Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Real-time catheter tracking for high-dose-rate prostate brachytherapy using an electromagnetic 3D-guidance device: A preliminary performance study

Purpose: In order to increase the accuracy and speed of catheter reconstruction in a high-dose-rate (HDR) prostate implant procedure, an automatic tracking system has been developed using an electromagnetic (EM) device (trakSTAR, Ascension Technology, VT). The performance of the system, including the accuracy and noise level with various tracking parameters and conditions, were investigated. Methods: A direct current (dc) EM transmitter (midrange model) and a sensor with diameter of 1.3 mm (Model 130) were used in the trakSTAR system for tracking catheter position during HDR prostate brachytherapy. Localization accuracy was assessed under both static and dynamic analyses conditions. For the static analysis, a calibration phantom was used to investigate error dependency on operating room (OR) table height (bottom vs midposition vs top), sensor position (distal tip of catheter vs connector end of catheter), direction [left-right (LR) vs anterior-posterior (AP) vs superior-inferior (SI)], sampling frequency (40 vs 80 vs 120 Hz), and interference from OR equipment (present vs absent). The mean and standard deviation of the localization offset in each direction and the corresponding error vectors were calculated. For dynamic analysis, the paths of five straight catheters were tracked to study the effects of directions, sampling frequency, and interference of EM field. Statistical analysis was conducted to compare the results in different configurations. Results: When interference was present in the static analysis, the error vectors were significantly higher at the top table position (3.3 {+-} 1.3 vs 1.8 {+-} 0.9 mm at bottom and 1.7 {+-} 1.0 mm at middle, p < 0.001), at catheter end position (3.1 {+-} 1.1 vs 1.4 {+-} 0.7 mm at the tip position, p < 0.001), and at 40 Hz sampling frequency (2.6 {+-} 1.1 vs 2.4 {+-} 1.5 mm at 80 Hz and 1.8 {+-} 1.1 at 160 Hz, p < 0.001). So did the mean offset errors in the LR direction (-1.7 {+-} 1.4 vs 0.4 {+-} 0.5 mm in AP and 0.8 {+-} 0.8 mm in SI directions, p < 0.001). The error vectors were significantly higher with surrounding interference (2.2 {+-} 1.3 mm) vs without interference (1.0 {+-} 0.7 mm, p < 0.001). An accuracy of 1.6 {+-} 0.2 mm can be reached when using optimum configuration (160 Hz at middle table position). When interference was present in the dynamic tracking, the mean tracking errors in LR direction (1.4 {+-} 0.5 mm) was significantly higher than that in AP direction (0.3 {+-} 0.2 mm, p < 0.001). So did the mean vector errors at 40 Hz (2.1 {+-} 0.2 mm vs 1.3 {+-} 0.2 mm at 80 Hz and 0.9 {+-} 0.2 mm at 160 Hz, p < 0.05). However, when interference was absent, they were comparable in the both directions and at all sampling frequencies. An accuracy of 0.9 {+-} 0.2 mm was obtained for the dynamic tracking when using optimum configuration. Conclusions: The performance of an EM tracking system depends highly on the system configuration and surrounding environment. The accuracy of EM tracking for catheter reconstruction in a prostate HDR brachytherapy procedure can be improved by reducing interference from surrounding equipment, decreasing distance from transmitter to tracking area, and choosing appropriated sampling frequency. A calibration scheme is needed to further reduce the tracking error when the interference is high.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Probability friends-of-friends (PFOF) group finder: Performance study and observational data applications on photometric surveys

In tandem with observational data sets, we utilize realistic mock catalogs, based on a semi-analytic galaxy formation model, constructed specifically for Pan-STARRS1 Medium Deep Surveys to assess the performance of the Probability Friends-of-Friends (PFOF) group finder, and aim to develop a grouping optimization method applicable to surveys like Pan-STARRS1. Producing mock PFOF group catalogs under a variety of photometric redshift accuracies (σ{sub Δz/(1+z{sub s)}}), we find that catalog purities and completenesses from 'good' (σ{sub Δz/(1+z{sub s)}}∼ 0.01) to 'poor' (σ{sub Δz/(1+z{sub s)}}∼ 0.07) photo-zs gradually degrade from 77% and 70% to 52% and 47%, respectively. A 'subset optimization' approach is developed by using spectroscopic-redshift group data from the target field to train the group finder for application to that field and demonstrated using zCOSMOS groups for PFOF searches within PS1 Medium Deep Field04 (PS1MD04) and DEEP2 EGS groups in PS1MD07. With four data sets spanning the photo-z accuracy range from 0.01 to 0.06, we find purities and completenesses agree with their mock analogs. Further tests are performed via matches to X-ray clusters. We find PFOF groups match ∼85% of X-ray clusters identified in COSMOS and PS1MD04, lending additional support to the reliability of the detection algorithm. In the end, we demonstrate, by separating red and blue group galaxies in the EGS and PS1MD07 group catalogs, that the algorithm is not biased with respect to specifically recovering galaxies by color. The analyses suggest the PFOF algorithm shows great promise as a reliable group finder for photometric galaxy surveys of varying depth and coverage.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance studies on solar collector with grooved absorber tube configuration using aqueous ZnO–ethylene glycol nanofluids

Solar flat plate collector (SFPC) is regarded as one of the best renewable energy devices to acquire hot water for domestic usage. Though its theoretical efficiency is projected at higher scale, its conversion efficiency is observed to be low due to various collector losses. Hence, to achieve improved performance of collector different techniques for heat transfer augmentation in circular pipes can be adopted. Among passive and active techniques available, passive is preferred over active due to economics and saving in exergy. Hence, in the present study absorber tube configuration is modified with internal grooves in the collector setup to enhance the rate of heat transfer. Also, fluids dispersed with metal oxide particles provide an increase in thermal conductivity such that ZnO-based aqueous EG mixture nanofluid is used as working medium to analyze the performance of collector setup. Also, the change in heat transfer rate and temperature profile of grooved tubes under forced laminar conditions for different working fluids are compared and reported.

14 SOLAR ENERGY↗

Structured light scanning artifact-based performance study

Structured light scanning is used to create a digital twin of a manufactured part, where features are extracted to determine if the part meets the designer’s intent and required tolerances. This paper describes repeatability and reproducibility analyses for a commercially-available structured light scanning system and measurement artifact. The repeatability study used five repeated scans at 15 measurement positions. Repeatability was assessed by randomly selecting one of the five scans at each of the 15 positions and creating a part mesh. This process was performed 50 times and the statistics for the dimension variations were calculated to isolate the scanning effects only. The same sequence was then performed for 10 of the 15 positions and five of the 15 positions to evaluate the repeatability sensitivity to the number of measurement positions. Reproducibility was assessed by selecting 15 positions to create a mesh and repeating the 15-position measurement sequence 10 times using different positions for each mesh construction. The statistics for the dimension variations were then calculated. This incorporated the effects of both scanning and the position and orientation of the part relative to the scanner. This sequence was repeated for 10-position and five-position scans to evaluate the corresponding sensitivity. Finally, the artifact dimensions from structured light scanning were compared to coordinate measuring machine measurements of the same features.

42 ENGINEERING↗

NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system

Purpose: The GE SIGNA PET/MR is a new whole body integrated time-of-flight (ToF)-PET/MR scanner from GE Healthcare. The system is capable of simultaneous PET and MR image acquisition with sub-400 ps coincidence time resolution. Simultaneous PET/MR holds great potential as a method of interrogating molecular, functional, and anatomical parameters in clinical disease in one study. Despite the complementary imaging capabilities of PET and MRI, their respective hardware tends to be incompatible due to mutual interference. In this work, the GE SIGNA PET/MR is evaluated in terms of PET performance and the potential effects of interference from MRI operation. Methods: The NEMA NU 2-2012 protocol was followed to measure PET performance parameters including spatial resolution, noise equivalent count rate, sensitivity, accuracy, and image quality. Each of these tests was performed both with the MR subsystem idle and with continuous MR pulsing for the duration of the PET data acquisition. Most measurements were repeated at three separate test sites where the system is installed. Results: The scanner has achieved an average of 4.4, 4.1, and 5.3 mm full width at half maximum radial, tangential, and axial spatial resolutions, respectively, at 1 cm from the transaxial FOV center. The peak noise equivalent count rate (NECR) of 218 kcps and a scatter fraction of 43.6% are reached at an activity concentration of 17.8 kBq/ml. Sensitivity at the center position is 23.3 cps/kBq. The maximum relative slice count rate error below peak NECR was 3.3%, and the residual error from attenuation and scatter corrections was 3.6%. Continuous MR pulsing had either no effect or a minor effect on each measurement. Conclusions: Performance measurements of the ToF-PET whole body GE SIGNA PET/MR system indicate that it is a promising new simultaneous imaging platform.

60 APPLIED LIFE SCIENCES↗

Performance study of polycrystalline CVD diamond detectors for fast neutron monitoring

Diamond detectors using polycrystalline CVD diamond substrates of thickness 300μm and 100μm were fabricated for fast neutron monitoring application.. The characterization of detectors was carried out using various tests such as leakage current, capacitance and alpha particle response. The performance of detectors was evaluated for fast neutrons at different neutron yields. The results presented in this work demonstrate that the diamond detectors will be suitable for monitoring fast neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chimera Events for Performance Studies of the MicroBooNE Deep Learning-based Low Energy Excess Search

MicroBooNE is a short baseline neutrino oscillation experiment based at Fermilab that employs Liquid Argon Time Projection Chamber (LArTPC) technology. One of its target measurements is to investigate the nature of the excess of low energy electron-like events observed by MiniBooNE. This measurement will require an excellent understanding of systematic uncertainties, obtained through testing the performance of reconstruction algorithms on samples with known properties. However, using exclusively Monte Carlo events for this task is limited by how well the discrepancies between simulation and data are understood. An alternative is to test against samples of “chimera” events, which are made up of separate single-particle components from data that are combined to create neutrino-like events. These chimera events can be used to help quantify systematic uncertainties. This note covers the performance and status of creating and using chimera events that match a target neutrino topology in MicroBooNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam test performance studies of CMS Phase-2 Outer Tracker module prototypes

A new tracking detector will be installed as part of thePhase-2 upgrade of the CMS detector for the high-luminosity LHC era.This tracking detector includes the Inner Tracker, equipped withsilicon pixel sensor modules, and the Outer Tracker, consisting ofmodules with two parallel stacked silicon sensors. The Outer Trackerfront-end ASICs will be able to correlate hits from chargedparticles in these two sensors to perform on-module discriminationof transverse momenta (p$_{T}$). The p$_{T}$information is generated at a frequency of 40 MHz and will be usedin the Level-1 trigger decision of CMS. Prototypes of theso-called 2S modules were tested at the Test Beam Facility at DESYHamburg between 2019 and 2020. These modules use the finalfront-end ASIC, the CMS Binary Chip (CBC), and for the firsttime the Concentrator Integrated Circuit (CIC), optical readoutand on-module power conversion. In total, seven modules were tested,one of which was assembled with sensors irradiated with protons. Animportant aspect was to show that it is possible to read out modulessynchronously. A cluster hit efficiency of about 99.75 % wasachieved for all modules. The CBC p$_{T}$ discriminationmechanism has been verified to work together with the CIC andoptical readout. The measured module performance meets therequirements for operation in the upgraded CMS tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Performance Study of Quantum ESPRESSO’s PWscf Code on Multi-core and GPU Systems

We describe the porting of PWscf (Plane-Wave Self Consistent Field), a key component of the Quantum ESPRESSO open-source suite of codes for materials modeling, to GPU systems using CUDA Fortran. Kernel loop directives (CUF kernels) have been extensively used in order to have a single source code for both CPU and GPU implementations. The results of the GPU version have been carefully validated and the performance of the code on several GPU systems (both x86 and POWER8 based) has been compared with traditional Intel multi-core (CPU only) systems. This current GPU version can reduce the time-to-solution by an average factor of 2–3 running two different input cases widely used as benchmarks on small and large high performance computing systems.

CUDA Fortran↗

Kinetic and Performance Studies of the Regeneration Phase of Model Pt/Ba/Rh NOx Traps for Design and Optimization

In this project a combined experimental and theoretical approach was taken to advance our understanding of lean NOx trap (LNT) technology. Fundamental kinetics studies were carried out of model LNT catalysts containing variable loadings of precious metals (Pt, Rh), and storage components (BaO, CeO{sub 2}). The Temporal Analysis of Products (TAP) reactor provided transient data under well-characterized conditions for both powder and monolith catalysts, enabling the identification of key reaction pathways and estimation of the corresponding kinetic parameters. The performance of model NOx storage and reduction (NSR) monolith catalysts were evaluated in a bench scale NOx trap using synthetic exhaust, with attention placed on the effect of the pulse timing and composition on the instantaneous and cycle-averaged product distributions. From these experiments we formulated a global model that predicts the main spatio-temporal features of the LNT and a mechanistic-based microkinetic models that incorporates a detailed understanding of the chemistry and predicts more detailed selectivity features of the LNT. The NOx trap models were used to determine its ability to simulate bench-scale data and ultimately to evaluate alternative LNT designs and operating strategies. The four-year project led to the training of several doctoral students and the dissemination of the findings as 47 presentations in conferences, catalysis societies, and academic departments as well 23 manuscripts in peer-reviewed journals. A condensed review of NOx storage and reduction was published in an encyclopedia of technology.

54 ENVIRONMENTAL SCIENCES↗

Electrochemical and rate performance study of high-voltage lithium-richcomposition: Li1.2Mn0.525Ni0.175Co0.1O2

We report electrochemical studies of high voltage cathodes composed of lithium rich layeredlayered material having the nominal composition Li1.2Mn0.525Ni0.175Co0.1O2, or equivalently 0.6Li[Li1/3Mn2/3]O2 0.4Li[Mn0.3Ni0.45Co0.25]O2. These aspects were investigated by cyclic voltammetry studies in conjunction with electrochemical impedance spectroscopy measurements to understand the redox reactions involving multiple transition metals and their capacity contribution at higher voltages, up to 4.9 V. Further, cathodes with 1.5 wt.% carbon nanofibers added to the Li1.2Mn0.525Ni0.175Co0.1O2 composite electrode showed stable reversible capacities of about 280 mAh g 1 when cycled to 4.9 V for more than 100 cycles, and almost a factor of two improvements in the rate performance compared to the electrode composition prepared using conventional composition (7.5% carbon black and 7.5% binder).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MixSim : An R Package for Simulating Data to Study Performance of Clustering Algorithms

The R package MixSim is a new tool that allows simulating mixtures of Gaussian distributions with different levels of overlap between mixture components. Pairwise overlap, defined as a sum of two misclassification probabilities, measures the degree of interaction between components and can be readily employed to control the clustering complexity of datasets simulated from mixtures. These datasets can then be used for systematic performance investigation of clustering and finite mixture modeling algorithms. Among other capabilities of MixSim, there are computing the exact overlap for Gaussian mixtures, simulating Gaussian and non-Gaussian data, simulating outliers and noise variables, calculating various measures of agreement between two partitionings, and constructing parallel distribution plots for the graphical display of finite mixture models. All features of the package are illustrated in great detail. The utility of the package is highlighted through a small comparison study of several popular clustering algorithms.

97 MATHEMATICS AND COMPUTING↗

Degradation & Performance Studies of ALD-Stabilized Nano-Composite SOFC Cathodes

This work showed, definitively, for the first time, that zirconia Atomic Layer Deposited (ALD) overcoats improve the stability of Solid Oxide Fuel Cell (SOFC) cathodes by chemically gettering interfacial Sr that has segregated out of lanthanum strontium cobalt iron oxide (LSCF). The optimum ALD ZrO 2 overcoat thickness was found to be ≥5 nm and <10 nm. Gadolinium doped ceria (GDC) pre-infiltration was also shown, for the first time, to improve SOFC cathode stability through the chemical getting of Sr at the LSCF-backbone and LSCF-gas interfaces. Due to the fact that it can be performed easily in air on large-area electrodes, GDC pre-infiltration is likely more commercially viable than ALD ZrO 2 overcoating as an interfacial Sr gettering technique. Combining ZrO 2 overcoating with GDC pre-infiltration was not successful because the GDC nano-particles gettered the ZrO 2 overcoat instead of the interfacial Sr.

30 DIRECT ENERGY CONVERSION↗

Performance study of single undoped CsI crystals for the Mu2e experiment

The Mu2e experiment at Fermilab aims to measure the neutrinoless muon-to-electron conversion, which is a charged-lepton flavor-violating process. The goal of the experiment is to reach a single event sensitivity of 2.5 × 10 -17 , to set an upper limit on the muon conversion rate at 6.7 × 10 -17 in a three-year run. For this purpose, the Mu2e detector is designed to identify electrons from muon conversion and reduce the background to a negligible level. It consists of a low-mass straw tracker and a pure CsI crystal calorimeter. In this paper, the performance of undoped CsI single crystal is reported. Crystals from many vendors have been characterized by determining their Light Yield (LY) and Longitudinal Response Uniformity (LRU), when read with a UV extended PMT, and their time resolution when coupled to a silicon photomultiplier. The crystals show a LY of ~100 photoelectrons per MeV when wrapped with Tyvek and coupled to the PMT without optical grease. The LRU is well represented by a linear slope that is on average 0.6%/cm. Both measurements have been performed using a 22 Na source. The timing performance has been evaluated exploiting cosmic rays, with MPPC readout. A timing resolution lower than 400 ps has been achieved (at ~20 MeV, which is the energy released by a minimum ionizing particle in the crystal).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PERFORMANCE STUDY OF LIQUID NITROGEN THERMO-SIPHON COOLING LOOP

A RF-superconducting linear accelerator (LINAC) booster for the existing 15 UD Pelletron accelerator is presently under construction at Inter-University Accelerator Centre in New Delhi, India. The LINAC will make use of superconducting niobium quarter-wave resonators (QWR) as the accelerating element, and will consist of three accelerating cryomodules. A gravity-assisted (thermo-siphon) flow scheme with liquid nitrogen has been proposed to cool the thermal radiation shields of the LINAC cryomodules. A small test rig of the thermo-siphon loop has been developed to simulate and investigate the chosen aspects of the proposed configuration. The experimental work has been focused on the thermal performances of the specially designed copper clamps and optimization of the system engineering parameters. The paper presents the results of the thermo-siphon measurements and the qualitative description of the investigated phenomena.

42 ENGINEERING↗

International fuel performance study of fresh fuel experiments for PCMI effects during RIA experiments

This paper presents the results of High-burnup Experiments for Reactivity-initiated Accident (HERA) Modeling & Simulation (M&S) exercise. The HERA project under the Nuclear Energy Agency (NEA) Second Framework for Irradiation Experiments (FIDES-II) program is focused on studying Light Water Reactor (LWR) fuel behavior during Reactivity-Initiated Accident (RIA) conditions. The Part I M&S cases are based on a series of tests in the Transient Reactor Test (TREAT) facility in the United States and the Nuclear Safety Research Reactor (NSRR) in Japan. The purpose of this work is to evaluate the test design to accomplish its goals in establishing clearer understanding of the effects of power pulse width during RIA conditions. Further, the blind predictions using various computational tools have been performed and compared amongst to interpret the behaviors of high burnup fuels during RIA. While many international participants evaluate the thermal–mechanical behavior of fuel rod under different conditions, a considerable scatter of outputs comes out for the cases due to the disparity between codes in predicting mechanical behaviors. In general, however, the results of thermal–mechanical analysis elaborate that nominal design conditions the shorter pulse width tests in NSRR should cause cladding failures while the TREAT tests appear to have more split prediction of failure or not. Furthermore, the sensitivity analysis varying key testing parameters reveals the considerable effect of power pulse width and total energy deposition on prediction of fuel rod failure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Towards reversible basic linear algebra subprograms: A performance study

Problems such as fault tolerance and scalable synchronization can be efficiently solved using reversibility of applications. Making applications reversible by relying on computation rather than on memory is ideal for large scale parallel computing, especially for the next generation of supercomputers in which memory is expensive in terms of latency, energy, and price. In this direction, a case study is presented here in reversing a computational core, namely, Basic Linear Algebra Subprograms, which is widely used in scientific applications. A new Reversible BLAS (RBLAS) library interface has been designed, and a prototype has been implemented with two modes: (1) a memory-mode in which reversibility is obtained by checkpointing to memory in forward and restoring from memory in reverse, and (2) a computational-mode in which nothing is saved in the forward, but restoration is done entirely via inverse computation in reverse. The article is focused on detailed performance benchmarking to evaluate the runtime dynamics and performance effects, comparing reversible computation with checkpointing on both traditional CPU platforms and recent GPU accelerator platforms. For BLAS Level-1 subprograms, data indicates over an order of magnitude better speed of reversible computation compared to checkpointing. For BLAS Level-2 and Level-3, a more complex tradeoff is observed between reversible computation and checkpointing, depending on computational and memory complexities of the subprograms.

97 MATHEMATICS AND COMPUTING↗