Search NASA⌕ Search

SEARCH · Search NASA

Results for “porous polymers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Investigations to improve carbon dioxide control with amine and molecular sieve type sorbers

The optimization trends and operating parameters of an integral molecular sieve bed heat exchanger were investigated. The optimum combination of substrate and coating for the HS-B porous polymer was determined based on the CO2 dynamic capacity in the presence of water vapor. Full size HS-B canister performance was evaluated. An Amine CO2 Concentrator utilizing IR-45 sorber material and available Manned Orbiting Laboratory hardware was designed, fabricated and tested for use as an experiment in the NASA 90-day space simulator test of 1970. It supported four men in the simulator for 71 days out of the 90-day test duration.

Bertrand, J. F.↗

Early detection of disease: The correlation of the volatile organic profiles from patients with upper respiratory infections with subjects of normal profiles

A method is described whereby a transevaporator is used for sampling 60-100 microns of aqueous sample. Volatiles are stripped from the sample either by a stream of helium and collection on a porous polymer, Tenax, or by 0.8 ml of 2-chloropropane and collected on glass beads. The volatiles are thermally desorbed into a precolumn which is connected to a capillary gas chromatographic column for analysis. The technique is shown to be reproducible and suitable for determining chromatographic profiles for a wide variety of sample types. Using a transevaporator sampling technique, the volatile profiles from 70 microns of serum were obtained by capillary column gas chromatography. The complex chromatograms were interpreted by a combination of manual and computer techniques and a two peak ratio method devised for the classification of normal and virus infected sera. Using the K-Nearest Neighbor approach, 85.7 percent of the unknown samples were classified correctly. Some preliminary results indicate the possible use of the method for the assessment of virus susceptibility.

Zlatkis, A.↗

Solid-Sorbent Air Sampler

Portable unit takes eight 24-hour samples. Volatile organic compounds in air collected for analysis by portable, self-contained sampling apparatus. Sampled air drawn through sorbent material, commercial porous polymer of 2, 3-diphenyl-p-phenylene oxide. High-boiling-point organic compounds adsorbed onto polymer, while low-boiling-point organics pass through and returned to atmosphere. Sampler includes eight sample tubes filled with polymeric sorbent. Organic compounds in atmosphere absorbed when air pumped through sorbent. Designed for checking air in spacecraft, sampler adaptable to other applications as leak detection, gas-mixture analysis, and ambient-air monitoring.

Galen, T. J.↗

Evaluation of Fungal Metabolic Compounds Released to the Air in a Restricted Environment

The metabolic action of selected fungi species on common components of the interior of Space Station Freedom (SSF) will be tested. When present, volatile organic chemicals will be collected on porous polymer adsorbent columns. Using thermal desorption, the volatile compounds will be passed onto a gas chromatographic column for analysis. The Space Station Freedom (SSF) modular complex will largely be individually self contained and the established air environment will not be easily adjusted. The development and maintenance of a safe working environment offers a considerable challenge. Present plans for use of SSF acknowledge periods of manned activities and alternate times when the station is unmanned. The obvious necessity for clean and safe air and water during periods of use have been pursued as fundamental systems to SSF success. Somewhat less obvious, although perhaps of no less importance to the success of long term cyclic usage, are those periods of inactivity. It is during these periods when spores from microorganisms may be afforded the best conditions to germinate and in the vegetative form react with the complex synthetic chemical polymers which compose the furnishings and hardware of SSF nodes. Biodegradation could constitute a real hygiene problem, if the organisms form and release volatile organic chemicals. Similar problems have been documented in closed and improperly ventilated buildings and work spaces. Many of the metabolic products of fungi and bacterial growth create a variety of health problems. Analytical chemical techniques will first be used to document the growth of Aspergillus, Penicillium, and Cladosporium fungal species on the potential substrates Nomex and Kevlar. Any volatile organics that are released will be measured using the spectrum of gas adsorption chromatography. The level of microbial contamination that is necessary to produce such volatile compounds and the relative amounts expected to accumulate will be estimated.

Ferebee, Robert N.↗

Measuring surface-area-to-volume ratios in soft porous materials using laser-polarized xenon interphase exchange nuclear magnetic resonance

We demonstrate a minimally invasive nuclear magnetic resonance (NMR) technique that enables determination of the surface-area-to-volume ratio (S/V) of soft porous materials from measurements of the diffusive exchange of laser-polarized 129Xe between gas in the pore space and 129Xe dissolved in the solid phase. We apply this NMR technique to porous polymer samples and find approximate agreement with destructive stereological measurements of S/V obtained with optical confocal microscopy. Potential applications of laser-polarized xenon interphase exchange NMR include measurements of in vivo lung function in humans and characterization of gas chromatography columns.

Non-NASA Center↗

Wavenumber-frequency Spectra of Pressure Fluctuations on a Generic Space Vehicle Measured via Unsteady Pressure-Sensitive Paint

Time histories of pressure fluctuations on a generic, hammerhead space vehicle model were measured using unsteady Pressure-Sensitive Paint (uPSP). The test was conducted in the 11-foot transonic wind tunnel of NASA Ames Research Center over a Mach number range of 0.6 M 1.2, and angles of attack of -4 4. The model was coated with a porous binder and PtTFPP-based porous polymer paint. An elaborate system of four high-speed cameras, and forty LED lamps was used for image acquisition. Various steps for image registration, reduction of shot noise, photogrammetry procedure to map images from the four cameras on a grid for the model, and finally a calibration procedure to convert the measured fluctuations in light intensity to fluctuating pressure, are discussed in the paper. The calibration process using a set of unsteady pressure sensors mounted on the model, was found to overcome some of the inherent problems of the fast response paint, such as rapid photo-degradation, non-linearity in pressure response, and significant temperature sensitivity. Comparison of spectra of pressure fluctuations between UPSP and pressure sensors demonstrated the ability of the paint to faithfully follow fluctuations up to 10 kHz, the maximum attempted. It was also found that the camera bit-depth and the illumination level limited the lowest measurable levels of pressure fluctuations to around 140dB. The large data set exposed various critical transonic flow physics not seen before, such as a coupling of the shock motion on the Payload Fairing (PF) with the separated flow region on the upper stage of the launch vehicle, and upstream convection of pressure fluctuation on PF at certain Mach numbers. The data also confirmed the expectation of a general lowering of the coefficient of pressure fluctuation with Mach number. The availability of the data set on a dense, regularly-spaced, surface grid allowed for the calculation of wavenumber-frequency (k-) spectra via straightforward applications of Fourier transform. The k- spectra were compared for the separated flow regions on the Second Stage, and the shock-boundary layer interactions on PF. The former showed self-similarity with Mach number while the latter was distinctly different, and confirmed the upstream propagation of pressure fluctuations. The k- spectra were dominated by the convected fluctuations; the acoustic domain was not discernable. These data, valuable for the vibro-acoustics analysis of aerospace vehicles, are believed to be the first obtained for the transonic flight regime, and pave the path for application on production models of aerospace vehicles.

buffet↗

Novel Electrolytes for Use in Li-Air Batteries for NASA Electric Aircraft

Li-Air batteries are a unique fit for electric aircraft due to their high theoretical energy densities and their potential to leverage on-board oxygen systems. The electrolyte and cathode are the limiting factors for advancing this technology. We are investigating novel "electrolyte and cathode engineering" concepts to enable Li-Air batteries with high practical energy densities, rechargeability and safety. New stable electrolytes and cathodes are being designed and fabricated for Li-Air batteries. An array of various electrolytes were screened and analyzed using NMR and DEMS analysis techniques to understand the fundamental decomposition mechanisms at the cathode surface and within the porous polymer separator. (NMR) spectroscopy has yielded mechanistic insight into decomposition pathway, which is vital to the development of future stable electrolyte candidates. Thus far, five new electrolytes have been screened with 2 showing promising results.

Li-Air↗

Porous Covalent Organic Polymers for Efficient Fluorocarbon‐Based Adsorption Cooling

Abstract Adsorption‐based cooling is an energy‐efficient renewable‐energy technology that can be driven using low‐grade industrial waste heat and/or solar heat. Here, we report the first exploration of fluorocarbon adsorption using porous covalent organic polymers (COPs) for this cooling application. High fluorocarbon R134a equilibrium capacities and unique overall linear‐shaped isotherms are revealed for the materials, namely COP‐2 and COP‐3. The key role of mesoporous defects on this unusual adsorption behavior was demonstrated by molecular simulations based on atomistic defect‐containing models built for both porous COPs. Analysis of simulated R134a adsorption isotherms for various defect‐containing atomistic models of the COPs shows a direct correlation between higher fluorocarbon adsorption capacities and increasing pore volumes induced by defects. Combined with their high porosities, excellent reversibility, fast kinetics, and large operating window, these defect‐containing porous COPs are promising for adsorption‐based cooling applications.

Zheng, Jian↗

Porous Covalent Organic Polymers for efficient Fluorocarbon-based Adsorption Cooling

Adsorption-based cooling is an energy-efficient renewable-energy technology that can be driven using low-grade industrial waste heat and/or solar heat. Here, we report the first exploration of fluorocarbon adsorption using porous covalent organic polymers (COPs) for this cooling application. High fluorocarbon R134a equilibrium capacities and unique overall linear-shaped isotherms are revealed for the materials, namely COP-2 and COP-3. The key role of mesoporous defects on this unusual adsorption behavior was demonstrated by molecular simulations based on atomistic defect-containing models built for both porous COPs. Analysis of simulated R134a adsorption isotherms for various defect-containing atomistic models of the COPs shows a direct correlation between higher fluorocarbon adsorption capacities and increasing pore volumes induced by defects. Combined with their high porosities, excellent reversibility, fast kinetics, and large operating window, these defect-containing porous COPs are promising for adsorption-based cooling applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Polyurethane Microparticles for Stimuli Response and Reduced Oxidative Degradation in Highly Porous Shape Memory Polymers

Shape memory polymers (SMPs) have been found to be promising biomaterials for a variety of medical applications; however, the clinical translation of such technology is dependent on tailorable properties such as gravimetric changes in degradation environments. For SMPs synthesized from amino-alcohols, oxidation resulting in rapid mass loss may be problematic in terms of loss of material functionality as well as toxicity and cytocompatibility concerns. Control of gravimetric changes was achieved through the incorporation of small molecule antioxidants, either directly into the polymer matrix or included in microparticles to form a SMP composite material. Direct incorporation of small molecule antioxidants, such as phenolic alcohols, was found to alter shape memory attributes and increase elastic modulus at the expense of the strain to failure. Such changes could not ensure retention of the antioxidants and therefore did not increase oxidative stability. However, the inclusion of antioxidants in microparticles was found to produce materials with similar thermomechanical and shape memory properties while increasing oxidative resistance compared to controls. The microparticle composite SMPs also act as a platform for environmental sensing, such as pH-dependent fluorescence shifts and payload release, as demonstrated by fluorescent dyes and the release of antioxidants. The use of polyurethane-urea microparticles in porous SMPs is demonstrated to increase biostability of the materials, by approximately 25%, and ultimately extend their lifespan for use in aneurysm occlusion as determined through calculated in vivo degradation rates corresponding to a porcine aneurysm environment.

Weems, A. C.↗

Nanoporous Catalysts for Biomass Conversion

Transforming plant biomass to biofuel and chemicals has become a global effort as results of increasing fuel demand but diminishing fossil-based energy preservation and rising concerns of climate and environmental impact. Various conversion routes involving thermochemical and biological conversions have been established and well-studied. Heterogeneous catalysis is playing a critical role in the biomass conversion and, with some unique catalytic properties, nanoporous catalysts have been extensively utilized in catalytic process of biomass conversion and exhibited exciting catalytic performance. This chapter will be devoted to nanoporous catalysts used in biomass conversion. It will start with a brief introduction of current biomass conversion technologies and then a detailed review of the application of various nanoporous materials in a large diversity of catalytic reactions in biomass conversion. The nanoporous materials include zeolites and zeotypes, metal-organic frameworks (MOFs), nanoporous carbons and carbon nitrides, nanoporous oxides, hydroxides and complex oxide forms, porous organic polymers (POPs), and porous metals.

Shi, Hui↗

Template-free fabrication of fractal porous Y 2 O 3 monolithic foam and its functional modification by Ni-doping

Fractal structures which display nearly the same character at every scale exist widely in nature, however, it is still a great challenge to fabricate a fractal nanostructure. Herein, a Y 2 O 3 monolith with unique hierarchically fractal porous structure was fabricated via calcination of a fractal porous coordination polymer precursor. The monolith exhibits porous feature with the pore-size ranging from micrometers to nanometers. Interestingly, each level of the pore-wall is composed of secondary porous structures, whose pore-wall is composed of sub-level self-similar porous feature. Moreover, by Ni-doping in the coordination polymer precursor, fractal porous Ni@Y 2 O 3 was prepared, and exhibited enhanced activity in ethanol steam reforming compared with that of a common supported NiO catalyst.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modulating Interactions between Molten Polystyrene and Porous Solids Using Atomic Layer Deposition

Understanding and modulating the interactions between molten polymers and porous solids is important for numerous processes and phenomena including catalytic conversion of polymers and fabrication of nanocomposites and nanostructured materials. Although changing the surface composition of pores would enable modulation of interactions between polymer and nanoporous solids, it is challenging to achieve such a control without inducing significant changes to the size and structure of nanopores. In this work, we demonstrate that the interactions between molten polystyrene (PS) and disordered packings of SiO 2 nanoparticles (NPs) can be modulated by changing the surface composition of the NPs using atomic layer deposition (ALD). A disordered packing of silica NPs is modified with varying surface coverages of TiO 2 , WO 3 and CaCO 3 , with coverages estimated by the mass gain and the refractive index change of NP packings. Based on the time required to fully infiltrate these ALD-modified NP packings via capillarity, the contact angles for PS on different surfaces prepared via ALD are determined. The contact angle gradually changes from that of pure SiO 2 to that of the fully covered surfaces. The contact angles for PS on SiO 2 , TiO 2 , WO 3 and CaCO 3 are found to be 20°, 62°, 70° and 10°, respectively. Interestingly, the contact angles and interfacial energies between PS and the ALD-modified surfaces do not correlate strongly with the water contact angle of these surfaces; thus, caution must be exercised in predicting how a polymer would wet or interact with porous solids solely based on their hydrophilicity. Furthermore, the method presented in this work can be extended to study the interactions between a wide range of polymers and surfaces in porous media, which will have important implications for designing new catalytic materials for polymer upcycling reactions as well as novel NP-polymer composite films and membranes with enhanced mechanical and transport properties.

36 MATERIALS SCIENCE↗

Generalizable Porous Aromatic Framework‐Included Polymer Membranes for Diffusion‐Enhanced Gas Separations

Industrial separation processes account for 10-15% of global energy consumption. Membrane-based processes are less energy-intensive than traditional gas separation technologies; however, enhanced material separation performance and stability for numerous gas mixtures are needed for widespread industrial adoption. This work presents a generalizable strategy for preparing mixed-matrix gas separation membranes exceeding the performance upper bounds of existing polymer membranes for a wide variety of industrial gases. By incorporating robust porous aromatic framework (PAF) particles into various dense commercial polymer matrices, gas diffusivity and solubility can be enhanced. For diverse gas mixtures (e.g., CO2/N2, O2/N2, He/CH4, H2/N2, and C2H4/C2H6), the resulting composite membranes exhibit enhanced gas permeabilities-by as much as 520%-and largely unchanged selectivities even after 6 years of aging under simulated flue gas conditions. These improvements arise from the ultrahigh porosity, excellent chemical compatibility, and unique physicochemical properties of the embedded PAF particles. Functionalizing the PAFs with polyamines also enables composite membranes that achieve among the highest reported performances against plasticization, a common obstacle in commercializing gas separation membranes. Significantly, the PAF-1 particles are readily dispersible in various common membrane casting solvents, suggesting their broader utility as a filler for designing high-performance membranes for many industrial gas separations.

Uliana, Adam A↗

Degradation Effects at the Porous Transport Layer/Catalyst Layer Interface in Polymer Electrolyte Membrane Water Electrolyzer

The porous transport layer (PTL)/catalyst layer (CL) interface plays a crucial role in the achievement of high performance and efficiency in polymer electrolyte membrane water electrolyzers (PEMWEs). This study investigated the effects of the PTL/CL interface on the degradation of membrane electrode assemblies (MEAs) during a 4000 h test, comparing the MEAs assembled with uncoated and Ir-coated Ti PTLs. Our results show that compared to an uncoated PTL/CL interface, an optimized interface formed when using a platinum group metal (PGM) coating, i.e., an iridium layer at the PTL/CL interface, and reduced the degradation of the MEA. The agglomeration and formation of voids and cracks could be found for both MEAs after the long-term test, but the incorporation of an Ir coating on the PTL did not affect the morphology change or oxidation of IrO x in the catalyst layer. In addition, our studies suggest that the ionomer loss and restructuring of the anodic MEA can also be reduced by Ir coating of the PTL/CL interface. Optimization of the PTL/CL interface improves the performance and durability of a PEMWE.

30 DIRECT ENERGY CONVERSION↗