Search NASA⌕ Search

SEARCH · Search NASA

Results for “plasma dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Rethinking radiation effects in materials science using the plasma-focused ion beam

This work demonstrates the viability of using a plasma-focused ion beam (PFIB) as a new platform to carry out radiation effects studies in solids. While materials subjected to irradiation in either nuclear reactors or energetic particle accelerators experience limitations with respect to inaccuracies in both flux measurements and lack of precise control of irradiation areas, we demonstrate a new irradiation technique that allows the exposure of a single specimen in multiple areas, at multiple doses, and in site-specific dependencies - all with flux variations on the order of only 1%. This versatile technique also allows materials to be exposed to significantly higher irradiation dose rates than conventional accelerators. To validate the new methodology, we selected the classical example of ion-beam-induced amorphization of pure single-crystal Si. By pioneering the use of the PFIB for radiation effects studies in materials science, we were able to exploit, in both micro- and nanometer-sized detail, the differences in electron image contrast arising from crystalline versus amorphous solid-state phases in classical semiconductors subjected to irradiation, thus providing new insights on amorphization mechanisms. This methodology opens new research frontiers at the fringe of materials science with promising applications beyond the scope of materials at extremes such as in nanopatterning, nanodevices and nanoarchitectonics.

36 MATERIALS SCIENCE↗

Impact of Blast Overpressure on the Pharmacokinetics of Various Antibiotics in Sprague Dawley Rats

ABSTRACT Introduction Combat injuries are complex and multimodal. Most injuries to the extremities occur because of explosive devices such as improvised explosive devices. Blast exposure dramatically increases the risk of infection in combat wounds, and there is limited available information on the best antibiotic treatments for these injuries. We previously demonstrated that mice exposed to blast displayed a delayed clearance of cefazolin from the plasma and liver; further semi-mechanistic modeling determined that cefazolin concentrations in the skin of these mice were reduced. Our objective was to investigate the effects of blast on the pharmacokinetics of antibiotics of different types used for the treatment of combat wounds in the rat model. Materials and Methods Male Sprague Dawley rats were exposed to blast overpressure followed by injection of a bolus of animal equivalent doses of an antibiotic (cefazolin, cefepime, ertapenem, or clindamycin) into the tail vein at 1-hour post-blast exposure. Blood was collected at predetermined time points via repeated sampling from the tail vein. Animals were also euthanized at predetermined time points, at which time liver, kidney, skin, and blood via cardiac puncture were collected. Antibiotic concentrations were determined by ultra-performance liquid chromatography–tandem mass spectrometry. Results Blast-exposed rats exhibited a similar rate of clearance compared to non-blasted rats in the blood, liver, kidney, and skin, which is inconsistent with the data regarding cefazolin in blast-exposed mice. Conclusions Our results in rats do not recapitulate our previous observation of delayed cefazolin clearance in mice following the blast overpressure exposure. Although using rats permitted us to collect multiple blood samples from the same animals, rats may not be a suitable model for measuring the pharmacokinetics of antibiotics following blast. The interpretation of the results may be challenging because of variation in data among rat subjects in the same sample groups.

General & Internal Medicine↗

Cr plasma-material-interaction in PISCES-RF: D thermal release, retention, and erosion

Pure chromium (Cr) targets were exposed to high-flux deuterium (D) plasmas in the Pisces-RF linear plasma device, and measurements of D retention, release, and erosion were subsequently performed. Post-exposure D retention was quantified using temperature-programmed desorption on Cr targets irradiated by 50 eV ions over a broad range of exposure temperatures (423–873 K) and ion fluences (3 × 10 24 – 3 × 10 26 m −2 ). The retained D inventory was observed to decrease rapidly with increased exposure temperature, from approximately ∼7 × 10 20 m −2 at ∼ 420 K, to then saturate near ∼ 10 20 m −2 for exposure temperatures above ∼550 K. Separately, at fixed exposure temperature (∼450 K), D retention was found to have only a weak dependence on increasing ion fluence. Lastly, the erosion of Cr in D plasma was investigated for ion impact energies in the range 40 ≤ E i ≤ 250 eV. Erosion was inferred using optical emission spectroscopy (OES) from the ratio of emission lines (Cr I (425.4 nm)/D I (656.1 nm)) measured close to the target. Conversion of the OES yield data to net erosion yield was made with singular ion energy target mass-loss measurements. These net erosion yield data were then further corrected to obtain gross erosion yield by accounting for a re-deposition factor, computed using a simple model. The gross erosion yield is found to be 2–4 times lower than predicted by SDTrimSP, consistent with that typically observed for light-ion sputtering under high-flux plasma conditions.

Chromium↗

Molecular basis for antiviral activity of two pediatric neutralizing antibodies targeting SARS-CoV-2 Spike RBD

Neutralizing antibodies (NAbs) hold great promise for clinical interventions against SARS-CoV-2 variants of concern (VOCs). Understanding NAb epitopedependent antiviral mechanisms is crucial for developing vaccines and therapeutics against VOCs. Here we characterized two potent NAbs, EH3 and EH8, isolated from an unvaccinated pediatric patient with exceptional plasma neutralization activity. EH3 and EH8 cross-neutralize the early VOCsandmediatestrong Fc-dependent effector activity in vitro. Structural analyses of EH3 and EH8 in complex with the receptor-binding domain (RBD) revealed the molecular determinantsoftheepitope-drivenprotectionandVOCevasion.WhileEH3represents the prevalent IGHV3-53 NAb whose epitope substantially overlaps with the ACE2 binding site, EH8 recognizes a narrow epitope exposed in both RBD-up and RBD-down conformations. When tested in vivo, a single-dose prophylactic administration of EH3 fully protected stringent K18-hACE2 micefrom lethal challenge with Delta VOC. Our study demonstrates that protective NAbs responses converge in pediatric and adult SARS-CoV-2 patients.

60 APPLIED LIFE SCIENCES↗

Evidence for anti-synergism between ion-assisted etching and in-plasma photoassisted etching of silicon in a high-density chlorine plasma

Etching of p-Si in 60 mTorr 10%Cl2/90%Ar Faraday-shielded inductively coupled high density plasmas was investigated under both ionassisted etching (IAE) and photoassisted etching (PAE) conditions. Real-time etching rates and after-etching Si surface chemical compositions were obtained by laser interferometry and vacuum-transfer x-ray photoelectron spectroscopy (XPS), respectively. Precisely controlled ion energy distributions (IEDs) were generated by applying pulsed negative DC bias on the conductive sample stage. Above a 36 eV threshold at a total flow rate of 250 SCCM, the IAE rate increased with the square root of the ion energy. In contrast to the DC bias, etching under RF bias did not exhibit a threshold ion energy because of the wide IED. XPS spectra revealed that the surface layer under PAE conditions had a significantly lower chlorine content, composed of only SiCl. Under IAE conditions, however, silicon dangling bonds (Si•), SiCl 2 , and SiCl 3 were found on the surface, in addition to SiCl, with a relative abundance of SiCl > SiCl 2 , and SiCl 3 . The absence of higher chlorides and Si• under PAE conditions suggested that vacuum ultraviolet photons and above threshold-energy ions interact with the surface very differently. By varying the duty cycle of the pulsed DC bias, it was found that the IAE rate scaled with the energetic ion dose, but only for low duty cycles. For higher duty cycles, the apparent IAE yield fell off with an increasing Cl coverage on the surface, as the duty cycle went up, which pointed to a negative synergy (antisynergism) between PAE and IAE as the explanation. This antisynergism was further supported by the observed decrease of the total etching rate with an increasing period of the pulsed DC bias. A plausible mechanism is that increasing the pulsing period causes more near-surface damage, creating more recombination centers that lead to a higher loss rate of electron-hole pairs through recombination, thereby reducing the PAE rate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simple thermal vapor deposition process for and characterization of n-type indium oxysulfide thin films

The search continues for alternative nontoxic n-type electron transport layers in optoelectronic thin-film devices. Indium oxysulfide, In 2 (O,S) 3 , represents one promising material for this application, especially when paired with chalcogenide absorber layers. The ternary nature of the composition allows for electrical conductivity and optical bandgap tuning by tailoring the sulfur to oxygen ratio in the oxysulfide alloy. However, thin films of In 2 (O,S) 3 are typically deposited only by chemical bath deposition or plasma-enhanced atomic layer deposition. Here we report deposition of thin films of In 2 (O,S) 3 in a custom-built thermal reactor using only water vapor and hydrogen sulfide as the coreactants. This advance is enabled by the use of a recently reported, highly reactive indium formamidinate precursor. As shown by x-ray photoelectron spectroscopy, the composition can be tuned from pure In 2 (O,S) 3 to pure In 2 S 3 by varying the ratio of cycles employing water or hydrogen sulfide. The oxygen to the sulfur ratio in the film can be controlled by altering the dose sequence, although films typically contain more sulfur than would be expected naively from the percentage of hydrogen sulfide doses in the deposition recipe. Rutherford backscattering spectrometry confirms the composition is sulfur-rich relative to the dosing ratio. Structural characterization indicates films are relatively amorphous in nature. Electrically, these films offer reasonably constant electron mobility at different O:S ratios, with an electron concentration tunable over 4 orders of magnitude. These oxysulfide films possess a higher indirect bandgap than their oxygen-free indium sulfide counterparts, indicating higher transmittance to blue light. These indium oxysulfide films may be suitable candidates for electron transport layers in thin-film solar cells where their wider bandgap might result in higher optical transparency and thus short circuit current density, while the tunability of their conduction band offset with an absorber layer may result in higher open circuit voltage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deletion of Carboxypeptidase E in β-Cells Disrupts Proinsulin Processing but Does Not Lead to Spontaneous Development of Diabetes in Mice

Carboxypeptidase E (CPE) facilitates the conversion of prohormones into mature hormones and is highly expressed in multiple neuroendocrine tissues. Carriers of CPE mutations have elevated plasma proinsulin and develop severe obesity and hyperglycemia. We aimed to determine whether loss of Cpe in pancreatic β-cells disrupts proinsulin processing and accelerates development of diabetes and obesity in mice. Pancreatic β-cell–specific Cpe knockout mice (βCpeKO; Cpe fl/fl x Ins1 Cre/+ ) lack mature insulin granules and have elevated proinsulin in plasma; however, glucose-and KCl-stimulated insulin secretion in βCpeKO islets remained intact. High-fat diet–fed βCpeKO mice showed weight gain and glucose tolerance comparable with those of Wt littermates. Notably, β-cell area was increased in chow-fed βCpeKO mice and β-cell replication was elevated in βCpeKO islets. Transcriptomic analysis of βCpeKO β-cells revealed elevated glycolysis and Hif1α-target gene expression. On high glucose challenge, β-cells from βCpeKO mice showed reduced mitochondrial membrane potential, increased reactive oxygen species, reduced MafA, and elevated Aldh1a3 transcript levels. Following multiple low-dose streptozotocin injections, βCpeKO mice had accelerated development of hyperglycemia with reduced β-cell insulin and Glut2 expression. In conclusion, these findings suggest that Cpe and proper proinsulin processing are critical in maintaining β-cell function during the development of hyperglycemia.

59 BASIC BIOLOGICAL SCIENCES↗

Radiological analysis and transmutation calculation of representative castable nanostructured alloys

In this work, radiological analysis regarding the waste management was performed on two current reduced-activation ferritic-martensitic (RAFM) steels Eurofer 97 and F82H and two castable nanostructured alloys (CNAs) CNA1 and CNA3 using the European DEMO first wall spectrum. CNA1 and CNA3 are a new generation of RAFM steels, which have increased amounts of nanoscale carbonitrides and carbides precipitates, respectively, via small composition modifications. Furthermore, the increased nitrogen in CNA1 leads to higher activity at ≥50 years, and thus to the disposal concern under the current NRC regulation. However, the calculation using Fetter’s evaluation leads to reduced waste disposal rating (WDR) of down to 0.25 depending on the damage dose from ~0.05 wt percent nitrogen in CNA1, and thus less concern on the waste disposal. Contact dose rate after 10 years from the first wall replacement primarily depends on the initial Co and Nb impurity levels. Other added elements, such as V and Si in CNA1 and Ti and Mn in CNA3, do not have significant effect on the specific activity, contact dose rate, or decay heat. Composition limits of CNAs are given based on the shallow burial disposal and materials recycling. In addition, composition evolution of typical precipitates in the CNAs was calculated using the DEMO first wall and the HFIR spectra. Larger transmutation-induced composition evolution occurs in the V/Ta-rich carbonitrides in CNA1 than that in the Ti-rich carbides in CNA3.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

w22_laser_radiography - Laser-Based MeV Radiography

This project seeks to develop novel x-ray sources based on high-power short-pulse lasers with unique advantages, including small spot size, flexible configuration, and tailorable spectra. Kinetic plasma simulations using the VPIC particle in cell code will be performed to support the R&D goals of this project. If successful, this effort will allow LANL to deploy flexible, compact x-ray sources for static tomographic radiography and dynamic multi-axis radiography at our firing sites and facilities such as pRad and U1a. The higher resolution, shorter pulse duration, and tunability of our proposed sources will enable new applications in the weapons program and broader scientific community. This effort advances the LANL FY22 Strategic Investment Plan priority of “[r]adiographic tools for dynamic and static imaging with improved spatial and temporal resolution, sensitivity, and dose.”

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of thermal and radiation induced creep in the dual cooled lead lithium blanket

The creep in recently designed blanket for the fusion nuclear science facility is described by decomposing it into thermal, irradiation and cavity swelling creep. Initial estimates of thermal creep using elastic high temperature rules showed that the recent heat transfer improvements at the first wall (FW) is feasible, and the FW can withstand heat flux of 0.35 MW/m 2 at 3000 hrs without rupture. A viscoplastic model that is based on Norton's power law and relies on Multiphysics coupling of solid mechanics and heat transfer modules is used to capture the inelastic deformation in the blanket. Results showed that the design peak heat flux of 0.25 MW/m 2 produced maximum thermal creep strain of 0.45 % and the relaxation of the thermal stress at the FW. Irradiation creep is prescribed to be proportional to the displacement damage dose and applied stress. The displacements from irradiation creep radially decrease from the FW to the back wall, but the maximum deformation is found at the back wall that is connected to the Helium manifold due to the high stresses at the region. In conclusion, cavity swelling creep is dominant at steady state and combined with radiation creep to produce displacement of about 8 mm at the FW.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of Cell Painting for chemical hazard evaluation in support of screening-level chemical assessments

‘Cell Painting’ is an imaging-based high-throughput phenotypic profiling (HTPP) method in which cultured cells are fluorescently labeled to visualize subcellular structures (i.e., nucleus, nucleoli, endoplasmic reticulum, cytoskeleton, Golgi apparatus / plasma membrane and mitochondria) and to quantify morphological changes in response to chemicals or other perturbagens. HTPP is a high-throughput and cost-effective bioactivity screening method that detects effects associated with many different molecular mechanisms in an untargeted manner, enabling rapid in vitro hazard assessment for thousands of chemicals. Here, 1201 chemicals from the ToxCast library were screened in concentration-response up to ~100 μM in human U-2 OS cells using HTPP. A phenotype altering concentration (PAC) was estimated for chemicals active in the tested range. PACs tended to be higher than lower bound potency values estimated from a broad collection of targeted high-throughput assays, but lower than the threshold for cytotoxicity. In vitro to in vivo extrapolation (IVIVE) was used to estimate administered equivalent doses (AEDs) based on PACs for comparison to human exposure predictions. AEDs for 18/412 chemicals overlapped with predicted human exposures. Phenotypic profile information was also leveraged to identify putative mechanisms of action and group chemicals. Of 58 known nuclear receptor modulators, only glucocorticoids and retinoids produced characteristic profiles; and both receptor types are expressed in U-2 OS cells. Thirteen chemicals with profile similarity to glucocorticoids were tested in a secondary screen and one chemical, pyrene, was confirmed by an orthogonal gene expression assay as a novel putative GR modulating chemical. Most active chemicals demonstrated profiles not associated with a known mechanism-of-action. However, many structurally related chemicals produced similar profiles, with exceptions such as diniconazole, whose profile differed from other active conazoles. Overall, the present study demonstrates how HTPP can be applied in screening-level chemical assessments through a series of examples and brief case studies.

60 APPLIED LIFE SCIENCES↗

Characterization of Self-Magnetic Pinch (SMP) Radiographic Diode Performance on RITS-6 at Sandia National Laboratories

The goals of an electron beam-driven radiographic source are the focusing of high current at high voltage to a minimal spot size with excellent shot-to-shot reproducibility. The Self-Magnetic Pinch (SMP) diode makes use of such an intense electron beam impinging on a high-atomic weight (tantalum) converter, a counter-streaming ion beam to help minimize the spot size, and operation in a magnetic field-free diode region which further encourages small spot size. Through a series of diode development experiments, output voltages up to 12.5 MV and output currents up to 225 kA have been characterized, with resulting spot sizes below ~ few mm. Scaling studies with parameter variation, such as diode aspect ratio and anode-cathode (A-K) gap variation, give systematic validation to what has heretofore been noted anecdotally by other research groups. While the lack of an imbedded magnetic field helps minimize the SMP spot size, a secondary result may be the generation of beam instabilities which can terminate the radiation pulse. There is anecdotal evidence that in-situ DC heating of the diode region can help stabilize the beam pinch. Clear experimental evidence exists that DC heating/RF cleaning results in better control over the counter-streaming ion population. Expanded use of spatial dose-rate detection is shown to yield new insights into electron beam dynamics in the SMP diode. An attendant study of the SMP diode as a load for an Inductive Voltage Adder (IVA) driver leads to insights into the behavior of the IVA-SMP diode configuration, viewed as a total system, and yields constraints on the overall impedance behavior of the SMP diode load.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Online charge measurement for petawatt laser-driven ion acceleration

Laser-driven ion beams have gained considerable attention for their potential use in multidisciplinary research and technology. Preclinical studies into their radiobiological effectiveness have established the prospect of using laser-driven ion beams for radiotherapy. In particular, research into the beneficial effects of ultrahigh instantaneous dose rates is enabled by the high ion bunch charge and uniquely short bunch lengths present for laser-driven ion beams. Such studies require reliable, online dosimetry methods to monitor the bunch charge for every laser shot to ensure that the prescribed dose is accurately applied to the biological sample. In this paper, we present the first successful use of an Integrating Current Transformer (ICT) for laser-driven ion accelerators. This is a noninvasive diagnostic to measure the charge of the accelerated ion bunch. It enables online estimates of the applied dose in radiobiological experiments and facilitates ion beam tuning, in particular, optimization of the laser ion source, and alignment of the proton transport beamline. We present the ICT implementation and the correlation with other diagnostics, such as radiochromic films, a Thomson parabola spectrometer, and a scintillator.

47 OTHER INSTRUMENTATION↗

Scalings of laser-driven MeV electron sources with relativistic multi-picosecond laser pulses

We investigate the generation of MeV electrons in relativistic multi-picosecond laser–solid interactions, using two-dimensional particle-in-cell simulations. Scanning a parameter space of intensities from 10 18 to 10 20 W/cm 2 and pulse durations between 100 fs and 10 ps, we discuss scalings of the effective hot electron temperature and MeV electron dose relevant to applications, as well as the direct laser acceleration mechanism that drives electrons to energies much higher than the ponderomotive potential of the laser pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An atom probe tomography and inventory calculation examination of second phase precipitates in neutron irradiated single crystal tungsten

Tungsten is the prime candidate material for the plasma facing divertor system and first wall armor of future nuclear fusion reactors. However, the understanding of the microstructural and chemical evolution of pure tungsten under neutron irradiation is relatively unknown, in part due to a lack of experimental data on this topic. Here, single crystal tungsten has been irradiated in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory at a nominal temperature of 700–800 °C to damage levels of 0.1 and 1.8 displacements per atom (dpa). Inventory calculations of the neutron irradiation experiments have been used to track isotope generation and decay to inform atom probe tomography (APT) results in the determination of the transmutation-induced precipitate compositions. Furthermore, APT crystallography has been used to show the relationship between precipitates and matrix. The composition of the precipitates is shown to progress towards that of the σ-phase at the highest dose studied, with those precipitates lying along crystallographic planes similar to those of displacement-induced dislocations. This work also sets the framework for APT studies of materials that contain isotopic ratios far from those observed in the natural state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Novel dual-reflection design applied for ITER core x-ray spectrometer

Here. a novel dual-reflection configuration is introduced for the International Tokamak Experimental Reactor (ITER) core x-ray spectrometer to fit the allocated space where it will be placed accompanied by moving the detectors backward to reduce the incident radiation dose. The highly oriented pyrolytic graphite, which has a mosaic structure of microscopic crystallites, is chosen for the front reflector motivated by higher x-ray throughput and stronger misalignment tolerance compared to the perfect crystal reflector. In the ITER core x-ray spectrometer, a combination of several reflector-deflected Lines of Sight (LOSs) and a direct LOS is proposed for the first time named X-Ray Crystal Spectroscopy Core (XRCS-Core). The system is optimized to observe lines from externally seeded xenon and the intrinsic tungsten impurity, meeting both port integration needs and measurement requirements. Its spectral performance is simulated using an analytical-raytracing mixed code——XRSA, showing good imaging quality with a spectral resolution higher than 8000. The XRCS-Core system is thought to be applicable in various ITER scenarios through the assessment taking into account the spectrometers’ specifications and the chosen lines’ emissivity in different plasma parameters.

47 OTHER INSTRUMENTATION↗

NSUF RTE completion report for 23-4780: Microstructural Defect Induced Thermal Conductivity Reduction in Uranium Nitride and Thorium Nitride

Uranium nitride (UN) is known to have a higher thermal conductivity than traditional oxide fuels, which could lead to a more efficient energy transport and lower local temperature during its lifetime. But the thermal transport performance of UN in extreme environments has not been systematic studied. This study investigated the irradiation induced microstructural defects in UN and the impacts on thermal conductivity. The samples were produced by spark plasma sintering at University of Texas-San Antonio (UTSA), Los Alamos National Laboratory (LANL), and Idaho National Laboratory (INL). Thermal conductivity of UN before and after 2MeV proton irradiation were measured by using laser metrology at INL in a temperature range of 77-295K. Thermal conductivity measurements in this wide, cryogenic temperature range is critical to understand the phonon scattering mechanisms between the thermal energy carrier, phonons, and different types of irradiation-induced defects. In order to ensure the measurements were conducted in the same grains and minimize the impact of the local heterogeneities, the measurement locations were highlighted by fiducial marks using the focused ion beam (FIB) with grain orientation identified using the electron backscatter diffraction (EBSD) at the Center of Advanced Energy Studies (CAES). Irradiation experiment was conducted at the Ion Beam Laboratory at Texas A&M University (TAMU). A total of 6 samples were irradiated with different irradiation doses and temperatures. After irradiation, the microstructure was characterized by using Transmission Electron Microscope (TEM) at CAES (also in the FIB marks).

36 - MATERIALS SCIENCE↗

Thermal diffusivity recovery and defect annealing kinetics of self-ion implanted tungsten probed by insitu transient grating spectroscopy

Tungsten is a promising candidate material for plasma-facing armour components in future fusion reactors. A key concern is irradiation-induced degradation of its normally excellent thermal transport properties. In this comprehensive study, thermal diffusivity degradation in ion-implanted tungsten and its evolution from room temperature (RT) to 1073 K is considered. Five samples were exposed to 20 MeV self-ions at RT to achieve damage levels ranging from 3.2 x 10 -4 to 3.2 displacements per atom (dpa). Transient grating spectroscopy with in-situ heating was then used to study thermal diffusivity evolution as a function of temperature. Using a kinetic theory model, an equivalent point defect density is estimated from the measured thermal diffusivity. The results showed a prominent recovery of thermal diffusivity between 450 K and 650 K, which coincides with the onset of mono-vacancy mobility. After 1073 K annealing samples with initial damage of 3.2 x 10 -3 dpa or less recover close to the pristine value of thermal diffusivity. For doses of 3.2 x 10 -2 dpa or higher, on the other hand, a residual reduction in thermal diffusivity remains even after 1073 K annealing. Transmission electron microscopy reveals that this is associated with extended, irradiation-induced dislocation structures that are retained after annealing. A sensitivity analysis shows that thermal diffusivity provides an efficient tool for the assessing total defect content in tungsten up to 1000 K.

36 MATERIALS SCIENCE↗