Search NASA⌕ Search

SEARCH · Search NASA

Results for “power flow solution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Intrinsically asymmetric astrophysical jets

Previous work on the origin of self-collimated electromagnetic jets is extended to the general case where there is no reflection symmetry of the magnetic field about the equatorial plane of the disk. The axisymmetric field structure inside the disk is obtained by solving for the magnetic flux function, and the toroidal magnetic field, from the generalized thin-disk induction equation, which is derived. The asymptotic (large-z) magnetic field structure outside the disk is obtained by solving the force-free Grad-Shafranov equation semianalytically. Jet solutions are found in which the power flow is carried mainly by the Poynting flux of the electromagnetic field and the angular momentum outflow from the disk is carried by the magnetic field. The ratio of jet luminosities (top/bottom) depends directly on the degree of asymmetry of the field and can easily be much greater than unity. It is argued that the degree of field asymmetry in the disk is determined by the asymmetry of the weak galactic field fed into the disk at large distances over long periods of time.

Wang, J. C. L.↗

Modular DC circuit breaker with integrated energy storage for future DC networks

A T-breaker is an all-in-one solution for dc microgrid fault protection, power flow control, and power quality improvement. A T-breaker features a modular multilevel “T” structure with integrated energy storage devices. The two horizontal arms of the T-breaker realize fault current breaking, load voltage compensation, and power flow control; and the vertical arm of the T-breaker realizes shunt compensation. The configuration provides excellent voltage scalability and relaxes the requirements on the switching signal synchronization during fault transients. The local energy storage in sub-modules eases the fault energy dissipation requirement placed on the traditionally-adopted surge arrestors. The modular multilevel structure also offers immense control flexibility for all types of targeted functions of the provided T-breaker.

Wang, Jin↗

Nonlinear effects for the Taylor column for a hemisphere

When a flow is forced past an obstacle in a rapidly rotating fluid, a Taylor column forms. This is defined by a set of vertical detached shear layers circumscribing the obstacle which provide the smooth transition from an external inviscid potential flow to a stagnant core above the obstacle. For a hemispherical object, the main adjustment takes place in an external E to the 1/4 power layer and an internal E to the 2/7 power layer; here, the nonlinear flow in these layers is investigated. The problem in the E to the 1/4 power layer is identical to a problem occurring in magnetohydrodynamic flow; in addition, some features of the magnetohydrodynamic problem have been resolved. Numerical solutions are obtained for the steady nonlinear external E to the 1/4 power layer flow up to the point where unsteady flow separation from the Taylor column is imminent. The response of the internal E to the 2/7 power layer to the flow in the E to the 1/4 power layer is calculated, and the results suggest that the internal shear layer is unlikely to play any significant role in the separation process

Crisalli, A. J.↗

Fast Iterative Multi-site Hosting Capacity Analysis for Distribution Systems With Search Space Pruning

Interconnection studies for distributed energy resources (DERs) is a time-intensive process, primarily due to the necessity of solving large number of power flow scenarios. Hosting capacity analysis (HCA) is a time-consuming aspect of interconnection studies that is divided into single-site HCA (SHCA) and multi-site HCA (MHCA). From a computational and understandable standpoint, the industry seeks iteration-based solutions for SHCA, although it doesn't maximize the total DER hosting capacity (DERHC) of the grid, as MHCA does. While non-iterative solutions are available for MHCA, they involve a trade-off between the modeling accuracy of the distribution system, solution quality, and ease of understanding. In this work, we present a fast iterative solution for MHCA, reducing computational complexity by eliminating the need to solve power flows for a large amount of search space, thus making iterative solutions feasible. This iterative approach guarantees both a global optimal solution with sufficient time and a fast, close-to-optimal solution through efficient search space pruning. It also easily integrates with existing utility HCA tools. The results are demonstrated on select locations in the IEEE-123 bus system for community-scale interconnection studies. We highlight the benefits of skipping the need to solve millions of power flows, all while maximizing the grid's total DERHC.

Guddanti, Kishan Prudhvi↗

Taylor-Expansion-Based Robust Power Flow in Unbalanced Distribution Systems: A Hybrid Data-Aided Method

Traditional power flow methods often adopt certain assumptions designed for passive balanced distribution systems, thus lacking practicality for unbalanced operation. moreover, their computation accuracy and efficiency are heavily subject to unknown errors and bad data in measurements or prediction data of distributed energy resources (ders). to address these issues, this paper proposes a hybrid data-aided robust power flow algorithm in unbalanced distribution systems, which combines taylor series expansion knowledge with a data-driven regression technique. the proposed method initiates a linearization power flow model to derive an explicitly analytical solution by modified taylor expansion. to mitigate the approximation loss that surges due to the der integration and bad data, we further develop a data-aided robust support vector regression approach to estimate the errors efficiently. comparative analysis in the 13-bus and 123-bus ieee unbalanced feeders shows that the proposed hybrid algorithm achieves superior computational efficiency, with guaranteed accuracy and robustness against outliers.

data-driven↗

Coordinated Inverter Control to Increase Dynamic PV Hosting Capacity: A Real-Time Optimal Power Flow Approach

High penetrations of distributed photovoltaics (PV) could cause adverse grid impacts, such as voltage violations. The recent development in inverter technologies provides the opportunity to develop control systems to realize effective PV governance and thus to improve dynamic PV hosting capacity for distribution grids. In this paper, a novel distributed energy resource management system (DERMS) solution is proposed by adopting the real-time optimal power flow (OPF) approach for coordinated control of the distributed PV inverters. The proposed approach eliminates the dependence on load knowledge via measurement feedback correction, and it can be implemented in real time. One challenge is that the technique is sensitive to the data availability and integrity of voltage measurements. Therefore, a decentralized DERMS approach is developed by leveraging the concepts of state estimation. The framework and the effectiveness of the solution approach are numerically demonstrated on a real distribution feeder in Southern California.

14 SOLAR ENERGY↗

Predicting Water Cycle Characteristics from Percolation Theory and Observational Data

The fate of water and water-soluble toxic wastes in the subsurface is of high importance for many scientific and practical applications. Although solute transport is proportional to water flow rates, theoretical and experimental studies show that heavy-tailed (power-law) solute transport distribution can cause chemical transport retardation, prolonging clean-up time-scales greatly. However, no consensus exists as to the physical basis of such transport laws. In percolation theory, the scaling behavior of such transport rarely relates to specific medium characteristics, but strongly to the dimensionality of the connectivity of the flow paths (for example, two- or three-dimensional, as in fractured-porous media or heterogeneous sediments), as well as to the saturation characteristics (i.e., wetting, drying, and entrapped air). In accordance with the proposed relevance of percolation models of solute transport to environmental clean-up, these predictions also prove relevant to transport-limited chemical weathering and soil formation, where the heavy-tailed distributions slow chemical weathering over time. The predictions of percolation theory have been tested in laboratory and field experiments on reactive solute transport, chemical weathering, and soil formation and found accurate. Recently, this theoretical framework has also been applied to the water partitioning at the Earth’s surface between evapotranspiration, ET, and run-off, Q, known as the water balance. A well-known phenomenological model by Budyko addressed the relationship between the ratio of the actual evapotranspiration (ET) and precipitation, ET/P, versus the aridity index, ET 0 /P, with P being the precipitation and ET 0 being the potential evapotranspiration. Existing work was able to predict the global fractions of P represented by Q and ET through an optimization of plant productivity, in which downward water fluxes affect soil depth, and upward fluxes plant growth. In the present work, based likewise on the concepts of percolation theory, we extend Budyko’s model, and address the partitioning of run-off Q into its surface and subsurface components, as well as the contribution of interception to ET. Using various published data sources on the magnitudes of interception and information regarding the partitioning of Q, we address the variability in ET resulting from these processes. The global success of this prediction demonstrated here provides additional support for the universal applicability of percolation theory for solute transport as well as guidance in predicting the component of subsurface run-off, important for predicting natural flow rates through contaminated aquifers.

54 ENVIRONMENTAL SCIENCES↗

R3IT, Rapid Rural Resilient Interconnection Toolkit, Final Technical Report

Utilities nationwide are beginning to experience multiple solar interconnection requests per day. This request volume will soon overwhelm utility engineers, especially at smaller utilities which serve the majority of the landmass of the United States. In this project, we developed open-source software tool that automates the interconnection approval process and removes 80% of the time required to approve an interconnection and hence allow more solar to be quickly and safely integrated with the grid. This software is accompanied by a guidebook detailing interconnection best practices and utility lessons learned. Competing solar interconnection software is extremely expensive at ten times the cost of typical distribution engineering tools, it’s closed source which makes it hard to integrate into utility workflows, and it doesn’t address the hardest power flow modeling challenges of interconnection screening. Our solution was built built with our utility partners who are already experiencing multiple interconnection requests per day and integrates best practices from our past work with DOE and the cooperative community on solar integration. The resulting free and open-source solution has been disseminated through our media channels and conferences that engage over 1,900 utilities nationwide.

14 SOLAR ENERGY↗

Stability of absorption phenomena in laser-thermal propulsion

The mean flow and stability characteristics of laser absorption phenomena in a choked converging-diverging nozzle are considered. Calculations are presented for a given nozzle geometry and a series of laser intensities. Gas absorptivities corresponding to a hydrogen-cesium mixture are used with different initial temperatures being selected to investigate the effects of changes in the shape of the k-T curve. Both stability and mean flow calculations are limited to the one-dimensional case. The mean flow results show a decrease in mass flow as laser power is increased, along with increasingly steep temperature profiles. Calculations span regions of partial and complete absorption. One region is found where multiple solutions exist. Local stability results indicate the u-c characteristic is the only unstable mode in the unheated case. Laser heat addition makes this mode more unstable and also destabilizes the u-characteristic. Numerical calculations of disturbance propagation show that the instability of the u-c disturbances is counteracted by their reflection to u + c disturbances at the upstream end. The growth of the u-disturbances is localized in regions where the temperature profile is steep and they are damped in other regions. The increasing destabilization that is observed with increased laser power is probably the reason for difficulty in obtaining converged mean flow solutions at high laser intensities.

Merkle, C. L.↗

Generalized Power Flow Model of an Extra High-Power Multi-Terminal HVdc Transmission Grid with Parallel-Connected and Voltage-Stacked Converters

To increase power transfer capacity of high-voltage direct current (HVdc) transmission, a new extra high-power HVdc architecture with multiple standard modular multilevel converters (MMCs) per substation has recently been introduced. This paper proposes a power flow model for a multi-terminal HVdc (MTdc) grid with this innovative substation architecture. The proposed MTdc model can be integrated seamlessly with existing ac-dc power flow algorithms with minimal modifications. The model is applicable to various MTdc grid types and topologies, different numbers of dc buses, dc lines, and MMCs per substation, along with diverse control parameters. In addition, it accurately captures both balanced and unbalanced operations of the MTdc grid. The proposed model is verified using a 5-terminal bipole MTdc grid that spans 4 areas in the Eastern Interconnection system of the USA. The numerical solutions obtained from unified and sequential ac-dc power flow algorithms under different operating conditions closely match the time-domain simulation results in PSCAD, validating the accuracy and versatility of the proposed MTdc power flow model.

Nguyen, Quan H.↗

Magnetohydrodynamic model of the Crab Nebula and its radiation

The interaction of the Crab pulsar with its surrounding nebula is modeled as a steady state, spherically symmetric relativistic wind which is confined by the outer layers of the supernova remnant. The pulsar wind is assumed to contain only positrons and electrons, and is terminated by a strong shock at a distance of 10 arcseconds from the pulsar, at the outer edge of the underluminous region. Down-stream of the shock, the flow decelerates and increases its pressure in order to match the boundary conditions imposed by outer nebula. Consistent flow solutions can be found if the magnetic luminosity of the pulsar wind is about 0.3 percent of its particle luminosity. The immediate postshock plasma is modeled as a power law distribution whose density and pressure moments satisfy the strong shock Rankine-Hugoniot relations. Using the downstream flow solution, the synchrotron continuum is calculated. The parameters of the pulsar wind and assumed power law spectral index are adjusted until the calculated total synchrotron power and the spectral distribution of the nebular continuum from optical to gamma-rays, are in reasonable accord with observations.

Coroniti, F. V.↗

A nonsmooth nonconvex optimization algorithm for two-stage optimization problems

An optimization algorithm for a group of nonsmooth nonconvex problems inspired by two-stage stochastic programming problems is proposed. The main challenges for these problems include (1) the problems lack the popular lower-type properties such as prox-regularity assumed in many nonsmooth nonconvex optimization algorithms, (2) the objective can not be analytically expressed and (3) the evaluation of function values and subgradients are computationally expensive. To address these challenges, this report first examines the properties that exist in many two-stage problems, specifically upper-C 2 objectives. Then, we show that quadratic penalty method for securityconstrained alternating current optimal power flow (SCACOPF) contingency problems can make the contingency solution functions upper-C 2 . Based on these observations, a simplified bundle algorithm that bears similarity to sequential quadratic programming (SQP) method is proposed. It is more efficient in implementation and computation compared to conventional bundle methods. Global convergence analysis of the algorithm is presented under novel and reasonable assumptions. The proposed algorithm therefore fills the gap of theoretical convergence for smoothed SCACOPF problems. The inconsistency that might arise in our treatment of the constraints are addressed through a penalty algorithm whose convergence analysis is also provided. Finally, theoretical capabilities and numerical performance of the algorithm are demonstrated through numerical examples.

97 MATHEMATICS AND COMPUTING↗

Certification and prediction of post-disturbance states in dynamic security assessment

Dynamic security assessment usually involves the simulation of system dynamics under large disturbances. The instant large disturbance occurs, the post-disturbance state of the system could deviate significantly from the pre-disturbance one. It is desirable and necessary to develop an efficient method to certify the existence of state and predict the approximate post-disturbance state because: (1) faster warning can be made in online assessment; and (2) the dynamic simulator can be given better initial values to calculate precise solutions, which prevents convergence failure brought on by poor initial values. We propose a novel approach for efficiently certifying and predicting the post-disturbance states in dynamic security assessment. Based on the fixed-point power flow mapping approach applied to salient pole generator models, the criterion for determining the existence and uniqueness of the post-disturbance solution is derived, and the bounds of post-disturbance solution can be rigorously characterized.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced numerics for multi-dimensional fluid flow calculations

In recent years, there has been a growing interest in the development and use of mathematical models for the simulation of fluid flow, heat transfer and combustion processes in engineering equipment. The equations representing the multi-dimensional transport of mass, momenta and species are numerically solved by finite-difference or finite-element techniques. However despite the multiude of differencing schemes and solution algorithms, and the advancement of computing power, the calculation of multi-dimensional flows, especially three-dimensional flows, remains a mammoth task. The following discussion is concerned with the author's recent work on the construction of accurate discretization schemes for the partial derivatives, and the efficient solution of the set of nonlinear algebraic equations resulting after discretization. The present work has been jointly supported by the Ramjet Engine Division of the Wright Patterson Air Force Base, Ohio, and the NASA Lewis Research Center.

Vanka, S. P.↗

The Effects of Contaminant-Aging on Decontamination Efficacy for Rapid Remediation of Concrete Surfaces - 20412

Understanding the relationship between decontamination efficacy and contaminant aging is imperative for developing effective remediation strategies following a large-scale contamination event. Non-destructive decontamination of concrete following a contamination incident becomes more difficult with increased time between contamination and decontamination because contaminants may chemically bind to concrete and/or penetrate into the concrete subsurface. In this work, we evaluated the decontamination efficacy of two decontamination methods on concrete samples contaminated with soluble Cesium-137 (Cs-137) and silica particles with 0.5 μm and 2 μm diameters. Concrete samples were aged between 1 and 59 days, with half of the coupons receiving 1 mL of artificial rainwater about once every three days. After aging, coupons were either decontaminated or analyzed to determine contaminant penetration depths. Coupons were decontaminated with 0.1 M Potassium Chloride (KCI) solution applied either by flowing solution across the contaminated coupon face or non-destructive power washing. Contaminant depth profiles were created by removing the top surface of the coupon at least 15 times, measuring the activity in each removed layer, normalizing the total activity removed to the measured decontamination efficacy following the last layer removal, and determining the penetration thickness using the coupon dimensions, bulk density, and mass of material removed for each layer. Pressurized washing effectively removed particles, but not soluble cesium, despite the majority of Cs-137 being located within the first millimeter of the subsurface. Soluble cesium removal by flowing 0.1 M KCI solution across the contaminated surface dropped to less than 12% within the first ten days. This drop in Cs-137 removal efficacy occurred within the first five days for coupons experiencing artificial rainfall events. Flowing 0.1 M KCI solution across the contaminated face was ineffective at removing particles, likely because particles had localized in surface depressions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Solar-assisted Voltage Optimization Method for Transmission Solar Network Power System

This paper proposes a new formulation and solution algorithm that uses transmission level solar inverters to address the security-constrained optimal power flow (SCOPF) problem. The goal is to stabilize voltage fluctuations in transmission networks in base case and contingency scenarios, by using bulk solar power plant with a minimal number of post-contingency corrections. To achieve this goal, a two-stage volt/var optimization method is proposed to first correct all voltage violations with the volt-var alternating current optimal power flow (ACOPF) algorithm for a base case. Then a linearized SCOPF volt-var control algorithm is proposed to identify the corrective actions for all potential voltage violations in all contingency scenarios. The proposed method was tested and validated on a modified IEEE 118-bus system with solar photovoltaic (PV) data.

Photovoltaic, Volt/Var Control↗

Early Exploration of a Flexible Framework for Efficient Quantum Linear Solvers in Power Systems

The rapid integration of renewable energy resources presents formidable challenges in managing power grids. While advanced computing and machine learning techniques offer some solutions for accelerating grid modeling and simulation, there remain complex problems that classical computers cannot effectively address. Quantum computing, a promising technology, has the potential to fundamentally transform how we manage power systems, especially in scenarios with a higher proportion of renewable energy sources. One critical aspect is solving linear systems of equations, crucial for power system applications like power flow analysis, for which the Harrow-Hassidim-Lloyd (HHL) algorithm is a well-known quantum solution. However, HHL quantum circuits often exhibit excessive depth, making them impractical for current Noisy-Intermediate-Scale-Quantum (NISQ) devices. In this paper, we introduce a versatile framework, powered by NWQSim, that bridges the gap between power system applications and quantum linear solvers available in Qiskit. This framework empowers researchers to efficiently explore power system applications using quantum linear solvers. Through innovative gate fusion strategies, reduced circuit depth, and GPU acceleration, our simulator significantly enhances resource efficiency. Power flow case studies have demonstrated up to a eight-fold speedup compared to Qiskit Aer, all while maintaining comparable levels of accuracy.

quantum computing, Harrow-Hassidim-Lloyd, high-per↗

Ensemble Learning Based Convex Approximation of Three-Phase Power Flow

Though the convex optimization has been widely used in power systems, it still cannot guarantee to yield a tight (accurate) solution to some problems. To mitigate this issue, this paper proposes an ensemble learning based convex approximation for alternating current (AC) power flow equations that differs from the existing convex relaxations. The proposed approach is based on three-phase quadratic power flow equations in rectangular coordinates. To develop this data-driven convex approximation of power flows, the polynomial regression (PR) is first deployed as a basic learner to fit convex relationships between the independent and dependent variables. Then, ensemble learning algorithms such as gradient boosting (GB) and bagging are introduced to combine learners to boost model performance. Based on the learned convex approximation of power flow, optimal power flow (OPF) is formulated as a convex quadratic programming problem. The simulation results on IEEE standard cases of both balanced and unbalanced systems show that, in the context of solving OPF, the proposed data-driven convex approximation outperforms the conventional semi-definite programming (SDP) relaxation in both accuracy and computational efficiency, especially in the cases that the conventional SDP relaxation fails

Convex approximation↗