Search NASA⌕ Search

SEARCH · Search NASA

Results for “phasor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A Framework for Model Validation and Calibration of Microgrid Components Using PMU Data

This paper presents a framework for phasor measurement-based component model validation and calibration islanded microgrids, with emphasis on grid-forming inverters. Real measurements from the Plum Island microgrid facility are used to calibrate the model of a commercial inverter in the open-source phasor-based distribution system simulator GridLAB-D.Limitations of current distribution system simulators in replicating the behavior of commercial inverters are also identified.

microgrid, Synchrophasor data, model validation↗

Assessing the Accuracy of Balanced Power System Models in the Presence of Voltage Unbalance

Traditional models of electric power systems represent distribution systems with unbalanced three-phase network models and transmission systems with balanced single-phase-equivalent network models. This distinction poses a challenge for coupled models of transmission and distribution systems, which are becoming more prevalent due to the growth of distributed energy resources connected to distribution systems. In order to maintain a balanced network representation, transmission system models typically assume that the voltage phasors at the interface to the distribution system are balanced. Inaccuracies resulting from this assumption during unbalanced operation can lead to erroneous values for line currents in the transmission system model. This paper empirically quantifies the accuracy of this balanced operating assumption during unbalanced operating conditions for both a simple two-bus system along with a more complex transmission and distribution co-simulation. This paper also characterizes the performance of different methods for translating the unbalanced voltage phasors into a balanced representation in order to give recommendations for modeling coupled transmission and distribution systems.

power distribution↗

Data-Driven PMU Noise Emulation Framework using Gradient-Penalty-Based Wasserstein GAN

Availability of phasor measurement unit (PMUs) data has led to research on data-driven algorithms for event monitoring, control and ensuring stability of the grid. Unavailability of infrequent critical event field PMU data with component failures is driving the need to generate realistic synthetic PMU data for research. The synthetic data from power system simulation software often neglect noise profiles of received phasors, thus creating some discrepancies between real PMU data and synthetic ones. To address this issue, this work presents an initial study on the noise characteristics of PMUs, as well as presenting models for recreating their unique noise signatures. The proposed method, utilizing the Wasserstein generative adversarial network with gradient penalty (WGAN-GP) architecture, provides an excellent benchmark for matching the noise distribution. One can use a well-learned GAN model to draw noise signatures from a distribution that seemingly mirrors the real PMU noise distribution, while also being able to be detached from the PMU data once the training is done. Based on the observed results and employed data-driven methodology, it is expected that the proposed methods can be adapted to replicate the behavior of other sensors, providing research and other applications with a tool for data synthesis and sensor characterization.

PMU↗

Alignment Method for Synchronized Phase Angle Measurement With Presence of Practical Time Shift

Synchronized Phase Angle Measurements (SPAMs) are widely used in power systems in the applications of situational awareness. However, the practical time shifts can lead to unexpected angle differences among Phasor Measurement Units (PMUs) manufactured from various vendors. Moreover, since most of PMUs calculate phase angle via Discrete Fourier Transform based approaches, this issue becomes even worse under the off-nominal frequency condition. To mitigate the impact of practical timing shift, this letter presents a fast method to rectify the SPAM for appropriate alignment. To verify the performance of the proposed method, laboratory and field tests have been conducted by implementing the method in PMUs and phasor data concentrators, respectively. The results demonstrate that the standard deviations of the phase angle differences have significantly decreased to 0.1$^{\circ }$ order with the adoption of the proposed method.

42 ENGINEERING↗

Resiliency-Driven Proactive Distribution System Reconfiguration With Synchrophasor Data

Measuring and enabling resiliency of electric distribution systems with increasing weather and cyber events are important. Some of the extreme events (e.g. Earthquakes, Hurricanes) and associated paths are predicted and monitored closely in advance and allow to take pre-event proactive control actions. The Distribution Phasor Measurement Units (D-PMUs) provide new opportunities and supporting such proactive actions. Here, a synchrophasor based resiliency driven pre-event reconfiguration can ensure minimizing impact of the expected event on the power distribution system and associated performance. However, the D-PMUs will also face challenges in terms of data quality similar to the transmission PMUs. The focus of this paper is to provide data mining approaches for anomaly detection in D-PMUs and proposing resiliency-driven pre-event reconfiguration with islanding as a proactive mechanisms to minimize the impact of adverse events on system using processed synchrophasors data. Results are validated for real industrial feeders and test cases with satisfactory response

controlled islanding↗

Analysis of a Disturbance Event with Inverter-Based Resources Using EMT Simulations

Increasing penetration of inverter-based resources (IBRs) necessitates newer methods of planning and analysis of disturbances. The existing phasor-domain transient stability (TS) analysis may not capture the dynamics of IBRs during fault events. Here, in this paper, electromagnetic transient (EMT) simulations using high-fidelity detailed model of power grid and one of the affected photovoltaic (PV) plants during the Angeles Forest disturbance in 2018 are performed. In these simulations, the processes to develop EMT models of power grid from traditional phasor-domain TS data and PV plant from collected data are described. Thereafter, using these simulations, the response of the PV plant during the fault event in 2018 is replicated and a sensitivity analysis is performed. The sensitivity analysis consists of making changes to the components within the PV plant and in the power grid to evaluate the impact they have on the response observed by the PV plant during the fault event. This analysis provides an understanding of the components that impact the operation of a PV plant during fault events and provide guidance to system planners on the studies that need to be performed to maintain a reliable power grid as new IBR plants are integrated.

42 ENGINEERING↗

HIDES (Hybrid Intrusion Detection for Energy Systems) [SWR-19-65]

Hybrid Intrusion Detection for Energy Systems (HIDES) is a conglomerate detector that incorporates three major components: (1) Signature-based detection that involves information technology (IT) related anomaly detection rules, (2) Behavior-based detection that utilizes specially crafted rulesets for detecting abnormal behavior regarding the power system's supervisory control and data acquisition (SCADA) communication streams, and (3) Learning-based detection that combines SCADA communication with phasor measurements to identify otherwise non-detectible attack vectors. The software itself interconnects intrusion detection engine (IDE) enabling communications between the generated OT and IT alerts with phasor measurements for the learning-based detection system. The resulting detection system can detect a wide array of IT, OT, and physical attacks in a real-time setting.

Rivera, Joshua↗

Combinatorial Evaluation of Physical Feature Engineering, Classical Machine Learning, and Deep Learning Models for Synchrophasor Data at Scale

A major objective of the project was to train and evaluate the effectiveness of multiple event and anomaly detection, identification and classification deep temporal learning models for processing of real-time phasor measurement unit (PMU) data streams. A vast dataset, consisting of two years of phasor measurements from all three U.S. Interconnections, was curated and released by the Department of Energy (DOE) through Pacific Northwest National Laboratory (PNNL). The dataset also included an event log that provided event times and types (e.g. generator trips, line trips, planned service events, transformer operations, etc.). Our analysis of this dataset addressed six (6) of the eleven (11) research priorities identified in Funding Opportunity Announcement (FOA) DE-FOA-0001861 “Big Data Analysis of Synchrophasor Data” (FOA 1861). Rather than being limited to pre-determined specific algorithms, this project relied on the uniquely structured, highly performant underlying time series database capabilities of the PredictiveGrid platform to assess the vast dataset utilizing a wide variety of algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of K-factor on Short Circuit Program Convergence for Inverter-Based Resources during Faults

Classical short-circuit programs that linearize the power network are no longer applicable for inverter based resources (IBRs), necessitating an iterative approach. Phasor domain programs can model the IBRs using an iterative approach considering nonlinear fault responses. In phasor domain models, the IBR can be modeled as a voltage controlled current source (VCCS) in tabular form with positive, negative, and zero sequence information for balanced and unbalance short-circuit faults. In the VCCS modeling of the IBR, positive and negative incremental reactive current, also known as the k-factor, plays an important role in short circuit program convergence. In this work, a few approaches: conventional VCCS modeling with a k-factor of 2, conventional VCCS modeling with a k-factor of 2 with modified pre-fault voltages, VCCS characteristics based on the power flow solution with a k-factor of 2, and VCCS characteristics based on the power flow solution with a k-factor of 1 are investigated for short circuit program convergence under higher IBR penetration. The IEEE 39 bus New England Test System is taken as the test system, and simulations are carried out in PSS®CAPE 15.0.26 simulation software. Simulation results demonstrate that IBR penetration is higher for the VCCS model, which corresponds to the power flow solution with k-factor 1, compared to other approaches.

42 ENGINEERING↗

Assessing Inverter-Based Resources Modeling Gaps in Commonly Used Short-Circuit Programs

Future bulk power systems are expected to operate with a high penetration of inverter-based resources (IBR). This is anticipated to fundamentally change the system’s short-circuit behaviors and demand a change in existing transmission line protection settings or schemes. Phasor-domain short circuit programs (e.g., ASPEN, CAPE, and CYME) remain the mainstream tools for developing protection settings. However, the system protection community has shared concerns about the accuracy of IBR models in short-circuit programs. This report compares the performance of existing generic IBR models in short-circuit programs with detailed electro-magnetic transient (EMT) models provided by several different IBR manufacturers in PSCAD, to quantify the short-circuit program’s IBR model accuracy, assess their ability to replicate individual IBR controls such as negative sequence current injections, and identify specific gaps in the existing generic phasor-domain IBR models that are currently available.

42 ENGINEERING↗

Control Oriented Models for Co-Design: Technical Overview of MT HVDC, MVDC, and Solid State Transformer Building Blocks

The electric power system is shifting toward a power electronics–enabled grid, where converter based “building blocks” (e.g., high voltage direct current (HVDC) links, multi terminal HVDC (MT HVDC) networks, medium voltage DC (MVDC) links, and solid state transformers (SSTs)) provide fast, precise control of power flows, voltage, and frequency. This report develops and applies publicly shareable electromagnetic transient (EMT) and phasor models to examine how such building blocks can be composed and coordinated to support offshore wind integration, inter area transfers, feeder support, and resilience. Section 2 documents a modular multilevel converter (MMC)–based MT HVDC modeling framework and two use cases: a compact WSCC/IEEE 9 bus test system and a 240 bus “mini WECC” case with five offshore wind plants (OWFs). Phasor to EMT transfer, initialization, and sanity checks are summarized, and neutral demonstrations of normal and contingency operation are reported. Section 3 frames the problem of wind plant inertial frequency response (IFR): shaping energy release and recovery to improve nadir while avoiding aerodynamic stall; representative simulations illustrate the issues without disclosing proprietary control. Section 4 develops MVDC concepts through an IEEE 16 bus loop and an Olympic Peninsula case study that compares AC vs. MVDC corridors and shows how feeder headroom can be pooled via DC couplers. Section 5 surveys SST architectures and identifies a gap: scalable, communication free coordination of multiple SSTs for islanded feeder networks. Across the report, novel methods and configurations under separate publication and IP review are not disclosed; only topic oriented, replicable setups and non proprietary results are shown. These models and use cases are intended as foundations for future publications and co design studies on architecture, control, and coordination of PE enabled grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impedance Analysis and PHIL Demonstration of Reactive Power Oscillations in a Wind Power Plant Using a 4-MW Wind Turbine

This paper presents impedance-based analysis, mitigation, and power-hardware-in-the-loop (PHIL) demonstration of reactive power oscillations in a wind power plant using a 4-MW Type III wind turbine drivetrain. Because such low-frequency oscillations result from interactions among slower control loops of wind turbines regulating phasor quantities—active and reactive power output of the wind turbine and the magnitude of voltages at the point of interconnection (POI)—a new type of admittance is defined in terms of phasor quantities for their analysis. The so-called power-domain admittance of a wind turbine is defined as the transfer function from the frequency and magnitude of voltages at the POI to the active and reactive power output of the turbine. The power-domain admittance responses of the 4-MW wind turbine are measured using a 7-MVA grid simulator to identify the source of the reactive power oscillations. Power-domain impedance analysis and PHIL experiments are performed to explain how a resonant mode manifests as turbine-to-turbine and plant-to-grid reactive power oscillations. It is discovered that weaker grids exhibiting high inductive impedance mitigate oscillations in the reactive power output of wind power plants; however, a higher grid impedance does not help in damping turbine-to-turbine reactive power oscillations. This paper presents a simple droop-based solution to eliminate both turbine-to-turbine and plant-to-grid reactive power oscillations.

17 WIND ENERGY↗

Assessment and Commissioning of Electrical Substation Grid Testbed with a Real-Time Simulator and Protective Relays/Power Meters in the Loop

Electrical utility substations are wired with intelligent electronic devices (IEDs), such as protective relays, power meters, and communication switches. Substation engineers commission these IEDs to assess the appropriate measurements for monitoring, control, power system protection, and communication applications. Like real electrical utility substations, complex electrical substation grid testbeds (ESGTs) need to be assessed for measuring current and voltage signals in monitoring, power system protection, control (synchro check), and communication applications that are limited by small measurement percentage errors. In the process of setting an ESGT with real-time simulators and IEDs in the loop, protective relays, power meters, and communication devices must be commissioned before running experiments. In this study, an ESGT with IEDs and distributed ledger technology was developed. The ESGT with a real-time simulator and IEDs in the loop was satisfactorily assessed and commissioned. The commissioning and problem-solving tasks of the testbed are described to define a method with flowcharts to assess possible trouble-shooting in ESGTs. This method was based on comparing the simulations versus IED measurements for the phase current and voltage magnitudes, three-phase phasor diagrams, breaker states, protective relay times with selectivity coordination at electrical faults, communication data points, and time-stamp sources.

Piesciorovsky, Emilio↗

Comparison of free-piston Stirling engine model predictions with RE1000 engine test data

Predictions of a free-piston Stirling engine model are compared with RE1000 engine test data taken at NASA-Lewis Research Center. The model validation and the engine testing are being done under a joint interagency agreement between the Department of Energy's Oak Ridge National Laboratory and NASA-Lewis. A kinematic code developed at Lewis was upgraded to permit simulation of free-piston engine performance; it was further upgraded and modified at Lewis and is currently being validated. The model predicts engine performance by numerical integration of equations for each control volume in the working space. Piston motions are determined by numerical integration of the force balance on each piston or can be specified as Fourier series. In addition, the model Fourier analyzes the various piston forces to permit the construction of phasor force diagrams. The paper compares predicted and experimental values of power and efficiency and shows phasor force diagrams for the RE1000 engine displacer and piston. Further development plans for the model are also discussed.

Tew, R. C., Jr.↗

Comparison of free-piston Stirling engine model predictions with RE1000 engine test data

Predictions of a free-piston Stirling engine model are compared with RE1000 engine test data taken at NASA-Lewis Research Center. The model validation and the engine testing are being done under a joint interagency agreement between the Department of Energy's Oak Ridge National Laboratory and NASA-Lewis. A kinematic code developed at Lewis was upgraded to permit simulation of free-piston engine performance; it was further upgraded and modified at Lewis and is currently being validated. The model predicts engine performance by numerical integration of equations for each control volume in the working space. Piston motions are determined by numerical integration of the force balance on each piston or can be specified as Fourier series. In addition, the model Fourier analyzes the various piston forces to permit the construction of phasor force diagrams. The paper compares predicted and experimental values of power and efficiency and shows phasor force diagrams for the RE1000 engine displacer and piston. Further development plans for the model are also discussed.

Tew, R. C.↗

Suppressing interfering scattered signals in swept-frequency radar measurements by using frequency domain Wiener filtering

A novel approach to the reduction of scattered, interfering signals that corrupt measurements of the signal backscattered from radar targets of interest is being developed. It is being explored with sphere measurements in an indoor microwave radar range. This method is based on the concept of Wiener filtering (which minimizes the difference between the signal plus noise and the desired signal in the time domain). In contrast to the traditional Wiener filter, in which the time domain error between two sequences are minimized, the approach reported uses the frequency domain phasor amplitudes of a swept frequency signal. It minimizes the difference (least-mean-square-magnitude) between the signal-plus-noise and the signal complex phasors, across the entire spectrum.

Weissman, David E.↗

Theory of post-block 2 VLBI observable extraction

The algorithms used in the post-Block II fringe-fitting software called 'Fit' are described. The steps needed to derive the very long baseline interferometry (VLBI) charged-particle corrected group delay, phase delay rate, and phase delay (the latter without resolving cycle ambiguities) are presented beginning with the set of complex fringe phasors as a function of observation frequency and time. The set of complex phasors is obtained from the JPL/CIT Block II correlator. The output of Fit is the set of charged-particle corrected observables (along with ancillary information) in a form amenable to the software program 'Modest.'

Lowe, Stephen T.↗

Power-Domain Impedance Theory for the Analysis and Mitigation of Interarea Oscillations: Preprint

This paper presents an impedance-based theory for the analysis and mitigation of interarea oscillations in power systems. Because low-frequency power system oscillations primarily manifest in phasor quantities, including active and reactive power flows, and the magnitude and frequency of bus voltages, a new-type of impedance, called power-domain impedance, is defined in terms of these phasor quantities. The power-domain impedance provides an intuitive framework for the analysis of interarea oscillations without requiring internal details of generators, and it is ideally suited for developing oscillation damping controls in inverter-based resources. The power-domain impedance theory is demonstrated in this paper using PSCAD simulations of a two-area system. The theory is also used for designing damping control in synchronous generators and a wind power plant in the two-area system.

24 POWER TRANSMISSION AND DISTRIBUTION↗