Search NASA⌕ Search

SEARCH · Search NASA

Results for “piezoelectric actuation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

86 records · Page 5

Origin of giant electric-field-induced strain in faulted alkali niobate films

A large electromechanical response in ferroelectrics is highly desirable for developing high-performance sensors and actuators. Enhanced electromechanical coupling in ferroelectrics is usually obtained at morphotropic phase boundaries requiring stoichiometric control of complex compositions. Recently it was shown that giant piezoelectricity can be obtained in films with nanopillar structures. Here, we elucidate its origin in terms of atomic structure and demonstrate a different system with a greatly enhanced response. This is in non-stoichiometric potassium sodium niobate epitaxial thin films with a high density of self-assembled planar faults. A giant piezoelectric coefficient of ~1900 picometer per volt is demonstrated at 1 kHz, which is almost double the highest ever reported effective piezoelectric response in any existing thin films. The large oxygen octahedral distortions and the coupling between the structural distortion and polarization orientation mediated by charge redistribution at the planar faults enable the giant electric-field-induced strain. Our findings demonstrate an important mechanism for realizing the unprecedentedly giant electromechanical coupling and can be extended to many other material functions by engineering lattice faults in non-stoichiometric compositions.

36 MATERIALS SCIENCE↗

Ferroelectric materials toward next-generation electromechanical technologies

Ferroelectric materials have been widely used in various electromechanical devices, from ultrasonic transducers and actuators to mechanical energy harvesters. The key performance metrics of these devices, such as sensitivity, efficiency, and bandwidth of ultrasonic transducers, are largely determined by the piezoelectric properties. This Review highlights recent research progress in improving the piezoelectricity of ferroelectric materials and offers potential strategies for further enhancement to meet the ever-increasing demands for high-performance piezoelectric devices and systems. Here, it provides insights into the future development of ferroelectrics to address the increasing demands of emerging applications, including photoacoustic imaging and piezoelectric fans and motors in integrated circuit–enabled electronic devices. Additionally, it emphasizes the need to consider environmental impacts across the entire life cycle of ferroelectrics, from sourcing and manufacturing to usage and disposal.

36 MATERIALS SCIENCE↗

NDE Technology Engineering Program for Hanford DST Non-Visual Volumetric Inspection Technology: Phase II RAVIS Radiation Tolerance Test Report

This test report provides the results of radiation tolerance robustness testing that was performed on samples of robotic components and an ultrasonic guided wave air-slot sensor that represent components/sub-systems of the Robotic Air-slot Volumetric Inspection System (RAVIS) that has been engineered for volumetric inspection of Hanford tank bottom plates via under-tank refractory pad air-slots. The specific components tested for 1) functionality during active irradiation and 2) tolerance to cumulative radiation dose (until failure or upon reaching a cumulative dose test limit) were: • four samples each of a printed circuit board (PCB) and direct current (DC) motor, which are robotic components, and • 26 ultrasonic piezoelectric elements (samples) inside an air-slot sensor. The robotic components are part of the RAVIS air-slot inspection crawler drive control system that is responsible for remote communication with and actuation of the air-slot inspection crawler. The failure of either of these components during under-tank deployment would require manual retrieval via the crawler’s tether, which risks damage to the robot/refractory/tank. Preemptive replacement of the components at appropriately conservative dose/time intervals informed by failure dose would reduce the likelihood of under-tank failure. The components were included in radiation tolerance testing to quantify their failure doses to inform replacement intervals. The air-slot sensor is responsible for collecting ultrasonic inspection data (scan images) for the tank bottom plates during under-tank deployment. Compromised signal quality due to elevated noise levels caused by gamma radiation would compromise inspection performance. The air-slot sensor was included in radiation tolerance testing to quantify the impact of active irradiation on sensor signal quality. The irradiation and in-situ functional tests of the PCBs, DC motors and air-slot sensor took place in June and July 2020 at the Pacific Northwest National Laboratory. Testing was performed at a gamma dose rate near 300 rad/hr., which, in the absence of under-tank dose rate data, has been conservatively estimated to be the upper-bound dose rate beneath the primary tanks at Hanford. Irradiation took place at elevated temperatures of 150-200°F to determine failure doses that reflect the compounding effects of gamma radiation and heat. The test results revealed: • The DC motors can tolerate being actively irradiated at the high dose rate at 200°F and can tolerate a cumulative dose of 300,000 rad, that which would be incurred after 5 years of service at the 300 rad/hr dose rate. The component therefore meets minimum and preferred radiation tolerance and lifecycle requirements for robotic components. • The air-slot sensor can tolerate being actively irradiated at the high dose rate at 150°F and can tolerate a cumulative dose of 60,000 rad, that which would be incurred after 1 year of service at the 300 rad/hr dose rate. The sensor therefore meets minimum radiation tolerance and lifecycle requirements. • The PCB can tolerate being actively irradiated at the high dose rate, but can only tolerate a cumulative dose of 19,000 rad at 150-200°F. The PCB does not meet minimum radiation tolerance and lifecycle requirements; however, because the component is considered replaceable, it can be replaced before a cumulative dose of 19,000 rad is reached, determined through either monitoring with a dosimeter or scheduled time intervals that are calculated based on conservative estimates of under-tank dose rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design of a double-sided laser heating compatible piezoelectrically driven dynamic diamond anvil cell

Piezoelectrically driven dynamic diamond anvil cells are generally limited to use at room temperature due to spatial conflicts with the optical components necessary for double-sided laser heating. Here, this work describes the design of a double-sided laser-heating-compatible, piezoelectrically driven dynamic diamond anvil cell (LH-dDAC) that expands the range of experimentally accessible compression rate/temperature space. By developing a spatially in-parallel design, in which the diamond anvils and the piezo actuators lie alongside each other, the total length of the apparatus is reduced to 66.5 mm. The new LH-dDAC is capable of probing both overpressure and compression-rate effects on the kinetics of phase transitions. We illustrate the capability of the new LH-dDAC using the following cases: (1) a simultaneous pressure and temperature jump from 19.5 GPa and room temperature to 40 GPa and ≈1550 K and (2) a controlled compression ramp at ≈1850 K and ≈100 GPa/s. By pairing rapid compression with laser heating, the new LH-dDAC opens the door to studies of diffusionally controlled transformations at high pressures and temperatures.

Copley, J. A. [Princeton Univ., NJ (United States)↗

TEAMER: Electrically Engaged Undulation System for Unmanned Underwater Vehicles

This TEAMER RFTS 1 (Request for Technical Support) project supported the flume tank testing of a long range, high endurance unmanned underwater vehicle (UUV) to monitor maritime space. Today, battery-powered remotely operated vehicles (ROVs) lack the duration to make persistent, wide-area data collection possible.The proposed solution, an Electrically Engaged UnduLation (EEL) drone, can sustain missions for longer duration through hydrodynamic energy harvesting. Power is provisioned via the piezoelectric effect, a material-led phenomenon that converts applied stress into electricity. The EEL subsystems include power, propulsion, navigation, ballast, telemetry, and instrumentation. By mimicking the gait of aquatic eels, EEL can counter currents during maneuvering and level-flight. The identified opportunity is in the future capability of extreme endurance UUVs in swarms. The specific goal for the EEL development is to expand the spatio-temporal coverage of the existing ocean observation mission by overcoming significant challenges of autonomous robotics. Some of the challenges presented include novel compliant mechanism for robust actuation, bio-inspired design to emulate efficient locomotion, smart material-based energy harvesting for sustained power, and swarming architecture through enabled autonomy.

16 TIDAL AND WAVE POWER↗

Synthesis of LaWN 3 nitride perovskite with polar symmetry

Perovskite structured materials have a variety of uses as photovoltaics, capacitors, and micromechanical actuators, along with other applications. Oxides, halides, and chalcogenides all have large numbers of perovskite structured materials. Examples of perovskite nitrides are conspicuously absent, but Talley et al managed to synthesize one (see the Perspective by Hong). Lanthanum tungsten nitride in the perovskite structure turns out to be piezoelectric, which is ideal for a variety of applications. Perovskite structured nitrides are very attractive because they could easily integrate with the large number of nitride-based semiconducting devices already in use.

36 MATERIALS SCIENCE↗

Tandem neural network-based controller for x-ray bimorph mirrors

Nanometer-scale shape control of x-ray mirrors is crucial for coherent x-ray beam experiments at low-emittance synchrotron beamline instruments. Piezoelectric bimorph mirrors offer adaptive control but are hindered by nonlinearities such as cross talk, creep, and hysteresis. To overcome these limitations, we present a novel feedback-free control solution, inspired by the proportional–integral–derivative (PID) scheme, driven by tandem neural networks (TNNs). Using task-specific datasets, the TNN-based system predicts actuator voltages with greater speed, accuracy, and stability than a single NN-based model. This approach is ideal for real-time applications, such as adapting beam focus to dynamic sample sizes while maintaining precise wavefront quality. Our findings highlight the potential of artificial intelligence in rapidly optimizing adaptive optics and managing nonlinear control systems.

Zhang, Runyu↗

On the Bandwidth and Beam Profile Characteristics of a Simple Low-Frequency Collimated Ultrasound Beam Source

We numerically investigate the bandwidth and collimation characteristics of ultrasound beams generated by a simple collimated ultrasound beam source that consists of a piezoelectric disk operated near its radial mode resonances. We simulate the ultrasound beam generated in a fluid medium as a function of the excitation frequency for two cases: (1) free piezoelectric disk that corresponds to zero-traction along the lateral edge and (2) fixed piezoelectric disk that corresponds to zero-displacement along the lateral edge. We present and discuss the physical mechanism underpinning the frequency-dependent collimation and bandwidth properties of the ultrasound beams. We observe that the collimated beam generated by the free disk repeatedly lengthens/shortens and also extends/retracts sidelobes with increasing frequency. Alternatively, fixing the piezoelectric disk results in a consistent beam profile shape across a broad range of frequencies. This facilitates generating broadband signals such as a Gaussian pulse or chirp, which are common in ultrasound imaging. Thus, the fixed piezoelectric disk finds application as a collimated ultrasound beam source in a wide range of applications including medical ultrasound imaging, scanning acoustic microscopy, sonar detection, and other nondestructive ultrasound inspection techniques.

47 OTHER INSTRUMENTATION↗

Tip-based proximity ferroelectric switching and piezoelectric response in wurtzite multilayers

Proximity ferroelectricity is a paradigm for inducing ferroelectricity when a nonferroelectric polar material (such as Al⁢ N), which is unswitchable with an external field below the dielectric breakdown field, becomes a practically switchable ferroelectric in direct contact with a thin switchable ferroelectric layer (such as Al 1−𝑥 ⁢Sc 𝑥 ⁢N). Here, we develop a Landau-Ginzburg-Devonshire approach to study the proximity effect of local piezoelectric response and polarization reversal in wurtzite ferroelectric multilayers under a sharp electrically biased tip. Using finite-element modeling, we analyze the probe-induced nucleation of nanodomains, the features of local polarization hysteresis loops and coercive fields in the Al 1−𝑥 ⁢Sc 𝑥 ⁢N/Al⁢ N bilayers and three-layers. Similar to the wurtzite multilayers sandwiched between two parallel electrodes, the regimes of “proximity switching” (when all layers collectively switch) and the regime of “proximity suppression” (when they collectively do not switch) are the only two possible regimes in the probe-electrode geometry. However, the parameters and asymmetry of the local piezoresponse and polarization hysteresis loops depend significantly on the sequence of the layers with respect to the probe. The physical mechanism of proximity ferroelectricity in the local probe geometry is a depolarizing electric field determined by the polarization of the layers and their relative thickness. The field, whose direction is opposite to the polarization vector in the layer(s) with the larger spontaneous polarization (such as Al⁢ N), renormalizes the double-well ferroelectric potential to lower the steepness of the switching barrier in the “otherwise unswitchable” polar layers. Tip-based control of domains in otherwise nonferroelectric layers using proximity ferroelectricity can provide nanoscale control of domain reversal in memory, actuation, sensing, and optical applications. The ability of the tip-induced proximity switching to differentially switch multilayers, based on the order of the layers, provides a powerful tool for selective domain engineering.

36 MATERIALS SCIENCE↗

GaN Core-shell Nanofin Vertical Transistor (CoNVerT): A New Direction for Power Electronics (Final Scientific/Technical Report)

A novel power transistor architecture, the GaN c ore-shell n anofin ver tical transistor (CoNVerT) to address fundamental challenges in realizing the ultimate limit of GaN power transistor performance was explored experimentally. This technology promises ultra-high-efficiency high voltage/high power applications (e.g. DC/DC converters, motor control, fast charging, actuation), as well as to operate in harsh environments. The device exploits a vertical superjunction structure based on an experimentally-validated core-shell nanofin growth process in which lateral p-n heterojunctions are formed in a single growth step, while still maintaining vertical current flow for compact die size and low cost. The concept leverages the best properties of GaN for mid-range voltage applications: high mobility, high breakdown voltage, and native heterojunction enhancement-mode operation. Due to the crystallographic nature of the nanofin growth by molecular beam epitaxy, the sidewall heterojunctions occur on non-polar planes, resulting in ultra-smooth interfaces for high mobility, no sidewall etch damage and related surface/interface states, and elimination of piezoelectric effects that can limit reliability in conventional structures. This also facilitates superjunction formation for maximum device performance, and the selective-area growth of the nanofin results in dislocation-free growth, even on low-cost Si (111) substrate. In this program, core-shell nanofins were grown by molecular beam epitaxy, test structures to evaluate the doping, resistivity, and other electrical properties were fabricated, and the material and test structures were characterized in detail. The work identified clear potential (e.g., the doping was well controlled as required for superjunction concepts), but also additional areas that require additional effort to resolve (some unexpected crystal defects were encountered that require additional engineering to overcome). Simulation studies of the proposed concept validate that the fundamental approach is very promising, but additional effort in experimental realization is needed.

42 ENGINEERING↗

Ink-based laser powder bed fusion of barium titanate

Barium titanate (BTO) is a lead-free functional ceramic that is widely used in sensors, transducers, and actuators. The increasing demand for complex geometries and quick design iterations motivates the use of additive manufacturing techniques. Laser powder bed fusion (L-PBF) additive manufacturing technique enables the net-shape or near-net-shape fabrication of metals and alloys. Ceramic L-PBF remains challenging due to their high melting temperature. Here, to address this challenge, a nanoparticle ink feedstock was incorporated into the L-PBF process to allow low power melting of BTO. Key print parameters (i.e. laser power, scanning speed, and hatching spacing) were optimized to fabricate millimeter-scale BTO parts. The printed BTO samples possessed an inhomogeneous equiaxed-columnar-cellular microstructure. Semiconducting current-voltage behavior was observed in as-printed samples, which was attributed to the creation of oxygen vacancies. The piezoelectric d 33 coefficient was measured to be 4.6 pC/N.

Dielectrics↗

Imaging of voltage-controlled switching of magnetization in highly magnetostrictive epitaxial Fe–Ga microstructures

The magnetoelectric behavior of epitaxial Fe–Ga microstructures on top of a (001)-oriented PMN–PT piezoelectric substrate is imaged with magnetic X-ray microscopy. Additionally, the micron-scale strain distribution in PMN–PT is characterized by X-ray microdiffraction and examined with respect to the results of the Fe–Ga magnetoelectric switching. The magnetic reorientation of Fe–Ga is found to be strongly correlated with size, shape, and crystallographic orientation of the microstructures. In the case of square-shaped structures, size dictates the influence of the strain distribution on both the initialization of the ground state and on the magnetic reorientation during application of voltage. On the other hand, elliptical microstructures demonstrate completely different magnetic responses depending on the relative orientation of their long axis with respect to the crystallographic directions of the PMN–PT. This study demonstrates that engineering the behavior of highly magnetostrictive epitaxial microdevices is possible. It further elucidates that voltage-induced actuation can be largely tuned to achieve the desired type of magnetic switching ranging from vortex circulation reversal, domain wall motion, to a large rotation of magnetization. Because of the outstanding properties of the investigated material system, the reported findings are expected to be of great interest for the realization of next-generation energy-efficient magnetic memory and logic devices.

42 ENGINEERING↗

Enhanced piezoelectricity from highly polarizable oriented amorphous fractions in biaxially oriented poly(vinylidene fluoride) with pure β crystals

Piezoelectric polymers hold great potential for various electromechanical applications, but only show low performance, with |d 33 |< 30 pC/N. We prepare a highly piezoelectric polymer (d 33 = -62 pC/N) based on a biaxially oriented poly(vinylidene fluoride) (BOPVDF, crystallinity = 0.52). After unidirectional poling, macroscopically aligned samples with pure β crystals are achieved, which show a high spontaneous polarization (P s ) of 140 mC/m 2 . Given the theoretical limit of P s,β = 188 mC/m 2 for the neat β crystal, the high P s cannot be explained by the crystalline-amorphous two-phase model (i.e., P s,β = 270 mC/m 2 ). Instead, we deduce that a significant amount (at least 0.25) of an oriented amorphous fraction (OAF) must be present between these two phases. Experimental data suggest that the mobile OAF resulted in the negative and high d 33 for the poled BOPVDF. The plausibility of this conclusion is supported by molecular dynamics simulations.

36 MATERIALS SCIENCE↗

Electrical de-poling and re-poling of relaxor-PbTiO 3 piezoelectric single crystals without heat treatment

Re-poling of unexpected partially depoled piezoelectric materials conventionally needs to be first fully depoled through annealing above their Curie temperature to revive piezoelectric performances. Here, we investigated de-poling and re-poling of Pb(In 1/2 Nb 1/2 )O 3 -Pb(Mg 1/3 Nb 2/3 )O 3 -PbTiO 3 single crystals under electric fields at room temperature. We found that alternating current electric fields with amplitudes near the coercive field at low frequencies (<10 Hz) can be employed to successfully depolarize poled crystals at room temperature. We also demonstrated a reversible polarization switching process with a relaxor-PbTiO 3 single crystal ultrasound transducer without device performance degradations. This experimental observation is supported by phase-field simulation, showing that alternating current electric fields can readily induce de-poling at room temperature, while direct current electric fields induce a transient depoled state only within an uncontrollable short period of time. The findings suggest new strategies for unprecedented in-device tailoring of the polarization states of ferroelectric materials.

36 MATERIALS SCIENCE↗