Search NASA⌕ Search

SEARCH · Search NASA

Results for “position measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Chemical identification of new particle formation and growth precursors through positive matrix factorization of ambient ion measurements

Abstract. In the lower troposphere, rapid collisions between ions and trace gases result in the transfer of positive charge to the highest proton affinity species and negative charge to the lowest proton affinity species. Measurements of the chemical composition of ambient ions thus provide direct insight into the most acidic and basic trace gases and their ion–molecule clusters – compounds thought to be important for new particle formation and growth. We deployed an atmospheric pressure interface time-of-flight mass spectrometer (APi-ToF) to measure ambient ion chemical composition during the 2016 Holistic Interactions of Shallow Clouds, Aerosols, and Land Ecosystems (HI-SCALE) campaign at the United States Department of Energy Atmospheric Radiation Measurement facility in the Southern Great Plains (SGP), an agricultural region. Cations and anions were measured for alternating periods of ∼ 24 h over 1 month. We use binned positive matrix factorization (binPMF) and generalized Kendrick analysis (GKA) to obtain information about the chemical formulas and temporal variation in ionic composition without the need for averaging over a long timescale or a priori high-resolution peak fitting. Negative ions consist of strong acids including sulfuric and nitric acid, organosulfates, and clusters of NO3- with highly oxygenated organic molecules (HOMs) derived from monoterpene (MT) and sesquiterpene (SQT) oxidation. Organonitrates derived from SQTs account for most of the HOM signal. Combined with the diel profiles and back trajectory analysis, these results suggest that NO3 radical chemistry is active at this site. SQT oxidation products likely contribute to particle growth at the SGP site. The positive ions consist of bases including alkyl pyridines and amines and a series of high-mass species. Nearly all the positive ions contained only one nitrogen atom and in general support ammonia and amines as being the dominant bases that could participate in new particle formation. Overall, this work demonstrates how APi-ToF measurements combined with binPMF analysis can provide insight into the temporal evolution of compounds important for new particle formation and growth.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Beam dynamics corrections to the Run-1 measurement of the muon anomaly $a_{\mu}$ at Fermilab

The Fermi National Accelerator Laboratory (FNAL) Muon $g\!-\!2$ Experiment has measured the positive muon magnetic anomaly $a_{\mu} \equiv (g_{\mu}-2)/2$ with a precision of 0.46 parts per million, with data collected during its first physics run in 2018. The experimental result combined with the measurement from the former experiment at Brookhaven National Laboratory increases the tension with the Standard Model expectation to $4.2\sigma$, thus strengthening evidence for new physics.The magnetic anomaly is determined from the precision measurements of the muon spin precession frequency, relative to the muon momentum, and the average magnetic field seen by the beam. In an ideal case with muons orbiting in a horizontal plane with a uniform vertical magnetic field, the anomalous precession frequency $\omega_a$ is given by the difference between the spin ($s$) and cyclotron ($c$) frequencies, $\omega_a = \omega_s - \omega_c$. The observable $\omega_a$ is proportional to $a_{\mu}$.This proceeding presents the beam dynamics systematic corrections that are required to adjust the measured muon precession frequency $\omega^{m}_{a}$ to its true physical value $\omega_{a}$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Thermoluminescence Spectroscopy as a Research Tool for Semiconductor and Photonic Materials: A Review and Perspective

Thermoluminescence (TL) or thermally stimulated luminescence (TSL) spectroscopy is based on liberating charge carriers from traps in the bandgap by providing enough thermal energy to overcome the potential barrier of the traps. It provides a powerful tool to measure the positions of the localized states/traps in the bandgap. Despite that, its applications in semiconductors are very limited. Herein, the basics of TL spectroscopy and the recent advances in the technique with focus on cryogenic thermally stimulated photoemission spectroscopy (C‐TSPS) which extends TL measurements to cryogenic regime and allows the detection of very low concentrations of shallow and deep localized states is discussed. One goal herein is to introduce the reader to the use of TL and C‐TSPS in the characterization of semiconductors, explaining how it can be applied and demonstrating its advantages as a powerful tool for measuring shallow donor/acceptor ionization energies in semiconductors and as a method for characterizing compensating defects. The article also discusses interesting potential applications of C‐TSPS in new research areas such as corrosion and formation of oxide layers on metal surfaces.

36 MATERIALS SCIENCE↗

Application of radiochromic gel dosimetry to commissioning of a megavoltage research linear accelerator for small–field animal irradiation studies

To develop and implement an efficient and accurate commissioning procedure for small-field static beam animal irradiation studies on an MV research linear accelerator (Linatron-M9) using radiochromic gel dosimetry. The research linear accelerator (Linatron-M9) is a 9 MV linac with a static fixed collimator opening of 5.08 cm diameter. Lead collimators were manually placed to create smaller fields of 2 × 2 cm 2 , 1 × 1 cm 2 , and 0.5 × 0.5 cm 2 . Relative dosimetry measurements were performed, including profiles, percent depth dose (PDD) curves, beam divergence, and relative output factors using various dosimetry tools, including a small volume ionization chamber (A14), GAFCHROMIC™ EBT3 film, and Clearview gel dosimeters. The gel dosimeter was used to provide a 3D volumetric reference of the irradiated fields. The Linatron profiles and relative output factors were extracted at a reference depth of 2 cm with the output factor measured relative to the 2 × 2 cm 2 reference field. Absolute dosimetry was performed using A14 ionization chamber measurements, which were verified using a national standards laboratory remote dosimetry service. Absolute dosimetry measurements were confirmed within 1.4% (k = 2, 95% confidence = 5%). The relative output factor of the small fields measured with films and gels agreed with a maximum relative percent error difference between the two methods of 1.1 % for the 1 × 1 cm 2 field and 4.3 % for the 0.5 × 0.5 cm 2 field. These relative errors were primarily due to the variability in the collimator positioning. The measured beam profiles demonstrated excellent agreement for beam size (measured as FWHM), within approximately 0.8 mm (or less). Film measurements were more accurate in the penumbra region due to the film’s finer resolution compared with the gel dosimeter. Following the van Dyk criteria, the PDD values of the film and gel measurements agree within 11% in the buildup region starting from 0.5 cm depth and within 2.6 % beyond maximum dose and into the fall-off region for depths up to 5 cm. The 2D beam profile isodose lines agree within 0.5 mm in all regions for the 0.5 × 0.5 cm 2 and the 1 × 1 cm 2 fields and within 1 mm for the larger field of 2 × 2 cm 2 . The 2D PDD curves agree within approximately 2% of the maximum in the typical therapy region (1–4 cm) for the 1 × 1 cm 2 and 2 × 2 cm 2 and within 5% for the 0.5 × 0.5 cm 2 field. This work provides a commissioning process to measure the beam characteristics of a fixed beam MV accelerator with detailed dosimetric evaluation for its implementation in megavoltage small animal irradiation studies. Radiochromic gel dosimeters are efficient small-field relative dosimetry tools providing 3D dose measurements allowing for full representation of dose, dosimeter misalignment corrections and high reproducibility with low inter-dosimeter variability. Altogether, radiochromic gels are valuable for fast, full relative dosimetry commissioning in comparison to films for application in high-energy small-field animal irradiation studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dark Energy Survey Year 3 results: A 2.7% measurement of baryon acoustic oscillation distance scale at redshift 0.835

We present angular diameter measurements obtained by measuring the position of baryon acoustic oscillations (BAO) in an optimized sample of galaxies from the first three years of Dark Energy Survey data (DES Y3). The sample consists of 7 million galaxies distributed over a footprint of 4100 deg 2 with 0.6 < z photo < 1.1 and a typical redshift uncertainty of 0.03 ( 1 + z ) . The sample selection is the same as in the BAO measurement with the first year of DES data, but the analysis presented here uses three times the area, extends to higher redshift, and makes a number of improvements, including a fully analytical BAO template, the use of covariances from both theory and simulations, and an extensive preunblinding protocol. We used two different statistics; angular correlation function and power spectrum, and validate our pipeline with an ensemble of over 1500 realistic simulations. Both statistics yield compatible results. We combine the likelihoods derived from angular correlations and spherical harmonics to constrain the ratio of comoving angular diameter distance D M at the effective redshift of our sample to the sound horizon scale at the drag epoch. We obtain D M ( z eff = 0.835 ) / r d = 18.92 ± 0.51 , which is consistent with, but smaller than, the Planck prediction assuming flat Λ CDM , at the level of 2.3 σ . The analysis was performed blind and is robust to changes in a number of analysis choices. It represents the most precise BAO distance measurement from imaging data to date, and is competitive with the latest transverse ones from spectroscopic samples at z > 0.75 . When combined with DES 3 x 2 pt + SNIa , they lead to improvements in H 0 and Ω m constraints by ∼ 20 % .

79 ASTRONOMY AND ASTROPHYSICS↗

SILICON CARBIDE THERMOMETRY USING RAMAN SPECTROSCOPY ON IRRADIATED TRISO PARTICLES

Silicon carbide (SiC) passive thermometry has emerged as a promising post-irradiation examination (PIE) technique for estimating irradiation temperature near the end of irradiation. While dilatometry techniques have been traditionally used to analyze prismatic samples after irradiation, Raman spectroscopy has recently been shown to provide comparable results by analyzing Raman-active phonon modes. In this work, Raman spectroscopy has been applied to the SiC layer of cross-sectioned irradiation tristructural isotropic (TRISO) particles from the AGR-5/6/7 experiment to evaluate the feasibility of particle-scale passive thermometry. Two-dimensional Raman mapping was used to measure the position of the SiC longitudinal optical (LO) phonon, which was then converted to an apparent irradiation temperature using a previously established empirical correlation. Particles from AGR-5/6/7 Compacts 2-2-1 and 5-1-3 were selected as their calculated time-averaged, volume-averaged (TAVA) temperatures (828°C and 706°C, respectively) fall within the range of the sensitivity of the experimental approach. The use of SiC thermometry was anticipated to confirm or highlight potential deviations from calculated end-of-life TAVA temperature across compacts. Four particles from Compact 2-2-1 and two particles from Compact 5-1-3 were selected based on 110mAg inventory (either some measurable activity or below the minimum detection limit) which is commonly used as an indicator of in-pile temperature variation of particles within the same compact. Across every particle selected it was determined that the average LO peak position was located around 968 cm-1 to 969 cm-1. Using the previously determined empirical correlation, this corresponds to an irradiation temperature around 950°C to 966°C, which does not align with the reported TAVA temperature values. This discrepancy in apparent irradiation temperatures likely reflects a combination of uncertainties in the calculated particle temperatures and differences in irradiation history between the present specimens and those used to establish the empirical Raman calibration such as neutron flux (damage rate) and SiC microstructure (as fabricated and irradiated).

Vawdrey, Josh [ORNL]↗

ECAR-1943 AGC-1 INDIVIDUAL SPECIMEN FLUENCE, TEMPERATURE, AND LOAD CALCULATION AND TABULATION

This ECAR calculates the fluence and temperature of the AGC-1 specimens as they change elevation through the course of the experiment. The specimen elevation varies as the specimen stack shrinks due to irradiation and load induced creep. The compressed specimen stacks (S-1 thru S-6) have a graphite pushrod that applies a gas cylinder load. The top of the pushrod position is measured and recorded in the NGNP Data Management and Analysis System (NDMAS). The bottom of each of these compressed stacks is supported by the lower specimen holder which also shrinks as a result of irradiation and load. The specimen holder post-irradiation length was recorded during post-irradiation examination (PIE). Assuming the specimen holder shrinkage is linear with respect to the fluence received, the position of the top of the specimen holder can be calculated with respect to reactor integrated power. Assuming that individual specimen shrinkage is proportional to the fluence received, and that the shrinkage behavior is similar in all the specimens, the individual specimen position can be calculated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Inferring dark matter substructure with astrometric lensing beyond the power spectrum

Abstract Astrometry—the precise measurement of positions and motions of celestial objects—has emerged as a promising avenue for characterizing the dark matter population in our Galaxy. By leveraging recent advances in simulation-based inference and neural network architectures, we introduce a novel method to search for global dark matter-induced gravitational lensing signatures in astrometric datasets. Our method based on neural likelihood-ratio estimation shows significantly enhanced sensitivity to a cold dark matter population and more favorable scaling with measurement noise compared to existing approaches based on two-point correlation statistics. We demonstrate the real-world viability of our method by showing it to be robust to non-trivial modeled as well as unmodeled noise features expected in astrometric measurements. This establishes machine learning as a powerful tool for characterizing dark matter using astrometric data.

convolutional neural networks (1938)↗

Evaluation of Uncertainties of Pressure Gain Measurements in Rotating Detonation Combustor

Experimentally measuring the pressure gain of a rotating detonation combustor through the method of equivalent available pressure is prone to many experimental uncertainties. A detailed analysis of sources of random and systematic uncertainties in the thrust and pressure gain is performed using data from a hydrogen/air-operated rotating detonation combustor. The combustor had an axial air inlet and a 50% exit constriction. The measured (negative) pressure gain values agree with the results in the literature for similar inlet-to-exit area ratios. The base drag correction on the centerbody was found to be the greatest source of uncertainty for the thrust. While thrust is the predominant source of random uncertainty in the pressure gain calculation, significant systematic errors can be committed due to the assumed exit Mach number. The impact of this assumption becomes more detrimental the closer to positive the measured pressure gain is. By experimentally evaluating the exit Mach number, the random and systematic uncertainty in pressure gain both decreased, indicating that this should be an essential step. A definitive demonstration of gain is challenging, given the assessed uncertainties, and recommendations are provided to increase the precision of the equivalent available pressure methodology.

Engineering↗

The phase-space structure of dark matter haloes

ABSTRACT The phase space structure of dark matter haloes can be used to measure the mass of the halo, infer mass accretion rates, and probe the effects of modified gravity. Previous studies showed that the splashback radius can be measured in position space using a sharp drop in the density profile. Using N-body simulations, we model the distribution of the kinematically distinct infalling and orbiting populations of subhaloes and haloes. We show that the two are mixed spatially all the way to redge, which extends past the splashback radius defined by the drop in the spherically averaged density profile. This edge radius can be interpreted as a radius that contains a fixed fraction of the apocentres of dark matter particles. Our results highlight the possibility of measuring the outer boundary of a dark matter halo using its phase space structure and provide a firm theoretical foundation to the satellite galaxy model adopted in the companion paper, where we analysed the phase space distribution of Sloan Digital Sky Survey redMaPPer clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision luminosity measurement in proton–proton collisions at $\sqrt{s}$ = 13 TeV in 2015 and 2016 at CMS

The measurement of the luminosity recorded by the CMS detector installed at LHC interaction point 5, using proton–proton collisions at √s = 13 TeV in 2015 and 2016, is reported. The absolute luminosity scale is measured for individual bunch crossings using beam-separation scans (the van der Meer method), with a relative precision of 1.3 and 1.0% in 2015 and 2016, respectively. The dominant sources of uncertainty are related to residual differences between the measured beam positions and the ones provided by the operational settings of the LHC magnets, the factorizability of the proton bunch spatial density functions in the coordinates transverse to the beam direction, and the modeling of the effect of electromagnetic interactions among protons in the colliding bunches. When applying the van der Meer calibration to the entire run periods, the integrated luminosities when CMS was fully operational are 2.27 and 36.3 fb -1 in 2015 and 2016, with a relative precision of 1.6 and 1.2%, respectively. These are among the most precise luminosity measurements at bunched-beam hadron colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Conformal geometry from entanglement

In a physical system with conformal symmetry, observables depend on cross-ratios, measures of distance invariant under global conformal transformations (conformal geometry for short). We identify a quantum information-theoretic mechanism by which the conformal geometry emerges at the gapless edge of a 2+1D quantum many-body system with a bulk energy gap. We introduce a novel pair of information-theoretic quantities (\mathfrak{c}_{\textrm{tot}}, \eta) ( 𝔠 tot , η ) that can be defined locally on the edge from the wavefunction of the many-body system, without prior knowledge of any distance measure. We posit that, for a topological groundstate, the quantity \mathfrak{c}_{\textrm{tot}} 𝔠 tot is stationary under arbitrary variations of the quantum state, and study the logical consequences. We show that stationarity, modulo an entanglement-based assumption about the bulk, implies (i) \mathfrak{c}_{\textrm{tot}} 𝔠 tot is a non-negative constant that can be interpreted as the total central charge of the edge theory. (ii) \eta η is a cross-ratio, obeying the full set of mathematical consistency rules, which further indicates the existence of a distance measure of the edge with global conformal invariance. Thus, the conformal geometry emerges from a simple assumption on groundstate entanglement. We show that stationarity of \mathfrak{c}_{\textrm{tot}} 𝔠 tot is equivalent to a vector fixed-point equation involving \eta η , making our assumption locally checkable. We also derive similar results for 1+1D systems under a suitable set of assumptions.

Kim, Isaac H.↗

Observation of Long-Range Wakefield Effects Generated in an Off-Resonance Tesla-Type Cavity

The interest in controlling emittance dilution effects due to off-axis beam transport in accelerator cavities and the resulting dipolar modes is especially important for the facilities with lower emittance beams. The Fermilab Accelerator Science and Technology (FAST) facility has a unique configuration of two single cavities after the photocathode rf gun followed by a cryomodule. The second capture cavity (CC2) was run 15 kHz off resonance and without rf power while a 25-MeV beam was injected into it. The beam centroid effects were tracked by 10 rf button BPMs with bunch-by-bunch position readout capability downstream in a 12-m drift. Possible LRW effects seemed to dominate our previously observed near-resonant HOM effects at mode 14 in this cavity. This mode also shifted in frequency compared to that of the tuned case based on direct measurements. Submacropulse vertical position slewing of 1400 microns at 11 m downstream was observed with a 125 pC/bunch, 50 bunches per macropulse, and 25-MeV beam. The y-position slew amplitudes as a function of z were also measured. Horizontal positions also showed a slew effect. Both are emittance-dilution effects which one wants to mitigate.

Lumpkin, Alex H.↗

Two (or more) for one: Identifying classes of household energy- and water-saving measures to understand the potential for positive spillover

A key component of behavior-based energy conservation programs is the identification of target behaviors. A common approach is to target behaviors with the greatest energy-saving potential. The concept of behavioral spillover introduces further considerations, namely that adoption of one energy-saving behavior may increase (or decrease) the likelihood of other energy-saving behaviors. This research aimed to identify and describe household energy- and water-saving measure classes within which positive spillover is likely to occur (e.g., adoption of energy-efficient appliances may correlate with adoption of water-efficient appliances), and explore demographic and psychographic predictors of each. Nearly 1,000 households in a California city were surveyed and asked to report whether they had adopted 75 different energy- and/or water-saving measures. Principal Component Analysis and Network Analysis based on correlations between adoption of these diverse measures revealed and characterized eight water-energy-saving measure classes: Water Conservation, Energy Conservation, Maintenance and Management, Efficient Appliance, Advanced Efficiency, Efficient Irrigation, Green Gardening, and Green Landscaping. Understanding these measure classes can help guide behavior-based energy program developers in selecting target behaviors and designing interventions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optical diagnostic design for measuring the radiation front with a mid-leg pumped divertor on DIII-D

The design of an optical diagnostic system to localize the radiation front in a mid-leg pumped divertor configuration on DIII-D is presented. Divertor detachment is a key mechanism for handling power exhaust in tokamaks, and mid-leg pumping offers a promising approach to radiatively dissipate power while maintaining acceptable core performance. To predict the location of the radiation front and design a spectroscopic diagnostic to measure its position, a database of SOLPS-ITER simulations across a range of input powers and gas puffing rates representative of DIII-D operation was employed. These simulations provide self-consistent plasma backgrounds for a Cherab-Raysect synthetic diagnostic framework, which incorporates detailed tokamak geometry and physically accurate ray-tracing. Synthetic simulations of optical sightlines and viewing cone geometry were used to calculate line-integrated emission from the plasma, particularly of the C III 465 nm line, to serve as a proxy for the T e ≈ 7 − 10 eV temperature region associated with the onset and evolution of divertor detachment. Neutral deuterium emission is also evaluated for comparison. The synthetic diagnostic is used to assess the performance of existing DIII-D optical systems, including filterscopes and the Multichord Divertor Spectrometer, and to optimize line-of-sight placement within mechanical and installation constraints. The results provide quantitative guidance for diagnostic implementation on DIII-D and demonstrate the advantage of integrated synthetic diagnostics for divertor design studies and future advanced divertor concepts.

Cherab↗

Electropolishing parameters study for surface smoothening of low-$\beta$650 MHz five-cell niobium superconducting radio frequency cavity

Electropolishing (EP) is applied to niobium (Nb) superconducting radio frequency (SRF) cavities, which are used in particle accelerators for their surface treatment. The EP process for 1.3 GHz cavities has been extensively studied earlier. In this work, a parametric study on EP of low-β (0.61) 650 MHz Nb SRF cavities (LB650), which will be used in pre-production cryomodule for proton improvement plan-II (PIP-II) linear accelerator, was conducted to determine adequate EP conditions for attaining a smooth surface of the cavities. EP performed with the standard parameters and an initial cathode (cathode-I) having a cathode surface area of ~5% of the cavity surface area yielded a rough equator surface of the cavity. The grain step height on the equator weld position was measured to be ~ 32 μm. The rough surface was attributed to preferential grain etching confirmed by a polarization curve showing a linear relationship between the EP current and voltage and the absence of the current plateau region. The cathode was modified to make its surface area twice that of cathode-I. The modified cathode (cathode-M) provided a current plateau region in the corresponding I-V curves measured at different cavity temperatures. The onset voltage for the plateau was found to be higher at higher cavity temperatures. Here this study revealed that even with cathode-M, the standard 18 V was low for EP of such large-sized cavities when the cavity temperature was 18 °C. EP performed at a higher voltage of 22–24.5 V with cathode-M yielded a smooth surface with a grain step height of only 0.6 μm. The applied EP conditions also improved removal uniformity along the cavity length. In contrast to the cavity treated with cathode-I, the cavities treated with cathode-M achieved a significantly higher accelerating gradient (E acc ) in vertical tests conducted in a cryostat at 2 K. The modified EP was found efficient to produce the cavities that achieved E acc of 22.4 MV/m, required by PIP II project in the baseline RF tests, to qualify for further surface processing used to enhance their quality factors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Versatile tape-drive target for high-repetition-rate laser-driven proton acceleration

We present the development and characterization of a high-stability, multi-material, multi-thickness tape-drive target for laser-driven acceleration at repetition rates of up to 100 Hz. The tape surface position was measured to be stable on the sub-micrometre scale, compatible with the high-numerical aperture focusing geometries required to achieve relativistic intensity interactions with the pulse energy available in current multi-Hz and near-future higher repetition-rate lasers ( > kHz). Long-term drift was characterized at 100 Hz demonstrating suitability for operation over extended periods. The target was continuously operated at up to 5 Hz in a recent experiment for 70,000 shots without intervention by the experimental team, with the exception of tape replacement, producing the largest data-set of relativistically intense laser–solid foil measurements to date. This tape drive provides robust targetry for the generation and study of high-repetition-rate ion beams using next-generation high-power laser systems, also enabling wider applications of laser-driven proton sources.

47 OTHER INSTRUMENTATION↗

Elucidation of Marcus Relationships for Hydride Transfer Reactions Involving Transition Metal Hydrides

The rate of hydride transfer from three Ir hydride complexes of the type Cp*Ir( R bpy)H + (Cp* = C 5 Me 5 ; R bpy = 4,4′-R-2,2′-bipyridine, R = OMe, H, CO 2 Me) to six N-methylacridinium ( R Acr + ) acceptors with electronically different substituents in the 2- or 2,7-positions were measured. Using the thermodynamic hydricity of the donors and the hydride affinity of the acceptors the thermodynamic driving forces for hydride transfer were determined. Brønsted plots, which correlate kinetic and thermodynamic hydricity, demonstrate distinct linear free energy relationships for each complex, with different Brønsted α values. Thus, at the same driving force hydride transfer from Cp*Ir( OMe bpy)H + is faster than for Cp*Ir(bpy)H + or Cp*Ir( CO2Me bpy)H + . Experimental and computational analyses are consistent with a concerted hydride transfer mechanism for all Ir complexes. As the thermodynamic driving force increases an earlier transition state is observed and all transition states also include π-stacking interactions between the donor and acceptor, which likely contribute to the different α values. The experimental data fits well to the Marcus model, enabling the determination of reorganization energies (λ) that range from 58 to 69 kcal mol -1 . These are lower than λ values for hydride transfer reactions involving organic donors and acceptors. This work provides a rare example of the correlation of kinetic and thermodynamic hydricity using only experimental data and shows that hydride transfer reactions involving metal hydrides can follow Marcus theory. Furthermore, the findings offer insight into controlling metal-catalyzed hydride transfer reactions, which is valuable for designing improved systems for a range of transformations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗