Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Experimental Results of 2-m Heptane, Bakken Crude Oil, and Dilbit Crude Oil Pool Fire Tests Performed for the National Research Council of Canada

This report provides results from a series of 2-m pool fire experiments performed in the Thermal Test Complex at Sandia National Laboratories testing heptane, Bakken crude oil, and dilbit crude oil. The effect of the presence and placement of a calorimeter, fuel supply temperature, and maintaining a constant fuel level were assessed. Measurements include burn rate, surface emissive power, flame height, heat flux to an engulfed calorimeter, heat flux to external instruments, thermocouple temperatures within the fuel and fire plume, and heat release rate. The results indicate that the presence and placement of the calorimeter has the most effect on the measured quantities for the Bakken crude oil and indicated no effect for the Dilbit crude oil. The fuel feed temperature had a slight effect for the heptane fuel, but not for the crude oils. Allowing the fuel to burn down did not have a significant effect on any of the fuels. The Bakken crude oil resulted in the highest average total heat flux to the calorimeter by a factor of about 1.5 and 1.3 higher compared to heptane and the dilbit crude oil, respectively.

02 PETROLEUM↗

Summary report on the mechanical testing performed at INL for creep rupture, fatigue, creep-fatigue, and aging of A709 base material

The report provides the status of the creep, fatigue, and creep-fatigue testing to conducted at Idaho National Laboratory to generate a data package to support Alloy 709 qualification in American Society of Mechanical Engineers, Boiler and Pressure Vessel Code, Section III, Division 5. These tests were performed on three commercial heats of plate material. The first procured heat was manufactured by G.O. Carlson with heat number 58776. Second and third heats were fabricated by ATI Specialty Rolled Products, with heat numbers 529900 and 530843, respectively. A series of creep and cyclic specimens were fabricated from these three heats, and tests were performed. This report presents a master list of all completed and ongoing creep, fatigue, and creep fatigue tests. Cyclic properties of three commercial heats are compared. Thermal aging of three commercial heats for 3000 hours were completed in FY 2025. The thermal aging campaign to age plate material from three commercial heats up to 100,000 hours is ongoing.

36 - MATERIALS SCIENCE↗

High Solids Performance Testing in a Scaled TSCR System

The Tank Side Cesium Removal (TSCR) project is a technology demonstration that will pretreat Hanford tank waste supernatant in support of the Direct Feed Low-Activity Waste (DFLAW) mission. The TSCR system employs two key separation technologies: dead-end filtration (DEF) and ion exchange (IX) using crystalline silicotitanate (CST) media. DEF will be used to remove undissolved solids from tank waste to protect the functionality of the IX columns and the IX system will remove Cs-137 from tank waste. The separation technologies (DEF and IX) used in TSCR are technically mature and have also been successfully deployed at the Savannah River site in a similar facility known as the Tank Closure Cesium Removal (TCCR) system. While testing with simulants and real waste has been successfully performed under conditions expected during the initial operation of TSCR, test data is absent for assessing off normal high solids loading that may be in the TSCR waste feed. Normal TSCR treatment operations are expected to handle wastes with solids content on the order of 200 ppm, and off normal solids loading could be much larger than the nominal level. The testing program described in this report was conducted to understand the consequence of operating the TSCR system at elevated solids loadings up to the high-solids limit of 15,000 ppm [i.e., 1.5-wt%] identified in the TSCR design basis. Although the system is not required to make throughput above the nominal solids loading, the testing was intended to provide important information related to potential off normal operations. At off normal levels near the high-solids limit, there are potential implications for TSCR performance in the areas of throughput, DEF pressure drop, filter backflush frequency, and IX column pressure drop. In addition, intrusion of solids into the IX column was postulated to impact the Cs-137 loading behavior by promoting channeling or flow maldistribution in the column; since the magnitude of the postulated effect was unknown, assessing it was also of interest. The testing was performed using representative waste simulants and a prototypic, integrated TSCR system designed and assembled specifically to conduct the high solids performance assessment. Overall, the scaled TSCR testing demonstrated that full-scale unit operations can succeed in fulfilling their processing objectives in the presence of solids up to 3,000 ppm, but there are potential performance challenges to filtration operations at solids loadings as low as ~500 ppm. The severity of the challenge is likely to be dependent on the type and size distribution of solids, of which the current testing only examined a single type and size distribution. To provide some flexibility for future full-scale operations, the results of the testing suggest two possible risk reduction strategies that can be implemented without any changes in TSCR design or configuration. One option would be to enact an administrative limit on the solids loading to protect TSCR from feeds that are likely to require a high DEF swap frequency. Another option is to permit operation of the DEFs at differential pressures greater than 2 psid before swapping filters. The selection of a higher differential pressure target is not anticipated to adversely impact DEF backflushing efficacy and would reduce both swap frequency and the amount of waste sent to AP-108.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Requirements for Defining Utility Drive Cycles: An Exploratory Analysis of Grid Frequency Regulation Data for Establishing Battery Performance Testing Standards

Battery testing procedures are important for understanding battery performance, including degradation over the life of the battery. Standards are important to provide clear rules and uniformity to an industry. The work described in this report addresses the need for standard battery testing procedures that reflect real-world applications of energy storage systems to provide regulation services to grid operators. This work was motivated by the need to develop Vehicle-to-Grid (V2G) testing procedures, or V2G drive cycles. Likewise, the stationary energy storage community is equally interested in standardized testing protocols that reflect real-world grid applications for providing regulation services. As the first of several steps toward standardizing battery testing cycles, this work focused on a statistical analysis of frequency regulation signals from the Pennsylvania-New Jersey-Maryland Interconnect with the goal to identify patterns in the regulation signal that would be representative of the entire signal as a typical regulation data set. Results from an extensive time-series analysis are discussed, and the results are explained from both the statistical and the battery-testing perspectives. The results then are interpreted in the context of defining a small set of V2G drive cycles for standardization, offering some recommendations for the next steps toward standardizing testing protocols.

25 ENERGY STORAGE↗

PERFORMANCE TESTING OF THE NEXT-GENERATION CSSX SOLVENT WITH ACTUAL SRS TANK WASTE

Efforts are underway to qualify the Next-Generation Solvent for the Caustic Side Solvent Extraction (CSSX) process. Researchers at multiple national laboratories have been involved in this effort. As part of the effort to qualify the solvent extraction system at the Savannah River Site (SRS), SRNL performed a number of tests at various scales. First, SRNL completed a series of batch equilibrium, or Extraction-Scrub-Strip (ESS), tests. These tests used {approx}30 mL of Next-Generation Solvent and either actual SRS tank waste, or waste simulant solutions. The results from these cesium mass transfer tests were used to predict solvent behavior under a number of conditions. At a larger scale, SRNL assembled 12 stages of 2-cm (diameter) centrifugal contactors. This rack of contactors is structurally similar to one tested in 2001 during the demonstration of the baseline CSSX process. Assembly and mechanical testing found no issues. SRNL performed a nonradiological test using 35 L of cesium-spiked caustic waste simulant and 39 L of actual tank waste. Test results are discussed; particularly those related to the effectiveness of extraction.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Building fault detection data to aid diagnostic algorithm creation and performance testing

It is estimated that approximately 4-5% of national energy consumption can be saved through corrections to existing commercial building controls infrastructure and resulting improvements to efficiency. Correspondingly, automated fault detection and diagnostics (FDD) algorithms are designed to identify the presence of operational faults and their root causes. A diversity of techniques is used for FDD spanning physical models, black box, and rule-based approaches. A persistent challenge has been the lack of common datasets and test methods to benchmark their performance accuracy. This article presents a first of its kind public dataset with ground-truth data on the presence and absence of building faults. This dataset spans a range of seasons and operational conditions and encompasses multiple building system types. It contains information on fault severity, as well as data points reflective of the measurements in building control systems that FDD algorithms typically have access to. The data were created using simulation models as well as experimental test facilities, and will be expanded over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Testing of Enhanced Linear Variable Integrated Sensor (ELVIS III) for LVDTs

The Enhanced Linear Variable Intrinsic Sensor (ELVIS) was a 2024 breakthrough discovery by Idaho National Laboratory (INL) in terms of further innovating the usage of all linear variable differential transformers (LVDTs) and enhancing their performance in harsh environments. In irradiation tests conducted within material test reactors (MTRs), LVDTs with an internal temperature sensing capability can address several critical challenges. This report focuses on performance testing of the ELVIS III device with new hybrid LVDTs provided by the Institute for Energy Technology (IFE), which is the world’s sole supplier of nuclear-grade LVDTs. The ELVIS III device was evaluated in terms of temperature showcasing promising results comparable to a typical type-K thermocouple (TC).

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

In-Field Performance Testing of the Fork Detector for Quantitative Spent Fuel Verification

Expanding spent fuel dry storage activities worldwide are increasing demands on safeguards authorities that perform inspections. The European Atomic Energy Community (EURATOM) and the International Atomic Energy Agency (IAEA) require measurements to verify declarations when spent fuel is transferred to difficult-to-access locations, such as dry storage casks and the repositories planned in Finland and Sweden. EURATOM makes routine use of the Fork detector to obtain gross gamma and total neutron measurements during spent fuel inspections. Data analysis is performed by modules in the integrated Review and Analysis Program (iRAP) software, developed jointly by EURATOM and the IAEA. Under the framework of the US Department of Energy–EURATOM cooperation agreement, a module for automated Fork detector data analysis has been developed by Oak Ridge National Laboratory (ORNL) using the ORIGEN code from the SCALE code system and implemented in iRAP. EURATOM and ORNL recently performed measurements on 30 spent fuel assemblies at the Swedish Central Interim Storage Facility for Spent Nuclear Fuel (Clab), operated by the Swedish Nuclear Fuel and Waste Management Company (SKB). The measured assemblies represent a broad range of fuel characteristics. Neutron count rates for 15 measured pressurized water reactor assemblies are predicted with an average relative standard deviation of 4.6%, and gamma signals are predicted on average within 2.6% of the measurement. The 15 measured boiling water reactor assemblies exhibit slightly larger deviations of 5.2% for the gamma signals and 5.7% for the neutron count rates, compared to measurements. These findings suggest that with improved analysis of the measurement data, existing instruments can provide increased verification of operator declarations of the spent fuel and thereby also provide greater ability to confirm integrity of an assembly. These results support the application of the Fork detector as a fully quantitative spent fuel verification technique.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of Model Predictions and Performance Test Data for a Prototype Thermal Energy Storage Module

Although model predictions of thermal energy storage (TES) performance have been explored in previous investigations, relevant test data that enable experimental validation of performance models have been limited. This is particularly true for high-performance TES designs that facilitate fast input and extraction of energy. In this paper, we present a summary of experimental tests of a high-performance TES unit using lithium nitrate trihydrate phase change material as a storage medium. Performance data are presented for complete dual-mode cycles consisting of extraction (melting) followed by charging (freezing). These tests simulate the cyclic operation of a TES unit for asynchronous cooling in a variety of applications. Finally, the model analysis is found to agree reasonably well, within 10%, with the experimental data except for conditions very near the initiation of freezing, a consequence of subcooling that is required to initiate solidification.

25 ENERGY STORAGE↗

Acceptance Performance Test Guideline for Utility Scale Parabolic Trough and Other CSP Solar Thermal Systems: Preprint

Prior to commercial operation, large solar systems in utility-size power plants need to pass a performance acceptance test conducted by the engineering, procurement, and construction (EPC) contractor or owners. In lieu of the present absence of ASME or other international test codes developed for this purpose, the National Renewable Energy Laboratory has undertaken the development of interimguidelines to provide recommendations for test procedures that can yield results of a high level of accuracy consistent with good engineering knowledge and practice. Progress on interim guidelines was presented at SolarPACES 2010. Significant additions and modifications were made to the guidelines since that time, resulting in a final report published by NREL in April 2011. This paper summarizesthose changes, which emphasize criteria for assuring thermal equilibrium and steady state conditions within the solar field.

14 SOLAR ENERGY↗

Washington Clean Energy Fund: Energy Storage System Performance Test Plans and Data Requirements

This report documents the test plans, including detailed duty cycles, used in evaluating the technical performance of five energy storage systems (ESSs) sponsored by the Washington State Clean Energy Fund (CEF). These ESSs were installed at three participating utilities’ (Avista, Snohomish Public Utility District or SnoPUD, and Puget Sound Energy or PSE) designated sites. Under each test plan, a number of baseline and use case tests are defined. This report documents the test plan for each utility, including duty cycles, data and performance reporting requirements. Baseline tests defined in this report mainly focus on determining an initial or reference performance for each ESS, which may be compared with the performance at any later time to assess the state of health of the ESS. Parameter values of a given ESS obtained from baseline tests are applied for different modeling purposes and use case tests. The stored energy capacity test is the first test conducted in the baseline test program, which generates data to calculate round trip efficiency (RTE). The response time and ramp rate tests provide the time required for an ESS to change from zero to full charging/discharging rate and hence the ramp rate, which is important in understanding ESS performance for applications calling for fast response. Internal resistance testing of ESS cells is also conducted in conjunction with the response time and ramp rate tests. Finally, the baseline tests include frequency regulation (FR) and peak shaving (PS) tests based on real-world duty cycles. Upon completion of the baseline tests, use case tests are conducted at each of the storage sites with duty cycles developed to meet the site-specific criteria and conditions. The use cases are grouped according to their intended target benefits within the electric infrastructure topology (e.g., transmission versus distribution). Although an ESS may be located on the low-voltage side of a substation that provides power to a distribution feeder, a use case that addresses bulk power services could still be provided and would be grouped under the transmission or bulk-power benefits. Use cases for ESS applications deep into the distribution circuit would be categorized under the distribution system cases.

25 ENERGY STORAGE↗

Wind-To-Hydrogen Project: Operational Experience, Performance Testing, and Systems Integration

The Wind2H2 system is fully functional and continues to gather performance data. In this report, specifications of the Wind2H2 equipment (electrolyzers, compressor, hydrogen storage tanks, and the hydrogen fueled generator) are summarized. System operational experience and lessons learned are discussed. Valuable operational experience is shared through running, testing, daily operations, and troubleshooting the Wind2H2 system and equipment errors are being logged to help evaluate the reliability of the system.

08 HYDROGEN↗

NREL Energy Performance Testing of Asetek's RackCDU System on a Single Rack of Twin Blade Servers: Cooperative Research and Development Final Report, CRADA Number CRD-13-518

The project will entail Asetek retrofitting 1 - 2 compute racks of servers at the National Renewable Energy Laboratory (NREL) to test and validate RackCDU's cooling performance and long-term reliability. The project will also entail measuring and reporting energy savings under a real workload by comparing total power input to the system vs. total heat removed by liquid and air. Direct measurements will be made to compare and contrast energy consumption and performance both before and after RackCDU installation. The scope of this project is strictly demonstration and feedback on the system. No development work will be performed under this CRADA.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Injector Cavities Fabrication, Vertical Test Performance and Primary Cryomodule Design

After the electromagnetic design and the mechanical design of a β=0.6, 2-cell elliptical SRF cavity, the cavity has been fabricated. Then both 2-cell and 7-cell cavities have been bench tuned to the target values of frequency, coupling external Q and field flatness. After buffer chemistry polishing (BCP) and high pressure rinses (HPR), Vertical 2K cavity test results have been satisfied the specifications and ready for the string assembly. We will report the cavity performance including Lorenz Force Detuning (LFD) and Higher Order Modes (HOM) damping data. Its integration with cavity tuners to the cryomodule design will be reported.

43 PARTICLE ACCELERATORS↗

Performance Test Protocol for Evaluating Inverters Used in Grid-Connected Photovoltaic Systems

Interconnection equipment that connects distributed resources (DR) to an electrical power system (EPS) are expected to do so efficiently. Standardized test procedures are necessary to establish methods for verifying inverter performance that leads to comparable results. These test procedures are provided as a repeatable, independent means of measuring inverter performance regarding maximum continuous power rating, conversion efficiency, and tare loss characteristics.

14 SOLAR ENERGY↗