Search NASA⌕ Search

SEARCH · Search NASA

Results for “point of care”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Assessing the Added Value of Miniature X-Ray in the Setting of US in Spaceflight

INTRODUCTION: Point-of-care ultrasound (POCUS) has become the standard of care for imaging diagnosis and management in lowEarth Orbit (LEO) spaceflight and it has long been hypothesized that POCUS will also be the standard of care for exploration spaceflight. However, like the trajectory for which ultrasound became more portable and user-friendly, the mass, volume, and power requirements of radiography devices for both diagnostic and therapeutic applications have also been dramatically reduced. This study seeks to determine the clinical utility and added value of miniature x-ray (XR) for the diagnosis and management of each of the 119 conditions within NASA Exploration Medical Capability’s IMPACT Condition List (ICL) given that the medical system is presumed to already be carrying a handheld portable POCUS device. METHODS: For each condition, a team of reviewers performed a rapid systematic literature review seeking sensitivity and specificity data for both handheld portable ultrasound and miniature XR. When there was a paucity of data, subject matter expertise and clinical experience was added to semi-quantitatively score the added value of miniature XR, given an US was already available for both diagnosis and management. Diagnostic utility of a modality for a condition was evaluated in the setting of both the best- and worst-case scenario definitions included and defined by the ICL. Evidence tracing and quality of evidence scores were also recorded. RESULTS/DISCUSSION: Conditions for which it was determined that miniature XR added diagnostic or therapeutic value are provided in this presentation. Previously presented work by our team has demonstrated that XR provides diagnostic and management capabilities that are hypothesized to complement or surpass ultrasound for over one-third of medical conditions that may arise during exploration spaceflight (i.e., diagnosis of injuries to the axial skeleton, teeth, and lungs as well as management of orthopedic reductions, endotracheal tube placement, and drain placement confirmation). In the setting of known inclusion of a handheld portable POCUS device, there remains significant added value of portable miniature XR. Whether or not this added clinical benefit is worth the mass, volume, and power requirements of the radiography system remains yet unknown and is the focus of future work. LEARNING OBJECTIVES: 1) Understand the value of ultrasound and radiography in the diagnosis and management of medical comorbidities that may arise in exploration spaceflight; 2) Understand the medical conditions of highest concern on exploration class missions for which miniature x-ray may provide added value to portable ultrasound.

Jon Steller↗

Low-Cost and Portable Biosensor Based on Monitoring Impedance Changes in Aptamer-Functionalized Nanoporous Anodized Aluminum Oxide Membrane

We report a low-cost, portable biosensor composed of an aptamer-functionalized nanoporous anodic aluminum oxide (NAAO) membrane and a commercial microcontroller chip-based impedance reader suitable for electrochemical impedance spectroscopy (EIS)-based sensing. The biosensor consists of two chambers separated by an aptamer-functionalized NAAO membrane, and the impedance reader is utilized to monitor transmembrane impedance changes. The biosensor is utilized to detect amodiaquine molecules using an amodiaquine-binding aptamer (OR7)-functionalized membrane. The aptamer-functionalized membrane is exposed to different concentrations of amodiaquine molecules to characterize the sensitivity of the sensor response. The specificity of the sensor response is characterized by exposure to varying concentrations of chloroquine, which is similar in structure to amodiaquine but does not bind to the OR7 aptamer. A commercial potentiostat is also used to measure the sensor response for amodiaquine and chloroquine. The sensing response measured using both the portable impedance reader and the commercial potentiostat showed a similar dynamic response and detection threshold. The specific and sensitive sensing results for amodiaquine demonstrate the efficacy of the low-cost and portable biosensor.

60 APPLIED LIFE SCIENCES↗

Measurement of the Landsat Thematic Mapper modulation transfer function using an array of point sources

This paper presents a method for measuring the Thematic Mapper (TM) imaging system point spread function (PSF) using TM imagery or a specially constructed target consisting of a two-dimensional array of approximate point sources of known dimensions and radiometric qualities. The target allows 16 separate point sources to be imaged simultaneously by the TM. The point sources were carefully placed on the ground so that their relative positions were known. Owing to sample-scene phasing, each imaged point source exhibits a different amount of blur in the digital image. The target pixels may then be recombined according to their known relative positions to form a single, sampled, nonaliased imaging system PSF. The modulation transfer function is then obtained as the modulus of the discrete Fourier transform of the PSF.

Rauchmiller, Robert F., Jr.↗

Rapid Detection of the Varicella Zoster Virus

1.Technology Description-Researchers discovered that when the Varicella Zoster Virus (VZV) reactivates from latency in the body, the virus is consistently present in saliva before the appearance of skin lesions. A small saliva sample is mixed with a specialized reagent in a test kit. If the virus is present in the saliva sample, the mixture turns a red color. The sensitivity and specificity emanates from an antibody-antigen reaction. This technology is a rapid, non-invasive, point of-of-care testing kit for detecting the virus from a saliva sample. The device is easy to use and can be used in clinics and in remote locations to quickly detect VZV and begin treatment with antiviral drugs. 2.Market Opportunity- RST Bioscience will be the first and only company to market a rapid, same day test kit for the detection of VZV in saliva. The RST detection test kit will have several advantages over existing, competitive technology. The test kit is self contained and laboratory equipment is not required for analysis of the sample. Only a single saliva sample is required to be taken instead of blood or cerebral spinal fluid. The test kit is portable, sterile and disposable after use. RST detection test kits require no electrical power or expensive storage equipment and can be used in remote locations. 3.Market Analysis- According to the CDC, it is estimated that 1 million cases of shingles occur each year in the U.S. with more than half over the age of sixty. There is a high demand for rapid diagnostics by the public. The point-of-care testing (POCT) market is growing faster than other segments of in vitro diagnostics. According to a July 2007 InteLab Corporation industry report the overall market for POCT was forecast to increase from $10.3 billion in 2005 to $18.7 billion by 2011. The market value of this test kit has not been determined. 4.Competition- The VZV vaccine prevents 50% of cases and reduces neuralgia by 66%. The most popular test detects VZV-specific IgM antibody in blood. Other tests include running a sample in a polymerase chain reaction analyzer, enzyme immunoassay, latex agglutination, indirect fluorescent antibody and fluorescent antibody to membrane antigen assay. These existing tests require laboratory analysis by trained personnel, expensive equipment, invasive procedures and a longer period of time to obtain test results.

Lewis, Michelle P.↗

Computer-aided reliability estimation

Computer-aided reliability estimation (CARE) programs are developed to improve the tools available for estimating the reliability of fault-tolerant systems. A description is presented of a program, called CARE II, which was developed after the first program reported by Mathur (1971). Attention is given to the CARE II reliability model, the CARE II coverage model, and CARE II limitations which are to be rectified in CARE III. It is pointed out that the present coverage model in CARE II is extremely versatile. The major limitation is related to the burden placed on the user to determine the basic parameters from which the coverage calculations are made.

Stiffler, J. J.↗

Records Management: Preserving the Past to Make the Future

As an intern in the Records Management Office at NASA, I have learned the importance of records management and teamwork. I work in building 60 with Kevin Coleman, the Records and Forms Manager and History Officer, and Deborah Demaline, the senior records specialist. Prior to my internship, I had never paid attention to records and their role in operating a business. However, after my first assignment of identifying files and filling out a C-277 form, I realized the importance of preserving each file. Since NASA is a government agency, keeping our records in a safe and easily accessible area is a major priority. As the records have accumulated over the years, and the destruction of records has been put on hold due to the fairly recent tobacco litigation; the amount of NASA s records has been quickly accumulating. Currently, our records are stored at Plum Brook in Sandusky, Ohio. Recently, rain has leaked through the bunkers and caused damage to some of our records boxes. Plum Brook has been experiencing difficulty in finding the funds to repair the damage. NASA Glenn is reluctant to give Plum Brook more money because the staff at the Sandusky site has not shown us a detailed summary of what they are doing with the funds we give them annually. Even though storing our records at Plum Brook comes with little cost, there are plenty other companies that offer a records storage area and a special software database for easy record retrieval. My assignment is to do a feasibility study on these companies to see how they compare in providing the appropriate criteria for NASA Glenn's needs. Other research I am doing is on which companies will allow us to convert our physical records into an electronic database for quicker retrieval and to eliminate the cost of storing our records in a facility altogether. The two studies have required me to not only work closely with the Records Management Department, but also the Information Technology staff. It has been important for me to thoroughly understand the criteria both departments here at NASA Glenn need in order to make the system effective for the entire organization. The interaction that I am experiencing with different organizations within NASA Glenn and the various companies we are looking at has enhanced my communication skills. Without proficient communication skills, it is difficult to seek how each company meets all of NASA's standards. This includes webx conferences, teleconferences, face-to-face meetings, knowing the appropriate time to ask questions, knowing what those appropriate questions are, and most importantly, being a good listener. During the meetings and conferences I attend, I ensure that I understand where each party is coming from and listen carefully to the points people make. In addition to working with the feasibility study, I will later work on a marketing plan to encourage employees to take care in storing their records and learn the importance of the History Office. Also, the department is trying to develop a special presentation for new employees during their orientation. Assisting Deborah Demaline in taking inventory at Plum Brook is another task that must be done to ensure that the records have been properly placed.

Petro, Kathryn↗

Development of Jet Noise Power Spectral Laws

High-quality jet noise spectral data measured at the Aero-Acoustic Propulsion Laboratory (AAPL) at NASA Glenn is used to develop jet noise scaling laws. A FORTRAN algorithm was written that provides detailed spectral prediction of component jet noise at user-specified conditions. The model generates quick estimates of the jet mixing noise and the broadband shock-associated noise (BBSN) in single-stream, axis-symmetric jets within a wide range of nozzle operating conditions. Shock noise is emitted when supersonic jets exit a nozzle at imperfectly expanded conditions. A successful scaling of the BBSN allows for this noise component to be predicted in both convergent and convergent-divergent nozzles. Configurations considered in this study consisted of convergent and convergent- divergent nozzles. Velocity exponents for the jet mixing noise were evaluated as a function of observer angle and jet temperature. Similar intensity laws were developed for the broadband shock-associated noise in supersonic jets. A computer program called sJet was developed that provides a quick estimate of component noise in single-stream jets at a wide range of operating conditions. A number of features have been incorporated into the data bank and subsequent scaling in order to improve jet noise predictions. Measurements have been converted to a lossless format. Set points have been carefully selected to minimize the instability-related noise at small aft angles. Regression parameters have been scrutinized for error bounds at each angle. Screech-related amplification noise has been kept to a minimum to ensure that the velocity exponents for the jet mixing noise remain free of amplifications. A shock-noise-intensity scaling has been developed independent of the nozzle design point. The computer program provides detailed narrow-band spectral predictions for component noise (mixing noise and shock associated noise), as well as the total noise. Although the methodology is confined to single streams, efforts are underway to generate a data bank and algorithm applicable to dual-stream jets. Shock-associated noise in high-powered jets such as military aircraft can benefit from these predictions.

Khavaran, Abbas↗

Influence of point defect accumulation on in-pile thermal conductivity degradation: Fuel rod defect distribution and deviation between in-pile and post irradiation thermal conductivity

As nuclear fuel burn-up increases, its thermal conductivity degrades due to the accumulation of defects that lead to increased phonon scattering rates. This results in a rise in the centerline temperature of the fuel rod, whereby heat generation must be decreased to avoid undesired behavior such as fuel melting and extensive fission gas release. Fuel performance codes are utilized to optimize the fuel's operational conditions; while they are based on established physical principles, their empirical nature limits their predictive capabilities. Recently, an effort has been made to develop predictive fuel performance codes for commonly used nuclear fuels, as well as accelerated qualification of advanced nuclear fuels. In this report, we elaborate on the importance of careful analysis of point defects’ impact on thermal conductivity in fuel performance analysis. Further, a model is presented where point defect concentration is estimated based on Rate Theory modeling and used as input to the Klemens-Callaway model to calculate their contribution to the degradation of thermal conductivity in UO 2 under prototypical irradiation conditions. This analysis suggests that point defect concentration is significant at the rim of the fuel pellet and neglecting this leads to underestimation of the centerline temperature, which may have consequences on fission gas behavior.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Column densities resulting from shuttle sublimator/evaporator operation

The proposed disposal of H2O from the shuttle fuel cell operation by ejecting it in vapor form through a supersonic nozzle at the rate of 100 lb/day has been investigated from the point of view of the possible interference to astronomical experiments. If the nozzle is located at the tail and directed along the shuttle longitudinal axis, the resulting column density will be less than 10 to th 12th power molecules/sq cm at viewing angles larger than 48 deg above the longitudinal axis. The molecules in the trail will diffuse rapidly. The column density contribution from molecules expelled on the previous orbit is 1.3 x 10 to the 8th power molecules/sq cm. This contribution diminishes by the inverse square root of the number of orbits since the molecules were expelled. The molecular backscatter from atmospheric molecules is also calculated. If the plume is directed into the flight path, the column density along a perpendicular is found to be 1.5 x 10 to the 11th power molecules/sq cm. The return flux is estimated to be of the order of 10 to the 12th power molecules/sq cm/sec at the stagnation point. With reasonable care in design of experiments to protect them from the backscatter flux of water molecules, the expulsion of 100 lb/day does not appear to create an insurmountable difficulty for the shuttle experiments.

Naumann, R. J.↗

Vacuum in the wake of space vehicles

Vacuum conditions to be encountered in the wakes of high altitude unmanned space vehicles are calculated in order to demonstrate possibilities for conducting experiments using the high pumping speeds and very high vacuum (down to 10 to the -15th torr) attainable. The flux of ambient particles backscattered by emissions from spacecraft surfaces is modelled for an idealized Long Duration Exposure Facility spacecraft structure in an orbit of 550 km altitude. The total backscattered fluxes are found to be between 3 x 10 to the 4th and 3 x 10 to the 5th per sq cm sec for H and between 10 to the 6th and 10 to the 7th per sq cm sec for He and O, depending on the angle with respect to the wake axis. It is found that the direct ambient hydrogen flux is an order of magnitude greater than the backscattered flux, while the backscattered fluxes of He and O are greater than the direct fluxes. It is pointed out that care should be taken in designing space experiments to enable these theoretical conditions to be met.

Oran, W. A.↗

Experiments in advanced control concepts for space robotics - An overview of the Stanford Aerospace Robotics Laboratory

The Stanford University Aerospace Robotics Laboratory is actively developing and experimentally testing advanced robot control strategies for space robotic applications. Early experiments focused on control of very lightweight one-link manipulators and other flexible structures. The results are being extended to position and force control of mini-manipulators attached to flexible manipulators and multilink manipulators with flexible drive trains. Experimental results show that end-point sensing and careful dynamic modeling or adaptive control are key to the success of these control strategies. Free-flying space robot simulators that operate on an air cushion table have been built to test control strategies in which the dynamics of the base of the robot and the payload are important.

Hollars, M. G.↗

Two approaches to the rapid screening of crystallization conditions

A screening procedure is described for estimating conditions under which crystallization will proceed, thus providing a starting point for more careful experiments. The initial procedure uses the experimental setup of McPherson (1982) which supports 24 individual hanging drop experiments for screening variables such as the precipitant type, the pH, the temperature, and the effects of certain additives and which uses about 1 mg of protein. A second approach is proposed (which is rather hypothetical at this stage and needs a larger sample), based on the isoelectric focusing of protein samples on concentration gradients of common precipitating agents. Using this approach, crystals of concanavalin B and canavalin were obtained.

Mcpherson, Alexander↗

TRMM-Based Merged Precipitation Analyses

This paper describes results of using Tropical Rainfall Measuring Mission (TRMM) information as the key calibration tool in a merged analysis on a 1X1 latitude/longitude monthly scale based on multiple satellite sources and raingauge analyses. The TRMM-based product is compared with surface-based validation data sets and the community-based 20-year Global Precipitation Climatology Project (GPCP)monthly analyses. The TRMM-based merged analysis uses the TRMM information to calibrate the estimates from SSM/I and geosynchronous IR observations and merges those estimates together with the TRMM and gauge information to produce accurate rainfall estimates with the increased sampling provided by the combined satellite information. This TRMM merged analysis uses the combined instrument (Precipitation Radar [PR] and TRMM Microwave Imager [TMI]) retrieval of Haddad as the TRMM estimate with which to calibrate the other satellite estimates. This TRMM Combined instrument (TCI) estimate is shown to produce very similar absolute values to the other main TRMM products. The TRMM and other satellites merged analysis compares favorably to the atoll data set of Morrissey for the months of 1998 with a very small positive bias of 2%. However, comparison with the preliminary results from the TRMM ground validation radar information at Kwajalein atoll in the western Pacific Ocean shows a 26% positive bias. Therefore, absolute magnitudes from TRMM and/or the ground validation need to be treated with care at this point. A month by month comparison of the TRMM merged analysis and the GPCP analysis indicates very similar patterns, but with subtle differences in magnitude. Focusing on the Pacific Ocean ITCZ one can see the TRMM-based estimates having higher peak values and lower values in the ITCZ periphery. These attributes also show up in the statistics, where GPCP>TRMM at low values (below 10 mm/d) and TRMM>GPCP at high values (greater than 15 mm/d). Integrated over the 37N-37S belt for all of 1998 the TRMM value is 3.1 mm/day compared to 2.9 mm/day for GPCP, with the results when confined to ocean being 3.3 and 3.0, respectively. Therefore, TRMM has approximately 10% higher tropical oceanic precipitation than GPCP. Examples of TRMM monthly fields in analysis of geographic and temporal variations will also be discussed. Results for 1998 indicate that TRMM has a different ratio of western Pacific to eastern Pacific rainfall than GPCP, perhaps indicating that TRMM's ability to discern the vertical structure of the rain may lead to better estimates in the eastern Pacific. In addition the rainfall anomalies associated with the '98-'99 ENSO event are shown to be larger with the TRMM results as compared to the GPCP analyses.

Adler, Robert↗

Theory of two-point correlations of jet noise

A large body of careful experimental measurements of two-point correlations of far field jet noise was carried out. The model of jet-noise generation is an approximate version of an earlier work of Ribner, based on the foundations of Lighthill. The model incorporates isotropic turbulence superimposed on a specified mean shear flow, with assumed space-time velocity correlations, but with source convection neglected. The particular vehicle is the Proudman format, and the previous work (mean-square pressure) is extended to display the two-point space-time correlations of pressure. The shape of polar plots of correlation is found to derive from two main factors: (1) the noncompactness of the source region, which allows differences in travel times to the two microphones - the dominant effect; (2) the directivities of the constituent quadrupoles - a weak effect. The noncompactness effect causes the directional lobes in a polar plot to have pointed tips (cusps) and to be especially narrow in the plane of the jet axis. In these respects, and in the quantitative shapes of the normalized correlation curves, results of the theory show generally good agreement with Maestrello's experimental measurements.

Ribner, H. S.↗

Enhanced Laser-Induced Graphene Microfluidic Integrated Sensors (LIGMIS) for On-Site Biomedical and Environmental Monitoring

The convergence of microfluidic and electrochemical biosensor technologies offers significant potential for rapid, in-field diagnostics in biomedical and environmental applications. Traditional systems face challenges in cost, scalability, and operational complexity, especially in remote settings. Addressing these issues, laser-induced graphene microfluidic integrated sensors (LIGMIS) are presented as an innovative platform that integrates microfluidics and electrochemical sensors both comprised of laser-induced graphene. This study advances the LIGMIS concept by resolving issues of uneven fluid transport, increased hydrophobicity during storage, and sensor biofunctionalization challenges. Key innovations include Y-shaped reservoirs for consistent fluid flow, hydrophilic polyethyleneimine coatings to maintain wettability, and separable microfluidic and electrochemical components enabling isolated electrode nanoparticle metallization and biofunctionalization. Multiplexed electrochemical detection of the neonicotinoid imidacloprid and nitrate ions in environmental water samples yields detection limits of 707 nm and 10 -5.4 m with wide sensing ranges of 5–100 µm and 10 -5 –10 -1 m, respectively. Similarly, uric acid and calcium ions are detected in saliva, demonstrating detection limits of 217 nm and 10 -5.3 m with sensing ranges of 10–50 µm, and 10 -5 –10 -2.5 m, respectively. Overall, this biosensing demonstrates the capability of the LIGMIS platform for multiplexed detection in biologically complex solutions, with applications in environmental water quality monitoring and oral cancer screening.

environmental monitoring↗

Conducting polymer-based electrochemical sensors: Progress, challenges, and future perspectives

Conducting polymers are promising due to their unique properties, such as excellent electrical and optical properties, physical and chemical stability, high conductivity, and effective redox properties with high-temperature stability and biocompatibility. Due to these properties, conducting polymers are useful in diverse applications like sensors, batteries, oil industries, biosensors, biomedicines, catalysis, cancer treatment, etc. This review article aims to discuss the recent trends and analysis of conducting polymer-based electrochemical sensors in diverse areas with all required sensor characteristics, such as the derived limit of detection, utilized techniques for the sensing analysis and derived linear dynamic range with the stability of the sensors. Conducting polymers and their nanocomposites-based electrochemical sensors have demonstrated exceptional capabilities towards detecting various biomolecules, heavy metals, pesticides, and viruses like SARS-COV-2. Incorporation of redox mediators, use of conducting hydrogels, and molecular imprinting are promising strategies for better performance of the derived sensor. The article has demonstrated the existing challenges and limitations and provided solutions in the field. In the future, conducting polymers-based electrochemical sensors can be utilized in wearable sensors and integrated with IoT devices for better reach in real-time applications. They can also be made more accessible with precise control and data output by following specific methodologies. Utilizing green and sustainable conducting polymers can be crucial in advancing eco-friendly practices in the future. Conducting polymer-based electrochemical sensors has affectivity in neurochemical and pathogen sensing, which is essential for brain function and mental health.

42 ENGINEERING↗

Large-scale calculations of 𝛽-decay rates and implications for 𝑟-process nucleosynthesis

Nuclear 𝛽 decay is a key element of the astrophysical rapid neutron capture process (𝑟 process). In this work, we present state-of-the-art global 𝛽-decay calculations based on the quantified relativistic nuclear energy density functional theory and the deformed proton-neutron quasiparticle random-phase approximation. Our analysis considers contributions from allowed and first-forbidden transitions. We used two point-coupling functionals with carefully calibrated time-odd terms and isoscalar pairing strength. The new calculations display consistent results for both employed functionals, especially near the neutron drip line, suggesting slower 𝛽 decays past the 𝑁=126 neutron shell closure than in commonly used 𝛽-decay models. The new rates, along with the existing rates based on the recent nonrelativistic global calculations, are found to slow down the synthesis of heavy elements in the 𝑟 process and significantly reduce the contribution of neutron-induced fission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗