Search NASA⌕ Search

SEARCH · Search NASA

Results for “plasma crystals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A multi-chord, two-color interferometer using Hilbert transform phase detection for measuring electron density in spheromak plasmas

A new, four-chord, CO 2 /He–Ne heterodyne interferometer has been designed and built for measuring line-averaged plasma density in the HIT-SI3 and subsequent HIT-SIU sustained spheromak devices. The two-color system successfully eliminates vibration-induced errors caused by mirrors that are secured to the vacuum chamber and is able to resolve electron densities ne in the full operating range of 10 18 –10 20 m –3 in both experiments with an integrated error of 4.7 × 10 17 m –2 . Here, data are presented from high toroidal current plasma discharges, showing the time evolution of electron densities n e and j Φ /n e along multiple chords.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray self-emission imaging with spherically bent Bragg crystals on the Z-machine

Here, an x-ray imaging scheme using spherically bent crystals was implemented on the Z-machine to image x rays emitted by the hot, dense plasma generated by a Magnetized Liner Inertial Fusion (MagLIF) target. This diagnostic relies on a spherically bent crystal to capture x-ray emission over a narrow spectral range (<15 eV), which is established by a limiting aperture placed on the Rowland circle. The spherical crystal optic provides the necessary high-throughput and large field-of-view required to produce a bright image over the entire, one-cm length of the emitting column of a plasma. The average spatial resolution was measured and determined to be 18 µm for the highest resolution configuration. With this resolution, the radial size of the stagnation column can be accurately determined and radial structures, such as bifurcations in the column, are clearly resolved. The success of the spherical-crystal imager has motivated the implementation of a new, two-crystal configuration for identifying sources of spectral line emission using a differential imaging technique.

47 OTHER INSTRUMENTATION↗

Low Energy Implantation into Transition-Metal Dichalcogenide Monolayers to Form Janus Structures

Atomically-thin two-dimensional (2D) materials face significant energy barriers for synthesis and processing into functional metastable phases such as Janus structures. Here, in this study, the controllable implantation of hyperthermal species from pulsed laser deposition (PLD) plasmas is introduced as a top-down method to compositionally engineer 2D monolayers. The kinetic energies of Se clusters impinging on suspended monolayer WS 2 crystals were controlled in the <10 eV/atom range with in situ plasma diagnostics to determine the thresholds for selective top layer replacement of sulfur by selenium for the formation of high quality WSSe Janus monolayers at low (300 °C) temperatures, and bottom layer replacement for complete conversion to WSe 2 . Atomic-resolution electron microscopy and spectroscopy in tilted geometry confirm the WSSe Janus monolayer. Molecular dynamics simulations reveal that Se clusters implant to form disordered metastable alloy regions, which then recrystallize to form highly ordered structures, opening the door for low-energy implantation by PLD as a novel method to explore the synthesis of 2D Janus layers and alloys of variable composition.

2D materials↗

Growth of nanostructured molybdenum disulfide (MoS 2 ) thin films on a nanohole-patterned substrate using plasma-enhanced atomic layer deposition (ALD)

Nanostructured molybdenum disulfide (MoS 2 ) thin films were grown on a nanohole-patterned silicon substrate using plasma-enhanced atomic layer deposition. A nanoscale hole-patterned silicon substrate was fabricated for the growth of MoS 2 film using the self-assembly-based nanofabrication method. The nanoscale holes can significantly increase the surface area of the substrate while the formation and growth of nanostructures normally start at the surface of the substrate. Hydrogen sulfide (H 2 S) gas was used as the S source in the growth of molybdenum disulfide (MoS 2 ) while molybdenum (V) chloride (MoCl 5 ) powder was used as the Mo source. The MoS 2 film had a stoichiometric ratio of 1 (Mo) to 2 (S), and had peaks of E 1 2g and A 1g , which represent the in-plane and out-plane vibration modes of the Mo–S bond, respectively. It was found that the MoS 2 film grown in the nanoscale hole, especially at the wall of the hole, has more hexagonal-like structures due to the effects of nanoscale space confinement and the nanoscale interface although the film shows an amorphous structure. Post-growth high-temperature annealing ranging from 800 to 900 °C produced local crystalline structures in the film, which are compatible with those reported by other researchers.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Absolute calibration of the conical crystal configuration of the zinc spectrometer (ZSPEC) at the OMEGA laser facility

In this study, we present the absolute calibration of the conical crystal for the zinc spectrometer (ZSPEC), an x-ray spectrometer at the OMEGA laser facility at the Laboratory for Laser Energetics. The ZSPEC was originally designed to measure x-ray Thomson scattering using flat or cylindrically curved highly oriented pyrolytic graphite crystals centered around Zn He-alpha emission at 9 keV. To improve the useful spectral range and collection efficiency of the ZSPEC, a conical highly annealed pyrolytic graphite crystal was fabricated for the ZSPEC. The conically bent crystal in the Hall geometry produces a line focus perpendicular to the spectrometer axis, corresponding to the detector plane of electronic detectors at large scale laser facilities such as OMEGA, extending the useful range of the spectrometer to 7–11 keV. Further, using data collected using a microfocus Mo x-ray source, we determine important characteristics of ZSPEC such as the dispersion, spatial resolution, and absolute sensitivity of the instrument. A ray-trace model of ZSPEC provides another point of agreement in calculations of the ZSPEC dispersion and crystal response.

47 OTHER INSTRUMENTATION↗

Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing

A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe 44+ , Xe 47+ , and Xe 51+ , based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.

47 OTHER INSTRUMENTATION↗

Single-Crystal X-Ray Spectropolarimetry using Cubic Crystals

Presentation to be given on a virtual conference, December 3, 2020, High-Temperature Plasma Diagnostics. Conference: http://www.cvent.com/events/2020-high-temperatures-conference/event-summary-316fe078c3894ef5ab725d6bbdf69334.aspx

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nucleation of cubic boron nitride on boron-doped diamond via plasma enhanced chemical vapor deposition

Cubic boron nitride (c-BN), with a small 1.4% lattice mismatch with diamond, presents a heterostructure with multiple opportunities for electronic device applications. However, the formation of c-BN/diamond heterostructures has been limited by the tendency to form hexagonal BN at the interface. In this study, c-BN has been deposited on free standing polycrystalline and single crystal boron-doped diamond substrates via electron cyclotron resonance plasma enhanced chemical vapor deposition (ECR-PECVD), employing fluorine chemistry. In situ x-ray photoelectron spectroscopy (XPS) is used to characterize the nucleation and growth of boron nitride (BN) films as a function of hydrogen gas flow rates during deposition. The PECVD growth rate of BN was found to increase with increased hydrogen gas flow. In the absence of hydrogen gas flow, the BN layer was reduced in thickness or etched. The XPS results show that an excess of hydrogen gas significantly increases the percent of sp2 bonding, characteristic of hexagonal BN (h-BN), particularly during initial layer growth. Reducing the hydrogen flow, such that hydrogen gas is the limiting reactant, minimizes the sp2 bonding during the nucleation of BN. TEM results indicate the partial coverage of the diamond with thin epitaxial islands of c-BN. The limited hydrogen reaction is found to be a favorable growth environment for c-BN on boron-doped diamond.

Physics↗

Evolution of glass structure during femtosecond laser assisted crystallization of LaBGeO 5 in glass

Single crystal LaBGeO 5 architecture formed in La 2 O 3 -B 2 O 3 -2GeO 2 glass serves as a model system for understanding of the transformation from glass to single crystal under fs laser irradiation. This transformation is highly sensitive to glass composition, raising the need to understand how the glass structure and composition evolve during crystallization. In this work, micro X-ray absorption spectroscopy and X-ray fluorescence mapping were used to study the glass structure and composition preceding LaBGeO5 crystallization in the region surrounding the single crystal growth front. The results show precipitation of germanium nanoparticles, as well as anisotropic segregation of Ge and La prior to LaBGeO5 crystallization, which are explained assuming electromigration in high fields within the plasma formed by the fs laser irradiation. However, these nanoparticles do not serve as sites for heterogeneous nucleation. Furthermore, the similarity of local structure around Ge in the starting glass and the ultimate crystal appears to enhance the crystallization process.

36 MATERIALS SCIENCE↗

MBE growth and donor doping of coherent ultrawide bandgap AlGaN alloy layers on single-crystal AlN substrates

Single-crystal Aluminum Nitride (AlN) crystals enable the epitaxial growth of ultrawide bandgap Al(Ga)N alloys with drastically lower extended defect densities. Here, we report the plasma-MBE growth conditions for high Al-composition AlGaN alloys on single-crystal AlN substrates. An AlGaN growth guideline map is developed, leading to pseudomorphic Al x Ga 1–x N epitaxial layers with x ~0.6–1.0 Al contents at a growth rate of ~0.3 μm/h. These epitaxial layers exhibit atomic steps, indicating step flow epitaxial growth, and room-temperature band edge emission from ~4.5 to 5.9 eV. Growth conditions are identified in which the background impurity concentrations of O, C, Si, and H in the MBE layers are found to be very near or below detection limits. An interesting Si segregation and gettering behavior is observed at the epitaxial AlGaN/AlN heterojunction with significant implications for the formation and transport of 2D electron or hole gases. Well-controlled intentional Si doping ranging from ~2 × 10 17 to 3 × 10 19 atoms/cm 3 is obtained, with sharp dopant density transition profiles. In Si-doped Al 0.6 Ga 0.4 N epilayers, a room-temperature free electron concentration of ~3 × 10 19 /cm 3 , an electron mobility of ~27 cm 2 /V s, and an n-type resistivity of ~7.5 m Ω cm are obtained. Here, the implications of these findings on electronic and photonic devices on single-crystal AlN substrates are discussed.

36 MATERIALS SCIENCE↗

New Insights into Nonthermal Plasma-Assisted Poly(vinyl alcohol) Depolymerization Catalyzed by TiO 2

Here, in this study, we investigated the solid residual poly(vinyl alcohol) (PVA) and TiO 2 after nonthermal air, CO 2 , and N 2 plasma depolymerization in the absence and presence of TiO 2 . Scanning electron microscopy studies showed the absence of highly viscous tar and carbonaceous residues on the surfaces of PVA and TiO 2 . In the absence of TiO 2 , PVA particles exhibited micron-sized holes on their surfaces, whereas in the presence of TiO 2 , the surface roughness of PVA particles was observed at the submicron scale. These observations suggest that TiO 2 facilitates the even distribution of nonthermal plasma at a submicron scale, leading to a more uniform depolymerization of PVA surfaces. Raman, Fourier transform infrared spectroscopy, and X-ray absorption spectroscopy showed that (i) the surface of residual PVA contains mainly ketone functional groups and less C-H bonds than the pristine PVA and (ii) further confirmed the absence of highly viscous tar and carbonaceous residues on both used TiO 2 and residual PVA. The nuclear magnetic resonance and mass spectroscopy suggested that the PVA is growing back to poly polyvinyl acetate by the esterification reaction, and the ethers are produced by the acetal reaction between PVA and aldehyde. The transmission electron microscopy and X-ray diffraction analysis indicated no major crystal structural change of the TiO 2 catalyst after the plasma reactions. This study demonstrates that nonthermal plasma-assisted depolymerization is a viable alternative to thermal depolymerization, offering the unique advantage of converting polymer wastes into gaseous small organic molecules without generating recalcitrant viscous tar and carbonaceous residues on the surfaces of the polymer and TiO 2 catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recent enhancements in the performance of the Orion high-resolution x-ray spectrometers

During the past few years, the Orion high-resolution x-ray spectrometers have been successful tools for measuring x-ray spectra from plasmas generated in the Orion laser facility. Duplicate spectrometers also operate successfully at the Livermore EBIT-I and SuperEBIT electron beam ion traps for measuring x-ray polarization. We have recently implemented very high-quality, optically bonded, spherically bent quartz crystals to remove the structure in the x-ray image that had been observed in earlier measurements. The structure had been caused by focusing defects and limited the accuracy of our measurements. In this work, we present before and after images that show a drastic improvement. We, furthermore, have implemented a spherically bent potassium acid phthalate (KAP) crystal on one of our spectrometers. The KAP crystal was prepared in a similar fashion, and we present measurements of the N Ly-β and Ne Lyβ lines taken in first- and second-order reflections at 600 and 1200 eV, respectively. These measurements confirm that KAP crystals can be produced at a quality suitable for extending the spectral coverage to wavelengths longer than those accessible by different quartz crystals, especially those that cover the astrophysically important lines of iron.

47 OTHER INSTRUMENTATION↗

In-situ relative calibration of Bragg crystals with Monte Carlo line ratio analysis

X-ray line emission spectra can thoroughly characterize hot plasmas, especially when line shapes and ratios convey distinct aspects of plasma conditions. However, the high spectral resolution required for observing line shapes is often at odds with the large bandwidth required to observe many line ratios across a wide spectral range. One strategy to obtain high spectral resolution over a wide bandwidth is to use multiple crystals with calibrated reflectivity so that line intensities across different crystals can be compared. Here, we explore the use of a low-resolution, wide-bandwidth mica survey spectrometer to infer relative reflectivity of two high-resolution, narrow-bandwidth quartz crystals. Finally, a Monte Carlo error analysis determines comparable x-ray line ratios measured from both spectrometers, resulting in an in situ calibration factor and associated uncertainty for the relative reflectivity of the high-resolution crystals.

47 OTHER INSTRUMENTATION↗

Single-Crystal X-Ray Spectropolarimeter

X-ray spectropolarimetry is a diagnostics technique suitable for measuring intense electron beams and strong magnetic fields in hot, dense plasmas. To increase the accuracy achievable, we investigated the possibility of measuring both orthogonal components of linear polarization simultaneously using a single crystal. We demonstrated experimentally for the first time that crystals with cubic symmetry can be used as polarizing beam splitters. We also found that the polarization-splitting planes in cubic crystals can be accessed in two crystal orientations, a property that can be used to decrease the clutter in polarized spectra. In parallel, we developed a ray-tracing code and are working to add the crystal reflectivity to instrument modeling codes, to help us interpret the spectra and to design spectroscopic and spectropolarimetric instruments. This work is motivated by the need to perform measurements of important quantities in difficult experimental conditions, such as the axial magnetic field at stagnation in magnetized liner inertial fusion loads.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Open‐Air Combustion Synthesis with Rapid Plasma Processing of Large‐Area Transparent Conducting Oxides

A vacuum-free, high-throughput synthesis of indium tin oxide (ITO) via Combustion Oxidation with Rapid Plasma Processing (CORP) utilizes a solution-based exothermic combustion reaction to generate the oxide with tunable control of either amorphous or crystalline phases. A subsequent open-air, forming gas plasma treatment is used to introduce oxygen vacancies and promote crystallization. Here, the evolution of the oxide structure is elucidated by extended X-ray absorption spectroscopy fine structure analysis. Using CORP, fabrication of 300 cm 2 of ITO possessing a champion sheet resistance of 38 Ω sq. −1 , visible transmission of 89%, conductivity stability for over 250 days, roughness < 2nm, and Haacke figure of merit (%T 550nm 10 /R s ) of 0.012 Ω −1 is achieved. Cost modeling of CORP demonstrates up to a 67% reduction in price for TCOs using fully continuous, in-line unit operations compared with vacuum sputtering. The work shows a path toward a low-cost, vacuum-free manufacturing method for TCOs at commercial scales.

42 ENGINEERING↗

Novel dual-reflection design applied for ITER core x-ray spectrometer

Here. a novel dual-reflection configuration is introduced for the International Tokamak Experimental Reactor (ITER) core x-ray spectrometer to fit the allocated space where it will be placed accompanied by moving the detectors backward to reduce the incident radiation dose. The highly oriented pyrolytic graphite, which has a mosaic structure of microscopic crystallites, is chosen for the front reflector motivated by higher x-ray throughput and stronger misalignment tolerance compared to the perfect crystal reflector. In the ITER core x-ray spectrometer, a combination of several reflector-deflected Lines of Sight (LOSs) and a direct LOS is proposed for the first time named X-Ray Crystal Spectroscopy Core (XRCS-Core). The system is optimized to observe lines from externally seeded xenon and the intrinsic tungsten impurity, meeting both port integration needs and measurement requirements. Its spectral performance is simulated using an analytical-raytracing mixed code——XRSA, showing good imaging quality with a spectral resolution higher than 8000. The XRCS-Core system is thought to be applicable in various ITER scenarios through the assessment taking into account the spectrometers’ specifications and the chosen lines’ emissivity in different plasma parameters.

47 OTHER INSTRUMENTATION↗

Plasmon production from dark matter scattering

We present a first calculation of the rate for plasmon production in semiconductors from nuclei recoiling against dark matter. The process is analogous to bremsstrahlung of transverse photon modes, but with a longitudinal plasmon mode emitted instead. For dark matter in the 10 MeV—1 GeV mass range, we find that the plasmon bremsstrahlung rate is 4–5 orders of magnitude smaller than that for elastic scattering, but 4–5 orders of magnitude larger than the transverse bremsstrahlung rate. Because the plasmon can decay into electronic excitations and has characteristic energy given by the plasma frequency ω p , with ω p ≈ 16 eV in Si crystals, plasmon production provides a new signature and method to detect nuclear recoils from sub-GeV dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗