Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase shifting interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Filter Aerosol Measurements for ARM

The goal of this study was to determine the best filter media for use in ARM PSAPs following the manufacturer discontinuation of the current filter media. The study comprised by multiple experiments to assess four potential replacement filter medium relative to the Pallflex E-70, which is being discontinued, and is documented in ARM ServiceNow under ENG0003846. The experiments laid out in the document ‘180504 Filter Aerosol Measurements for ARM.docx’ and several subsequent tests suggest that the Pallflex Emfab media is the best candidate for ongoing ARM filter-based absorbance measurements. Other media were ruled out based on particle-capture efficiency for small particles. In tests with Nigrosin, EMFAB exceeded all other media. Tests were done measuring reported absorbance for all media in Particle Soot Absorption Photometers (PSAPs) operated in parallel sampling under several conditions: ambient air, 3 sizes of black-dyed PSL (Poly Styrene Latex) spheres, and Nigrosin particles. These tests indicate a different factor of reported absorbance for each media relative to the original Pallflex E70 filter. The factor for the Azumi media was consistent with unpublished work by Ogren (NOAA). The tests described here were not exhaustive and were complicated by time-varying differences among the PSAPs used. However, it is concluded that they are sufficient to justify ARM switching to Emfab filter media for future ARM PSAP measurements. The remaining store of E70 will be reserved to quantitatively characterize differences between Emfab and E70 (and Azumi?) in both laboratory and field side-by-side tests as put forth in a succeeding ENG. This future work will empirically identify correction factors applicable to Emfab and quantify the uncertainty in comparing the historical E70 measurements with ongoing Emfab measurements. Comparison of PSAP measurements with an independent absolute ‘reference’ for aerosol absorbance, i.e., PhotoThermal Interferometry or difference measurements of Cavity Attenuated Phase Shift extinction (CAPS) minus Nephelometry scattering would be valuable but exceed the scope of ARM Infrastructure. While the characterization of correction factors is required for maintaining and improving accuracy in future absorption measurements, it was beyond the scope of the current study.

54 ENVIRONMENTAL SCIENCES↗

Filter Aerosol Measurements for ARM

The goal of this study was to determine the best filter media for use in Atmospheric Radiation Measurement (ARM) particle soot absorption photometers (PSAPs) following the manufacturer discontinuation of the current filter media. The study comprised multiple experiments to assess four potential replacement filter medium relative to the Pallflex E-70, which is being discontinued, and is documented in ARM’s ServiceNow system under ENG0003846. The experiments laid out in the document ‘180504 Filter Aerosol Measurements for ARM.docx’ and several subsequent tests suggest that the Pallflex Emfab media is the best candidate for ongoing ARM filter-based absorbance measurements. Other media were ruled out based on particle capture efficiency for small particles. In tests with Nigrosin, Emfab exceeded all other media. Tests were done measuring reported absorbance for all media in PSAPs operated in parallel sampling under several conditions: ambient air, three sizes of black-dyed PSL (polystyrene latex) spheres, and Nigrosin particles. These tests indicate a different factor of reported absorbance for each media relative to the original Pallflex E70 filter. The factor for the Azumi media was consistent with unpublished work by Ogren (National Oceanic and Atmospheric Administration [NOAA]). The tests described here were not exhaustive and were complicated by time-varying differences among the PSAPs used. However, it is concluded that they are sufficient to justify ARM switching to Emfab filter media for future ARM PSAP measurements. The remaining store of E70 will be reserved to quantitatively characterize differences between Emfab and E70 (and Azumi?) in both laboratory and field side-by-side tests as put forth in a succeeding ENG. This future work will empirically identify correction factors applicable to Emfab and quantify the uncertainty in comparing the historical E70 measurements with ongoing Emfab measurements. Comparison of PSAP measurements with an independent absolute ‘reference’ for aerosol absorbance, i.e., photo thermal interferometry or difference measurements of cavity attenuated phase shift extinction (CAPS) minus nephelometry scattering, would be valuable but exceed the scope of ARM Infrastructure. While the characterization of correction factors is required for maintaining and improving accuracy in future absorption measurements, it was beyond the scope of the current study.

aerosol observing system↗

Continuous phase amplification with a Sagnac interferometer

We describe a phase-amplification technique using a Sagnac interferometer. We monitor the relative phase between two paths of a precisely misaligned interferometer by measuring the average position of a split-Gaussian mode in the dark port. Although we monitor only the dark port, we show that the signal varies linearly with phase and that we can obtain similar sensitivity to balanced homodyne detection. We derive the source of the amplification using classical wave optics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental investigation on the energy deposition and expansion rate under the electrical explosion of aluminum wire in vacuum

Experimental investigations on the electrical explosion of aluminum wire using negative polarity current in vacuum are presented. Current pulses with rise rates of 40 A/ns, 80 A/ns, and 120 A/ns are generated for investigating the influence of current rise rate on energy deposition. Experimental results show a significant increase of energy deposition into the wire before the voltage breakdown with the increase of current rise rate. The influence of wire dimension on energy deposition is investigated as well. Decreasing the wire length allows more energy to be deposited into the wire. The energy deposition of a 0.5 cm-long wire explosion is ∼2.5 times higher than the energy deposition of a 2 cm-long wire explosion. The dependence of the energy deposition on wire diameter demonstrates a maximum energy deposition of 2.7 eV/atom with a diameter of ∼18 μm. Substantial increase in energy deposition is observed in the electrical explosion of aluminum wire with polyimide coating. A laser probe is applied to construct the shadowgraphy, schlieren, and interferometry diagnostics. The morphology and expansion trajectory of exploding products are analyzed based on the shadowgram. The interference phase shift is reconstructed from the interferogram. Parallel dual wires are exploded to estimate the expansion velocity of the plasma shell.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of conformational molecular dynamics on matter wave interferometry

We investigate the influence of thermally activated internal molecular dynamics on the phase shifts of matter waves inside a molecule interferometer. While de Broglie physics generally describes only the center-of-mass motion of a quantum object, our experiment demonstrates that the translational quantum phase is sensitive to dynamic conformational state changes inside the diffracted molecules. The structural flexibility of tailor-made organic particles is sufficient to admit a mixture of strongly fluctuating dipole moments. These modify the electric susceptibility and through this the quantum interference pattern in the presence of an external electric field. Detailed molecular dynamics simulations combined with density-functional theory allow us to quantify the time-dependent structural reconfigurations and to predict the ensemble-averaged square of the dipole moment which is found to be in good agreement with the interferometric result. The experiment thus opens a different perspective on matter wave interferometry, as we demonstrate here that it is possible to collect structural information about molecules even if they are delocalized over more than 100 times their own diameter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of moire fringes by Wiener filtering: An extension to the Fourier method

In X-ray Talbot interferometry, tilting the phase grating with respect to the absorption grating results in the formation of spatial fringes. The analysis of this moire pattern, classically performed by the Fourier method, allows the extraction of the sample phase shift information from a single image. In this context, an extension to the Fourier method is proposed. The filter used to extract the fringe information is chosen optimally in the least-squares sense, given models for the zeroth and first order modes, noise and the modulation transfer function. The latter is obtained by measuring the detector response to moire fringes with increasing frequencies. The obtained Wiener filter allows a better reconstruction of the phase information at all fringe frequencies, compared to the usual box or gaussian filters. This is demonstrated quantitatively by experiments using synchrotron radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spherical grating based x-ray Talbot interferometry

Purpose: Grating interferometry is a state-of-the-art x-ray imaging approach, which can acquire information on x-ray attenuation, phase shift, and small-angle scattering simultaneously. Phase-contrast imaging and dark-field imaging are very sensitive to microstructural variation and offers superior contrast resolution for biological soft tissues. However, a common x-ray tube is a point-like source. As a result, the popular planar grating imaging configuration seriously restricts the flux of photons and decreases the visibility of signals, yielding a limited field of view. The purpose of this study is to extend the planar x-ray grating imaging theory and methods to a spherical grating scheme for a wider range of preclinical and clinical applications. Methods: A spherical grating matches the wave front of a point x-ray source very well, allowing the perpendicular incidence of x-rays on the grating to achieve a higher visibility over a larger field of view than the planer grating counterpart. A theoretical analysis of the Talbot effect for spherical grating imaging is proposed to establish a basic foundation for x-ray spherical gratings interferometry. An efficient method of spherical grating imaging is also presented to extract attenuation, differential phase, and dark-field images in the x-ray spherical grating interferometer. Results: Talbot self-imaging with spherical gratings is analyzed based on the Rayleigh–Sommerfeld diffraction formula, featuring a periodic angular distribution in a polar coordinate system. The Talbot distance is derived to reveal the Talbot self-imaging pattern. Numerical simulation results show the self-imaging phenomenon of a spherical grating interferometer, which is in agreement with the theoretical prediction. Conclusions: X-ray Talbot interferometry with spherical gratings has a significant practical promise. Relative to planar grating imaging, spherical grating based x-ray Talbot interferometry has a larger field of view and improves both signal visibility and dose utilization for pre-clinical and clinical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental investigation on the energy deposition and morphology of the electrical explosion of copper wire in vacuum

This paper presents the experimental results of the electrical explosion of copper wires in vacuum using negative nanosecond-pulsed current with magnitude of 1–2 kA. The 20 μm-diameter copper wires with different lengths are exploded with three different current rates. A laser probe is applied to construct the shadowgraphy and interferometry diagnostics to investigate the distribution and morphology of the exploding product. The interference phase shift is reconstructed from the interferogram, by which the atomic density distribution is calculated. Experimental results show that there exist two voltage breakdown modes depending on the amount of the specific energy deposition. For the strong-shunting mode, shunting breakdown occurs, leading to the short-circuit-like current waveform. For the weak-shunting mode with less specific energy deposition, the plasma generated during the voltage breakdown is not enough to form a conductive plasma channel, resulting in overdamped declining current waveform. The influence of the wire length and current rate on the characteristics of the exploding wires is also analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiphoton- and simultaneous conjugate Ramsey-Borde atom interferometers

We report on our experiment to measure h/M, the ratio of the Planck constant to the mass of Cs atoms, and thereby the fine-structure constant. The target accuracy is 1 part per billion or better. We focus on two recent milestones: (i) The first realization of atom interferometers based on light-pulse beam splitters that transfer the momentum of up to 12 photon pairs, which increases the useful signal (matter wave phase shift) by a factor of 144 compared to the beam splitters used in the best present atom interferometers. Moreover, they lead to a cancellation of important systematic effects. (ii) The first realization of a simultaneous pair of conjugate Ramsey-Borde interferometers. In these, the relative sign of the inertial term is reversed so that it can be cancelled. Simultaneous operation means that this holds for a time-dependent inertial term (vibrations) too, which promises a substantial improvement in the signal to noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital phase demodulation for low-coherence interferometry-based fiber-optic sensors

In this paper, we describe a digital phase demodulation scheme for low-coherence interferometry-based fiber-optic sensors by employing a simple generation of phase-shifted signals at the interrogation interferometer. The scheme allows a real-time calibration process and offers capability of measuring large variations (up to the coherence of the light source) at the bandwidth that is only limited by the data acquisition system. Finally, the proposed phase demodulation method is analytically derived and its validity and performance are experimentally verified using fiber-optic Fabry–Perot sensors for measurement of strains and vibrations.

47 OTHER INSTRUMENTATION↗

Thermally induced dispersive optical bistability in silver nanosuspensions produced by pulsed laser ablation method

The thermally induced optical bistability in prepared silver (Ag) nanosuspensions have been studied experimentally, using Fabry–Perot and Mach–Zehnder interferometry methods. Two Ag nanosuspensions of different sizes were produced by different fluences of pulsed laser ablation method in distilled water. The pulsed Nd:YAG laser of 7 ns pulse width, 1064 nm wavelength and different fluences was employed to produce Ag nanosuspensions. Experimental observations were performed by an ultraviolet–visible–near infrared spectrophotometry. Structure and size of prepared Ag nanoparticles were diagnosed using transmission electron microscope images. Fabry–Perot and Mach–Zehnder interferometry methods were used to carry out the optical bistability process in prepared Ag nanosuspensions. In two considered interferometers, the obtained phase shifts of the hysteresis loops based on the optical bistability are inversely proportional to the nonlinear refractive index of samples and thickness of Ag nanosuspensions cells. Results indicate that the induced thermal effect of the optical bistability can be tuned by modifying parameters such as the nonlinear refractive index and applied interferometry methods. Hence, a desirable situation for the thermo-optical effects of the optical bistability can be easily realized in Ag nanosuspensions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

2D image of local density and magnetic fluctuations from line-integrated interferometry-polarimetry measurements

Combined polarimetry-interferometry capability permits simultaneous measurement of line-integrated density and Faraday effect with fast time response (∼1 μs) and high sensitivity. Faraday effect fluctuations with phase shift of order 0.05° associated with global tearing modes are resolved with an uncertainty ∼0.01°. For physics investigations, local density fluctuations are obtained by inverting the line-integrated interferometry data. The local magnetic and current density fluctuations are then reconstructed using a parameterized fit of the polarimetry data. Reconstructed 2D images of density and magnetic field fluctuations in a poloidal cross section exhibit significantly different spatial structure. Combined with their relative phase, the magnetic-fluctuation-induced particle transport flux and its spatial distribution are resolved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sagnac effect in a chain of mesoscopic quantum rings

The ability to interferometrically detect inertial rotations via the Sagnac effect has been a strong stimulus for the development of atom interferometry because of the potential 10{sup 10} enhancement of the rotational phase shift in comparison to optical Sagnac gyroscopes. Here we analyze ballistic transport of matter waves in a one-dimensional chain of N coherently coupled quantum rings in the presence of a rotation of angular frequency {omega}. We show that the transmission probability, T, exhibits zero transmission stop gaps as a function of the rotation rate interspersed with regions of rapidly oscillating finite transmission. With increasing N, the transition from zero transmission to the oscillatory regime becomes an increasingly sharp function of {omega} with a slope {partial_derivative}T/{partial_derivative}{omega}{approx}N{sup 2}. The steepness of this slope dramatically enhances the response to rotations in comparison to conventional single ring interferometers such as the Mach-Zehnder interferometer and leads to a phase sensitivity well below the quantum shot-noise limit typical of atom interferometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cadmium zinc telluride based infrared interferometry for X-ray detection

Cadmium Zinc Telluride (CZT) is a wide band gap semiconductor for room temperature radiation detection. The electro-optic Pockels effect of the material has been exploited in the past to study electric field non-uniformities and their consequence on conventional detector signals in CZT, by imaging the intensity distribution of infrared (IR) light transmitted through a device placed between crossed polarizers. Recently, quantitative monitoring of extremely high intensity neutron pulses through the change of transmitted IR intensity was demonstrated, offering the advantage to place sensitive electronics outside the measured radiation field. In this work, we demonstrate that X-ray intensity can be deduced directly from measuring the change in phase of 1550 nm laser light transmitted through a 7 × 7 × 2 mm{sup 3} CZT based Pockels cell in a simple Mach Zehnder interferometer. X-rays produced by a 50 kVp Mo X-ray tube incident on the CZT cathode surface placed at 7 mm distance cause a linearly increasing phase shift above 0.3 mA tube current, with 1.58 ± 0.02 rad per mA for an applied bias of 500 V across the 2 mm thick device. Pockels images confirm that the sample properties are in agreement with the literature, exhibiting electric field enhancement near the cathode under irradiation, which may cause the non-linearity at low X-ray tube anode current settings. The laser used to probe the X-ray intensity causes itself some space charge, whose spatial distribution does not seem to be exclusively determined by the incident laser position, i.e., charge carrier generation location, with respect to the electrodes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electronic speckle pattern interferometry and digital holographic interferometry with microbolometer arrays at 10.6 {mu}m

Electronic speckle pattern interferometry and digital holographic interferometry are investigated at long infrared wavelengths. Using such wavelengths allows one to extend the measurement range and decrease the sensitivity of the techniques to external perturbations. We discuss the behavior of reflection by the object surfaces due to the long wavelength. We have developed different experimental configurations associating a CO2 laser emitting at 10.6{mu}m and microbolometer arrays. Phase-shifting in-plane and out-of-plane electronic speckle pattern interferometry and lensless digital holographic interferometry are demonstrated on rotation measurements of a solid object.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical simulation of solar wind density fluctuations and their effects on VLF radio interferometry

A mission consisting of an array of small satellites has been proposed to investigate radio sources at frequencies from approximately 2 to 20 MHz, a range unobservable from the ground because of ionospheric absorption and aberrations. Such a mission seems feasible and relatively inexpensive, but further investigation is still necessary. The solar wind is a major concern because it contains turbulence-induced random density variations that cause a fluctuating phase shift in any electromagnetic signal passing through, sometimes making radio source imaging by interferometry impossible. A numerical simulation has been developed which attempts to accurately characterize solar wind density fluctuations. Results have allowed more concrete conclusions to be drawn about observing constraints and have shown that interferometric imaging at radio frequencies below 10 MHz with baselines up to 100 km is possible at solar elongation angles of about 90 deg or more.

Williamson, Robert S., III↗

General relativistic effects in atom interferometry

Atom interferometry is now reaching sufficient precision to motivate laboratory tests of general relativity. We begin by explaining the nonrelativistic calculation of the phase shift in an atom interferometer and deriving its range of validity. From this, we develop a method for calculating the phase shift in general relativity. Both the atoms and the light are treated relativistically and all coordinate dependencies are removed, thus revealing novel terms, cancellations, and new origins for previously calculated terms. This formalism is then used to find the relativistic effects in an atom interferometer in a weak gravitational field for application to laboratory tests of general relativity. The potentially testable relativistic effects include the nonlinear three-graviton coupling, the gravity of kinetic energy, and the falling of light. We propose specific experiments, one currently under construction, to measure each of these effects. These experiments could provide a test of the principle of equivalence to 1 part in 10{sup 15} (300 times better than the present limit), and general relativity at the 10% level, with many potential future improvements. We also consider applications to other metrics including the Lense-Thirring effect, the expansion of the Universe, and preferred frame and location effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

4D PhaseCam(Trade Mark) Capabilities: Modal Analysis and Multiple-Wavelength Mirror Phasing

The PhaseCam is a dynamic phase shifting interferometer system manufactured by 4D Technology Corporation that is capable of very fast data acquisition. This rapid acquisition extends the capability of conventional interferometry to enable measurement in unstable environments, the generation of phase movies of surface shape and to facilitate modal analysis of structures. The PhaseCam hardware and software have been modified for MSFC to include synchronous modal optical measurement and analysis. These modifications will be discussed and data presented. The dynamic range of a phase shifting measurement is limited by local slope and pixel sampling to lambda/4 wave steps. Two-wavelength techniques can increase the effective measurement wavelength from microns to tens of centimeters and permit the phasing of mirror segments. A two wavelength PhaseCam will be discussed and measurement results presented.

Millerd, James E.↗