The significant differences in catch between 2003 and the previous year were due mainly to low flows during much of the trapping season and then very high flows at the end of the season, which terminated the trapping season 12 days earlier than in 2002. Trap operations began on March 9 and were terminated on May 27. The trap was out of operation for a total of zero days due to mechanical failure or debris. Hatchery Chinook salmon catch at the Salmon River trap was 16.8% less and wild Chinook salmon catch was 1.7 times greater than in 2002. The hatchery steelhead trout collection in 2003 was 5.6% less than in 2002. Wild steelhead trout collection was 19.2% less than the previous year. Trap operations began on March 9 and were terminated on May 24 due to high flows. There were zero days when the trap was out of operation due to high flow or debris. The decrease in hatchery Chinook catch in 2003 was partially due to differences in flow between years because there was a 5.9% increase in hatchery production in the Salmon River drainage in 2003. The decrease in hatchery steelhead catch may be partially due to a 13% decrease in hatchery production in the Salmon River drainage in 2003. Travel time (d) and migration rate (km/d) through Lower Granite Reservoir for PIT-tagged Chinook salmon and steelhead trout marked at the Snake River trap were affected by discharge. Statistical analysis of 2003 data detected a relation between migration rate and discharge for wild Chinook salmon but was unable to detect a relation for hatchery Chinook. The inability to detect a migration rate discharge relation for hatchery Chinook was probably caused by age 0 fall Chinook being mixed in with the age 1 Chinook. Age 0 fall Chinook migrate much slower than age 1 Chinook, which would confuse the ability to detect the migration rate discharge relation. For wild Chinook salmon there was a 1.4-fold increase in migration rate, respectively, between 50 and 100 kcfs. For steelhead trout tagged at the Snake River trap, statistical analysis detected a significant relation between migration rate and Lower Granite Reservoir inflow discharge. For hatchery and wild steelhead trout, there was a 1.7-fold and a 1.9-fold increase in migration rate, respectively, between 50 and 100 kcfs. Travel time and migration rate to Lower Granite Dam for fish marked at the Salmon River trap were calculated. Statistical analysis of the 2003 data detected a significant relation between migration rate and Lower Granite Reservoir inflow discharge for hatchery Chinook salmon, wild Chinook salmon and hatchery steelhead trout. Not enough data were available to perform the analysis for wild steelhead trout. Migration rate increased 14-fold for hatchery Chinook salmon, 8.3-fold for wild Chinook salmon and 2.4-fold for hatchery steelhead as discharge increased between 50 kcfs and 100 kcfs. Fish tagged with passive integrated transponder (PIT) tags at the Snake River and Salmon River traps were interrogated at four dams with PIT tag detection systems (Lower Granite, Little Goose, Lower Monumental, and McNary dams). Because of the addition of the fourth interrogation site (Lower Monumental) in 1993 and the installation of the Removable Spillway Weir at Lower Granite Dam in 2001, caution must be used in comparing cumulative interrogation data. Cumulative interrogations at the four dams for fish marked at the Snake River trap were 65% for hatchery Chinook, 72% for wild Chinook, 66% for hatchery steelhead, and 67% for wild steelhead. Cumulative interrogations at the four dams for fish marked at the Salmon River trap were 48% for hatchery Chinook, 61% for wild Chinook salmon, 57% for hatchery steelhead trout, and 56% for wild steelhead trout.

13 HYDRO ENERGY↗

Smolt Monitoring at the Head of Lower Granite Reservoir and Lower Granite Dam, 2004 Annual Report.

This project monitored the daily passage of Chinook salmon Oncorhynchus tshawytscha, steelhead trout O. mykiss, and sockeye salmon O. nerka smolts during the 2004 spring out-migration at migrant traps on the Snake River and Salmon River. In 2004 fish management agencies released significant numbers of hatchery Chinook salmon and steelhead trout above Lower Granite Dam that were not marked with a fin clip or coded-wire tag. Generally, these fish were distinguishable from wild fish by the occurrence of fin erosion. Total annual hatchery Chinook salmon catch at the Snake River trap was 1.1 times greater in 2004 than in 2003. The wild Chinook catch was 1.1 times greater than the previous year. Hatchery steelhead trout catch was 1.2 times greater than in 2003. Wild steelhead trout catch was 1.6 times greater than the previous year. The Snake River trap collected 978 age-0 Chinook salmon of unknown rearing. During 2004, the Snake River trap captured 23 hatchery and 18 wild/natural sockeye salmon and 60 coho salmon O. kisutch of unknown rearing. Differences in trap catch between years are due to fluctuations not only in smolt production, but also differences in trap efficiency and duration of trap operation associated with flow. Trap operations began on March 7 and were terminated on June 4. The trap was out of operation for a total of zero days due to mechanical failure or debris. Hatchery Chinook salmon catch at the Salmon River trap was 10.8% less and wild Chinook salmon catch was 19.0% less than in 2003. The hatchery steelhead trout collection in 2004 was 20.0% less and wild steelhead trout collection was 22.3% less than the previous year. Trap operations began on March 7 and were terminated on May 28 due to high flows. There were two days when the trap was taken out of service because wild Chinook catch was very low, hatchery Chinook catch was very high, and the weekly quota of PIT tagged hatchery Chinook had been met. Travel time (d) and migration rate (km/d) through Lower Granite Reservoir for PIT-tagged Chinook salmon and steelhead trout marked at the Snake River trap were affected by discharge. Statistical analysis of 2004 data detected a relation between migration rate and discharge for wild Chinook salmon but was unable to detect a relation for hatchery Chinook. The inability to detect a migration rate discharge relation for hatchery Chinook salmon was caused by age-0 fall Chinook being mixed in with the age 1 Chinook. Age-0 fall Chinook migrate much slower than age-1 Chinook, which would confuse the ability to detect the migration rate discharge relation. When several groups, which consisted of significant numbers of age-0 Chinook salmon, were removed from the analysis a relation was detected. For hatchery and wild Chinook salmon there was a 2.8-fold and a 2.4-fold increase in migration rate, respectively, between 50 and 100 kcfs. For steelhead trout tagged at the Snake River trap, statistical analysis detected a significant relation between migration rate and Lower Granite Reservoir inflow discharge. For hatchery and wild steelhead trout, there was a 2.3-fold and a 2.0-fold increase in migration rate, respectively, between 50 and 100 kcfs. Travel time and migration rate to Lower Granite Dam for fish marked at the Salmon River trap were calculated. Statistical analysis of the 2004 data detected a significant relation between migration rate and Lower Granite Reservoir inflow discharge for hatchery Chinook salmon, wild Chinook salmon and hatchery steelhead trout. Not enough data were available to perform the analysis for wild steelhead trout. Migration rate increased 7.0-fold for hatchery Chinook salmon, 4.7-fold for wild Chinook salmon and 3.8-fold for hatchery steelhead as discharge increased between 50 kcfs and 100 kcfs. Fish tagged with passive integrated transponder (PIT) tags at the Snake River and Salmon River traps were interrogated at four dams with PIT tag detection systems (Lower Granite, Little Goose, Lower Monumental, and McNary dams). Because of the addition of the fourth interrogation site (Lower Monumental) in 1993 and the installation of the Removable Spillway Weir at Lower Granite Dam in 2001, caution must be used in comparing cumulative interrogation data. Cumulative interrogations at the four dams for fish marked at the Snake River trap were 82% for hatchery Chinook, 77% for wild Chinook, 90% for hatchery steelhead, and 90% for wild steelhead. Cumulative interrogations at the four dams for fish marked at the Salmon River trap were 68% for hatchery Chinook, 70% for wild Chinook salmon, 80% for hatchery steelhead trout, and 79% for wild steelhead trout.

13 HYDRO ENERGY↗

WIRE-21 Experiment Irradiation Conditions and In-Situ Data Collection

This report summarizes the in situ data collected during three cycles of irradiation (~75 days) of the Wireless Instrumented Removable Beryllium Experiment 2021 (WIRE-21) in the removable beryllium (RB) positions of the High Flux Isotope Reactor (HFIR). The experiment was designed primarily to evaluate the effects of high neutron flux and fluence on the performance of wireless temperature and pressure sensors being developed by Westinghouse Electric Company (WEC). WEC’s sensors could provide critical data regarding the evolution of centerline temperatures and pressurization due to fission gas release during fuel operation in light-water reactors (LWRs) or various advanced reactor applications. In addition to WEC’s wireless sensors, many other sensors were interrogated, including thermocouples, self-powered neutron detectors (SPNDs), distributed fiber optic temperature sensors, and passive neutron flux wires and silicon carbide thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated Weight-Window Generation for Threat Detection Applications Using ADVANTG

Deterministic transport codes have been used for some time to generate weight-window parameters that can improve the efficiency of Monte Carlo simulations. As the use of this hybrid computational technique is becoming more widespread, the scope of applications in which it is being applied is expanding. An active source of new applications is the field of homeland security--particularly the detection of nuclear material threats. For these problems, automated hybrid methods offer an efficient alternative to trial-and-error variance reduction techniques (e.g., geometry splitting or the stochastic weight window generator). The ADVANTG code has been developed to automate the generation of weight-window parameters for MCNP using the Consistent Adjoint Driven Importance Sampling method and employs the TORT or Denovo 3-D discrete ordinates codes to generate importance maps. In this paper, we describe the application of ADVANTG to a set of threat-detection simulations. We present numerical results for an 'active-interrogation' problem in which a standard cargo container is irradiated by a deuterium-tritium fusion neutron generator. We also present results for two passive detection problems in which a cargo container holding a shielded neutron or gamma source is placed near a portal monitor. For the passive detection problems, ADVANTG obtains an O(10{sup 4}) speedup and, for a detailed gamma spectrum tally, an average O(10{sup 2}) speedup relative to implicit-capture-only simulations, including the deterministic calculation time. For the active-interrogation problem, an O(10{sup 4}) speedup is obtained when compared to a simulation with angular source biasing and crude geometry splitting.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Passive IFF: Autonomous Nonintrusive Rapid Identification of Friendly Assets

A proposed optoelectronic instrument would identify targets rapidly, without need to radiate an interrogating signal, apply identifying marks to the targets, or equip the targets with transponders. The instrument was conceived as an identification, friend or foe (IFF) system in a battlefield setting, where it would be part of a targeting system for weapons, by providing rapid identification for aimed weapons to help in deciding whether and when to trigger them. The instrument could also be adapted to law-enforcement and industrial applications in which it is necessary to rapidly identify objects in view. The instrument would comprise mainly an optical correlator and a neural processor (see figure). The inherent parallel-processing speed and capability of the optical correlator would be exploited to obtain rapid identification of a set of probable targets within a scene of interest and to define regions within the scene for the neural processor to analyze. The neural processor would then concentrate on each region selected by the optical correlator in an effort to identify the target. Depending on whether or not a target was recognized by comparison of its image data with data in an internal database on which the neural processor was trained, the processor would generate an identifying signal (typically, friend or foe ). The time taken for this identification process would be less than the time needed by a human or robotic gunner to acquire a view of, and aim at, a target. An optical correlator that has been under development for several years and that has been demonstrated to be capable of tracking a cruise missile might be considered a prototype of the optical correlator in the proposed IFF instrument. This optical correlator features a 512-by-512-pixel input image frame and operates at an input frame rate of 60 Hz. It includes a spatial light modulator (SLM) for video-to-optical image conversion, a pair of precise lenses to effect Fourier transforms, a filter SLM for digital-to-optical correlation-filter data conversion, and a charge-coupled device (CCD) for detection of correlation peaks. In operation, the input scene grabbed by a video sensor is streamed into the input SLM. Precomputed correlation-filter data files representative of known targets are then downloaded and sequenced into the filter SLM at a rate of 1,000 Hz. When there occurs a match between the input target data and one of the known-target data files, the CCD detects a correlation peak at the location of the target. Distortion- invariant correlation filters from a bank of such filters are then sequenced through the optical correlator for each input frame. The net result is the rapid preliminary recognition of one or a few targets.

Moynihan, Philip↗

Influence of modulation frequency in rubidium cell frequency standards

The error signal which is used to control the frequency of the quartz crystal oscillator of a passive rubidium cell frequency standard is considered. The value of the slope of this signal, for an interrogation frequency close to the atomic transition frequency is calculated and measured for various phase (or frequency) modulation waveforms, and for several values of the modulation frequency. A theoretical analysis is made using a model which applies to a system in which the optical pumping rate, the relaxation rates and the RF field are homogeneous. Results are given for sine-wave phase modulation, square-wave frequency modulation and square-wave phase modulation. The influence of the modulation frequency on the slope of the error signal is specified. It is shown that the modulation frequency can be chosen as large as twice the non-saturated full-width at half-maximum without a drastic loss of the sensitivity to an offset of the interrogation frequency from center line, provided that the power saturation factor and the amplitude of modulation are properly adjusted.

Audoin, C.↗

Near-Field Passive Wireless Sensor for High-Temperature Metal Corrosion Monitoring

This work focuses on the fabrication and evaluation of a passive wireless sensor for the monitoring of the temperature and corrosion of a metal material at high temperatures. An inductor–capacitor (LC) resonator sensor was fabricated through the screen printing of Ag-based inks on dense polycrystalline Al 2 O 3 substrates. The LC design was modeled using the ANSYS HFSS modeling package, with the LC passive wireless sensors operating at frequencies from 70 to 100 MHz. The wireless response of the LC was interrogated and received by a radio frequency signal generator and spectrum analyzer at temperatures from 50 to 800 °C in real time. The corrosion kinetics of the Cu 110 was characterized through thermogravimetric (TGA) analysis and microscopy images, and the oxide thickness growth was then correlated to the wireless sensor signal under isothermal conditions at 800 °C. The results showed that the wireless signal was consistent with the corrosion kinetics and temperature, indicating that these two characteristics can be further deconvoluted in the future. In addition, the sensor also showed a magnitude- and frequency-dependent response to crack/spallation events in the oxide corrosion layer, permitting the in situ wireless identification of these catastrophic events on the metal surface at high temperatures.

36 MATERIALS SCIENCE↗

Determination of total Pu content in a Spent Fuel Assembly by Measuring Passive Neutron Count rate and Multiplication with the Differential Die-Away Instrument

A key objective of the Next Generation Safeguards Initiative (NGSI) is to evaluate and develop non-destructive assay (NDA) techniques to determine the elemental plutonium content in a commercial-grade nuclear spent fuel assembly (SFA) [1]. Within this framework, we investigate by simulation a novel analytical approach based on combined information from passive measurement of the total neutron count rate of a SFA and its multiplication determined by the active interrogation using an instrument based on a Differential Die-Away technique (DDA). We use detailed MCNPX simulations across an extensive set of SFA characteristics to establish the approach and demonstrate its robustness. It is predicted that Pu content can be determined by the proposed method to a few %.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Extended Range Passive Wireless Tag System and Method

A passive wireless tag assembly comprises a plurality of antennas and transmission lines interconnected with circuitry and constructed and arranged in a Van Atta array or configuration to reflect an interrogator signal in the direction from where it came. The circuitry may comprise at least one surface acoustic wave (SAW)-based circuit that functions as a signal reflector and is operatively connected with an information circuit. In another embodiment, at least one delay circuit and/or at least one passive modulation circuit(s) are utilized. In yet another embodiment, antennas connected to SAW-based devices are mounted to at least one of the orthogonal surfaces of a corner reflector.

Fink, Patrick W.↗